Table of Contents
1. REQUIREMENTS 4
Schlumberger Private
4. CMTSKIDLITE OPC SERVER SETTINGS 17
List of Figures
Schlumberger Private
Figure 9: Anybus X-gateway main menu................................................................................................................... 11
Figure 10: Change Configuration ................................................................................................................................ 12
Figure 11: Anybus IPconfig Setup Wizard................................................................................................................ 13
Figure 12: Select installation Folder for Anybus IPconfig ...................................................................................... 13
Figure 13: Confirm Installation of Anybus IPconfig ................................................................................................. 14
Figure 14: Complete Installation of Anybus IPconfig .............................................................................................. 14
Figure 15: Windows Security Alert............................................................................................................................. 15
Figure 16: Anybus IPconfig .......................................................................................................................................... 15
Figure 17: Ethernet Configuration ............................................................................................................................... 16
Figure 18: cmt_skid_lit.ini. ........................................................................................................................................... 17
Figure 19: XferCIPprofi Wix.msi .................................................................................................................................. 18
Figure 20: WinZip Caution ............................................................................................................................................ 18
Figure 21: Window Explorer - C:\Program Files\XferCIPprofi\data ....................................................................... 19
Figure 22: XferCIPprofi ................................................................................................................................................. 20
Figure 23: Network Configuration Sheet………………………………………………………………...23
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 4 of 22
1. Requirements
To successfully complete this procedure the following items will be required:
b) Ethernet Cable
c) Laptop
d) Screw Drivers
e) Configuration files, confi1.xml, XferCIPprofi Wix.zip and the HMS_1013.GSD (the GSD file
must be handle over the Rig to properly identify the Anybus via Profibus)
Schlumberger Private
f) External USB memory device.
2. Interface Network
PC ETHERNET CAN
(CMTSkidLite) DCU
CEG
IP 192.168.2.3 IP 192.168.2.2
ETHERNET
Profibus Slave
Add: 57
Profibus
Anybus
Network
Schlumberger Private
IP 192.168.2.16
Figure 1 shows the network interface from the CMTSkidLite to the Profibus network. By connecting an
Anybus gateway module between the CEG and the profibus network, information such as Slurry density,
Slurry volume, Slurry flow rate and Treating Pressure can be extracted from a cement pump (e.g CPS763)
to the client’s network.
The IP address of the PC must be set to 192.168.2.3. To check the IP address of the PC,
• Right-click the My Network Places icon on the desktop and go to Properties
• Right-click on the Local Area Connection that is connected using the Broadcom NetXtreme 57xx
Gigabit C and go to Properties
• Scroll down to Internet Protocol (TCP/IP) and click on it
• Click the Properties button and check the IP address
The configuration of the Anybus IP address will be illustrated in Section 3 (Software setup).
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 6 of 22
Schlumberger Private
Figure 2: Top Mounted Interface
1. Profibus Port
2. Node Address
4. Serial Port DB9
3. Connect the AnyBus Profibus cable directly to the OLM, bypassing the DP/DP coupler.
Schlumberger Private
Figure 4: Interface between the Profibus Port on the AnyBus and that on the OLM
Position 0 1 1 1 1 1 1 1 0
4. Software Setup
1. Connect the Laptop RS232 port to the RS232 port Gateway Configuration using the Null
modem cable.
Schlumberger Private
2. Follow the below mentioned steps on the Laptop
2.1.1 Start the Windows HyperTerminal (Start -> Programs -> Accessories ->
Communications -> HyperTerminal)
2.1.2 HyperTerminal will prompt for a name to use for the new connection.
Name the connection ‘AnyBus-X’, and click ok (Figure 6).
2.1.3 Specify which interface to use for the connection (select the COM port
that is connected to the gateway, in this particular case COM8), and click
‘OK’ (Figure 7).
Schlumberger Private
Figure 7: Com Port Selection
2.1.4 HyperTerminal will now prompt for the communication properties for the
interface. Ensure that the settings match that of the Gateway Config
Interface and click ‘Apply’ then ‘OK’ (Figure 8).
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 10 of 22
Schlumberger Private
Figure 8: Port Settings
Schlumberger Private
Figure 9: Anybus X-gateway main menu
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 12 of 22
Schlumberger Private
AnyBus IP Configuration
1. Install the Anybus Configuration tool (anybus ipconfig setup 1.3.1.1.msi) and click on “Next”.
Schlumberger Private
Figure 11: Anybus IPconfig Setup Wizard
Schlumberger Private
Figure 13: Confirm Installation of Anybus IPconfig
5. Go to the following path, “C:\Program Files\HMS\Anybus IPconfig” and double click on Anybus
IPconfig.exe
6. If Windows Security alerts pops up, click on the Unblock button.
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 15 of 22
Schlumberger Private
Figure 15: Windows Security Alert
7. Flip the IP Switch number 8 to ON position; it will assign the following IP to the Gateway
192.168.0.1, as is highlighted on the Network Installation Sheet (Page 22, figure 23).
8. Changed the IP address on CMTSkidLite PC to 192.168.0.2
9. Once the Software opens click on Scan to search the Anybus device as shown in Figure 16.
10. Double click on the IP address number to display the configuration settings.
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 16 of 22
11. Change the Ethernet Configuration Settings as showed below and click on the Set button.
Schlumberger Private
Figure 17: Ethernet Configuration
12. Reset the IP Switch number 8 to off position, it will enable the IP address previously set up on the
last step.
13. Change the PC CMTSkidLite IP address back to 192.168.2.3
14. Disconnect and Reconnect the power to the Anybus device to restart the device.
15. Re-open the AnyBus IPconfig software, scan for the Anybus interface and confirm that it sees the
Anybus Interface.
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 17 of 22
Schlumberger Private
Figure 18: cmt_skid_lit.ini.
4. Save changes
5. Open CMTSkidLite Software
Note: The CMTSkidLite version must be 1.2 build 15 or higher.
PDM # 100742751
Revision: AE
GUIDELINES Date: 22/03/10
Page: 18 of 22
If the XferCIPprofi software is not installed precede with the following steps otherwise go to step
number 4.
1. Double click on the XferCIPprofi Wix.zip file and subsequently on XferCIPprofi Wix.msi to
begin with the installation.
Schlumberger Private
Figure 19: XferCIPprofi Wix.msi
XferCIPprofi.lnk
Schlumberger Private
Figure 21: Window Explorer - C:\Program Files\XferCIPprofi\data