You are on page 1of 24

STEEL CONSTRUCTION PRODUCTS

2
0
1
9
For the past 117 years, L.B. Foster Company (NASDAQ: FSTR) has delivered the products
necessary to build and maintain our nation’s infrastructure. Today, we remain a quality
manufacturer, fabricator and distributor of products for the transportation, construction,
utility and energy industries.
“This brochure presents innovative products born from advanced engineering, quality
workmanship, and more than a century of experience. The L.B. Foster team of skilled
construction professionals stand ready to provide the technical expertise and material
logistics required for your next project.”

Greg Goad, Vice President- Steel Construction Products

Southport Turning Notch Extension Project


Port Everglades, Fort Lauderdale, Florida
Photo courtesy of Orion Marine Construction, Inc.

Z Profile Steel Sheet Pile 2

Sawtooth Steel Sheet Piling 4

Rental Steel Sheet Piling 4

Flat Web Steel Sheet Pile 5

Accessories 7

OPEN CELL™ Structures 8

Combi-Wall 10

Pipe Pile 12

H-Pile 14

Bridge Decking & Railing Systems 15

Contacts 19
www.lbfoster.com

Z Sheet Pile

The innovative PZC™ series of steel sheet piling is domestically manufactured to be wider, lighter and
stronger than traditional PZ piling.

PZC sheet piling is made wider than PZ sections to maximize job site production in setting and driving.
They are lighter than PZ piling to minimize the required amount of steel needed for project installation.
PZC sections are stronger per pound than PZ sections in both section modulus and moment of inertia.

Gerdau is a Member of the US Green Building Council, and reports information necessary to support
earning credits as specified in the Leadership in Energy and Environmental Design (LEED) green building
rating system.

The LEED rating system is intended for building projects, and may not apply to projects that utilize Z-Pile.

LEED encourages responsible global adoption of sustainable green building and development practices
through the creation and implementation of universally understood and accepted tools and performance
criteria provided below:

The following table presents the data for post-consumer, pre-consumer, total recycled content and other
iron units by plant location for the year 2017.

Post-Consumer Pre-Consumer Total Recycled Other Iron Units and


Plant Location
Scrap Content % Scrap Content % Content % Ferro-alloys Content %
Midlothian, TX 86.0 3.0 99 1
Petersburg, VA 81.5 6.6 99 1

Chevron Global Lubricants, Port Arthur, TX Burns Harbor, Port of Indiana, Portage, IN

PZC™ is a trademark of Gerdau.


Page 2
FLANGE COVER PLATE ®
(SEE CHART)

Z Pile Cover Plated


HEIGHT
Profile WEB
Z Profile
TYPICAL PZC26 HEIGHT
SHEET PILE SECTION

WIDTH WIDTH

Thickness Weight Section Modulus Nominal


Width+ Height+ Moment of Inertia
Web Flange Pile Wall Elastic Plastic Coating Area*
Section
in. in. in. in. lb / lft lb / ft2 in4 in4 / ft in3 / ft in3 / ft ft2 / lft
mm mm mm mm kg/lm kg/m2 cm4 cm4 /m cm3 /m cm3 /m m2 / lm
27.88 12.56 0.375 0.375 50.4 21.7 353.0 152.0 24.2 28.8 5.60
PZC 13
708 319 9.5 9.5 75.1 106.0 14,690 20,760 1,300 1,546 1.71
27.88 12.60 0.420 0.420 55.0 23.7 381.6 164.3 26.0 31.3 5.60
PZC 14
708 320 10.7 10.7 81.8 115.5 15,890 22,440 1,400 1,682 1.71
25.00 15.25 0.375 0.375 50.4 24.30 532.2 255.5 33.5 39.5 5.60
PZC 18
635 387 9.5 9.5 75.1 118.2 22,150 34,890 1,800 2,122 1.71
25.00 15.30 0.420 0.420 55.0 26.4 576.3 276.6 36.1 42.8 5.60
PZC 19
635 388 10.7 10.7 81.8 128.8 23,990 37,780 1,945 2,301 1.71
27.88 17.66 0.485 0.560 69.4 29.9 938.7 404.1 45.7 54.6 6.15
PZC 25
708 449 12.3 14.2 103.3 145.9 39,070 55,190 2,455 2,942 1.87
27.88 17.70 0.525 0.600 73.9 31.8 994.3 428.1 48.4 57.9 6.15
PZC 26
708 450 13.3 15.2 110.0 155.4 41,390 58,460 2,600 3,120 1.87
27.88 17.75 0.570 0.645 79.0 34.0 1,057 455.1 51.3 61.7 6.15
PZC 28
708 451 14.5 16.4 117.6 166.1 44,000 62,150 2,755 3,324 1.87

Available Grades: ASTM A572 Gr. 50 and 60, A588 and A690
+Values stated are nominal
* Both sides of sheet: excludes socket interior and ball interlock

Per Single Section Per Unit of Wall


Weight
Total Nominal
Normal Plate Size Full Half Moment of Section
Area Weight Surface Coating
Width (Minimum) Length Length Inertia Modulus
Section Area Area*
Plates Plates
in. in. in2 lb / ft ft2 / lin ft ft2 / lin ft lb / ft2 lb / ft2 in4 / ft in3 / ft
mm mm cm2 kg / m m2 / m m2 / m kg / m2 kg / m2 cm4 / m cm3 / m

PZC 38-CP 27.88 3.5 x 1.00 28.72 97.7 6.98 5.48 42.1 36.9 691.4 70.2

(PZC26) 708 89 x 25 185.3 145.3 2.13 1.67 205.6 180.2 94,420 3,770

PZC 39-CP 27.88 3.5 x 1.125 29.60 100.6 7.03 6.53 43.3 37.6 728.3 73.0

(PZC26) 708 89 x 29 191.0 149.7 2.14 1.99 211.4 183.6 99,460 3,930

PZC 41-CP 27.88 3.0 x 1.500 30.70 105.7 7.07 6.57 45.3 38.8 782.7 75.6

(PZC26) 708 76 x 38 198.1 157.3 2.15 2.00 221.2 189.4 106,888 4,060

* Excludes socket interior and ball interlock Available Grades: ASTM A572 Gr. 50
• Best economy is obtained when plate length is limited to area of high moment.
• Filet weld should be sized to adequately resist design loads and should be continuous and all around.
• Cover plate length depends upon bending moment curve. Page 3
• Weld requirements should be specified by design engineer.
www.lbfoster.com

Sawtooth Steel Sheet Piling

Per Single Section Per Unit of Wall

Wall Moment Total Nominal Moment


Nominal Web Flange Section Section
Depth Area Weight of Surface Coating Area Weight of
Width Thickness Thickness Modulus Modulus
(Height) Inertia Area Area* Inertia
Section

in. in. in. in. in2 lbs /ft in4 in2 ft2 / ft ft2 / ft in2 / ft lbs/ft2 in4 / ft in3/ ft
mm mm mm mm cm2 kg /m cm4 cm2 m2 / m m2 / m cm2 /m kg/m2 cm4 / m cm3/ m
29.86 6.64 0.375 0.375 14.82 50.4 49.9 14.9 6.10 5.60 5.96 20.0 20.0 6.0
PZC 13
759 169 9.5 9.5 95.6 75.1 2,075 245 1.86 1.71 126.1 99.0 2,735 325

28.37 8.14 0.375 0.375 14.82 50.4 74.7 18.1 6.10 5.60 6.27 21.3 31.6 7.7
PZC 18
721 207 9.5 9.5 95.6 75.1 3,110 300 1.86 1.71 132.7 104.2 4,315 415

32.07 8.43 0.525 0.600 21.72 73.9 115.5 27.4 6.65 6.15 8.13 27.7 43.2 10.2
PZC 26
815 214 13.3 15.2 140.1 110.0 4,810 450 2.03 1.87 172.1 135.0 5,905 550

*Both sides of sheet; excludes socket interior and ball interlock

PZC Sheet Pile Rental


Benefits to renting PZC sheet pile:
»» Made in the USA.
»» Low initial cost.
»» Strategic stocking locations throughout the U.S.
»» Interlocks warranted to be continuous and reasonably free-sliding to grade when threaded.
»» Contractor preferred ball & socket interlocks.
»» Wider, lighter, stronger PZC sheet pile maximizes job site efficiency.
»» Why buy when you can RENT?

Page 4
®

Flat Web Sheet Pile

L.B. Foster distributes domestically produced


Gerdau PS 27.5 and PS 31 steel flat web sheets.
Compared to Z-Pile, PS sheet pile load resistance
is transferred through tension rather than through
bending moment strength.
Panama Canal Expansion, Panama
Flat sheets are typically used for circular cellular
structure designs. This innovative mass gravity
system transfers hoop stress into the flat sheets,
which then transfers the load uniformly into the
interlock.
This PS Thumb & Finger (T&F) interlock is a three-
point contact connection that has a long proven
history and has provided superior pull strength to
withstand the large forces associated with high
retaining structures in both land and deep water.

PS Thumb & Finger Interlock

IHNC at Seabrook, New Orleans, LA


Page 5
www.lbfoster.com

Web

Width
Available Grades: ASTM A572 Gr. 50 and 60, A588 and A690
Dimensions and Properties
Nominal
Web
Width +
Weight Moment of Inertia Section Modulus Coating
Thickness+
Section Area*
in. in. lb/lft lb/ft2 in4 in4/wft in 3
in /wft
3
ft2/lft
mm mm kg/lm kg/m2 cm4 cm4/wm cm3 cm3/wm m2/lm
19.69 0.40 45.1 27.5 5.0 3.0 3.2 1.9 3.64
PS 27.5
500 10.2 67.1 134.2 207 414 52 103 1.11
19.69 0.50 50.9 31.0 5.0 3.0 3.2 1.9 3.64
PS 31
500 12.7 75.7 151.4 207 414 52 103 1.11
+
Values stated are nominal.
Both sides of sheet: excludes interior of interlock.

Grade Minimum Interlock Strength(1) Minimum Swing (2)


A328 16 kips/in. (2,800 kN/m) 10 degrees
A572-50 20 kips/in. (3,500 kN/m) 10 degrees
A572-60 24 kips/in. (4,200 kN/m) 10 degrees
Higher interlock strengths are available but obtainable swing may be reduced in interlock strengths above 24 kips/in (4,200 kN/m).
(1) These minimum ultimate interlock strengths assume proper interlocking of sheets. To verify the strength of PS sheet piling,
both yielding of the web and failure of the interlock should be considered.
(2) Swing reduces 1.5 degrees for each 10 feet (3 meters) in length over 70 feet (21 meters).

Sitran Coal Transfer Facility, Mount Vernon, IN


Page 6
®

L.B. Foster Provides a Full Line of Piling Enhancements

Services such as:


Coating
Pipe Pile Points • Coal Tar Epoxy HP Splicers
and Shoes and Points
• Fusion Bond (pipe)

• Galvanizing

• Thermal Zinc Spray

Cut to Length Pile for Orders


Pairing of PZC Pile
Truck / Rail / Barge Delivery
Interlock Sealant

Accessories

• Cutting Shoes

• Conical Points
Sheet Pile
Protectors • Backing Rings

• Splicers

• Steel Sheet Pile

• Channel Cap

Rental of Z-Pile

and much more...

Page 7
www.lbfoster.com

OPEN CELL SHEET PILE™ System

The PND patented design OPEN CELL™ bulkhead


delivers proven performance even under
extreme conditions.

• High load capacity

• Minimal toe embedment required

• Soft soils applicability Cates Landing Intermodal Ports Authority, Tiptonville, TN


(Shown during construction prior to installation of face beam and fenders.)
• Accommodates long-term settlement

• Corrosion resistance

• Insensitive to scour

• Deep water (wall height 60’+)

• Seismic conditions

• Cofferdams and heavy shoring

• Contaminated soils containment

• High capacity bridge abutments

USACE Permanent Canal Closures and Pumps Project, New Orleans, LA

Pictures courtesy of:

PND Engineers holds patents; #US-6,715,964 B2,


#US-7,488,140 B2 and #US-8,950,981 B2
on the OPEN CELL system.

*OPEN CELL™, OPEN CELL SHEET PILE™ and OCSP™ are


registered trademarks of PND Engineers, Inc. and are used
with their permission.

Tri-City Port Authority-America’s Central Port, Granite City, IL


Page 8
®

The OPEN CELL bulkhead, used primarily on docks and similar structures, is a cellular flat sheet
pile structure in which each cell’s sheet piles are driven in the shape of a ‘U’ when viewed from
above. The system functions as a horizontally tied membrane relying solely on the vertical flat
sheet pile anchor wall to restrain a curved flat sheet pile arch face. The bulkhead becomes a series of
U-shaped vertical member structures that does not require toe embedment for stability.

The OPEN CELL structure is simply constructed using PS flat sheet pile.

The standard 120° wye pile is supplied using extruded connectors or fabricated wye piles can be made
from PS sheets to accommodate project conditions. The anchor pile is made with an extruded connector
attached to either a H-pile or pipe pile.

Gerdau PS sheet pile is the ideal material for the OPEN CELL system application because it provides high
interlock tolerances and swing angles, while maintaining the necessary strength.

Cheniere Energy, Sabine Pass, LA


Page 9
www.lbfoster.com

Combi-Wall Systems

L.B. Foster Company is dedicated to providing


the most efficient combi-wall system for your
needs utilizing a variety of components.

Using wide–flange beams or pipe piles along


with extruded connectors and PZC™ sheet
pile from Gerdau, L.B. Foster is able to provide Herbert Hoover Dam, Martin & Palm Beach Counties, FL
an efficient solution to meet your project
requirements.

L.B. Foster combi-wall systems have a range


in section modulus of 50 in3/ft. to over 1,000
in3/ft. Domestic systems (100% melted and
manufactured in the USA) are available.

Freeport Water Authority, Sacramento, CA

Cabrillo Way Marina, San Pedro, CA


Page 10
®

Combi-Wall Solution Variations


L.B. Foster is dedicated to offering the most efficient combi-wall system for your needs through utilization of
our vast array of systems designed to your specific requirements.

Wide Flange with Extruded Connectors Pipe Pile with Extruded Connectors

Red Rock Hydroelectric Project, Pella, IA


Page 11
www.lbfoster.com

Pipe Pile

L.B. Foster provides a full line of pipe pile. L.B.


Foster can offer ERW, DSAW and spiral weld
pipe pile in a wide range of sizes and lengths
to meet your requirements. In addition, L.B.
Foster provides value added services such
as cutting to length, coating, accessory
attachment, and other welding to facilitate
complete pipe pile solutions.

New Jersey Department of Transportation, Brielle, NJ

Galvanized 36” OD Spiralweld Pipe Pile

USACE, Santa Maria, CA Route 70 Bridge over the Manasquan River, Brielle, NJ
Page 12
®

Pipe
Weights Wall Thickness (inches)
lbs / ft 0.219 0.250 0.312 0.375 0.438 0.500 0.625 0.750 0.875 1.000

8.625 19.68 22.38 27.73 33.07 38.33 43.43

10.75 24.65 28.06 34.81 41.59 48.28 54.79 ERW DSAW

12 27.58 31.40 38.98 46.60 54.14 61.47 76.00

12.75 29.34 33.41 41.48 49.61 57.65 65.48 81.01

14 32.26 36.75 45.65 54.62 63.50 72.16 89.36 SPIRAL WELD


16 36.95 42.09 52.32 62.64 72.86 82.85 102.72

18 41.63 47.44 58.99 70.65 82.23 93.54 116.09

20 52.78 65.66 78.67 91.59 104.23 129.45


Outside Diameter (inches)

24 63.47 79.01 94.71 110.32 125.61 156.17 186.41

26 68.82 85.68 102.72 119.69 136.30 169.54 202.44

28 74.16 92.35 110.74 129.05 146.99 182.90 218.48 253.72

30 79.51 99.02 118.76 138.42 157.68 196.26 234.51 272.43

32 84.85 105.69 126.78 147.78 168.37 209.62 250.55 291.14

34 90.20 112.36 134.79 157.14 179.06 222.99 266.58 309.84

36 95.54 119.03 142.81 166.51 189.75 236.35 282.62 328.55 374.15

38 100.89 125.70 150.83 175.87 200.44 249.71 298.65 347.26 395.53

40 106.23 132.37 158.85 185.24 211.13 263.07 314.69 365.97 416.91

42 111.58 139.04 166.86 194.60 211.82 276.44 330.72 384.67 438.29

44 116.92 145.71 174.88 203.97 232.51 289.80 346.76 403.38 459.67

46 122.27 152.38 182.90 213.33 243.20 303.16 362.79 422.09 481.05

48 127.61 159.05 190.92 222.70 253.89 316.52 378.83 440.80 502.43

54 179.06 214.97 250.79 285.96 356.61 426.93 496.92 566.57

60 199.08 239.02 278.88 318.03 396.70 475.04 553.04 630.71

66 219.09 263.07 306.98 350.10 436.79 523.14 609.16 694.85

72 239.10 287.13 335.07 382.17 476.87 571.25 665.29 758.99

78 259.11 311.18 363.16 414.24 516.96 619.35 721.41 823.13

84 279.12 335.23 391.26 446.31 557.05 667.46 777.53 887.27

90 299.13 359.28 419.35 478.38 597.14 715.56 833.65 951.41

96 319.15 383.34 447.44 510.45 637.22 763.67 889.78 1015.55

Page 13
www.lbfoster.com

H - Pile
Y k

d X X

tw
tf

Y
bf

Available Grades: ASTM A572 Gr. 50 and 60, A588 and A690

Dimensions and Properties U.S. Standard


Area Depth Web Thickness Flange Elastic Properties Surface
Width Thick X-X Axis Y-Y Axis Area per
Section Linear
Designation A d tw tw/2 bf tf lx Sx rx Iy Sy ry Foot
in 2
in in in in in in 4
in 3
in in 4
in 3
in ft2/ft

HP16x121 35.7 15.75 0.750 0.375 15.875 0.750 1578 200 6.65 501 63.1 3.75 7.62

x101 29.8 15.50 0.625 0.313 15.750 0.625 1297 167 6.60 408 52.1 3.70 7.56

x88 25.8 15.33 0.540 0.270 15.665 0.540 1112 145 6.56 347 44.0 3.66 7.52

HP14x117 34.4 14.21 0.805 0.403 14.885 0.805 1220 172 5.96 443 59.5 3.59 7.10

x102 30.0 14.01 0.705 0.353 14.785 0.705 1050 150 5.92 380 51.4 3.56 7.05

x89 26.1 13.83 0.615 0.308 14.695 0.615 904 131 5.88 326 44.3 3.53 7.00

x73 21.4 13.61 0.505 0.253 14.585 0.505 729 107 5.84 261 35.8 3.49 6.95

HP12x84 24.6 12.28 0.685 0.343 12.295 0.685 650 106 5.14 213 34.6 2.94 5.93

x74 21.8 12.13 0.605 0.303 12.215 0.610 569 93.8 5.11 186 30.4 2.92 5.89

x63 18.4 11.94 0.515 0.258 12.125 0.515 472 79.1 5.06 153 25.3 2.88 5.85

x53 15.5 11.78 0.435 0.218 12.045 0.435 393 66.8 5.03 127 21.1 2.86 5.81

HP10x57 16.8 9.99 0.565 0.283 10.225 0.565 294 58.8 4.18 101 19.7 2.45 4.89

x42 12.4 9.70 0.415 0.208 10.075 0.420 210 43.4 4.13 71.7 14.2 2.41 4.82

HP8x36 10.6 8.02 0.445 0.223 8.155 0.445 119 29.8 3.36 40.3 9.88 1.95 3.89

Page 14
®

Steel Grid Bridge Decking


L.B. Foster fabricated steel bridge decking Exodermic Bridge Decks
products’ cost-efficient grid reinforced concrete
deck and open steel grid flooring systems are easy An exodermic (or “composite, unfilled steel grid”)
to install and maintain with minimum interruption deck is comprised of a reinforced concrete slab on
to traffic during new construction or bridge repair. top of, and composite with, an unfilled steel grid.

Concrete-filled steel grid bridge decking provides Why Use An Exodermic Bridge Deck?
a far greater life expectancy than reinforced • Light Weight – An exodermic deck typically weighs
concrete and its durability resists heavy traffic, 35% to 50% less than a reinforced concrete deck
weather and deicing agents. Our lightweight, that would be specified for the same span. The
yet strong, open steel grid flooring is the answer efficient use of materials in an Exodermic deck
for movable bridges or other conditions where means the deck can be much lighter without
minimizing dead load is a major consideration. sacrificing strength, stiffness, ride quality, or
expected life.
• Rapid Construction – Precast Exodermic decks
can be erected during a short, nighttime work
window, allowing a bridge to be kept fully open
to traffic during the busy daytime hours. Panels
are quickly placed, and layout of the single mat
of rebar is simple and straightforward, without
the need for chairs or other aids in most cases.
Open Grid Cantilevered decks can be formed without
temporary supports.
• Ease of Maintenance – An Exodermic deck is
easily maintained with standard materials and
techniques,since the top portion of an Exodermic
deck is essentially the same as the top half of a
standard reinforced concrete deck.

Fully Filled Grid

Half Filled Grid


Page 15
www.lbfoster.com

Bridge Deck Sections


All bridge deck forms are produced from structural quality galvanized sheet steel conforming to ASTM
designation A-653. Finish is hot dipped galvanized conforming to ASTM designation A-924. Standard
coating weight is G165 with other weights available. Manufactured in Bedford, Pennsylvania.

2” Bridge Decking–2” deep x 8-½” pitch x 34” coverage 2-½” Bridge Decking–2-½” deep x 8” pitch x 32” coverage

34.00 32.00

Section Properties Section Properties


(per ft. of width) (per ft. of width)
Thickness Weight Thickness Weight
GAGE Ip (in4/ft) Sp (in3/ft) GAGE Ip (in4/ft) Sp (in3/ft)
(in) (psf ) (in) (psf )
22 0.0299 0.346 0.294 1.78 22 0.0299 0.539 0.400 1.90
21 0.0329 0.381 0.324 1.95 21 0.0329 0.597 0.436 2.07
20 0.0359 0.416 0.355 2.11 20 0.0359 0.651 0.476 2.24
19 0.0418 0.484 0.412 2.43 19 0.0418 0.758 0.554 2.58
18 0.0478 0.553 0.471 2.76 18 0.0478 0.867 0.634 2.93
17 0.0538 0.622 0.530 3.08 17 0.0538 0.976 0.713 3.27
16 0.0598 0.691 0.588 3.41 16 0.0598 1.084 0.793 3.62

3” Bridge Decking–3” deep x 8” pitch x 24” coverage 4-½” Bridge Decking–4-½” deep x 12” pitch x 24”
coverage
24.00 24.00

Section Properties Section Properties


(per ft. of width) (per ft. of width)
Thickness Weight Thickness Weight
GAGE Ip (in4/ft) Sp (in3/ft) GAGE Ip (in4/ft) Sp (in3/ft)
(in) (psf ) (in) (psf )
22 0.0299 0.841 0.459 2.33 20 0.0359 1.886 0.653 2.75
21 0.0329 0.983 0.537 2.54 19 0.0418 2.425 0.840 3.17
20 0.0359 1.113 0.608 2.75 18 0.0478 3.018 1.045 3.60
19 0.0418 1.296 0.708 3.17 17 0.0538 3.607 1.249 4.02
18 0.0478 1.483 0.810 3.60 16 0.0598 4.009 1.388 4.45
17 0.0538 1.669 0.911 4.02
16 0.0598 1.855 1.013 4.45

22 gage through 17 gage formed from A-653 Grade 50 or Grade 80 steel.


16 gage through 14 gage formed from A-653 Grade 40 steel.
Weights based on G165.
Page 16
®

Bridge Deck Form Details


Top Flange Tension - Interior Girder Top Flange Tension - Exterior Girder

Top Flange Compression - Interior Girder Concrete Beam

Aluminum Bridge Decking


Advanced design aluminum bridge decking technologies offer unmatched advantages over traditional
concrete and steel construction.

• Lightweight structural aluminum to reduce dead-load.


• Prefabricated for accelerated bridge construction.
- Minimizes traffic interruptions and need for expensive traffic
control.
• 100 year bridge life potential.
• Lower life cycle costs.
• Advantages over existing deck alternatives:
- Corrosion resistant with minimal maintenance - no painting.
- Better skid resistance and less road surface noise compared to
grid decks.
- Capable of a 3.5’ cantilever on each side of bridge to widen
roadway.
- Simple mechanical connections for fast installation and easy
inspection.
- Damaged deck panels can be quickly replaced.
L.B. Foster is an authorized distributor of AlumaBridge, LLC., aluminum orthotropic
and isotropic bridge deck.
www.alumabridge.com Page 17
www.lbfoster.com

Bridge Railing Systems

L.B. Foster Fabricated Bridge Products is the one


source for all your bridge railing needs. We are
the nation’s leading fabricator and supplier of
aluminum bridge railing products. Each of our rail
systems is fabricated to the exact requirements of
state highway departments and other specifying
agencies. L.B. Foster can supply bridge and
pedestrian railings with special finishes, including
hardcoat anodizing, critical paint specifications
or galvanizing.

Page 18
®

PRODUCT GROUP ENGINEERING

Houston, Texas Suwanee, Georgia


P# 936-228-0077 P# 678.926.5209

SALES

ATLANTIC SALES DISTRICT / EASTERN CANADA GULF SALES DISTRICT / INTERNATIONAL

Quakertown, Pennsylvania Houston, Texas


P# 215.536.8460 P# 936-228-0077

Boston, Massachusetts New Orleans, Louisiana


P# 215.536.8460 P# 504.887.2717

Atlanta, GA Orlando, Florida


P# 678.926.5217 P# 407.679.4810

GREAT LAKES SALES DISTRICT / CENTRAL PACIFIC SALES DISTRICT / WESTERN CANADA
CANADA

Chicago, Illinois Union City, California


P# 630.320.1370 P# 510.240.4400

Denver, Colorado Anaheim, California


P# 303.503.3758 P# 949.788.1074

Page 19
www.lbfoster.com

Page 20
Bunge North America - Destrehan, LA
Steel grid bridge decking used in the design of
a new ship loading system.

Photo Courtesy of Boh Bros. Construction Co.


L.B. Foster Offers a Variety of Construction Products
• Steel Sheet Pile
• Engineered Solutions
• Pipe Pile
• H-Pile/Structurals
• Piling Accessories
• Fabricated Bridge Decking and Railing Systems

lbfoster.com
Version 18
Sept. 2019

You might also like