Comparative Study

Venturi® Combo by-Pass Filtration with StrataPore™ + Cellulose

250

200
ByPass Organic

Used Combo LF
G r a m s o f C o n ta m in a n t
150 ByPass Inorganic

100 Full-Flow Organic

50 Full-Flow Inorganic

StrataPore media provides:


 Generally 30µ (98.7% efficiency)
 Approximately 60% of the contaminant is trapped in by-pass Filtration

filter although the by-pass is only 33% of the physical filter  High Capacity for Organic
Contaminants - Sludge
volume  Low Flow Restriction - especially at
 Over 80 % of the contaminant is organic (sludge) SAE cold-start
 Cost Effective Filtration for more
972957-Applies to older engines Demanding Systems
2
FLEETGUARD – LF3000

3
FG LF14000NN Vs DON P559000
LF14000NN P559000

295.86
300
Single Media

118.6 118
Full Flow – Synthetic Media + Cellulose
Media Architecture 2 Media – Stratapore + NanoNet Media
backing
Dust Holding Capacity 100g 89g
Efficiency 99% @ 30 Micron 99% @ 30 Micron
72% @ 10 Micron 66% @ 10 Micron
Yes (NanoNet media increases dust holding
Extended Service Interval May not be able to provide ESI
capacity)
Nanofiber and Stratapore media(less
Cold Flow Ability Single media is used
restriction,faster oil lubrication on cold start up)

4
FG FS1006 Vs DON P552006
FS1006 P552006

Standpipe

311
314.2
CF Filter Media:
10 micron startapore

118
120.3

Media Architecture Stratapore Media Synthetic Media


Dust Holding Capacity 165g 130g
Standpipe Yes No
Emulsified Water Separation 95% < 95%
Free Water Separation 95% 95%
Efficiency, TWA BY SAE J 1985 98.70% -
Micon Rating BY SAE J 1985 10 micron 10 micron
5
FG WF2072 vs DON P554072
Compact SCA Pellets WF2072 P554072

SCA Powder
(big solid
particles)

Stains on DON media

Media Architecture Cellouse Media Cellouse Media


Micron Rating 22um 50um
Coolant Additive SCA pellet SCA Powder

Coolant Additive Form Compact pellets Powder with big solid particles

Stains on media due to SCA


Media No Stains on media
powder and media damage
Shell Thickness 0.51 mm 0.48 mm
6
FG LF16015 vs BALD BT 7327

Stratapore™ Media
Media Architecture Stratapore Media Synthetic Media + Cellulose backing Synthetic / Cellouse
Dust Holding Capacity 20g -
Efficiency 97% @ 30 Micron -
Yes (media increases dust holding
Extended Service Interval May not be able to extend Service life
capacity)

Stratapore media(less
Media used might restrict cold start due to
Cold Flow Ability restriction,faster oil lubrication on cold
restriction
start up)
7
Q+A

8
9