Relay Selection Criteria / FGR 31

Coil Information: 10. Are contacts making/breaking load current


1. a. Nominal Op. Voltage: ------- V (arcing?) Or, is load current passed to contacts
b. Pull-In Voltage: ------- V after making/breaking process is completed? ----
c. Drop-out Voltage ------- V -----------------------------------------------------------------
d. Min. Hold Voltage ------- V -----------------------------------------------------------------
e Max. Voltage ------- V 11. Response Time
a. Pull-In Time: ------- mSec
2. a. Operating Current: ------- mA b. Drop-out time: ------- mSec
b. Pull-In Current: ------- mA c. Bounce Time: ------- mSec
c. Max. Current ------- mA
12. QMS Test Procedure: --------------------------------
3. Coil Resistance: ------- Ohm -----------------------------------------------------------------
13. Contact Failure Rate: --------------------------------
4. Other Coil Operating Conditions: ------- -----------------------------------------------------------------
------------------------------------------------------------- 14. Expected Approvals (i.e. UL, CSA, TUV, etc.).
------------------------------------------------ Any other expected third party approval? ----------
-----------------------------------------------------------------
Contact Configuration:
5. Contact Form and Number: ------------------------ Ambient Operating conditions:
------------------------------------------------- 15. Ambient Temperature:
min. ------- oC; max. ------- oC;
6. Contact Ratings: 16. Vibration Resistance : ------- g
a. Voltage: min. ------- Vmax. ------ V (Amplitude): ------- Hz
b. Voltage: min. ------- mA max. ------ A 17. Shock Resistance : ------- g
c. Max. Power Capacity: ------- VA/W (Stroke): ------- mSec
d. Making/Breaking Capacity: ------- VA/W 18. Standards Considered for Vibration and Shock
e.Contact Resistance (new): ----- mOhm Tests: --------------------------------------------------------
-----------------------------------------------------------------
7. Load Characteristics: 19. Pass / Fail Conditions: ----------------------------------
a. DC / AC (50 / 60 Hz) -----------------------------------------------------------------
b. Resistive; Inductive; Capacitive --------------- 20. Application Description: --------------------------------
-------------------------------------------------- -----------------------------------------------------------------
c. Power Factor; Time Constant; Capacitive 21. Notes and Wiring Diagram:
Value ---------------------------------------------------
d. Load Wiring Diagram / Contact Circuit

8. Switching Frequency: ------ Cycles/Sec

9. Service Life with Indicated Load:


a. Electrical Inductance: ------ Cycles 1. Relay Type Designation – Part Number ------------
b. Mechanical Inductance: ------ Cycles -----------------------------------------------------------------
-----------------------------------------------------------------
-----------------------------------------------------------------