Professional Documents
Culture Documents
ATE8 Series
This is only for reference, the actual product does not support all combinations. Caution Model ATE8-4□ ATE8-4□D ATE8-4□E
For selecting the specified model, follow the Autonics website. : Refer to the 'specifications' for checking the power supply and control output.
Function Power ON Delay
INSTRUCTION MANUAL
■ ATE8-4□ ■ ATE8-4□D
ATE8 - 4 ❶ ❷ Return time ≤ 200 ms
□44.8
t Rt t Ambient humidity 35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)
control, medical equipment, ships, vehicles, railways, aircraft, combustion
apparatus, safety equipment, crime/disaster prevention devices, etc.) Power Protection rating IP40 (front part, IEC standard)
Failure to follow this instruction may result in personal injury, economic loss or fire.
■ Panel cut-out Instantaneous N.O.
02. Do not use the unit in the place where flammable/explosive/corrosive gas,
high humidity, direct sunlight, radiant heat, vibration, impact or salinity ≥ 65 Time limit N.C.
may be present.
Time limit N.O.
Failure to follow this instruction may result in explosion or fire.
□45 +00.6
Output indicator
04. Do not connect, repair, or inspect the unit while connected to a power
source. ATE8-4□D
Failure to follow this instruction may result in fire or electric shock.
05. Check ‘Connections’ before wiring. t Rt t
Failure to follow this instruction may result in fire. Power
06. Do not disassemble or modify the unit. Unit Descriptions
Time limit N.C.
Failure to follow this instruction may result in fire or electric shock.
Time limit N.O.
Caution
No. Name
Failure to follow instructions may result in injury or product damage. 3
1 1 Output indicator (red) Power indicator
01. Use the unit within the rated specifications. Power indicator (white) Output indicator
4 2
Failure to follow this instruction may result in fire or product damage. 2 Flashing: time progressing
02. Use a dry cloth to clean the unit, and do not use water or organic solvent. Time range setting switch ATE8-4□E
5 3
Failure to follow this instruction may result in fire or electric shock. • s : sec, m : min, h : hour
t Rt t
03. Keep the product away from metal chip, dust, and wire residue which flow 4 Time range display part
into the unit. 5 Dial for the time setting
Power
Failure to follow this instruction may result in fire or product damage. Instantaneous N.C.
Time Range
Instantaneous N.O.
Cautions during Use
Time limit N.C.
• Follow instructions in ‘Cautions during Use’. ■ ATE8-41□ ■ ATE8-43□
Time limit N.O.
Otherwise, it may cause unexpected accidents. Display part Range Display part Range
• When supplying or turning off the power, use a switch or etc. to avoid chattering. Power indicator
1s 0.1 to 1 3s 0.3 to 3
• Install a power switch or circuit breaker in the easily accessible place for supplying or
disconnecting the power. 10s 1 to 10 30s 3 to 30 Output indicator
• In order to avoid leakage current flowing, connect resistance and condenser like 1m 0.1 to 1 3m 0.3 to 3
below. Otherwise, it may cause malfunction.
10m 1 to 10 30m 3 to 30
1h 0.1 to 1 3h 0.3 to 3
R
Power T Timer ■ ATE8-46□ ■ ATE8-4C□
C
Display part Range Display part Range
6s 0.6 to 6 12s 1.2 to 12
• After turning off the power, change the time range, etc. 60s 6 to 60 12m 1.2 to 12
• Connect output contacts of different pole to be electrokinetic potential.
• Keep away from high voltage lines or power lines to prevent inductive noise. In case 6m 0.6 to 6 24m 2.4 to 24
installing power line and input signal line closely, use line filter or varistor at power line 60m 6 to 60 12h 1.2 to 12
and shielded wire at input signal line.
6h 0.6 to 6 24h 2.4 to 24
Do not use near the equipment which generates strong magnetic force or high
frequency noise.
• This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000 m
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
- Pollution degree 2
www.autonics.com | +82-51-519-3232 | sales@autonics.com
- Installation category II