mate for the proposed residential building

Column1 Column2
Column3Column4Column5 Column6 Column7
No Description of work No Length Breadth Height Qty Remark
1 Earth work excavation in hard soil 1 10.23 0.60 0.60 3.68
3 7.06 0.60 0.60 7.62
1 8.14 0.60 0.60 2.93
1 5.90 0.60 0.60 2.12
1 1.45 0.60 0.60 0.52
3 2.58 0.60 0.60 2.79
1 2.62 0.60 0.60 0.94
20.61
2 DR masonry for foundation 1 10.23 0.60 0.60 3.68
3 7.06 0.60 0.60 7.62
1 8.14 0.60 0.60 2.93
1 5.90 0.60 0.60 2.12
1 1.45 0.60 0.60 0.52
3 2.58 0.60 0.60 2.79
1 2.62 0.60 0.60 0.94
20.61
3 RR masonry for basement 1 10.03 0.45 0.45 2.03
1 7.99 0.45 0.45 1.62
3 7.61 0.45 0.45 4.62
1 5.90 0.45 0.45 1.19
1 1.59 0.45 0.45 0.32
3 2.73 0.45 0.45 1.66
1 2.7 0.45 0.45 0.55
11.99
4 Brick masonry for walls 3 7.82 0.24 3.00 16.89
2 9.82 0.24 3.00 14.14
1 5.90 0.24 3.00 4.25
3 2.94 0.24 3.00 6.35
1 2.98 0.24 3.00 2.15
Deduction
doors d1 -4 0.90 0.24 2.10 -1.81
doors d2 -2 0.80 0.24 2.10 -0.81
doors d -1 1.00 0.24 2.10 -0.50
windows w -4 1.50 0.24 1.50 -2.16
windows kw -1 1.50 0.24 1.20 -0.43
ventilator v -3 0.75 0.24 0.75 -0.41
37.65
5 RCC for plinth beam 3 7.82 0.30 0.10 0.70
2 9.82 0.30 0.10 0.59
1 5.90 0.30 0.10 0.18
3 2.94 0.30 0.10 0.26
1 2.98 0.30 0.10 0.09 1.82
RCC for lintel 3 7.82 0.24 0.15 0.84
2 9.82 0.24 0.15 0.71
1 5.90 0.24 0.15 0.21
3 2.94 0.24 0.15 0.32
1 2.98 0.24 0.15 0.11
4.01
RCC for sunshde

RCC for roof slab

8.03