You are on page 1of 7
AEE 22651 UNIT 2 MCQ Practice Test Your score: 87% (29.5/34) Duration: 0:27:59 1. Lead acid battery, active material on positive plate is plate is Your Answer: v Correct % CAntimony, calcium ¥ GLead dioxide, sponge lead v [PbO2, Pb % OLead, sulphuric acid 2. Plate grid of maintenance free battery is made up of along with antimony. Your Answer: v Correct ¥ @Calcium, strontium OLead, lead peroxide 3. Battery case and cover Your Answer: ¥ Correct OProtects internal parts OPrevents electrolyte leakage ¥ @all the options are true Olas printed instructions/indications for handling and safety. Okeeps the internal parts in alignment 4, During charging, a conventional battery releases plates, and at the positive plates. Your Answer: ¥ Correct ¥ @Hydrogen, oxygen 35 Rushikesh Kale April 30, 2021, 4:58 p.m. and negative ?/2Pei's or 1/1 point 111 point at the negative —*/ * Point Oxygen, hydrogen 5. The plates of maintenance free battery never reaches fully charged"! P2! condition and therefore cause little or no release of hydrogen Your Answer: ¥ Correct v @Negative OPositive OBattery 6. Maintenance free battery 1512 pein Your Answer: v Partially correct ¥ Resists overcharging % Requires boost charging ¥ Does not tolerate deep cycling ¥ Gas about 20 percent higher cold cranking power. 7. Dry cell batteries 411 point Your Answer: v Correct Ohave no threat of leaking or spilled electrolyte. ¥ @Alloptions are correct are expensive but last longer than wet cell batteries OHave more power to crank engine in bad weather, 8. Dry cell batteries have a service life of 011 point Your Answer: X Incorrect Only five years. Y OThree to ten years % @Eiight to twelve years, OUpto three years. The material considered in Lithium ion batteries is 971 pot Your Answer: % Incorrect O Oxide of Cobalt! nickel or manganese at cathode. Otjydrogen containing carbon material at anode. % @A\l options are correct. ¥ OGraphite at anode 10. is essential for safe operation of Lithium ion 1/1 Pint battery. Your Answer: ¥ Correct ¥ @Battery management system OAdvanced materiral 11. Operating temperature range of lithium ion batteries is 011 point Your Answer: % Incorrect % ©20 to 60 degrees Y 0-20 to 60 degrees. 20 to 200 degrees 20 to 40 degrees. 12. rating is the length of time in minutes that a fully 144 point charged battery can discharged at 25 amperes before the battery voltage drops below 10.5 volts. Your Answer: v Correct v @Reserve capacity OWatt hour OCold cranking amperes O Twenty hour/Ampere-hours Batterv state of charae can be checked usina 111 point 13. Your Answer: ¥ Correct OSpecific gravity test Open circuit voltage test ¥ Specific gravity test and open circuit voltage test. 14. Battery drain test indicates an excessive battery drain if 111 point Your Answer: ¥ Correct OVoltmeter reads more than 0.5 volt. OVoltmeter reads less than 0.5 volts. ¥ @Ammeter reads more than 0.035 ampere. OAmmeter reads 0.020 ampere 15. Battery terminal test is a Voltage drop test to check for 111 point Your Answer: ¥ Correct ¥ ® poor electrical connections between the battery cable and the battery terminals. Othe battery's state of charge. 16. While disconnecting the battery cables, 111 point Your Answer: ¥ Correct ¥ @always disconnect the negative (ground) cable first. Oalways disconnect the positive cable first. 17. Alternator stator winding 111 point Your Answer: v Correct Ogenerates the magnetic lines of flux. ¥ @generates electricity by cutting the rotor magnetic flux. Oprovides a path of magnetic flux using laminated iron core. 18. Alternator testing is essential if 171 pat Your Answer: v Correct Obattery gets overcharged Obattery gets undercharged or not receiving any charge. Ocause of trouble is to be found out ¥ @AlIthe options are correct. 19. is carried out to find if there is current available to the 1! ‘point field winding. Your Answer: ¥ Correct ¥ @Field current draw test O Current output test ORegulator output test O Charging cirouit resistance test 20. Alternator uses voltage regulator to 1/1 point Your Answer: v Correct Oprevent generation of excessive voltage, thus avoiding damage to the electric units. Oprevent battery overcharging. Olimit maximum voltage in the electrical system. ¥ @all the options are correct. 24, Regulator output test is carried out with . 411 point Your Answer: ¥ Correct ¥ © Multimeter in Dc volt mode and select 0 to 20 V range. Multimeter with DC ammeter mode and select 50 A range. 22. Alternator Voltage regulators are calibrated to output between 111 point Your Answer: ¥ Correct ¥ ©13.5 to 15.5 V 23. 01210 13.5V O10 to 12V O8to12Vv Charge warming lamp 212painas Your Answer: ¥ Correct Owill glow if ignition is switched Owill go off, if alternator is driven above cut-in speed by operating engine. ¥ @all options are true. 24. Charging circuit resistance test is carried out to Owill continue to glow, even after the engine drives alternator above cut-in speed due to failed charging system. 111 point Your Answer: ¥ Correct ¥ @check the charging circuit- wires and connections for voltage drops 25. 26. Ocheck alternator voltage output. Odetermine maximum output of AC generator. . Alternator field winding 111 point Your Answer: v Correct ¥ @generates magnetic lines of flux. Ogenerates electricity by cutting the rotor magnetic flux. Ocools the rotor and stator. Oprovides a path of magnetic flux using laminated iron core. Current supplied to alternator rotor is called the 174 pot Your Answer: v Correct Y @field excitation current. output current. 27. Alternator regulator controls as per requirement. 11 point Your Answer: v Correct ¥ Voltage output of charging system OCurrent output of charging system 28. Alternator regulated is controlled by varying the ON and OFF time 2/2 Points of Your Answer: ¥ Correct OChoice 1 Ocurrent output, stator current ¥ @voltage output, field current 29. Computer regulation of alternator uses input 1/1 point Your Answer: ¥ Correct O Output voltage of alternator Battery temperature OBattery voltage ¥ @All the options are correct 30. Electronic voltage regulation of alternator circuit includes BFA pains Your Answer: % Incorrect Ofixed, variable and temperature dependant resistors OZener diode % ©Pair of transistors ¥ Oall the options are correct

You might also like