Professional Documents
Culture Documents
Effective and hazard-free filtration and separation Metal oxides created during laser processes
can be separated safely and space-saving.
Applications
All metals and non-metals
Joining soldering, welding
Separation cutting, milling, grinding
Surface Treatment hardening, engraving, laminating
The Task The L-CUT series has been specially oxide particles. These units are com-
developed for the collection of dust pact and have a very low profile.
and fumes caused by thermal pro- Therefore, they can be installed in
cesses such as joining, separating, or tight spaces. The spark pre-separator
surface treatment by laser, plasma or KSE is already integrated in the hous-
gases, to separate the finest of metal ing.
Filter housing The housing is of welded design with evant components, i.e. disposal bin,
a variable dirty air inlet opening. The filter elements, motor-impeller sec-
integrated spark pre-separator pro- tion, solenoid valves, electrical
tects the filter elements against dam- switch and control system are acces-
age that could be caused by coarse, sible for servicing from the front.
potentially glowing particles. All rel-
Electrical Switch The cleaning intervals can be adjust- pressure measuring gauge or an ad-
and Control system ed individually for each type of appli- ditional cleaning can be programmed
cation by means of an integrated in the offline follow-up. Equipped
control. The fan’s volume flow almost with high-quality components accord-
remains constant. Optionally, the ing to VDE guidelines.
cleaning process can be released
either via an electronical differential
Electrical Switch
2
Technical data L-CUT
Functional description Dirty air flows through the dirty air The cleaned air flows through an in-
inlet (10) into the spark pre-separator termediate level (5) into the clean air
(11) where larger particles are sepa- chamber where it is pulled through
rated. The collected dust can be emp- the fan (6) and then exits through the
tied during operation by closing the silencer (13).
manual slide gate. The separated
dust is compressed in the disposal
container (8) by means of a dust com-
pression nozzle (18).
Air is deflected after the spark pre-
separator (11) which reduces speed
when the air contacts the filter ele-
ments (12). The dust particles settle
onto the surface of the filter ele-
ments, are cleaned off by compressed
air pulses and then fall into the two
disposal containers.
3
Separation technology dust collector L-CUT
References
02/2014
L-CUT 2 L-CUT 4
© Keller Lufttechnik - all rights reserved. Subject to modifications.