A. Reference Information
REFERENCE DESIGNATION
TASK 24−00−00−910−801 Electrical/Electronic Safety Precautions
3. Job Set−Up
Subtask 24−32−00−910−002
4. Procedure
Subtask 24−32−00−710−003
(a) On the engine and system integrated display control panel (ESCP), set the knob
MFD1 to the SYS position.
NOTE: The ESCP is in the center console.
(b) On the ESCP, push the ELEC SYS push−button. Make sure that the electrical page is
on the MFD.
(6) On the MFD, make sure that voltage shows only on the L ESS and R ESS DC BUS displays
Subtask 24−32−00−710−001
Subtask 24−32−00−710−004
Subtask 24−32−00−710−005
(3) On the DC CONTROL panel, set the MAIN BUS TIE switch to the MAIN BUS TIE position.
(4) On the MFD, make sure that voltage shows only on the L MAIN, R MAIN, L ESS and the R
ESS DC BUS display.
(5) On the MFD, make sure that the BATT AUX display shows the approximate ambient
temperature.
(6) On the MFD, make sure that the BATT AUX LOAD display shows a maximum value of 1.00.
(7) On the DC CONTROL panel, set the AUX BATT and the MAIN BUS TIE switch to the OFF
position.
Subtask 24−32−00−710−006
E. On the DC CONTROL panel, set the BATTERY MASTER switch to the OFF position.
5. Close Out
Subtask 24−32−00−941−009
A. Remove all tools, equipment, and unwanted materials from the work area.