Radiology System 550 mA BRAND / MANUFACTURER Siemens
MODEL / TYPE Multix Select DR
OUTSOURCE EXTERNAL MANUFACTURE (OEM) no PRODUCT'S REGISTRATION (AKL/AKD) AKL 21501212379 PRODUCT'S CERTIFICATION FDA Clearance yes CE Mark (MDD) yes IEC Compliance (Diisi daftar standar IEC yang dipenuhi) IEC 60601 Certificate .... ISO 13485 Locally Content (Tingkat Komponen Dalam Negeri) WHERE MARKETED Worldwide REFERENCE OF TECHNICAL CONFIGURATION digital floor-mounted x-ray system complete with patient table and bucky wall stand Over/under table overtable Remote operation yes IMAGING TOWER floor mounted Longitudinal movement, cm (in) 138 cm Vertical movement, cm (in) 35 cm to 185 cm Maximum SID, cm (in) 115 cm at table Controls High-performance PC with flat panel display and user interface. Control console. Table/tower movement Footswitch for the control of 8- way tabletop float movements. Manual movement of x-ray tube. Radiography yes Removable grid yes DETECTOR yes, wired Flat Panel Detector Detector type Amorphous silicon (a-Si) Detector size, cm (in) 35 cm x 43 cm Field sizes, cm (in) 35.3 cm x 42.4 cm (active area) RADIOGRAPHY, SPOT FILMING Acquisition matrix size 3072 x 2560 pixels Maximum spatial resolution 3.6 lp/mm Acquisition bit depth 14 bits with 8-fold oversampling RADIOGRAPHY, CONVENTIONAL Digital detector yes, wired Flat Panel Detector In table yes On tower yes Vertical, chest yes Cross table yes PATIENT TABLE Maximum patient weight, kg (lb) 200 kg Tabletop dimensions, cm (in) 235 cm x 80 cm Lateral movement, cm (in) ± 10 cm, transverse Longitudinal movement, cm (in) ± 46 cm, longitudinal Minimum height, cm (in) 75 cm Table tilt, ° - BUCKY WALL STAND Vertical movement range 35 cm to 185 cm Grid Stationary grid Front-cover-to-detector distance < 40 mm X-RAY PRODUCTION Generator power, kW 55 kW Preferred x-ray tubes POLYDOROS/OPTITOP Radiographic kVp 40 kV to 133 kV Radiographic mA range 550 mA at 100 kV Dose area product Yes IMAGE DISPLAY Control room monitor size 19" monitor CONNECTIVITY DICOM yes ACCESSORIES Handgrips yes REMOTE DIAGNOSTICS yes POWER REQUIREMENTS 3-phase, 380/400 V ±10%, 50/60 Hz, 3-phase, 440/480 V ±10%, 50/60 Hz wih pre-transformer
OTHER REQUIREMENTS (room size, wall etc) min. 3.5 m x 4.7 m
FUNCTION Digital Floor Mounted Radiography System OTHER INFORMATION *) *) Example : Delivery Time, Capacity of Production, Price, Delivery time 3-4 months Commitment of Maintenance, Warranty, Discontinue/Life Warranty 1 year Time Medical Device, etc. Preventive maintenance 2x/ year Spareparts availability up to 10 years