You are on page 1of 3

P R O D U C T I N F O R M AT I O N

HMB Spring Hydraulic Mechanism


Most compact and reliable

HMB is the most compact and


reliable operating mechanism for the
proper operation of gas insulated
high voltage circuit breakers.


01 HMB 08 operating HMB operating mechanisms are designed for reliable HMB operating mechanisms adapt easily to varying
mechanism switching of high voltage circuit breakers from 72.5 breaker types and ratings. Compact size and unique
kV to 800 kV. installation principles facilitate shipping with the
mechanism installed on the breaker for most ratings
Circuit breakers are a critical component providing lowering installation and commissioning time and
switching and short circuit protection across the cost.
electrical network. The operating mechanism ensures
proper operability of the breaker for its particular Applications
application. • AIS Dead Tank Breaker 72.5-800 kV

How does the HMB spring hydraulic mechanism


compare to other styles?

Pneumatic operating Hydraulic operating Spring operating Spring hydraulic


mechanism mechanism mechanism operating mechanism
Number of moving
Minimum Minimum Higher Minimum
parts

Size Extensive Extensive Medium Very compact

Maintenance Intensive Minimum None None



Ease of use
• Limited number of moving parts, modular design
• Quick and easy field replacement or upgrade (if necessary)
• Minimizes overall footprint of the assembly with less complex
installation and timing
• Breaker ships with mechanism installed on breaker (except 245 kV,
50-90 kA)
• Less control power required than comparable mechanism with
similar energy (only 5 ampere)
• No parts requiring lubrication
• Minimum scheduled maintenance for 10,000 CO operations


Reliability
• Spring assemblies do not relax over time
• No external dampening system to wear or that requires adjustment
• Smooth deceleration of the breaker
• No adjustments required during commissioning of the breaker
• No overcharging due to built-in bypass valve protection
• Point-on-Wave switching for critical applications (e.g. capacitor
bank switching)
• Temperature independent energy storage ensuring proper
operation in all ambient conditions


Safety
• Modular and service-friendly design with easily accessible modules
• Spring assemblies will not fail catastrophically
• No latches or gears limiting pinch points (one)
• Operates under abnormal conditions, as long as it is charged

Modular design

Auxiliary switch assembly and control circuit


• For signaling of the switching state

Charging module
• Hydraulic pump with motor for charging the storage
module

Control module
• Main valve operating the working module
• Includes the coils for initiating the switching operation
• individual adjustable switching speed and timing

Monitoring module
• Spring travel switch for monitoring the status of the
stored energy
• Spring limit switch to govern the charging of the
springs

Working module
• Main cylinder with piston rod operating the circuit
breaker
• Integrated end position damping

Storage module
• Spring assembly and storage cylinders
• Storing the energy for the switching operation

Disc spring column

2GNL010010_REVA - 09.2018

— —
ABB, Inc. We reserve the right to make technical We reserve all rights in this document and in
Dead Tank Circuit Breakers changes or modify the contents of this the subject matter and illustrations
100 Distribution Circle document without prior notice. With regard contained therein. Any reproduction,
Mt. Pleasant, PA 15666 to purchase orders, the agreed particulars disclosure to third parties or utilization of
Phone: +1 724-696-1500 shall prevail. ABB Inc. does not accept any its contents – in whole or in parts – is
­responsibility whatsoever for potential forbidden without prior written consent of
errors or possible lack of information in this ABB Inc. ­Copyright© 2018 ABB
document. All rights reserved
abb.com/highvoltage

You might also like