You are on page 1of 10

H I G H VO LTAG E P R O D U C T S

Horizontal double break disconnector


Type eDB, up to 420 kV

• Minimized contact resistance


• Easy and quick erection
• Low friction design for
smooth operation
• Ice breaking capacity
• Strong rotary pedestals
• Minimal maintenance
2 H O R I Z O N TA L D O U B L E B R E A K D I S C O N N E C T O R P R O D U C T B R O C H U R E


ABB offers a wide range of
reliable and energy efficient
disconnectors to meet the
requirements of different sites
and network conditions.
The disconnectors range from
72.5 kV to 420 kV.

ABB disconnectors are designed


as per IEC 62271-102 and
IEC 62271-1 standards.
3


Table of contents

04  Disconnectors from ABB


Applications
Regulations

05 Maximum reliability and


minimal maintenance

06 Technical data

07 Mode of operation

08 Easy installation
Main dimensions (mm)
Series installation
4 H O R I Z O N TA L D O U B L E B R E A K D I S C O N N E C T O R P R O D U C T B R O C H U R E


Disconnectors from ABB
ABB HV Disconnectors are in operation across the world in extreme
and adverse conditions for decades, providing maintenance-free
service with the highest benchmarks for operational reliability.


Electric sub-station
Applications Regulations
A mechanical device for providing isolation of The eDB Disconnectors are designed as per
power equipment from the network, IEC 62271-102 and IEC 62271-1 standards.
a disconnector is suitable for switching Other international regulations can be met on
very small currents or where no significant request. Type tests on the disconnectors are
change in voltage occurs across the terminals. carried out by accredited testing laboratories
The option of earthing sections of power systems in accordance with the latest regulations.
can be made available by providing Comprehensive electrical and mechanical routine
each disconnector pole with one or two tests are carried out on the poles and operating
earthing switches. mechanism of each disconnector, ensuring
world-class quality.
5


Maximum reliability and
minimal maintenance

— Minimized contact resistance Suitable for a wide range of environmental


02
Fixed contact and (energy efficient solution) conditions
terminal pad of The current carrying aluminium conductors have The disconnectors can operate in a wide range of
1600 A eDB
no joints to minimize circuit resistance. temperatures as well as under polluted
environmental conditions.
No external springs in contact fingers
for maximum reliability Minimal maintenance
The contact fingers of the moving contacts of Superior material and lubricant used in the
disconnector type eDB are designed from special encapsulation of the pedestals makes the
conducting material and without external springs disconnectors practically maintenance-free.
for increased reliability.
Design based on cutting-edge technology
Easy and quick erection and experience
The current carrying conductors and rotary The horizontal double break disconnectors type
pedestals are designed for easy adjustment eDB consist of a steel base frame with one rotary
and alignment. pedestal, insulators, current carrying conductors
(current path) and driving mechanisms. Steel
Low friction design for smooth operation components are hot dip galvanized to protect
Maintenance-free linkages with stainless steel against atmospheric influences. Each of the
rod-end bearings require less drive power for three phases of the disconnector consists of
operation and provide smooth motion one insulator mounted on maintenance-free,
transmission without any disturbance in the sealed rotary pedestal and two support
settings. insulators which support terminal pads and fixed
(Corrosion – free electrical and mechanical joints) contacts which are carried by the steel base
frame. The current transfer takes place between
Dead centre interlocking for reliability two stationary terminal pads. When closed,
under extreme conditions the contact fingers glide over the fixed contact,
The dead centre interlocking of operating which establishes connection between the
mechanisms ensures that there are no high- voltage terminal pads. Flat terminal plates
inadvertent changes in the open or close can be provided as per DIN standard 46203,
switching position even under extreme external NEMA or any other standard.
conditions such as storms, earthquakes etc.

Superior design of mechanical interlock


The mechanical interlock between the earthing
switch and main blade is designed in such a way
that there is no scope for malfunction.

Ice breaking capacity


The disconnectors are capable of operating under
severe ice conditions.

Strong rotary pedestals


This ensures that the deflection remains

unchanged at high mechanical loads. 02
6 H O R I Z O N TA L D O U B L E B R E A K D I S C O N N E C T O R P R O D U C T B R O C H U R E


Technical data


03 Voltage 72.5 kV * 123 kV 145 kV 170 kV 245 kV 300 kV 362 kV 420 kV
145 kV eDB disconnector
Type designation eDB72.5 eDB123 eDB145 eDB170 eDB245 eDB300 eDB362 eDB420
Rated voltage (Ur) kV 72.5 123 145 170 245 300 362 420
Rated frequency (fr) Hz 50/60
Rated normal current (Ir) A 1600, 2500
Rated short-time
withstand current,
kA, s 40/50/63, 1***
rated duration of
short circuit (Ik,tk)
Rated peak withstand 2.5x Ik (for 50 Hz) / 2.6x Ik
kAp
current (Ip) (for 60 Hz)
Basic insulation level
Power frequency withstand
voltage for 1 minute
To earth and between poles kV 140 230 275 325 460 395 450 520
Across the isolating
kV 160 265 315 375 530 435 520 610
distance
Lightning impulse
withstand voltage

To earth and between poles kVp 325 550 650 750 1050 1050 1175 1425

Across the isolating 1050 1175 1425


kVp 375 650 750 860 1200
distance (+170) (+205) (+240)
Switching impulse
withstand voltage
To earth and between poles kVp - - - 850 950 1050
Across the isolating 700 800 900
kVp - - -
distance (+245) (+295) (+345)

* 36 kV on demand

** Higher currents on request

*** 3s for 40 kA


03
7


Mode of operation


04
The disconnector and earthing switch are Interlocks
Linkages with operated via independent operating mechanisms. The disconnector and earthing switch
spherical bearings
(when supplied) are mechanically interlocked.
— The operating energy from the operating In operating mechanisms, a blocking magnet
05
Bearing on frame
mechanism of the disconnector is transmitted can be installed as an additional interlocking
assembly via operating rod to the rotary pedestal. The facility, which in disconnected condition,
three phases of the disconnector are connected makes operation of the operating mechanism
by gang operating linkages for three phase impossible.
operation. During opening and closing operation,
the current path, mounted on rotary insulator Earthing switch unit
rotate through an angle of approximately 76°. The earthing switch unit, an optional assembly,
consists of a hinged-type earthing switch fixed at
Operating mechanism the base frame. The unit can be mounted on
All disconnectors can be supplied by manual or either of the contact sides or on both sides as
motor operated mechanism, as required by the required.
customer. Each three-pole disconnector or
earthing switch group requires only one / In case of the earthing switch, the operating
individual operating mechanism(s). The coupling energy is transmitted to the earthing switch
rods between the individual poles can be shaft. The tubular contact arm swings upward
continuously adapted. when the unit is closing.

Operating mechanisms contain auxiliary switches


for control and signalling as well as provisions for
electrical interlocks. Three-phase operation is
conducted via mechanical or electrical
gang operation.

For maximum reliability, the main contacts of the


disconnector and earthing switch pass through
the dead centre positions shortly before they
reach the end positions. This prevents accidental
opening or closing of the units due to external
influences (e.g. short-circuit, storm, earthquake).

— —
04 05
8 H O R I Z O N TA L D O U B L E B R E A K D I S C O N N E C T O R P R O D U C T B R O C H U R E


Easy installation
The disconnectors are delivered in following assemblies - leads and the electrical connection leading to the operating
lower part with rotary pedestals and operating rod, current mechanisms is required at the site. Stud bolts are provided
path, support insulators and operating mechanism. As all to compensate rapidly and exactly any inaccuracies
mechanical adjustments are carried out in the factory, in insulator position caused due to tensile forces.
only mounting of the assemblies, installation of the coupling
rods between the poles, connection of the high-tension


Parallel installation

Pmin Pmin
70
°


Series installation

Main dimensions as in drawing (mm / inch)

Voltage (kV) 72.5 123 145 170 245 300 362 420
Dimensions
Type eDB72.5 eDB123 eDB145 eDB170 eDB245 eDB300 eDB362 eDB420

Support insulator
A 1230/(484) 1720/(677) 1720/(677) 2200/(866) 2800/(1102) 2800/(1102) 4800/ (1890) 4800/(1890)
distance (mm)
B Base frame length (mm) 1510/(594) 2000/(787) 2000/(787) 2600/(1024) 3200/(1260) 3200/(1260) 5230/(2059) 5230/(2059)

C Insulator height (mm) 770/(303) 1220/(480) 1500/ (591) 1700/(669) 2300/(906) 2300/(906) 3650/(1437) 3650/(1437)
D Disconnector height (mm) 975/(384) 1665/(656) 1745/(687) 1930/(760) 2550/(1004) 2550/(1004) 3960/(1559) 3960/(1559)
Earth switch attachment le
E 375/(148) 375/(148) 375/(148) 400/(157) 400/(157) 400/(157) 450/(177) 1100 / (433)
ngth (mm)
Minimum distance between
poles (mm)
P
- Parallel arrangement 1750/(689) 1750/(689) 2330/(917) 3520/(1386) 3430/ (1350) 4755/(1872)
- Series arrangement 2700/(1063) 3150/(1240) 3530/(1390) 4920/(1937) 5350/(2106) 6925/(2726)
9

abb.com

ABB India Limited
High Voltage products
Maneja, Vadodara 390 013, India
Phone: +91-265-2638930
Email: pt-exports.inabb@in.abb.com

abb.com/highvoltage

1HDB050024-YN, Rev D 09/2017 Three-Column Rotary Disconnector Type eDB

© Copyright 2019 ABB. All rights reserved.


Specifications subject to change without notice.

You might also like