Professional Documents
Culture Documents
Guia Rapida Ion Fluor Aztec 600
Guia Rapida Ion Fluor Aztec 600
Introduction
In many parts of the world, fluoride is added to public water For this reason, the World Health Organization (WHO) has set
supplies to help improve dental health. Fluoride is found in an upper limit of 1.5mg/l for fluoride in drinking water.
all natural water to some degree. Surface waters generally
have low concentrations of fluoride, typically around 0.5mg/l. Given the potentially hazardous nature of the chemicals used
Groundwater may contain much higher levels of fluoride in fluoridation, and the potential consequences of over-
if it has been excessively exposed to inorganic minerals fluoridation, the addition of fluoride to drinking water must be
containing fluoride. accurately controlled and carefully monitored to ensure that
locally set operational criteria is adhered to.
Studies have shown that the addition of low concentrations
of fluoride of 1mg/l can assist in reducing the incidence of
tooth decay. However, the addition of fluoride to water is a
controversial subject, with doses above 1.5mg/l being linked
to medical disorders such as dental and skeletal fluorosis
and osteoporosis.
1
7
Mains Distribution
2
3
4 6
Isolation Valve
9
8
Drain Reagent In
The application
Different types of chemicals may be used in fluoridation To help maximise accuracy, the sampling point for any
processes, the most common being disodium hexafluorosilicate online monitoring instrument should be situated in a location
(Na2SiF6) and hexafluorosilicic acid (H 2SiF6), both of which pose where the sample is likely to have been sufficiently mixed.
a risk to human health and wildlife if not properly handled. Any sample must also be taken before the water is drawn
off to the distribution network.
The above diagram shows a typical water fluoridation treatment
plant arrangement. In this example, hexafluorosilicic acid is Given the potentially hazardous nature of the chemicals
held in a bulk storage tank (1) within a bunded area (2). Prior to used in fluoridation, and the potential consequences of
use, the acid is passed through an automatic dilution plant (3) over-fluoridation, water operators may also be required
to reduce its concentration and help simplify control of dosing. to demonstrate that they have been dosing within the
From here, the diluted acid is passed to a separate tank, which required limits.
holds around a day’s supply of acid. As a safeguard against
overdosing caused by potential plant failure, this tank is only Solution
topped up once in any 24 hour period. ABB’s Aztec 600 Fluoride analyzers provide accurate online
monitoring of fluoride dosing in potable water applications.
The dilute solution is pumped into the potable water supply by
a fluoride injection pump (5) on the outlet line from the tank. Incorporating a range of features, including high and low level
alarms, the Aztec 600 Fluoride offers reliable, and accurate,
The sample to the fluoride monitor (6) is taken after the main on-line analysis of fluoride concentrations, allowing immediate
supply pumps to ensure adequate mixing and to enable process decisions to be made to help preserve the safety of
a representative sample to be taken. The pump speed is the treatment process.
determined by the plant flow throughput and the pump stoke is
controlled by the output from the monitor. By utilising the same common platform as the Aztec
colorimetric range, the Aztec 600 Fluoride is able to
Challenge store data on the fluoride dosing process. This data can
Accurate dosing of the chemicals used to fluoridate the water be retrieved in a number of ways. A built-in Ethernet
can be further complicated by underlying levels of natural communications link with onboard web and ftp servers
fluoride in certain areas. In these areas, the dosing of chemicals enables remote monitoring, configuration selection, data and
to the water supply will need to be adjusted to take account of log file access to the analyzer from a web browser, whilst the
the existing background natural levels. option of Profibus DP allows access over a fieldbus network.
2 AD/ANAINST/012-EN | ABB Aztec 600 Fluoride Analyzers | Achieving safe fluoridation through online monitoring
How does it work?
Achieving safe fluoridation through online monitoring | ABB Aztec 600 Fluoride Analyzers | AD/ANAINST/012-EN 3
Contact us
AD/ANAINST/012-EN 05.2012
Oldends Lane We reserve the right to make technical
Stonehouse changes or modify the contents of this
Gloucestershire GL10 3TA document without prior notice. With
UK regard to purchase orders, the agreed
Tel: +44 (0)1453 826661 particulars shall prevail. ABB does not
Fax: +44 (0)1453 829671 accept any responsibility whatsoever
for potential errors or possible lack of
ABB Inc. information in this document.
Process Automation
125 E. County Line Road We reserve all rights in this document
Warminster and in the subject matter and
PA 18974 illustrations contained therein.
USA Any reproduction, disclosure to third
Tel: +1 215 674 6000 parties or utilization of its contents –
Fax: +1 215 674 7183 in whole or in parts – is forbidden
without prior written consent of ABB.
www.abb.com
Copyright© 2012 ABB
All rights reserved