FINAL SITE PLAN/CONSTRUCTION PLAN


MASTER PERMIT TRACKING SCHEDULE

PERMIT # PERMITTING ENTITY CONTACT INFORMATION VICINITY MAP NTS


PLANNING AND DEVELOPMENT DEPARTMENT

FOR
PSP17-018
PCU#02-218.18 8731 CITIZENS DRIVE, SUITE 230
PASCO COUNTY PDP
ISSUE DATE: NEW PORT RICHEY, FL 34654
--/--/-- (941) 749-3070 LOCATION MAP
BLD-16-0443261
UTL-16-0000220
2014-D-194-49
PASCO COUNTY BUILDING PERMIT
PLANNING AND DEVELOPMENT DEPARTMENT
8731 CITIZENS DRIVE, SUITE 230
NEW PORT RICHEY, FL 34654
FOR
(941) 749-3070

APP NO: 737802 TAMPA SERVICE OFFICE


APP NO: 737808 SOUTHWEST FLORIDA WATER MANAGEMENT 7601 US HIGHWAY 301
ISSUE DATE: DISTRICT- ENVIRONMENTAL RESOURCE PERMIT TAMPA, FL 33637
--/--/-- (813) 985-7481
0168017-435- SOUTHWEST DISTRICT OFFICE
DSGP-DOH FLORIDA DEPARTMENT OF ENVIRONMENTAL 13051 N. TELECOM PARKWAY
ISSUE DATE: PROTECTION - WATER CONSTRUCTION TAMPA, FL 33602
--/--/-- (813) 407-5700
0168017-435- SOUTHWEST DISTRICT OFFICE
DSGP-DOH FLORIDA DEPARTMENT OF ENVIRONMENTAL 13051 N. TELECOM PARKWAY
ISSUE DATE: PROTECTION - DOMESTIC WASTEWATER TAMPA, FL 33602
--/--/-- (813) 407-5700
2017-A-798-51 FDOT TRAFFIC OPERATIONS
ISSUE DATE: FDOT STATE HIGHWAY ACCESS CONNECTION 11201 MCKINLEY DR,
--/--/-- TAMPA, FL 33612
(813) 975-4216
2017-D-798-39 FDOT TRAFFIC OPERATIONS
ISSUE DATE: FDOT STATE HIGHWAY DRAINAGE CONNECTION 11201 MCKINLEY DR,
--/--/-- TAMPA, FL 33612
(813) 975-4216

RACETRAC - BEXLEY
FOLIO No: 30-26-18-0010-00000-0010 NE
ER
S * CON
ST
R

UC
NG
C

T
C IV I L E

I ON I NSPEC
E
I

T
OR
RS

16671 STATE ROAD 54


S
NE
PLA N *

CAMPO
Anthon Digitally signed
by Anthony L.
ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

LAND O' LAKES, FL 34638


1725 EAST 5TH AVENUE

y L. Celani TAMPA, FL. 33605


PHONE: (813) 215-7372
Date: FAX: (813) 902-8782

RACETRAC PROJECT NO. 1220 Celani 2018.05.22


08:35:14 -04'00'

RACETRAC STORE NO. 2458 SHEET INDEX OF DRAWINGS


PLAN PLAN
SHEET NAME BY OTHERS REVISION
DATE DATE
C-0.0 COVER SHEET 11/04/15 1 06/07/16
UTILITY RESPONSIBILITY MATRIX FOR THIS PROJECT

CALL BEFORE YOU DIG # : 1(800) 432-4770 OR 811 SURVEY UTILITY CALL TICKET # :
PASCO COUNTY PCU#: 02-218.18 S-1
GN
BOUNDARY AND TOPOGRAPHIC SURVEY
GENERAL NOTES
11/04/15

11/04/15
1

1
06/07/16

06/07/16

ES-1 EROSION CONTROL PLAN AND DETAILS 11/04/15 1 06/07/16

D-1 DEMOLITION PLAN 11/04/15 1 06/07/16


x COORDINATE CONSTRUCTION ACTIVITIES WITH GAS x SERVICE FROM THE POINT OF CONNECTION AT THE EXISTING
TECO PEOPLES GAS
1400 CHANNELSIDE DRIVE
COMPANY TO ENSURE INSTALLATION OF GAS LINES ARE LINE UP TO AND INCLUDING SETTING OF THE METER C-1.1 SITE PLAN 11/04/15 1 08/02/16
GAS COMPLETED PRIOR TO CONCRETE OF CURB PLACEMENT [CEC TO STATE RESPONSIBLE PARTIES]
TAMPA, FL 33605
x INSTALL BOLLARD PROTECTION AS SHOWN ON THE PLANS x ANY RELOCATION OF EXISTING WILL BE DONE BY GAS C-1.2 PAVING PLAN 11/04/15 1 06/07/16
CONTACT: LUIS CASTELLANO
AND PER GAS COMPANY REQUIREMENTS COMPANY
PHONE: (813) 275 - 3743
[CEC TO STATE RESPONSIBLE PARTIES] HORIZONTAL CONTROL PLAN 11/04/15 1 08/02/16
C-1.3
GENERAL NOTES:
C-2.1 GRADING PLAN 11/04/15 1 06/07/16
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BECOME FAMILIAR WITH THE PERMIT AND INSPECTION REQUIREMENTS OF THE VARIOUS
x COORDINATE CONSTRUCTION ACTIVITIES WITH TELEPHONE x TELEPHONE COMPANY WILL PROVIDE AND INSTALL ALL 11/04/15 1 06/07/16
TELEPHONE CABLES FROM THE POINT OF CONNECTION UP
GOVERNMENTAL AGENCIES. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION, AND SCHEDULE C-2.2 DRAINAGE PLAN
COMPANY TO ENSURE INSTALLATION OF UNDERGROUND INSPECTION ACCORDING TO AGENCY INSTRUCTION.
FRONTIER COMMUNICATIONS TO THE BUILDING
NAME SEAL NO. DATE
LINES COMPLETED PRIOR TO CONCRETE OF CURB 11/04/15 1 06/07/16
7701 E. TELECOM PKWY
PLACEMENT [CEC TO STATE RESPONSIBLE PARTIES]
2. ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF THE VARIOUS GOVERNMENTAL AGENCIES HAVING C-2.3 PAVING GRADING AND DRAINAGE DETAILS
TEMPLE TERRACE, FL, 33637 JURISDICTION OVER THE WORK, INCLUDING LANDSCAPING.
x PROVIDE AND INSTALL 2-4" SCHEDULE 40 PVC CONDUITS x ANY RELOCATION OF EXISTING WILL BE DONE BY 3. CONTRACTOR SHALL SUBMIT FOR REVIEW TO THE OWNER'S CONSTRUCTION MANAGER SHOP DRAWINGS ON ALL PRECAST AND
TELEPHONE CONTACT: CARLOS BATES
WITH PULL ROPES, INCLUDING ALL TRENCHING AND TELEPHONE COMPANY C-2.4 CROSS SECTIONS 11/04/15 1 06/07/16
PHONE: (941) 906 - 6709 MANUFACTURED ITEMS TO USE ON THIS SITE. FAILURE TO OBTAIN APPROVAL BEFORE INSTALLATION MAY RESULT IN REMOVAL AND
BACKFILLING FROM RISER POLE UP TO THE BUILDING. [CEC TO STATE RESPONSIBLE PARTIES] REPLACEMENT AT CONTRACTOR'S EXPENSE. CONSTRUCTION MANAGER'S APPROVAL OF A SHOP DRAWING DOES NOT RELIEVE
x PROVIDE AND INSTALL PULL BOXES AS PER TELEPHONE C-2.5 PROFILES 11/04/15 1 06/07/16
CONTRACTOR'S RESPONSIBILITY FOR PERFORMANCE OF THE ITEM.
COMPANY REQUIREMENTS. 4. WORK PERFORMED UNDER THIS CONTRACT SHALL INTERFACE SMOOTHLY WITH OTHER WORK BEING PERFORMED ON SITE BY OTHER
C-3.1 UTILITY PLAN 11/04/15 1 07/11/16
CONTRACTORS AND UTILITY COMPANIES. IT IS NECESSARY FOR THE CONTRACTOR TO COORDINATE AND SCHEDULE HIS ACTIVITIES, WHERE
NECESSARY WITH OTHER CONTRACTOR'S AND UTILITY COMPANIES.
5. MATERIALS AND CONSTRUCTION METHODS FOR STREETS AND STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE C-3.2 UTILITY DETAILS (1) 11/04/15 1 02/19/16
x COORDINATE CONSTRUCTION ACTIVITIES WITH ELECTRIC x ELECTRIC COMPANY WILL PROVIDE AND INSTALL ALL LOCAL REGULATORY AGENCY.
MATERIALS NEEDED TO ESTABLISH PRIMARY OVERHEAD 6. CONTRACTOR SHALL REVIEW SOIL REPORTS AND BORINGS PRIOR TO BIDDING THE PROJECT AND COMMENCING CONSTRUCTION. C-3.3 UTILITY DETAILS (2) 11/04/15 1 02/19/16
COMPANY TO ENSURE INSTALLATION OF UNDERGROUND
LINES COMPLETED PRIOR TO CONCRETE OF CURB SERVICE FROM POINT OF CONNECTION AT THE EXISTING 7. AT LEAST 72 HOURS PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND APPROPRIATE AGENCIES AND SUPPLY
PLACEMENT LINE UP TO THE TRANSFORMER [CEC TO STATE THEM WITH ALL REQUIRED SHOP DRAWINGS, THE CONTRACTOR'S NAME, STARTING DATE, PROJECTED SCHEDULE, AND OTHER INFORMATION C-3.4 PUMP STATION DETAILS 11/04/15 1 02/19/16
DUKE ENERGY - ST PETERSBERG x PROVIDE AND INSTALL 2-4" SCHEDULE 40 PVC CONDUITS RESPONSIBLE PARTIES] AS REQUIRED. ANY WORK PERFORMED PRIOR TO NOTIFYING THE ENGINEER OR WITHOUT AGENCY INSPECTOR PRESENT MAY BE SUBJECT
1601 WEEDON ISLAND DR. WITH PULL ROPES, INCLUDING ALL TRENCHING AND x ELECTRIC COMPANY WILL PROVIDE AND INSTALL PRIMARY TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. SP-1 SITE PHOTOMETRY PLAN (BY OTHERS)
ELECTRIC ST. PETERSBURG, FL 33702 CABLE FOR ALL UNDERGROUND LINES UP TO THE 8. THE CONTRACTOR SHALL USE EACH PLAN IN CONJUNCTION WITH THE ENTIRE SET OF DRAWINGS AND JOB SPECIFICATIONS. DO NOT REMOVE
BACKFILLING FROM RISER POLE UP TO THE TRANSFORMER.
CONTACT: MEISHA BARNARD SCHEDULE 80 PVC CONDUITS SHALL BE USED ON THE RISER TRANSFORMER OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING WITH ALL ELECTRICAL, PLUMBING, MECHANICAL, GENERAL TRADES, AND L-1.1 LANDSCAPE PLAN (INCLUDED BY RACETRAC)
PHONE: (352) 694 - 8521 POLE AND RIGID METAL, LONG RADIUS, ELBOWS SHALL BE [CEC TO STATE RESPONSIBLE PARTIES] UTILITY COMPANIES AS THEY EFFECT THE OVERALL PROJECT.
USED WHERE THE UNDERGROUND PORTION MEETS THE x ANY RELOCATION OF EXISTING WILL BE DONE BY ELECTRIC 9. ALL WORK SHOWN SHALL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS L-1.2 LANDSCAPE DETAILS (INCLUDED BY RACETRAC)
RISER POLE AND TRANSFORMER. COMPANY
x CONSTRUCT TRANSFORMER PAD AS PER THE ELECTRIC [CEC TO STATE RESPONSIBLE PARTIES] L-1.3 LANDSCAPE SPECIFICATIONS (INCLUDED BY RACETRAC)
COMPANY'S SPECIFICATIONS
x PROVIDE AND INSTALL ALL SECONDARY SERVICE AND SURVEYOR L-2.1 IRRIGATION PLAN (INCLUDED BY RACETRAC)
MATERIALS.
GEOPOINT SURVEYING, INC. L-2.2 IRRIGATION DETAILS (INCLUDED BY RACETRAC)
JOHN D. WEIGLE
x PROVIDE AND INSTALL SANITARY SEWER LINE AND
PROFESSIONAL LAND SURVEYOR AND MAPPER
1403 E. 5TH AVENUE
ENGINEER L-2.3
SD1
IRRIGATION SPECIFICATIONS (INCLUDED BY RACETRAC)
STANDARD DETAILS RACETRAC 11/04/15 1 06/07/16
ASSOCIATED APPURTENANCES PER THE PLANS AND
PASCO COUNTY UTILITIES
SPECIFICATIONS. TAMPA, FL 33605 CAMPO ENGINEERING INC. STANDARD DETAILS RACETRAC 11/04/15 1 06/07/16
PUBLIC WORKS/ UTILITY BUILDING SD2
7356 STATE STREET, SUITE 118
x ALL PUBLIC AND PRIVATE SANITARY SEWER LINES SHALL BE
PVC AND RATED SDR 26
PHONE: (813) 248 - 8888 PROJECT MANAGER
SANITARY NEW PORT RICHEY, FL 34654 ANTHONY CELANI PE SD3 STANDARD DETAILS RACETRAC 11/04/15 1 06/07/16
SEWER CONTACT: CHARLES J. CULLEN,
x COORDINATE REQUIRED INSPECTION SERVICES WITH FAX: (813) 248 - 2266
PHONE: (813) 274-7096
ENGINEER OF RECORD AND CITY OF ANYTOWN DEPARTMENT 1725 E 5TH AVE SD4 STANDARD DETAILS RACETRAC 11/04/15 1 06/07/16
OF PUBLIC WORKS. SEE UTILITY PLAN FOR REQUIREMENTS.
ARCHITECT TAMPA, FL 33605
PHONE: (813) 215 - 7372 TS1 OFFSITE PLAN 11/04/15 1 06/07/16
HILL FOLEY ROSSI & ASSOCIATES OFFSITE PLAN 11/04/15 1 06/07/16
x PROVIDE AND INSTALL ALL WATER MAINS AND ASSOCIATED x DOMESTIC TAP FORM THE POINT OF CONNECTION AT THE FAX: (813) 470 - 0872 TS2
APPURTENANCES PER THE PLANS AND SPECIFICATIONS. EXISTING LINE UP TO AND INCLUDING SETTING OF THE JEFFREY T. HILL, RA
PASCO COUNTY UTILITIES TS3 OFFSITE PLAN 11/04/15 1 06/07/16
PUBLIC WORKS/ UTILITY BUILDING
x ALL PUBLIC AND PRIVATE SANITARY SEWER LINES SHALL BE METER AT THE PROPERTY LINE WILL BE BY THE WATER PRINCIPAL, LANDSCAPE ARCHITECT
C-900 PVC, DR14 CLASS 200 COMPANY.
7356 STATE STREET, SUITE 118
x ALL PORTIONS OF THE FIRE PROTECTION WATER SYSTEM [CEC TO STATE RESPONSIBLE PARTIES] 3680 PLEASANT HILL ROAD, SUITE 200
OWNER/DEVELOPER
WATER NEW PORT RICHEY, FL 34654
CONTACT: CHARLES J. CULLEN,
SHALL BE INSTALLED BY A LICENSED FIRE SPRINKLER
CONTRACTOR
x ANY RELOCATION OF EXISTING WILL BE DONE BY PASCO
COUNTY PUBLIC WORKS
DULUTH, GA 30096
PHONE: (813) 274-7096
x ALL PORTIONS OF OTHER NON FIRE PROTECTION RELATED [CEC TO STATE RESPONSIBLE PARTIES] PHONE: (770) 622 - 9858
LINES MAY BE INSTALLED BY THE PLUMBING CONTRACTOR
x COORDINATE REQUIRED INSPECTION SERVICES WITH FAX: (770) 622 - 9535 RACETRAC PETROLEUM, INC.
ENGINEER OF RECORD AND CITY OF ANYTOWN DEPARTMENT 3225 CUMBERLAND BOULEVARD
OF PUBLIC WORKS. SEE UTILITY PLAN FOR REQUIREMENTS.
LANDSCAPE ARCHITECT SUITE 100 ATLANTA, GA 30339
ENGINEERING PROJECT MANAGER: JON JANSSEN
HARDEMAN-KEMPTON & ASSOCIATES, INC.
JASON RINARD, RLA (770) 431-7600 EXT 1730
x PROVIDE AND INSTALL STORM SEWER LINES AND PRINCIPAL, LANDSCAPE ARCHITECT CONSTRUCTION PROJECT MANAGER: JIMMY HARPE
PASCO COUNTY UTILITIES
PUBLIC WORKS/ UTILITY BUILDING
ASSOCIATED APPURTENANCES PER THE PLANS AND 2207 WEST NORTH A STREET (770) 431-7600 EXT 1755
SPECIFICATIONS.
STORM
TAMPA, FL 33606 24 HR CONTACT: (770) 431-7600 EXT 1755
R
7356 STATE STREET, SUITE 118 x REFER TO GRADING PLAN FOR INFORMATION ON ALLOWABLE
SEWER NEW PORT RICHEY, FL 34654
CONTACT: CHARLES J. CULLEN,
STORM SEWER MATERIALS.
PHONE: (813) 258 - 0066
PHONE: (813) 274-7096
FAX: (813) 258 - 1783
THIS MATRIX HAS BEEN PROVIDED FOR INFORMATIONAL PURPOSES. THE CONTRACTOR SHALL PROVIDE ANY AND ALL GOVERNING STANDARDS AND SPECIFICATIONS:
APPURTANCES, TRENCHING AND BACKFILL, AND OTHER INCIDENTALS TO MEET OR EXCEED THE SPECIFICATIONS OF THE ITEMS LISTED. CONTACT RACETRAC PETROLEUM, INC. PROJECT MANAGER PRIOR TO ANY REVISIONS FLORIDA DEPARTMENT OF TRANSPORTATION, 2015 DESIGN STANDARDS AND REVISED INDEX DRAWINGS AS APPENDED HEREIN,

TO THE PLAN SUPPLIED BY RACETRAC PETROLEUM, INC. AND 2015 STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, AS AMENDED BY CONTRACT DOCUMENTS.
DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

LEGEND

S * CON
ER ST
NE R

UC
NG
C

T
C IV I L E

I ON I NS PEC
E
I

T
OR
RS S
NE
PLA N *

CAMPO
ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

1725 EAST 5TH AVENUE


TAMPA, FL. 33605
PHONE: (813) 215-7372
FAX: (813) 902-8782

NAME SEAL NO. DATE

Location of reading
OU

Spot Elevation

Surveyor's Notes: parties is prohibited without the written consent of the signing party or parties. Legal Description: (See Surveyors Notes No.1)
SURVEYOR BENCHMARK NOTES
1) GeoPoint Surveying is in receipt of Chicago Title Insurance Company Commitment for 7) The subject property lies in Flood Zone "X", "A" and "AE" (base flood elevation = 51.7
Fee Parcel:
Title Insurance, Counter signed by, Feldman & Mahoney, P.A., Order No.: 5789939, feet), according to Flood Insurance Rate Map, Map No. 12101C0383F, for Pasco County, NOTE: Trees by nature are irregular in size and shape. Every effort is
Lot 1, SUNCOAST COMMERCIAL CENTER, according to the map or plat thereof, recorded in Plat Book 71, 1. BENCHMARK DESCRIPTION Elevation (feet)
Customer Reference: Bexley/RaceTrac, Effective Date: May 11, 2016. Florida, dated September 26, 2014, and issued by the Federal Emergency Management made to accurately locate trees. The tree size is determined at dia-
Pages 144 through 147, inclusive, of the Public Records of Pasco County, Florida, being more particularly Set Nail and Disk #7768 in curb inlet on the South side (NAVD 88) Elevation = 54.18
(Exhibit “A”, legal description contained therein has been amended per client request.) Agency. Lines shown have been digitally translated from DFIRM database information meter breast height. The tree location is the center of the tree. This
described as follows: of Lot 4, North side of Street B. (NGVD 29) Elevation = 55.01
supplied by the FEMA Map Service Center https://msc.fema.gov). location may be different if located from a different direction. All tree
Stamped “TBM #21”
2) This survey is limited to above ground visible improvements along and near the locations should be field checked if critical to design.
8) On this drawing, certify means to state or declare a professional opinion of conditions Begin at the Southwest corner of said Lot 1 thence N.24°47'38"W., 235.95 feet along the Westlery
boundary lines, except as shown hereon, and that nothing below the ground was located
including, but not limited to foundations (footings), utilities, etc. regarding those findings or facts which are the subject of the certification and does not boundary of said Lot 1 said boundary also being the Easterly Right-of-Way of Bexley Village Drive,
BENCHMARK DESCRIPTION Elevation (feet)
constitute a warranty or guarantee, either implied or expressed. This certification is only thence leaving said Easterly Right-of-way N.65°13'37"E., 70.00 feet; thence N.55°00'05"E., 54.34 feet;
Set Nail and Disk #7768 in curb inlet on the East side (NAVD 88) Elevation = 53.59
3) The bearings shown hereon are based on Record Plat, more specifically the North for the lands as described. This certification is not a certificate of title, easements, zoning thence N.65°13'37"E., 325.30 feet to a point on the Easterly boundary of said Lot 1, thence along said of Bexley Blvd 245' Northeast of the P.I. of Street C & Bexley Blvd. (NGVD 29)
boundary of the Southeast 1/4 of Section 30, Township 26 South, Range 18 East, Pasco or freedom of encumbrances. Easterly boundary the following 5 (five) courses and distances: 1) S.08°52'58"E., 25.47 feet; thence 2) Elevation = 54.42
County, Florida, having a grid bearing of S.89°22'55"E. The grid bearings as shown hereon S.19°59'11"E., 97.08 feet; thence 3) S.12°24'33"E., 56.79 feet; thence 4) S.00°31'59"W., 67.21 feet; Stamped “TBM #23” 18 P
refer to the State Plane Coordinate System (NAD 83-1990 ADJUSTMENT) for the West
Zone of Florida.
DATUM NOTE thence 5) S.26°37'28"E., 8.12 feet to the Southerly boundary of said Lot 1, said boundary also being the
Northerly Right-of-Way of said State Road 54, thence along said Right-of-Way S.65°13'37"W., a distance FIELD DATA:
DATUM CONVERSION of 392.99 feet to the Point of Beginning. PNT#4091,1402940.199367,481838.124821,54.167116,TBM #21 54.18 CK
4) This survey is intended to be displayed at 1" = 30'. PNT#4092,1403606.544621,482102.661179,53.603698,TBM #23 53.59 CK R
0.00' NAVD88 = 0.83 NGVD29
(ALL GRADES SHOWN ARE IN NAVD88
Together with perpetual non-exclusive easement(s) for the benefit of the above described fee parcel, as
5) All boundary line dimensions are Plat (P) or field measured (S) unless otherwise noted.
DATUM) set forth in that certain Charter for Bexley Commercial Properties recorded in Official Records Book
ORIGINATING BENCHMARK: Elevations listed above are based on National Dia
6) Additions or Deletions to survey maps or reports by other than the signing party or 9274, Page 1284, of the Public Records of Pasco County, Florida; and Geodetic Survey (NGS) Survey Control Monument, designated as “B 669”. Having an

DBH
elevation of 53.80 North American Vertical Datum of 1988 (NAVD 88). A conversion
Together with perpetual, non-exclusive easement(s) for the benefit of the above described fee parcel, as factor of +0.83' was utilized to obtain NGVD 29 elevations.
set forth on the Plat of Suncoast Commercial Center recorded in Plat Book 71, Pages 144 through 147,
inclusive, of the Public Records of Pasco County, Florida.
DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

GENERAL NOTES SANITARY SEWER WATER DISTRIBUTION GENERAL LANDSCAPE NOTES:


CONSTRUCTION NOTES
SAFETY

PIPE SEPARATION REQUIREMENTS:

S * CON
ER ST
NE R

UC
NG
C

T
C IV I L E

I ON I NSPEC
E
I

T
OR
RS S
NE
P LAN *

CAMPO
ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

1725 EAST 5TH AVENUE


TAMPA, FL. 33605
PHONE: (813) 215-7372
FAX: (813) 902-8782
PAVING AND GRADING
EXISTING TREE PROTECTION NOTES: CONTRACTOR PERMIT LIST
1. CONTRACTOR TO PULL ALL RIGHT OF WAY USE PERMITS. CONTRACTOR IS RESPONSIBLE
FOR MOT PLANS TO BE PROVIDED TOTHE FDOT AND PASCO COUNTY.

2. CONTRACTOR TO SCHEDULE PASCO COUNTY PRE-CON MEETING AND NOTIFY ENGINEER.

3. CONTRACTOR TO OBTAIN ANY SITE PIPING PERMITS.

4. CONTRACTOR TO OBTAIN TREE REMOVAL / CLEARING PERMIT FOR PASCO COUNTY.

5. CONTRACTOR MUST HAVE MOT CERTIFIED FIELD PERSONNEL.

6. A BOND OR LETTER OF CREDIT MAY BE REQUIRED.

7. INSURANCE CERTIFICATE IS REQUIRED TO WORK IN ROW. CONTRACTOR'S LIABILITY


INSURANCE (SEE FAC 14-96.007(5)(C)(6) AND 48 HOUR START CONSTRUCTION NOTIFICATION
IS REQUIRED BEFORE CONSTRUCTION STARTS. NO CONSTRUCTION OR OTHER ACCESS TO
THIS PROJECT VIA THE FDOT ROW IS ALLOWED UNTIL A PERMIT IS ISSUED (PLEASE PRINT
THE FDOT PERMIT NUMBER ON THE LIABILITY INSURANCE).

CLEARING/DEMOLITION 8. A LICENSE IS REQUIRED FOR UNDERGROUND UTILITIES INSTALLATIONS.

NAME SEAL NO. DATE

ITEM TEST TEST FREQUENCY

EMBANKMENT OPTIMUM MOISTURE/MAXIMUM DENSITY PER SOIL TYPE


95% OF MODIFIED PROCTOR (AASHTO T-180-57, ASTM D-1557) ONE PER 500 FEET
HORIZONTALLY, IN 12 INCH LIFTS
UTILITY TRENCH BACKFILL OPTIMUM MOISTURE/MAXIMUM DENSITY PER SOIL TYPE
OVER PIPELINES AND AROUND 98% OF MAXIMUM DENSITY AS DETERMINED BY AASHTO T180-57 (ASTM *,**,****
STRUCTURES FROM R.O.W. D1557-70) - MINUS 3% TOLERANCE
LINE TO R.O.W. LINE
UTILITY TRENCH BACKFILL OPTIMUM MOISTURE/MAXIMUM DENSITY PER SOIL TYPE
OVER PIPELINES AND AROUND 98% OF MAXIMUM DENSITY AS *,**,****

SITE PLAN AND COORDINATE GEOMETRY PASCO COUNTY SINK HOLE NOTES STRUCTURES OUTSIDE
THE R.O.W.
DETERMINED BY AASHTO T180-57 (ASTM D1557-70) - MINUS 3% TOLERANCE

STABILIZED SUBGRADE OPTIMUM MOISTURE/MAXIMUM DENSITY PER MATERIAL TYPE

MINIMUM 40 LBR *** PER MATERIAL TYPE

98% OF MAXIMUM DENSITY AS DETERMINED BY AASHTO T180-57 (ASTM ***


D1557-70) - NO TOLERANCE

BASE OPTIMUM MOISTURE/MAXIMUM DENSITY PER SOURCE


(OTHER THAN SOIL CEMENT)
MINIMUM 100 LBR PER SOURCE

98% OF MAXIMUM DENSITY AS DETERMINED BY AASHTO T180-57 (ASTM *** EACH LIFT
DRAINAGE D1557-70) - NO TOLERANCE

GRADATION, ATTERBURG LIMITS PER SOURCE


CONCRETE SLUMP TEST ONE PER SET OF CYLINDERS
COMPRESSIVE STRENGTH CYLINDERS ONE SET OF THREE (3) CYLINDERS FOR
100 CUBIC YARDS OR FRACTION THEREOF

AIR CONTENT ONE PER SET OF CYLINDERS

ASPHALTIC CONCRETE AGGREGATE ANALYSIS ONE PER DESIGN


DESIGN MIX ONE PER TYPE
BITUMEN CONTENT ONE PER DAY

GRADATION STABILITY FLOW ONE PER DAY

PROPERTIES OF IN PLACE MATERIALS (MARSHALL) ONE PER DAY


THICKNESS ***

95% OF LAB DENSITY ***


DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

LEGEND

EC EC

TB TB

EROSION CONTROL NOTES:


1. CONTRACTOR SHALL MAINTAIN EROSION CONTROL FACILITIES DURING THE ENTIRE
CONSTRUCTION PERIOD. FACILITIES ARE NOT TO BE REMOVED UNTIL COMPLETION OF THE
PROJECT AND THE SITE IS STABILIZED.
2. ADDITIONAL DEVICES MAY BE REQUIRED AS DEEMED NECESSARY BY GOVERNING
AUTHORITIES.
3. SILT FENCES SHALL BE CLEANED OR REPLACED WHEN TRAPPED SEDIMENT REACHES 50
PERCENT OF THE ABOVE GROUND FENCE HEIGHT OR A LOWER HEIGHT BASED ON
MANUFACTURER'S SPECIFICATIONS.
4. SEDIMENT AND EROSION CONTROL MEASURES WILL BE INSPECTED ON A DAILY BASIS AND
REPAIRED, ADJUSTED AND MAINTAINED AS NEEDED OR REQUIRED BY GOVERNING AGENCIES
AT NO ADDITIONAL EXPENSE TO THE OWNER TO PROVIDE EROSION AND SEDIMENT CONTROL
FOR THE DURATION OF CONSTRUCTION AND UNTIL ALL DISTURBED AREAS ARE STABILIZED.
5. ALL GRADED AREAS SHALL BE STABILIZED WITH A PERMANENT FAST GROWING COVER
AND/OR MULCH UPON COMPLETION OF GRADING OPERATIONS. COMPLETION OF GRADING
OPERATIONS DOES NOT MEAN AT THE END OF THE PROJECT. AS SOON AS FINAL GRADES ARE
ESTABLISHED IN AN UNPAVED AREA, THE CONTRACTOR SHALL STABILIZE WITH A TEMPORARY
GRASS OR PERMANENT SOD. IF A TEMPORARY GRASS IS APPLIED, IT WILL BE THE
CONTRACTOR'S RESPONSIBILITY TO APPLY A PERMANENT SEED OR SOD AT THE PROPER TIME
OF YEAR.
6. FILL SLOPES SHOULD BE PLANTED AS SOON AS AN AREA OF THE SITE IS BROUGHT TO FINAL
GRADE. SURFACE RUNOFF SHALL BE INTERCEPTED AT THE TOP OF TEMPORARY AND
PERMANENT SLOPES DURING CONSTRUCTION SO THAT WATER IS NOT ALLOWED TO FLOW
OVER THE SLOPE FACE.
7. THE GENERAL CONTRACTOR AND THE GRADING CONTRACTOR SHALL REVIEW THEIR
PROPOSED GRADING SEQUENCE TO INSURE THAT THE LEAST AMOUNT OF LAND POSSIBLE AT
ANY ONE TIME IS DISTURBED WITHOUT PERMANENT STABILIZATION.
8. CONTRACTOR SHALL INSTALL TEMPORARY CONSTRUCTION ENTRANCES PRIOR TO ANY
EARTHWORK OPERATIONS.
9. CONTRACTOR SHALL MAINTAIN SILT FENCES FOR THE DURATION OF THE PROJECT UNTIL * CON
S
ER ST
ACCEPTED BY THE OWNER AT NO EXPENSE TO OWNER. NE R

UC
NG
10. LAND DISTURBING ACTIVITIES BE KEPT TO A MINIMUM AND WILL NOT EXTEND BEYOND THE
C

T
C IV I L E

I ON I NSPEC
LIMITS SHOWN.
11. THE CONTRACTOR SHALL CONSTRUCT THE SILT FENCING AS SHOWN AT THE PERIMETER OF
E
I

*
THE SITE PLAN PRIOR TO LAND CLEARING ACTIVITIES.

T
OR
RS S
12. CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE COMPLIANCE WITH THE NPDES P LAN
NE *

STORMWATER REQUIREMENTS. THIS INCLUDES, BUT IS NOT LIMITED TO, INSPECTION

CAMPO
REQUIREMENTS.
13. ALL EROSION CONTROL MEASURES EXCEPT THE REQUIRED RIP RAP ARE TEMPORARY
DEVICES. THESE TEMPORARY DEVICES SHALL BE REMOVED PRIOR TO COMPLETION OF ENGINEERING, INC.
CONSTRUCTION ONCE STABILIZATION OF ALL GRASSED AREAS ARE COMPLETE. FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726
14. PRIOR TO CONSTRUCTION, THE EROSION AND SEDIMENT CONTROL MEASURES SHOWN
HEREON SHALL BE IN PLACE. CLEARING AND GRUBBING OPERATIONS WILL BE ENGAGED IN 1725 EAST 5TH AVENUE
ONLY AS NECESSARY TO ALLOW THE PLACEMENT OF EROSION AND SEDIMENT CONTROL TAMPA, FL. 33605
MEASURES AS SHOWN HEREON UNTIL ALL SUCH MEASURES ARE IN PLACE. PHONE: (813) 215-7372
15. CONTRACTOR IS RESPONSIBLE FOR REPAIRS OR DAMAGE TO ANY EXISTING IMPROVEMENTS FAX: (813) 902-8782
DURING CONSTRUCTION, SUCH AS, BUT NOT LIMITED TO, DRAINAGE, UTILITIES, PAVEMENT,
STRIPING, CURB, ETC., REPAIRS SHALL BE EQUAL TO OR BETTER THAN EXISTING CONDITIONS.

EROSION CONTROL SPECIFICATIONS


1. THE INSTALLATION OF TEMPORARY EROSION CONTROL BARRIERS SHALL BE
COORDINATED WITH THE CONSTRUCTION OF THE PERMANENT EROSION CONTROL
FEATURES TO THE EXTENT NECESSARY TO ASSURE ECONOMICAL, EFFECTIVE AND
CONTINUOUS CONTROL OF EROSION AND WATER POLLUTION THROUGHOUT THE
LIFE OF THE CONSTRUCTION PHASE.

2. THE TYPE OF EROSION CONTROL BARRIERS USED SHALL BE GOVERNED BY THE


NATURE OF THE CONSTRUCTION OPERATION AND SOIL TYPE THAT WILL BE
EXPOSED. SILTY AND CLAYEY MATERIAL USUALLY REQUIRE SOLID SEDIMENT
BARRIERS TO PREVENT TURBID WATER DISCHARGE, WHILE SANDY MATERIAL MAY
NEED ONLY SILT SCREENS OR HAY BALES TO PREVENT EROSION. FLOATING
TURBIDITY CURTAINS SHALL BE USED IN OPEN WATER SITUATIONS. DIVERSION
DITCHES OR SWALES MAY BE REQUIRED TO PREVENT TURBID STORMWATER
RUNOFF FROM BEING DISCHARGED TO WETLANDS OR OTHER WATER BODIES. IT
MAY BE NECESSARY TO EMPLOY A COMBINATION OF BARRIERS, DITCHES AND
OTHER EROSION/TURBIDITY CONTROL MEASURES IF CONDITIONS WARRANT.

3. CONSTRUCTION OPERATIONS IN OR ADJACENT TO WETLANDS SHALL BE


RESTRICTED TO THOSE AREAS IDENTIFIED IN THE PLANS AND IN THE
SPECIFICATIONS.

4. EXCAVATED MATERIAL SHALL NOT BE DEPOSITED IN THE WETLANDS OR IN A


POSITION CLOSE ENOUGH THERETO TO BE WASHED AWAY BY HIGH WATER OR NAME SEAL NO. DATE

RUNOFF.

5. WHERE PUMPS ARE TO BE USED TO REMOVE TURBID WATERS FROM


CONSTRUCTION AREAS, THE WATER SHALL BE TREATED PRIOR TO DISCHARGE TO
THE WETLANDS. TREATMENT METHODS INCLUDE AND ARE NOT LIMITED TO, TURBID
WATER BEING PUMPED INTO GRASSED SWALES OR APPROPRIATE VEGETATED
AREAS, SEDIMENT BASINS, OR CONFINED BY AN APPROPRIATE ENCLOSURE SUCH
AS TURBIDITY BARRIERS, AND KEPT CONFINED UNTIL ITS TURBIDITY LEVEL MEETS
STATE WATER QUALITY STANDARDS.

6. THE CONTRACTOR SHALL SCHEDULE HIS OPERATIONS SUCH THAT THE AREA OF
UNPROTECTED ERODIBLE EARTH EXPOSED AT ANY ONE TIME IS NOT LARGER THAN
THE MINIMUM AREA NECESSARY FOR EFFICIENT CONSTRUCTION OPERATIONS, AND
THE DURATION OF EXPOSED, UNCOMPLETED CONSTRUCTION TO THE ELEMENTS
SHALL BE AS SHORT AS PRACTICABLE. CLEARING AND GRUBBING SHALL BE SO
SCHEDULED AND 3PERFORMED THAT GRADING OPERATIONS CAN FOLLOW
IMMEDIATELY THEREAFTER, AND GRADING OPERATIONS SHALL BE SCHEDULED
AND PERFORMED THAT PERMANENT EROSION CONTROL FEATURES CAN FOLLOW
IMMEDIATELY THEREAFTER IF CONDITIONS ON THE PROJECT PERMIT.

7. THE CONTRACTOR AND/OR OWNER'S REPRESENTATIVE SHALL PROVIDE ROUTINE


MAINTENANCE OF PERMANENT AND TEMPORARY EROSION CONTROL FEATURES
UNTIL THE PROJECT IS COMPLETE AND ALL BARED SOILS ARE STABILIZED.

8. SILT FENCE SHALL BE LOCATED AT THE PERIMETER OF CONSTRUCTION LIMITS, AS


DEFINED BY FIELD CONDITIONS.

9. CONTRACTOR IS TO PROVIDE EROSION CONTROL AND SEDIMENTATION BARRIER


(HAY BALES OR SILTATION CURTAIN) TO PREVENT SILTATION OF ADJACENT
PROPERTY, STREETS, STORM SEWERS AND WATERWAYS. IN ADDITION,
CONTRACTOR SHALL PLACE STRAW, MULCH OR OTHER SUITABLE MATERIAL ON
GROUND IN AREAS WHERE CONSTRUCTION RELATED TRAFFIC IS TO ENTER AND
EXIT SITE. IF, IN THE OPINION OF THE ENGINEER AND/OR LOCAL AUTHORITIES,
EXCESSIVE QUANTITIES OF EARTH ARE TRANSPORTED OFF-SITE EITHER BY
NATURAL DRAINAGE OR BY VEHICULAR TRAFFIC, THE CONTRACTOR IS TO REMOVE
SAID EARTH TO THE SATISFACTION OF THE ENGINEER AND/OR AUTHORITIES.

10. IF WIND EROSION BECOMES SIGNIFICANT DURING CONSTRUCTION, THE


CONTRACTOR SHALL STABILIZE THE AFFECTED AREA USING SPRINKLING,
IRRIGATION OR OTHER ACCEPTABLE METHODS.

11. ALL EXISTING SIDEWALK CRACKED OR DAMAGED SHALL BE REPLACED.

DATUM NOTE
DATUM CONVERSION

0.00' NAVD88 = 0.83 NGVD29

DITCH BOTTOM INLET

PARTIAL INLET COMPLETED INLET PROTECTION AROUND INLETS OR SIMILAR R

STRUCTURES - FDOT INDEX 102


SILT FENCE DETAIL
DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

LEGEND
DATUM NOTE
DATUM CONVERSION EC EC

0.00' NAVD88 = 0.83 NGVD29


TB TB

R
GENERAL DEMOLITION NOTES:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISCONNECTION OF UTILITY SERVICES
TO THE EXISTING STRUCTURES PRIOR TO DEMOLITION OF THE BUILDINGS. THE CONTRACTOR
SHALL COORDINATE WITH RESPECTIVE UTILITY COMPANIES PRIOR TO THE REMOVAL AND/OR
RELOCATION OF UTILITIES.
2. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY CONCERNING PORTIONS
OF WORK WHICH MAY BE PERFORMED BY THE UTILITY COMPANY'S FORCES AND ANY FEES
WHICH ARE TO BE PAYED TO THE UTILITY COMPANY FOR THEIR SERVICES.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF ALL
STRUCTURES, PADS, WALLS, FLUMES, FOUNDATIONS, PARKING, DRIVES, DRAINAGE
STRUCTURES, UTILITIES, ETC., SUCH THAT THE IMPROVEMENTS SHOWN ON THE REMAINING
PLANS CAN BE CONSTRUCTED. ALL FACILITIES TO BE REMOVED SHALL BE UNDERCUT TO
* CON
SUITABLE MATERIAL AND BROUGHT TO GRADE WITH SUITABLE, COMPACTED FILL MATERIAL NE
ER
S ST
R
PER THE SPECIFICATIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS INVOLVED

UC
NG
C

T
C IV I L E

I ON I NS PEC
AND IS RESPONSIBLE FOR REMOVING AND DUMPING THE DEBRIS IN AN APPROVED, LAWFUL
MANNER. E
4. ALL EXISTING UTILITIES ARE TO BE REMOVED, TERMINATED AND CAPPED AT THE I

T
OR
RS
RIGHT-OF-WAY. ALL EXISTING METERS, VALVES, ETC. ARE TO BE REMOVED UNLESS PLA N
NE *
S

OTHERWISE NOTED ON THE PLANS.


5. ALL EXISTING SERVICE LINES FOR TELEPHONE, ELECTRIC, SEWER, AND CABLE T.V. SERVICES

6.
ARE TO BE REMOVED TO EXISTING TRUNK LINES UNLESS OTHERWISE NOTED ON THE PLANS.
ALL AREAS WHERE PAVEMENT, STRUCTURE SLABS, FOUNDATIONS, UTILITIES, CONDUITS,
CAMPO
AND/OR UTILITY STRUCTURES HAVE BEEN REMOVED SHALL BE BACKFILLED WITH SELECT ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726
BACKFILL MATERIAL. ALL SELECT BACKFILL MATERIAL SHALL BE PLACED AND COMPACTED
PER THE REQUIREMENTS OF SPECIFICATIONS AND THE OWNERS GEOTECHNICAL ENGINEER. 1725 EAST 5TH AVENUE
7. ALL EXISTING FENCES, SIGNS, POWER POLES, AND LIGHT POLES LOCATED ON-SITE SHALL BE TAMPA, FL. 33605
DEMOLISHED AND REMOVED UNLESS OTHERWISE NOTED. PHONE: (813) 215-7372
8. EXISTING CAST IN PLACE SEPTIC TANKS (IF FOUND ON-SITE) SHALL BE PUMPED BY A LICENSED FAX: (813) 902-8782
CONTRACTOR. THE SEPTIC TANK SHALL THEN BE REMOVED AND THE AREA BACKFILLED PER
THE PROJECT SPECIFICATIONS UNLESS OTHERWISE NOTED. ALL WORK SHALL BE IN
ACCORDANCE WITH HEALTH DEPARTMENT REQUIREMENTS.
9. CONTRACTOR IS RESPONSIBLE FOR WALKING SITE AND DETERMINING EXTENTS OF
DEMOLITION WORK PRIOR TO BID DATE.
10. PRIOR TO ANY WORK ONSITE, THE CONTRACTOR SHALL CONTACT THE ONE CALL SYSTEM.
THE CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY REMOVALS WHETHER LOCATED BY THE
ONE CALL SYSTEM OR NOT.
11. CONTRACTOR SHALL COORDINATE REMOVAL OF EXISTING ELECTRICAL SERVICES ON SITE
WITH THE POWER COMPANY. POWER COMPANY IS RESPONSIBLE FOR THE DISCONNECTION
AND REMOVAL OF EXISTING SERVICES UNLESS OTHERWISE NOTED.
12. LIMITS OF PAVEMENT SHOWN TO BE REMOVED ARE APPROXIMATE AND FOR REFERENCE
ONLY. CONTRACTOR SHALL FIELD VERIFY THE LIMITS OF PAVEMENT TO DETERMINE THE
EXTENT OF THE EXISTING PAVEMENT TO BE REMOVED.
13. IF NOT SHOWN ON THE DEMOLITION DRAWINGS, THE CONTRACTOR SHALL REMOVE ALL
EXISTING MATERIALS AS NECESSARY TO COMPLETE ALL NEW WORK AS REQUIRED BY OTHER
PORTIONS OF THE CONTRACT DOCUMENTS.
14. SALVAGE RIGHTS FOR ALL DEMOLISHED MATERIALS SHALL BE FIRST GIVEN TO THE OWNER.
ANY MATERIALS NOT RETAINED BY THE OWNER SHALL BE REMOVED FROM THE SITE AND
DISPOSED OF BY THE CONTRACTOR AT THE CONTRACTORS EXPENSE.
15. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL LOCAL, STATE AND FEDERAL
REGULATIONS IN THE REMOVAL/DEMOLITON OF HAZARDOUS MATERIALS.
16. THE CONTRACTOR IS RESPONSIBLE TO VERIFY EXISTING UTILITIES PRIOR TO DEMOLITION &
EXCAVATION.
17. CONTRACTOR IS RESPONSIBLE FOR ALL REGISTRATIONS, PERMITS AND FEES REQUIRED TO
REMOVE & PROPERLY DISPOSE OF ALL DEMOLITION MATERIALS.
18. DEMO CONTRACTOR IS RESPONSIBLE FOR OBTAINING APPROVALS AND NOTIFICATIONS TO
ALL LOCAL, STATE AND FEDERAL AUTHORITIES.
19. REFER TO SURVEY FOR LIMITS AND BOUNDARY OF PROPERTY .

GENERAL DEMOLITION SPECIFICATIONS: NAME SEAL NO. DATE

1. CONDITIONS EXISTING AT TIME OF INSPECTION FOR BIDDING PURPOSE WILL BE MAINTAINED BY


OWNER AS FAR AS PRACTICAL..
2. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST
DAMAGE DURING DEMOLITION OPERATIONS.
3. DRAIN, PURGE, OR OTHERWISE REMOVE, COLLECT, AND DISPOSE OF CHEMICALS, GASES,
EXPLOSIVES, ACIDS, FLAMMABLES OR OTHER DANGEROUS MATERIALS BEFORE PROCEEDING
WITH DEMOLITION OPERATIONS ACCORDING TO APPLICABLE CODES OR REGULATIONS.
4. EMPLOY A CERTIFIED, LICENSED EXTERMINATOR TO TREAT BUILDING AND TO CONTROL
RODENTS AND VERMIN BEFORE AND DURING DEMOLITION OPERATIONS.
5. DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, OR OTHER ADJACENT OCCUPIED OR USED
FACILITIES WITHOUT PERMISSION FROM OWNER AND AUTHORITIES HAVING JURISDICTION.
PROVIDE ALTERNATE ROUTES AROUND CLOSED OR OBSTRUCTED TRAFFIC WAYS IF REQUIRED
BY GOVERNING REGULATIONS. PROVIDEALTERNATE ROUTES AND SIGNAGE FOR SIDEWALKS ON
WHEATLAND AND COCKRELL HILL ROADS, DURING THE DEMOLITION AND RECONSRUCTION OF
THE SIDEWALK.
6. DO NOT CREATE HAZARDOUS OR OBJECTIONABLE CONDITIONS, SUCH AS ICE, FLOODING, AND
POLLUTION, WHEN USING WATER. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL
PREVENT SPILLAGE ON ADJACENT SURFACES AND AREAS.
7. REMOVE DEBRIS FROM ELEVATED PORTIONS OF BUILDING BY CHUTE, HOIST, OR OTHER DEVICE
THAT WILL CONVEY DEBRIS TO GRADE LEVEL.
8. PROMPTLY DISPOSE OF DEMOLISHED MATERIALS. DO NOT ALLOW DEMOLISHED MATERIALS TO
ACCUMULATE ON-SITE.
9. DO NOT BURN DEMOLISHED MATERIALS.

PASCO COUNTY NOTES:


1. IF DURING CONSTRUCTION ACTIVITIES ANY EVIDENCE OF HISTORIC RESOURCES, INCLUDING
BUT NOT LIMITED TO ABORIGINAL OR HISTORIC POTTERY, PREHISTORIC STONE TOOLS, BONE
OR SHELL TOOLS, HISTORIC TRASH PITS, OR HISTORIC BUILDING FOUNDATION, ARE
DISCOVERED, WORK SHALL COME TO AN IMMEDIATE STOP AND THE FLORIDA DEPARTMENT OF
HISTORIC RESOURCES (STATE HISTORIC PRESERVATION OFFICER) AND PASCO COUNTY SHALL
BE NOTIFIED WITHIN TWO WORKING DAYS OR THE RESOURCES FOUND ON THE SITE.

2. IF DURING CONSTRUCTION ACTIVITIES ANY EVIDENCE OF THE PRESENCE OF STATE AND


FEDERALLY PROTECTED PLANT AND/OR ANIMAL SPECIES IS DISCOVERED, WORK SHALL COME
TO AN IMMEDIATE STOP AND PASCO COUNTY SHALL BE NOTIFIED WITHIN TWO WORKING DAYS
OF THE PLANT AND/OR ANIMAL SPECIES FOUND ON SITE.

3. NO CONSTRUCTION ACTIVITIES INCLUDING: CLEARING, GRADING, GRUBBING SHALL OCCUR


WITHIN THE WETLAND UPLAND BUFFERS AS DEPICTED ON THE APPROVED PROJECT
CONSTRUCTION PLANS.

4. PRIOR TO THE START OF THE CLEARING AND GRUBBING, OR ANY SOIL DISTURBANCE CONTACT
PC STORMWATER MGMT AT (727) 834-3611 FOR A SOIL EROSION AND SEDIMENT CONTROL,
PRE-INSPECTION MEETING.

5. CONTRACTOR MUST PROVIDE A DEWATERING PLAN, IF APPLICABLE, TO PASCO COUNTY


ENGINEERING INSPECTIONS DEPARTMENT AT (727) 834-3670 PRIOR TO THE EROSION CONTROL
MEASURES PRE-INSPECTION MEETING.

NOTE:
ALL AREAS DISTURBED DURING CONSTRUCTION
SHALL BE FINAL DRESSED AND SODDED BACK
R
DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

SIGNAGE INVENTORY TABLE


LEGEND

SITE DATA TABLE

S * CON
ER ST
NE R

UC
NG
C

TI
C IV I L E

ON I NS PE
E
I

CT
OR
RS S
NE
PLA N *

CAMPO
ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

1725 EAST 5TH AVENUE


TAMPA, FL. 33605
PHONE: (813) 215-7372
FAX: (813) 902-8782

NAME SEAL NO. DATE

SITE PLAN NOTES:


1. ALL WORK AND MATERIALS SHALL COMPLY WITH PASCO COUNTY REGULATIONS AND
CODES AND O.S.H.A. STANDARDS.
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND
DIMENSIONS OF TOWERS, SLOPE PAVING, COLUMNS, DOOR LOCATIONS, AND UTILITY
ENTRANCES.
3. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED,
REMOVED, OR RELOCATED PER PLANS. ALL COST SHALL BE INCLUDED IN BASE BID.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS INCLUDING BUT NOT
LIMITED TO, ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS AND POLES,
ETC. AS REQUIRED PER PLANS.
5. ALL CURB DIMENSIONS ARE TO THE FACE OF GUTTER OF CURB UNLESS OTHERWISE
NOTED.
6. ALL BUILDING DIMENSIONS ARE TO THE FACE OF STRUCTURAL CMU.
7. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL AREAS INDICATED TO
REMAIN UNDISTURBED OR TO REMAIN AS BUFFERS, ALL PROPERTY CORNERS, AND
REPLACING ALL PINS ELIMINATED OR DAMAGED DURING CONSTRUCTION.
8. CONTRACTOR SHALL MATCH EXISTING PAVEMENT IN GRADE AND ALIGNMENT.
9. INSTALLATION OF FUEL STORAGE TANKS REQUIRES REVIEW AND APPROVAL BY THE FIRE
MARSHAL AND THE ISSUANCE OF A SEPARATE BUILDING PERMIT. APPROVAL OF THE SITE PLAN
DOES NOT CONSTITUTE APPROVAL OF THE LOCATION OF THE FUEL TANKS.

PASCO COUNTY SIGNING & MARKING


NOTES

STORMWATER NOTES

KEY NOTES
1 R
DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

LEGEND

S * CON
ER ST
NE R

UC
NG
C

TI
C IV I L E

ON I NS PE
E
I

CT
OR
RS S
NE
PLA N *

CAMPO
ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

1725 EAST 5TH AVENUE


TAMPA, FL. 33605
PHONE: (813) 215-7372
FAX: (813) 902-8782

TEMPORARY ACCESS DRIVE ASPHALT PAVEMENT SECTION (*)


NTS

NAME SEAL NO. DATE

SIGNAGE INVENTORY TABLE

R
DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

LEGEND
DATUM NOTE
DATUM CONVERSION

0.00' NAVD88 = 0.83 NGVD29

A
C-5

TB TB

TB TB

EC EC
S * CON
ER ST
NE R
RD

UC
NG
C

T
C IV I L E

I ON I NS PEC
STM STM
E
I

T
OR
RS S
NE
PLA N *

GRADING PLAN NOTES:


1. TOPOGRAPHIC INFORMATION WAS TAKEN FROM A TOPOGRAPHIC SURVEY BY CAMPO
GEOPOINT SURVEYING, LLC. IF CONTRACTOR DOES NOT ACCEPT EXISTING ENGINEERING, INC.
TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

MADE, AT HIS EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND 1725 EAST 5TH AVENUE
SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. TAMPA, FL. 33605
2. CONTRACTOR SHALL VERIFY HORIZONTAL AND VERTICAL LOCATION OF ALL PHONE: (813) 215-7372
EXISTING STORM SEWER STRUCTURES, PIPES, AND ALL UTILITIES PRIOR TO FAX: (813) 902-8782
CONSTRUCTION.
3. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND /OR
ELEVATION OF ALL EXISTING UTILITIES (ABOVE AND BELOW GROUND) AS SHOWN
ON THESE PLANS ARE APPROXIMATE AND WERE LOCATED BASED ON EITHER
VISUAL OBSERVATIONS AT THE SITE, EXISTING SURVEYS, AND/OR FROM UTILITY
OWNERS.
4. RACETRAC PETROLEUM DOES NOT GUARANTEE THAT EXISTING UTILITY
LOCATIONS ARE EXACT. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO DETERMINE THE EXACT LOCATIONS OF EXISTING UTILITIES (ABOVE AND BELOW
GROUND) BEFORE BEGINNING ANY CONSTRUCTION. THE CONTRACTOR SHALL
CALL APPROPRIATE UTILITY COMPANIES AND THE UTILITIES PROTECTION CENTER
AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATIONS OF UTILITIES.
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY OWNER AND /
OR ENGINEER OF ANY UTILITY CONFLICTS WITH THE PROPOSED IMPROVEMENTS
SHOWN ON THE PLANS.
6. ALL CUT OR FILL SLOPES SHALL BE X:1 OR FLATTER UNLESS OTHERWISE NOTED.
7. EXISTING DRAINAGE STRUCTURES TO BE INSPECTED AND REPAIRED AS NEEDED,
AND EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILTS AND DEBRIS.
8. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING
CONSTRUCTION, IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR
AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO
EXISTING CONDITIONS OR BETTER.
9. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE
CONNECTION AT STRUCTURE IS WATERTIGHT.
10. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH
PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING AND COVERS.
11. THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS AS OUTLINES
IN THE GENERAL N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED
WITH CONSTRUCTIONS ACTIVITIES.
12. CONTRACTOR SHALL SSURE POSITIVE DRAINAGE AWAY FROM BUILDING AND FOR
ALL NATURAL AND PAVED AREAS.
NAME SEAL NO. DATE
13. ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4
INCHES OF TOPSOIL CONTRACTOR SHALL GRASS DISTURBED AREAS IN
ACCORDANCE WITH CITY / COUNTY SPECIFICATIONS UNTIL HEALTHY STAND OF
GRASS IS OBTAINED.
14. ALL RETAINING WALLS TO BE PROTECTED DURING BACKFILL BY CONTRACTOR.
THIS INCLUDES BUT IS NOT LIMITED TO, PROVIDING AND INSTALLING PROPER
BRACING DURING BACKFILL BEING PLACES ADJACENT TO RETAINING WALLS.
15. CONTRACTOR TO REVIEW BORING LOGS PROVIDED BY RACETRAC.
16. CLEARING AND GRUBBING LIMITS SHALL INCLUDE ALL AREAS DISTURBED BY
GRADING OPERATIONS. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION
OF ALL UNDISTURBED AREAS, ALL PROPERTY CORNERS, AND REPLACING ALL
PINS ELIMINATED OR DAMAGED DURING CONSTRUCTION
17.PROPOSED SPOT ELEVATIONS REPRESENT FINISHED PAVEMENT OR GROUND
SURFACE GRADE UNLESS OTHERWISE NOTED ON DRAWINGS.
18. CONTRACTOR SHALL TRIM, TACK, AND MATCH EXISTING PAVEMENT AT LOCATIONS
WHERE NEW PAVEMENT MEETS EXISTING PAVEMENT
19. ALL GRADING OPERATIONS SHALL SHALL BE STAKED BY A REGISTERED CIVIL
ENGINEER OR LICENSED LAND SURVEYOR APPROVED BY THE OWNER.
20.EXISTING MANHOLES AND VALVE BOXES TO REMAIN IN PLACE SHALL BE ADJUSTED
TO FINAL GRADES.

PASCO COUNTY NOTES:


DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

LEGEND

TB TB

EC EC

RD

STM STM

STRUCTURE DATA PIPE DATA


110 LF 18" ADS HP
FDOT TYPE C INLET
STORM @ 0.36%
GRATE EL = 54.50
INV EL = 51.50 (N) 79 LF 18" ADS @ 0.38%

FDOT TYPE C INLET 48 LF 24" ADS @ 0.62% S * CON


ER ST
GRATE EL = 54.75 NE R

UC
NG
INV EL = 50.50 (NW) 233 LF 24" ADS @ 0.34% C

T
C IV I L E

I ON I NS PEC
E
FDOT TYPE C INLET 162 LF 24" ADS @ 0.37% I

T
OR
GRATE EL = 55.92 NE
RS S
33 LF 24" ADS @ 0.33% PLA N *
INV EL = 49.80 (N & SE)

CAMPO
55 LF 24" ADS @ 0.35%
FDOT TYPE C INLET
GRATE EL = 54.50 132 LF 24" ADS HP @ 0.30%
INV EL = 51.10 (N) ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

FDOT TYPE C INLET 46 LF 18" ADS @ 0.87% 1725 EAST 5TH AVENUE
GRATE EL = 54.50 TAMPA, FL. 33605
INV EL = 50.70 (W&S) PHONE: (813) 215-7372
FAX: (813) 902-8782
FDOT TYPE C INLET
GRATE EL = 55.89
INV EL = 49.90 (E & W)
INV EL = 51.00 (S)

FDOT TYPE C INLET


GRATE EL = 55.00
INV EL = 49.30 (E & S)

EX. GRATE INLET


TOP EL = 53.42
EX INV EL = 48.01(W)
PROP INV EL = 49.00 (S)
PROP INV EL = 49.00 (N)

TYPE J STORM MANHOLE


RIM EL = 55.60
INV EL = 50.20 (SE & N)

FDOT TYPE "D" INLET


GRATE EL = 54.05
INV EL = 49.11 (N&S)

GENERAL NOTES

NAME SEAL NO. DATE

GEOWALL FINISH DETAILS


DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

EX SKIMMER
95" WIDE

3 1/8"

1 1/2"
5/8"

REMOVE EXIST (2) 24" RCP


& REPLACE W/ SINGLE 42"
1 1/4"
RCP

METAL POST

EXISTING SKIMMER
TOP EL = 54.66
EXIST GRATE TOP EL "D-1"
PROPOSED GRATE TOP EL "D-2"
3/8" x 3" SS FASTENERS @
12" O.C. (MIN. 2 EA. SIDE)
CONTRACTOR TO SAW CUT
EXISTING STRUCTURE TOP
TO PROPOSED ELEVATION 1'-0"
INTERNATIONAL SYMBOL OF
ACCESS (SEE NOTE 5)

TOP BLUE / WHITE BACKGROUND

1'-6"
BOTTOM WHITE / BLACK
BACKGROUND SEE DETAIL BELOW

WHITE BACKGROUND

0'-6"
BLACK LEGEND & BORDER

S * CON
3/8" HOLES WITH HOLES DRILLED ON 1" ER ST
NE R
CENTERS FULL LENGTH IN METAL POST.

UC
NG
REMOVE EXIST (2) 24" RCP C

T
C IV I L E
REMOVE EXIST (2) 24" RCP (MOUNT AND BOTTOM OF SIGN) WITH 5/16"

I ON I NSPEC
& REPLACE W/ SINGLE 42"
& REPLACE W/ SINGLE 42" x 2 1/4" BOLTS, TOP
E

7'-0"
RCP
RCP I

T
OR
RS S
NE
METAL POST P LAN *

UNDERDRAIN DETAIL PER FDOT INDEX 286 ROOF LEADER CONNECTION DETAIL TRENCH BACKFILL DETAIL
NTS
NTS NTS
CAMPO
ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

2'-0"
1725 EAST 5TH AVENUE
TAMPA, FL. 33605
PHONE: (813) 215-7372
EXISTING CONTROL STRUCTURE S-101 TO BE MODIFIED FAX: (813) 902-8782
NTS 1'-0"
CONCRETE
FOOTING

FACE OF CURB OR EDGE


OF PAVEMENT

SIDEWALK RAMP SHALL HAVE

10'
DETECTABLE WARNING NOTES:
TEXTURE. SEE "FLORIDA
BOARD OF BUILDING CODES 1. METAL POST TO BE GALVANIZED. ALL BOLTS, NUTS, WASHERS AND
AND STANDARDS" 4.7. SCREWS MUST BE RUSTPROOF.
2. CONCRETE FOR FOOTING SHALL BE PORTLAND CEMENT AND HAVE A

WHITE

BLUE
MINIMUM COMPRESSIVE STRENGTH OF 3,000 p.s.i.
3. SIGNS WILL BE FABRICATED BY USING REFLECTING COATING IN THE
1:12 1:12 SYMBOL, MESSAGE AND BORDER APPLIED TO A SHEET ALUMINUM
BACKING (.080) IN THICKNESS.

3' TO 5' SQUARE


4. MESSAGE LETTERING SHALL BE UPPER CASE (WHITE)(SERIES B) 2" HIGH
THREE 6" WHITE STRIPES
IN ACCORDANCE WITH MANUAL ON UNIFORM TRAFFIC CONTROL
@ 60° ANGLES DEVICES.

2'
5. THE SYMBOL IS COMPOSED OF TWO ELEMENTS, A WHITE WHEELCHAIR
FIGURE (WHICH SHOULD ALWAYS FACE RIGHT) ON A SQUARE
BACKGROUND, INTERNATIONAL BLUE IN COLOR (FED. STD. 595a, COLOR
#15180).
6. SIGN POST SHALL BE MIN. 2'-0" CLEAR FROM BACK OF CURB.

12' 5' 12' 2"


3' TO 5' SQUARE

WHITE
BLUE
WHITE

BLUE
FRONT BOLLARD
MANDATORY 6" 6"
White 6" 6"
NAME SEAL NO. DATE
6" WHITE STRIPES INSIDE
6" BLUE STRIPES OUTSIDE

RIBBON BIKE RACK DETAIL BOLLARD DETAIL ON-SITE HEAVY DUTY ASPHALT PAVEMENT SECTION HANDICAP SIGNAGE DETAILS PER FDOT INDEX 17346 & 17355
NTS NTS NTS NTS

4'
TOOL WITH FILL WITH JOINT
1/8" RAD. SEALANT (TYP.)

D TRANSVERSE JOINT

TRANSVERSE JOINT

TYPE 'A' UNDOWELED


CONTRACTION (CONTROL) JOINT LONGITUDINAL
JOINT 1/2" ISOLATION
N.T.S.
JOINT W/SEALANT
UNDOWELED TRANSVERSE CONTRACTION OR LONGITUDINAL TYPE 'D' BUTT JOINT
JOINT, SAWED OR PRE-MOLDED. DO NOT DOWEL
PAVEMENTS LESS THAN 7" THICK N.T.S.

ISOLATION JOINT FOR PAVEMENTS LESS 1' MIN. LONGITUDINAL


JOINT
THAN 8" THICK.

1/2" ISOLATION 4" CONC PAD


BUTT TYPE CONSTRUCTION JOINT JOINT W/SEALANT
IF SIDEWALK JOINTS EQUAL AND
ALIGN WITH PARKING LOT JOINTS;
OTHERWISE USE 1/2" ISOLATION JOINT

6"
JOINTS AT MANHOLE
D
N.T.S.

TYPE 'A' CONTRACTION


CONCRETE SIDEWALK DETAIL
JOINT PREFERRED (TYP.) NTS
THICKENED EDGE TYPE 'B' ACCEPTABLE
ALTERNATE
N.T.S.
STEEL
GRATE
SIDEWALK/CURB
N.T.S.

GENERAL NOTES:
1. USE ACI OR FC&PA CERTIFIED FLATWORK FINISHER
2. USE ACI 330R-01 GUIDE FOR DESIGN AND CONSTRUCTION OF CONCRETE PARKING LOTS MAX. JOINT SPACING
3. USE ACI 330.1-94 STANDARD SPECIFICATION FOR PLAIN CONCRETE PARKING LOTS
4. ALL CONCRETE USED IN PARKING LOT SHALL HAVE A COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS. TO NEXT JOINT
(TYP.)
PLAN
5. PREPARE THE SUBGRADE IN ACCORDANCE WITH THE GEOTECHNICAL ENGINEEER'S
RECOMMENDATIONS FOR RIGID PAVEMENTS. SUBGRADE SOIL DENSITY TESTING MUST BE
1/2" ISOLATION JOINT
COMPLETED AND VERIFIED BY THE GEOTECHNICAL ENGINEER PRIOR TO CONCRETE PLACEMENT. W/SEALANT
6. IMPORTED SOIL USE FOR BACK FILL SHOULD BE FREE OF HEAVY CLAY, SILTS, STONES, PLANT
ROOT OR OTHER FOREIGN MATERIAL GREATER THAN 121" IN DIAMETER IN ORDER TO ACHIEVE
ADEQUATE COMPACTION AROUND ANY FIXED OBJECT IN GROUND. ALTERNATE WILL BE TO
USE FLOWABLE FILL.
7. LAYOUT CONTROL JOINT BY STARTING WITH ANY DRAINAGE INLET WITHIN THE PAVEMENT
SECTION AND WORK TOWARD EDGE OF PAVEMENT JOINTS AT INLETS
8. KEEP ALL JOINTS CONTINUOUS
9. CONTROL JOINTS SHALL BE FORMED OR SAWED WITHIN 12 HOURS FROM TIME OF PLACEMENT; N.T.S.
A. SIDEWALK-SPACING SHALL BE SAME AS WIDTH OF PAVEMENT AND LESS THAN 5 FEET
IN LENGTH
B. PAVEMENT-MAXIMUM SPACING SHALL BE 2.5 TIMES THICKNESS IN UNIT OF FEET
AND LESS THAN 15 FEET IN LENGTH (E.G. T=4 INCH SPACING AT 10'x10')
10. CURE CONCRETE IMMEDIATELY AFTER FINISHING OPERATION IS COMPLETED BY USING ONE OF
THE FOLLOWING METHODS: WATER, PIGMENTED WATER-BASED CURING COMPOUND OR
VISQUEEN AND BURLAP

CURBS:
1. ALL CURBING SHALL BE CONSTRUCTED OF CONCRETE THAT WILL OBTAIN A MINIMUM
TYPE A
COMPRESSIVE STRENGTH OF 4,000 PSI (MIN) AT 28 DAYS NOTES:
2. ALL CONCRETE CURBS SHALL BE SPACED WITH A FULL-DEPTH, 21" WIDTH ISOLATION JOINT
MATERIAL PRIOR TO PLACEMENT OF ADJACENT CONCRETE PAVEMENT 1. CONCRETE TO BE 4,000 P.S.I.
3. THERE SHALL BE CONTROL JOINTS, EITHER TOOL OR SAW-CUT, MATCH PAVEMENT JOINTS, UNLESS
4" CONC PAD
2. WHEEL STOPS TO BE SECURED TO PAVEMENT WITH TWO 18" NO. #5 BARS. EL = 51.50
OTHERWISE SPECIFIED; JOINTS SHALL BE FORMED WITHIN 12 HOURS OF PLACEMENT
4. ALL CURB ENDS THAT DO NOT TIE INTO OTHER FACILITIES SHALL TRANSITION DOWN TO PAVEMENT
3. RECYCLED PLASTIC WHEEL STOPS MAY BE USED IN LIEU OF CONCRETE. SECTION SIDE
GRADE IN 24 INCHES 4. DIMENSIONS OF WHEEL STOPS MAY DIFFER FROM THE ABOVE SPECIFICATIONS IF
5. CONSTRUCTION JOINT SHALL BE TIED WITH A No.4 TIE BAR EXTENDED 6 INCHES INTO EACH CURB APPROVED BY ENGINEER.
SECTION AND SHALL BE SPACED WITH A FULL-DEPTH 21" WIDTH ISOLATION JOINT MATERIAL

WHEEL STOP DETAIL ON-SITE RAISED SIDEWALK DETAIL


CONCRETE JOINT DETAILS NTS CONTROL STRUCTURE CS-1
NTS NTS
NTS
DocuSign Envelope ID: 6000F04B-FAF9-4E7E-B71B-29FF34A0EFCC

70 70 70 70 70 70

EXISTING 17'
FDOT RIGHT OF WAY FDOT SR 54RIGHT OF WAY FDOT EASEMENT

PROPOSED 5'
EASEMENT

5' CROSS WALK BEXLEY VILLAGE DR ROW


6'
2% MAX CROSS SLOPE
SHOULDER 18' PARKING STALL 24' DRIVE AISLE
4' TALL
FENCE
60 60 60 RELOCATED 2" AIR
60 60 60
EXISTING DITCH RELEASE VALVE PROPOSED
PROPOSED SILT FENCE
PROPOSED
ASPHALT SILT FENCE
PAVEMENT

3.4'
3.42' PROPOSED
CONC. S/W PROPOSED
EXISTING GROUND 1.47'
EXISTING GROUND CONCRETE
PAVEMENT PROPOSED * CON
S
EXISTING GROUND ER ST
PROPOSED CONCRETE NE R

UC
NG
CONCRETE PAVEMENT
C

T
C IV I L E

I ON I NSPEC
PAVEMENT
50 50 50 50 50 50 E
EXISTING 12" FORCEMAIN I

T
OR
RS S
NE
P LAN *

EXISTING 12"
FORCEMAIN

CAMPO
ENGINEERING, INC.
FBPR CERTIFICATE OF AUTHORIZATION NO.: 26726

1725 EAST 5TH AVENUE


TAMPA, FL. 33605
PHONE: (813) 215-7372
FAX: (813) 902-8782

40 40 40 40 40 40

0+00 0+88 0+00 1+00 1+50 0+00 1+00


1+05

A CROSS SECTION B CROSS SECTION C CROSS SECTION


2.1 SCALE: HOR 1" = 20' 2.1 SCALE: HOR 1" = 20' 2.1 SCALE: HOR 1" = 20'
VER 1" = 5' VER 1" = 5' VER 1" = 5'

NAME SEAL NO. DATE

70 70 70 70 70 70

ADJACENT PARCEL ADJACENT PARCEL

BEXLEY VILLAGE DR ROW

UPLAND
BUFFER PER
ERP

60 60 60 PROPOSED
60 60 43024788.004
60
CONC. S/W
PROPOSED
SILT FENCE

3.44'
3.35' 1.91'

EXISTING GROUND PROPOSED


CONCRETE
PROPOSED PAVEMENT EXISTING
EXISTING CONCRETE EXISTING GROUND GROUND
PAVEMENT PAVEMENT

50 50 50 50 50 PROPOSED 50
CONCRETE
PAVEMENT

40 40 40 40 40 40

0+00 1+00
1+05 0+00 0+55 0+00 0+75

D CROSS SECTION E CROSS SECTION F CROSS SECTION


2.1 SCALE: HOR 1" = 20' 2.1 SCALE: HOR 1" = 20' 2.1 SCALE: HOR 1" = 20'
VER 1" = 5' VER 1" = 5' VER 1" = 5'