Professional Documents
Culture Documents
>>>> www.memmert.com
Inner chamber made exclusively of high-grade fully recyclable
stainless steel 1.4301 (ASTM 304). Exceptionally smooth and
hygienic surfaces help to simplify spotless cleaning.
Stainless steel –
high-grade material
Functional design in its most elegant form:
scratch-resistant, robust and durable. Over many
years of practical application, high-grade stain-
less steel has proved to be superior to coated
sheet steel, which can corrode rapidly during
extended use.
0
Exceptionally quiet and smooth-running 250
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Inner chamber hermetically sealed, so there 0
Temperature °C
is no exchange of interior air, providing 3 6 9 12
Months
Temperature and humidity test points defined in the protection from contamination
guideline
Extremely high control precision Energy cost comparison HPP (Peltier technology) with conven-
tional unit (compressor cooling) during a stability test acc. to
ICH* (25 °C, 60% rh) – based on competitors’ specifications
Active humidification Heating and cooling in a
and dehumidification single system
Fan Climate protection with a
In particular, a stable and precisely adjustable re-
lative humidity in the working range of 10-90%
Heat dissipation conservation effect
is of crucial importance in maintaining a constant This premium class energy saver reduces strain
climate during stability testing for pharmaceuti- on the climate, at the same time notably
cal products. Your benefits: setpoint temperatures reducing test costs. The main part of ongoing
and humidity can be adhered to with precision, Cooling operation stability testing is performed at temperatures
Peltier element
even in regions with a high ambient temperature Insulated chamber between 20 °C and 30 °C – that is, close to the
and extremely high or low humidity. ambient temperature. The impressive economy of
Fan
Peltier technology can be seen here, since only
Ambient heat
small amounts of energy are required to raise
or lower the temperature slightly, in comparison
with compressor technology.
Heating operation
Peltier element
Insulated chamber
3
Reliable and accurate almost
for eternity!
4
Timer module Temperature module Monitor module
1 Time indication (here real time) 22 Heating 25 Visual alarm
2 Text messages 23 Setpoint/actual temperature 26 Alarm limit
24 Cooling (active) 27 Sounder on alarm
28 LOW alarm limit
Temperature adjustment: 29 Automatic alarm limit (ASF)
+5°C – +70°C 30 Temperature limiter
Variation (time): ± 0,1 °C max. 31 HIGH alarm limit
Uniformity (spatial): ± 0,4 °C at 10°C
Acoustic and visual alarm on
temperature and humidity out of
limit and on other errors
1 8 9 10 11 15 12 13 14 22 23 24 25 26 27 32
2 17 3 4 5 6 7 16 18 30 28 29 31 33 34
19 20 21
D F 38
Interfaces:
75 A 75 USB interface C
USB printer interface
parallel
interface
197
supply cable 10
optional Ethernet
(extra charge):
LAN
E
302
B
12
71
Dimensions of
constant climate chambers HPP
(see table below)
Temperature Electronic microprocessor temperature controller with Pt100 and auto-diagnostic system c
Active microprocessor control for humidifying and dehumidifying (10 – 90 % rh), incl. digital indication and auto-diagnostic
system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation; c
humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam
Monitor Microprocessor temperature monitor acting as overtemperature protection,
c
with Pt100 incorporating fault diagnostics with visual and acoustic alarm
Digital over- and undertemperature monitor (protection class 3.3) c
Acoustic alarm:
c
Over- and undertemperature; over-/underhumidity; empty water tank
Timer Real-time/weekly programmer with group function (e.g. Monday-Friday),
c
functions programme operation with up to 40 ramps for temperature and humidity (MEMoryCard XL)
Documentation Internal log memory 1024 kB as ring memory for all setpoints and actual values of temperature and humidity,
c
errors, settings with real-time and date; capacity approx. 3 months at 1 min. intervals
Parallel printer interface for printing logging files,
c
suitable for all PCL3-compatible ink jet printers (USB available via converter, see accessories)
„Celsius“1) software for control and documentation of temperature and relative humidity c
Vacuum ovens
Pe l t i e r- c o o l e d i n c u b a t o r s
C o m p r e s s o r- c o o l e d i n c u b a t o r s
Cooled incubators
CO 2 incubators
www.ad-room.de
Humidity chambers