Operating system installation instructions

Follow these instructions to add the ServeRAID C100 for System x driver during the
installation of RHEL 6/CentOS.
Installation Procedure:
1. Create MEGASR driver diskette or USB Key and attach the device to the server.
2. Boot to RHEL 6 installation media to begin install.
3. At the "Welcome to RHEL 6" screen, highlight "Install or upgrade an existing
system" then press "Tab" to edit the boot options,
4. Add the following boot parameters to the to the end of the existing line using
either of the following two sets paramters:

For ServeRAID C105


Linux dd blacklist=isci blacklist=ahci

Press "Enter" to start the install.

5. When prompted, choose "Yes" to having a driver disk.


6. Select the device (diskette or USB key) for the MEGASR driver location.
7. Install any additional drivers or cancel to continue.
8. On the next screen, either verify the media or skip the media test as prompted.
9. The graphic portion of the installation will begin. Continue the installation
following the screens through to completion.