You are on page 1of 2

CU 6552 4P / 2x4P F8

Data cable, F/FTP, Category 6A , AWG 23, Euroclass Cca

1 Inner conductor: AWG23 Bare copper wire


2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Drain wire: Tinned copper wire
5 Overall screen: Alu PETP foil
6 Outer sheath: FRNC/LS0H orange RAL 2003

DESCRIPTION
Electrically and mechanically improved quality Cat.6A data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and prEN 50288-10-1.
Excellent shielding effect due to individually screened pairs and overall foil screen.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.

APPLICATION

Data cable for structured premises cabling.


For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class EA applications (500 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.

GRAPH

ELECTRICAL CHARACTERISTICS

Category 5e 6 6A
Frequency [MHz] 1 4 10 100 250 500
Attenuation [dB/100m] 2.1 3.8 5.9 19 30 43
NEXT [dB] 93 93 93 93 83 75
PS NEXT [dB] 90 90 90 90 80 72
ACR-N [dB] 91 89 87 73 53 32
PS-ACR-N [dB] 88 86 84 70 50 29
ACR-F [dB] 96 96 96 74 56 33
PS-ACR-F [dB] 93 93 93 71 53 30
Return loss [dB] 26 28 30 30 27 21
These performance data are typical measured values.

As of 09.10.2020 Subject to technical modification.


CU 6552 4P / 2x4P F8
Data cable, F/FTP, Category 6A , AWG 23, Euroclass Cca

ELECTRICAL PROPERTIES

Category: Cat.6A
Coupling attenuation: 70 dB
Delay Skew: 5 ns/100 m
Impedance at 100 MHz, ±5Ω: 100 Ω
Loop resistance at 20°C: < 150 Ω/km
Near end unbalance attenuation LCL at 1-600 MHz: 40 dB
NVP %: 79
operating capacity: 42 pF/m
Transfer impedance 1/10/30 MHz: < 50/100/200 mΩ/m

MECHANICAL PROPERTIES

Minimum bending radius during installation: 56 mm


Minimum bending radius permanently installed: 28 mm
Tensile strength (4P): 95 N
Tensile strength (2x4P): 190 N
Minimal crush resistance / 10cm: 1,000 N
Minimum number of impacts: 10
Installation temperature: 0 °C - +50 °C
Operating temperature: -20 °C - +60 °C

STANDARDS

Reaction to fire (Euroclass) EN 13501-6: Cca


Wire colour white/bluewhite/orangewhite/greenwhite/brownin accordance with IEC 60189 and IEC 60708
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
Zero halogen, no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
PoE IEEE 802.3af
EMC shielded
Segregation class c
Cat./Class Cat 6A / Class EA - limit values as specified by IEC 61156-5 and EN 50288-10-1 guaranteed

VERSIONS

Article No. DoP Product Reaction to fire Dimensions n x p x [mm Sheath Sheath Sheath Ø Weight Cu rate Fire load Fire load PU
(Euroclass) (AWG)] colour [mm] [kg/km] [kg/km] [MJ/m] [kWh/m]
19145400CK CU 6552 4P Cca-s1a,d1,a1 4 x 2 x 0.55 (AWG23) FRNC/LS0H orange 7 49 20.0 0.52 MJ/m 0.14 1000 m
drum
19145600CL CU 6552 Cca-s1,d1,a1 2 x (4 x 2 x 0.55 (AWG23)) FRNC/LS0H orange 7.0 x 14.3 98 40.0 1.04 MJ/m 0.28 500 m
2x4P drum

As of 09.10.2020 Subject to technical modification.