HCV-2, HCV-4, HCV-8

CONVENTIONAL FIRE ALARM CONTROL PANEL


STANDARD FEATURES

• Fully compliant with & tested to BS EN54-2 and


BS EN54-4
• 2-wire Annunciator
• Fully programmable using simple menu options
• Simple, single board construction
• Installer friendly
• Compatible with wide range of detection devices
• Two monitored NAC outputs
• 3 Amp power supply
• Auxiliary power output
• Adjustable sounder delay time
• NAC configuration options
• Zonal NAC delay detectors only
DESCRIPTION • Zonal NAC delay call points only
• Coincidence input selection
• I.S. Barrier selection by zone
The HCV series is available in a 2, 4, 8 Zone
conventional panel design which is in accordance • Short circuit fire by zone
with BS EN54-2 and BS EN54-4 Detection and Fire • Non latching zones
Alarm Systems – Control and Indicating Equipment. • Silent zones
• Zone input delay
The HCV series has an integrated Power Supply and
Battery charging circuit. The control panel has
“Voltage Free” Contacts for Fire and Local Fire which
operate upon a fire condition. These are used for
local control and signaling. In accordance with BS
PRODUCT LISTING
EN54-4.

The HCV series are fully programmable using simple


menu options. The Panel is a single board
construction, which is installer friendly. Compatible
with a wide range of detection devices. Remote
control input terminals for Silence Alarm, Sound
Alarm, Trouble and Reset.

http://BaoMinhGroup.com: Chuyên phân phối Trung Tâm Báo Cháy HOCHIKI HCV-2, HCV-4, HCV-8 tại Việt Nam.
Liên hệ đặt hàng: 0909 018 089 - Email: info@baominhgroup.com
Continued on back.
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0094 02/2010
Trung tâm báo cháy HOCHIKI HCV-2, HCV-4, HCV-8
SPECIFICATIONS
Supply Voltage 120VAC (50hz/60hz) or 220VAC (50hz/60hz)
Power Supply DC Rating 24V 3 Amps
Mains Supply Fuse 1.6 Amp 250V
Dimensions 385mm(W) x 310mm(H) x 92mm(D)
Weight 11.5 lbs.
Color Red
Material 1.2mm mild steel
Max. Battery Size 7Ah 12V (2 per panel)
Fault Contact Rating 30VDC 1 Amp
Local Fire Contact Rating 30VDC 1 Amp
Fire Contact Rating 30VDC 1 Amp
NAC Output Rating 0.5A per output (max 1.6A over all outputs)
Detection Zone Current 1.6mA
Detection Zone 6K8 5%
End of line resistor
Sounder Output 10K 5%
Stand by Current HCV-2: 0.065Amp, HCV-4: 0.075Amp, HCV-8: 0.093Amp
Alarm Current HCV-2: 0.1Amp, HCV-4: 0.21Amp, HCV-8: 0.55Amp
End of line resistor
Cable Capacity 2.5 mm per terminal
Operating Humidity 95% (non condensing)
Operating Temperature -5°C to +50°C

HOCHIKI AMERICA COMPATIBLE DEVICES


MODEL DESCRIPTION MAX. # PER ZONE
DETECTORS
SLR-24V/-24VN Photoelectric high velocity smoke detector 25
SLR-24H Photoelectric smoke detector 25
SLR-835H/ -835HW Photoelectric 8-35V smoke detector with Heat 25
SLR-835/-835W Photoelectric 8-35V smoke detector 25
SLR-835-BH-2W Photoelectric 8-35V smoke detector with Heat 25
SIJ-24 Ionization smoke detector 25
DFE-135 135° Fixed temperature heat detector 25
DFE-190 190° Fixed temperature heat detector 25
DCD-135 135° Fixed temperature rate of rise heat detector 25
DCD-190 190° Fixed temperature rate of rise heat detector 25
DSC-EA Rate of rise heat detector 25
SLV-24/-24N Photoelectric smoke detector 25
BASES
NS6-224 6" base, 43mA draw, 24V 25
NS4-224 4" base, 43mA draw, 24V 25
NS4-100 4" base, 24V 25
NS6-100 6" base, 24V 25
PULL STATION
HPS-SAK/HPS-DAH Conventional Manual Pull Station 32
HPS-SAH/HPS-DAK
PPE-2(JE) Call Point 32
BEAM DETECTORS
SPC-24 Beam detector 8
SRA-24 Reflective beam detector 5
NOTIFICATION DEVICES
GENTEX
GES24-1575WR Horn/Strobe 8
GEC3-24WR Horn/Strobe 8
WGEC-2475WR Horn/Strobe 10
AMSECO/POTTER
SH24W-153075R Horn/Strobe 8
SH24-75110R Horn/Strobe 8
SL24W-153075R Horn/Strobe 8
MBA-6 6" Motor Driven Bell, 24VDC 4
HOCHIKI
FBB-1501 6" Alarm Bell, 24VDC 4

Hochiki America Corporation CONVENTIONAL FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
SOC-24VN PHOTOELECTRIC SMOKE DETECTOR

APPLICATIONS
The SOC-24VN is a reliable, high quality Photoelectric Smoke
Detector. It can be used in all areas where Photoelectric
Smoke Detectors are required. The computer-designed
smoke chamber makes the SOC-24VN well suited for
detecting smoldering fires as well as fast-flaming fires.
NS-4 Series, NS-6 Series, HSC-4R or HSC-R Style bases
may be used with the SOC-24VN.

STANDARD FEATURES OPERATION

 Computer-designed non-directional smoke chamber The SOC-24VN photoelectric smoke detector utilizes one
bicolored LED for indication of status. In a normal standby
 360° view of detector status LED condition the LED flash Green every 3 seconds. When the
detector senses that its sensitivity has drifted outside the UL
 Low profile, 2" high (with base) listed sensitivity window the LED will flash Red every 3
seconds. When the detector senses smoke and goes into
 2 or 4 wire base compatibility, relay bases available alarm the status LED will latch on Red.
 Highly stable operation, RF/Transient protection The detector utilizes an infrared LED light source and silicon
 Low standby current, 59μA at 24VDC photo diode receiving element in the smoke chamber. In a
normal standby condition, the receiving element receives no
 One built-in power/sensitivity supervision/alarm LED light from the pulsing LED light source. In the event of a fire,
smoke enters the detector smoke chamber and light is
 Automatic Sensitivity window verification function meets reflected from the smoke particles to the receiving element.
outlined requirements in NFPA 72, Chapter 2 & 7, The light received is converted into an electronic signal.
Inspection, Testing and Maintenance.
Fire Judgement signals are processed and compared to a
 Without Reed switch reference level, and when five consecutive signals exceeding
the reference level are received within a specified period of
time, the time delay circuit triggers the SCR switch to activate
the alarm signal. The status LED light continuously during the
alarm period.

Light Source GaAIAs Infrared Emitting Diode


Nominal Rated Voltage 24 VDC
Working Voltage 8 - 35.0 VDC
Maximum Voltage 42 VDC
Supervisory Current 59µA @ 24 VDC
Surge Current 160µA max. @ 24VDC
Alarm Current 150mA max. @24 VDC
Air Velocity Range 0-4000 fpm
Maximum Humidity 95% RH Non-Condensing
Ambient Temperature 32°F to 120°F (0°C to 49°C)
Color & Case Material Bone PC/ABS Blend
Sensitivity Test Feature Automatic Sensitivity window PRODUCT LISTINGS
verification test
California State
Mounting Refer to NS Conventional Detector Fire Marshal
Base Data Sheet Pending
S1383

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714-522-2246 Fax: 714-522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0216 01/2017
SOC-24VN PHOTOELECTRIC SMOKE DETECTOR
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, Hochiki America Model SOC-24VN photoelectric smoke
detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel. The
base shall permit direct interchange with Hochiki America SOC-24VN photoelectric smoke detector. The base shall be appropri-
ate twist-lock base NS-4 Series, NS-6 Series, HSC-4R, or HSC-R. In the event of partial or complete retrofit, the SOC-24VN
maybe used in conjunction with, or as a replacement for, Hochiki America detectors (SLR-24V, SLK-24 and the SLR-24H) on
most HSB and HSC base applications.
The smoke detector shall have one flashing status LED for visual supervision. When the detector is in standby condition the LED
will flash Green. When the detector is outside the UL listed sensitivity window the LED will flash Red. When the detector is
actuated, the flashing LED will latch on Red. The detector may be reset by actuating the control panel reset switch. The
sensitivity of the detector shall be capable of being measured. The sensitivity of the detector shall be monitored automatically and
continuously to verify that it is operating within the listed sensitivity range.
To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed
to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated.

SOC-24VN SENSITIVITY TEST FEATURE


The SOC-24VN Photoelectric Smoke Detector has a built-in automatic sensitivity test feature.
1. In normal condition, the status LED flashes green.
2. When the sensitivity drifts outside of its sensitivity limits, the status LED flashes red.
3. In the alarm state, the status LED is red continuously.
4. When the sensitivity drifts outside of its sensitivity limits and the LED flash red, the device needs to be cleaned or returned to
the factory for cleaning or calibration. Refer to HA Technical Bulletin HA-97 for cleaning information.

Hochiki America Corporation SOC-24VN PHOTOELECTRIC SMOKE DETECTOR Specifications subject to change without notice.