You are on page 1of 25

SHOPPING MALL

SERVICES DATA

2018-ARCH-27
2018-ARCH-25
SERVICES

ESCALATORS AND ELEVATORS


• Escalators are widely used to transport large numbers of people over
a relatively short vertical distance.
• A single escalator has the same capacity as a large bank of elevator.
• The advantages of the escalator over the elevator are a greater passenger
capacity
• In case of speed elevators have more speed as compared to escalators.
Typical carrying capacities of escalators
and walkways
Escalator dimensions
RECOMMENDED LOBBY DIMENSIONS FOR
VARIOUS LAYOUTS OF ELEVATOR GROUPS
ELEVATORS TYPES AND
DIMENSIONS ACCORDING
TO ITS CAPACITY
Shopping mall service

HVAC
HVAC SYSTEM SELECTION

 System efficiency
 Building application
 Capital cost versus payback period
 System longevity
 System flexibility
 Location
 Plant room space available
Basic central HVAC system types
Air conditioning and air quantities for various
building types
PLUMPING SYSTEM

 Plumping system: means the water supply and distribution pipes, plumbing fixtures and
traps, soil, waste, and vent pipes, sanitary and storm sewers and building drains.
 The size and the type of plumping system depend on the building size and type .
 Types of plumping system:
 Single stack system
 Partially vented single stack system
 One-pipe system
 Two-pipe system
ELECTRICAL ROOMS

 It’s a room or a space in a building dedicated to electrical equipment.


 Minimum requirements set for the National Fire Protection Association (NFPA) in the
National Electric Code (NEC) is that a person must be able to complete service duties with
enclosure doors open and for two people to pass one another.
 Installations over 600 volts require even wider aisle space, from 3 feet to as much as 12
feet for voltages above 75kV. Service rooms with 1,200 amps or more require two exits in
case of fire.
 Electrical room Located in service areas not in public areas for safety of people.
Single or Multiple
Utility Meter
Configuration:

 An electrical gear rated up to 800


amperes may require a minimum
of eight (8) feet in length in a
single utility meter set up. A similar
gear with multiple meters serving
multiple tenants could be up to
twenty (20) feet in length,
depending on the individual
service sizes to the tenants
themselves.
GARBAGE COLLECTION SYSEM

 GARBAGE CHUTES
 Garbage chutes are mechanisms that consolidate trash from each floor of a building – or
select floors of each building – via a chute, allowing all trash to collectively compile in a
singular location.

 SIZES:
WORKSTATION

Workstation for 8 persons required


minimum space 448 sq.ft and
maximum space 1012 sq.ft.
WORKSTATION LAYOUTS
BUBLIC TOILETS
PUBLIC TOILETS
PUBLIC TOILETS
ELECTRICAL ROOM
FIRE SAFETY

Fire safety is the set of practices and measures that intended to reduce destruction caused
by fire. There must be use of :
Fire detectors in building
Mechanical smoke extractors
Fire resistant material
Water sprinklers
Extinguisher water pipeline
Dry chemical powder 6
Kg Fire Extinguishers for each 2000 square feet of floor area.
Co2 extinguisher system. The distance between any two
hydrants shall not exceed more than 100 feet.
EMERGENCY EXITS
• Distance between two fire exits 228 ft.
• Provision on every side and level of the building.
THANK YOU