Professional Documents
Culture Documents
2012 RSC Book-Chapter-1
2012 RSC Book-Chapter-1
net/publication/235942019
CITATIONS READS
0 426
3 authors:
Jerzy Leszczynski
Jackson State University
955 PUBLICATIONS 21,118 CITATIONS
SEE PROFILE
Some of the authors of this publication are also working on these related projects:
The construction of physically adapted basis sets for the calculations of electric and magnetic properties of organic compounds View project
All content following this page was uploaded by Tandabany C. Dinadayalane on 22 May 2014.
CHAPTER 1
a
Interdisciplinary Center for Nanotoxicity, Department of Chemistry and
Biochemistry, Jackson State University, 1400 J.R. Lynch Street, Jackson,
Mississippi 39217, USA; b Department of Civil and Environmental
Engineering, Jackson State University, 1400 J.R. Lynch Street, Jackson,
Mississippi 39217, USA
*E-mail: jerzy@icnanotox.org
1.1 Introduction
Among numerous commercial endeavors, nanotechnology is regarded as the key
technology of the 21st century. It provides novel products and facilitates
applications of innovative techniques in medicine, pharmacy, computer technol-
ogy, and sensing. Therefore, it holds promise for potential global socio-economic
benefits. In 2011, there were about 1100 commercial products that include
nanomaterials. It is a common belief that nanotechnology could assist in solving
many global problems that society faces. These include environmental and health
concerns of the fast-growing human population, as well as access to clean water
and affordable energy. The quickly growing applications of nanomaterials are due
to their unique properties which offer advantages over conventional materials.
The variety of various nanomaterials is too big to cover in a single chapter.
Therefore, we decided to focus on one particular class of species and discuss in
1
View Online
2 Chapter 1
details its characteristics and applications. Since the 2010 Nobel awards
validate the importance of graphene not only in basic research but also in
various commercial applications, we selected this nanomaterial as the main
subject of our chapter.
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
both in quality and quantity, has stimulated the worldwide pursuit of carbon
nanotubes for technological applications. Nevertheless, carbon nanotubes
(especially single-walled carbon nanotubes (SWCNTs)) are still quite
expensive.8 To assist experimental studies, the structures, reactivities, and
functionalization of defect-free and Stone–Wales defective SWCNTs have
been investigated by our group, using quantum chemical calculations.9–16
The morphology of graphene is different from that of CNTs; for example,
the length of CNTs influences their toxicity but graphene and graphene oxide
(GO) do not have a ‘‘length’’.17 An important similarity between these carbon
nanomaterials is that both graphene/graphene oxide and carbon nanotube
structures vary according to the synthetic processes employed. Such processes
can also change their physical properties, including dispersity, surface
functionality, and their toxicity.18 In the materials science world, carbon
nanostructures such as fullerenes, carbon nanotubes and graphene are famous
for their small dimension and unique architecture, and several possible
applications in diversified areas. In addition to these carbon nanostructures,
scientists now produce a plethora of carbon-based nanoforms such as
‘bamboo’ tubes, ‘herringbone’ and ‘bell’ structures.19 Figure 1.1 shows a
‘‘family tree’’ of carbon nanoforms that were obtained by applying various
transformations to graphene (details of operations are provided in the figure).
Though the diagram is non-exhaustive (primarily for clarity), this chart is
useful to classify the nanoforms by morphology and provides a first step
towards a standardized nomenclature.
The research involving graphene has grown at a spectacular pace in the last
few years. Several potential applications have been proposed for graphene.
These include conductive and high-strength composites, energy storage and
energy conversion devices, sensors, field emission displays and radiation
sources, hydrogen storage media, and nanometre-sized semiconductor devices,
probes, and interconnect (Scheme 1.1). Impressive advances have been made in
View Online
Graphene: Properties, Biomedical Applications and Toxicity 3
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
Downloaded on 03 October 2012
Figure 1.1 ‘‘Family tree’’ of primary carbon nanoforms showing the topological
relationships between them. Forms which have not been identified
experimentally are faded. (Reproduced from ref. 19. Copyright 2011,
with permission from Elsevier Ltd.)
high contrast ratio. Thus, LCDs might be the first realistic commercial
application of graphene.21 Like carbon nanotubes, the unique properties of
graphene offer a wide range of opportunities and application potential for
biology and medicine (Scheme 1.1). Bioapplications of carbon nanotubes and
graphene have attracted much attention recently.22–28
Significant recent development and progress in the use of graphene-based
materials for biosensors, drug and other delivery systems, and bioimaging have
generated much excitement in the research community.22–28 In the last few
years, considerable attention has been paid to the health risks of carbon
nanomaterials due to rising global production and the wide range of proposed
applications.29–31
The lungs and skin are regarded as the two main potential exposure sites
Downloaded on 03 October 2012
during the manufacture and handling of carbon nanotubes.32,33 The high ratio
between the length and diameter of carbon nanotubes and their low solubility
in aqueous media make them potentially biopersistent and may lead to toxic
effects similar to those seen with asbestos. Carbon nanotubes might induce
lung cancer and mesothelioma in a similar manner to that of asbestos.34,35
Hence, an understanding of the occupational health, public safety and
environmental implications of carbon nanomaterials is required. Some recent
studies have reported the in vivo biodistribution and toxicity of carbon
nanotubes and graphene. In this chapter, we briefly present various aspects
related to the toxicity of graphene-based nanomaterials.
properties.36,37 Just a few years later, in 2010, Andre Geim and Konstantin
Novoselov were awarded the Nobel Prize for their groundbreaking experi-
mental isolation of single-layer graphene. The experimental realization of
graphene generated vast interest in the areas of fundamental physics, materials
science and engineering. Researchers have been looking for possible applications
of graphene in high-speed and radio-frequency logic devices, thermally and
electrically conductive reinforced composites, sensors, transparent electrodes for
displays and solar cells, and biomedicine.21–27,36–43 Numerous graphene-based
biosensing devices and techniques based on various mechanisms have been
developed in the past few years.22,23 Graphene is obviously a prospective
material for nanoelectronics. The electron transport in graphene was described
by a Dirac-like equation.38,39 The studies pertinent to the chemistry of graphene
sheets have also been reported.40–45 The growth and isolation of graphene have
been recently reviewed.2,3,44,45 Research in the area of graphene material has
been rapidly growing due to the recent advances in technology for the growth,
isolation and characterization of two-dimensional carbon sheets.
Graphene sheets need not always be perfect. Various defects such as Stone–
Wales (SW), vacancies, and pore defects can occur in the graphene sheet. Like the
creation of vacancies by knocking atoms out of the graphene sheet, surplus atoms
can be found as ad-atoms on the graphene surface. An ad-dimer or inverse
Stone–Wales (ISW) defect is characterized by two adjacent five-membered rings
instead of two adjacent seven-membered rings in a Stone–Wales defect.
Experimental observations of defects in graphene were reported.46,47
View Online
6 Chapter 1
Figure 1.2 The segment of graphene containing different defects: (a) Stone–Wales
(SW), (b) inverse Stone–Wales (ISW) defect, (c) all-hydrogen saturated
pore in graphene, (d) HRTEM image of graphene with Stone–Wales
defect, (e) image of vacancy defect, (f) defect image with four pentagons
(green) and four heptagons (red). In (d)–(f), the atomic configuration was
superimposed for easy recognition. (Adapted with permission from ref.
46 and 47. Copyright 2008 and 2009 American Chemical Society.)
View Online
Graphene: Properties, Biomedical Applications and Toxicity 7
21
indicate that the Stone–Wales defective graphene sheet is 83.3 kcal mol less
stable than the defect-free graphene sheet (Scheme 1.3). Figure 1.2 depicts
some of the common defects and HRTEM images of defects in a graphene
sheet. The characteristics of typical defects and their concentrations in
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
pH. Compared to single-walled carbon nanotubes for drug loading via p–p
stacking, NGO is advantageous in terms of its low cost and ready scalability.51
Yang et al. have studied the in vivo behaviors of nanographene sheets (NGS)
with polyethylene glycol (PEG) coating by a fluorescent labeling method.48
They have labeled NGS-PEG with Cy7, which is a commonly used near-
infrared fluorescent dye, in order to study the in vivo behaviors of NGS.48
Interestingly, the majority of Cy7 dye was covalently conjugated to NGS-PEG
via the formation of an amide bond instead of p-stacking physisorption.
BALB/c mice bearing 4T1 murine breast cancer tumors, nude mice bearing KB
human epidermoid carcinoma tumors, and U87MG human glioblastoma
tumors were intravenously injected with NGS-PEG–Cy7. Yang et al. have
observed a prominent uptake of NGS in the tumor with relatively low quantity
in other parts of the mouse body after 24 h post-injection for all three types of
tumor models.48
The graphical and pictorial illustrations of in vivo photothermal therapy
study using intravenously injected NGS-PEG are given in Figure 1.4. Tumor
growth curves of different groups after treatment were given. The tumor
volumes were normalized to their initial sizes. There were six mice in the
untreated group, ten mice in the ‘laser only’ group, seven mice in the ‘NGS-
View Online
Graphene: Properties, Biomedical Applications and Toxicity 9
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
Downloaded on 03 October 2012
Figure 1.4 In vivo photothermal therapy study using intravenously injected NGS-
PEG. (a) Tumor growth curves of different groups after treatment. (b)
Survival curves of mice bearing the 4T1 tumor after various treatments
indicated. NGS-PEG-injected mice after photothermal therapy survived
over 40 days without any single death. (c) Representative photos of
tumors on mice after various treatments indicated. (d) Semiquantitative
biodistribution of NGS-PEG–Cy7 in mice determined by the averaged
fluorescence intensity of each organ (after subtraction by the fluorescence
intensity of each organ before injection). Error bars in (a) were based on
standard deviations and in (d) were based on three mice per group.
(Adapted with permission from ref. 48. Copyright 2010 American
Chemical Society.)
View Online
10 Chapter 1
PEG only’, and ten mice in the ‘NGS-PEG + laser’ groups. While injection of
NGS-PEG by itself or laser irradiation on uninjected mice did not affect tumor
growth, tumors in the treated group were completely eliminated after NGS-
PEG injection and followed by near-infrared (NIR) laser irradiation.
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
caused appreciable thyroid uptake only at the earliest time points. Very low
thyroid uptake was observed at later time points and was barely detectable on
and after day 3.
Liu et al. have reported a green and facile method for the preparation of
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
As shown in Figure 1.6, the drug loading ratio (the weight ratio of drug
loaded to FA–NGO) for DOX was remarkably higher than that of CPT (more
than 400% for DOX, and only about 4.5% for CPT). More importantly, the
loading ratio was linearly correlated to the concentration of drugs
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
(Figure 1.6c), thus showing controlled loading of DOX or CPT onto the
NGO sheets. Owing to the difference in the chemical structures of the two
drugs, the difference in the p–p stacking and hydrophobic interactions with the
NGO occurred. Hence, the two drugs exhibited different loading ability. The
loading ratio of DOX or CPT was influenced by the distribution coefficient of
the drug dissolved in solution and that adsorbed on the graphene carriers.
Zhang et al. have reported that about 35% of DOX and approximately 17% of
CPT loaded on FA–NGO were released after 48 h at pH 5.0, while much less
DOX or CPT was released after 48 h at pH 7.0 (Figure 1.6d).26
Downloaded on 03 October 2012
Figure 1.6 (a) Plot of loading ratio of DOX to FA–NGO versus the concentration of
DOX; (b) plot of loading ratio of CPT to FA–NGO versus the
concentration of CPT; (c) plot of loading ratio of DOX to FA–NGO
versus concentration of DOX in a mixture of DOX and CPT
(concentration of CPT 100 mg mL21); and (d) plot of the release of
DOX and CPT from FA–NGO at pH 5 and pH 7. (Reproduced with
permission from ref. 26. Copyright 2010 Wiley-VCH Verlag GmbH &
Co. KGaA, Weinheim.)
View Online
Graphene: Properties, Biomedical Applications and Toxicity 13
Gene therapy is used to cure diseases that are difficult for traditional clinical
methods. The major obstacle in this area is to develop non-viral-based safe and
efficient gene delivery vehicles. Over the years, scientists have utilized cationic
polymers and various nanomaterials such as carbon nanotubes, silica
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
toxicity of nanomaterials has been the key issue that should be carefully
investigated before the full implementation of such nanomaterials in a wide
range of biological applications. Information on the potential health effects of
nanomaterials is urgently required and should be updated regularly because of
the growing industrial use of such species. Owing to the distinct and unique
physicochemical properties of many nanomaterials, their possible toxicity may
differ from that of the bulk material of similar chemical nature. CNTs and
graphite nanofibres agglomerate and remain insoluble on inhalation exposure
to the lungs. The cytotoxic effects of graphene are expected to be significantly
different when compared to those of carbon nanotubes.
Norppa and co-workers have reported that treatment of the BEAS 2B cells
with graphite nanofibres decreased cell viability in a dose-dependent manner
Downloaded on 03 October 2012
after all the exposure times used (24, 48, and 72 h) when the cells were allowed
to recover for 48 h post treatment (Figure 1.7). Also, both CNTs and graphite
nanofibres showed similar toxicity. They were found to be genotoxic in human
bronchial epithelial BEAS 2B cells. A dose-dependent increase in DNA
Figure 1.7 Cell viability (number of living cells) in cultured human bronchial
epithelial BEAS 2B cells after 24 h, 48 h, and 72 h exposure to graphite
nanofibres. The cell viability was evaluated with the Trypan blue dye
exclusion assay. The symbols show mean numbers of living cells in
triplicate cultures. (Reproduced from ref. 59. Copyright 2008, with
permission from Elsevier Ireland Ltd.)
View Online
Graphene: Properties, Biomedical Applications and Toxicity 15
damage was reported and the damage effect was more significant at longer
treatment times. It should also be taken into consideration that the transition
metals used as catalysts in the manufacture of carbon nanomaterials may
contribute to the genotoxicity.59
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
Figure 1.8 Effect of graphene or SWCNT on (A) mitochondrial toxicity and (B)
LDH release (cell membrane damage marker). (C) Morphology change
of PC12 cells: left, control; middle, graphene; right, SWCNT. Bar 5 10
mm. (Reproduced with permission from ref. 60. Copyright 2010
American Chemical Society).
View Online
16 Chapter 1
that the PEGylated nanoscale graphene oxide sheets were not cytotoxic by
themselves (Figure 1.9).50 The relative cell viability (versus untreated control)
data was collected for HCT-116 cells incubated with CPT-11, SN38, and
NGO-PEG–SN38 at different concentrations for 72 h. Free SN38 was
dissolved in DMSO and diluted in phosphate buffer saline (PBS). Water-
soluble NGO-PEG–SN38 showed similar toxicity as SN38 in DMSO and far
higher potency than CPT-11.50
In the in vivo toxicological studies, Yang et al. did not notice any obvious
sign of toxic side effects for NGS-PEG-injected mice at the dose of 20 mg kg21
within 40 as well as 90 days.48,49 Neither death nor significant body weight
drop was noted in the NGS-PEG + laser treated group. Yang et al. reported
that they also did not observe any signal of organ damage from haematoxylin
Downloaded on 03 October 2012
and eosin (H&E) stained organ slices. They have also carried out blood
biochemistry and hematology analysis to understand the toxic effect of NGS-
PEG on the treated mice.49 The blood biochemistry tests were done to the liver
function markers including alanine aminotransferase (ALT), aspartate
aminotransferase (AST), alkaline phosphatase (ALP), and the ratio of albumin
and globulin (A/G). As shown in Figure 1.10a and 1.10b, no obvious hepatic
toxicity was induced by NGS-PEG treatment. The urea levels in the blood of
treated mice were also normal indicating normal kidney functions.
Biochemistry tests of important hematology markers of white blood cells,
red blood cells, hemoglobin, mean corpuscular volume, mean corpuscular
hemoglobin, mean corpuscular hemoglobin concentration, and platelet count
in the NGS-PEG-treated groups at different times post-injection were reported
to be normal compared with the control groups and in good agreement with
the reference normal ranges.
Figure 1.9 In vitro cell toxicity assay. (a) Relative cell viability (versus untreated
control) data of HCT-116 cells incubated with CPT-11, SN38, and NGO-
PEG–SN38 at different concentrations for 72 h. (b) Relative cell viability
data of HCT-116 cells after incubation with NGO-PEG with (red) and
without (black) SN38 loading. Plain NGO-PEG exhibited no obvious
toxicity even at very high concentrations. Error bars were based on triplet
samples. (Reproduced with permission from ref. 50. Copyright 2008
American Chemical Society).
View Online
Graphene: Properties, Biomedical Applications and Toxicity 17
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
Downloaded on 03 October 2012
Figure 1.10 Blood biochemistry and hematology data of female BALB/c mice
treated with NGS-PEG at the dose of 20 mg kg21 at 3, 7, 20, 40, and 90
days post-injection. Age-matched control untreated mice were sacri-
ficed at 3, 40, and 90 d (3d-CK, 40d-CK, and 90d-CK). (a) ALT, ALP,
and AST levels in the blood at various time points after NGS-PEG
treatment. (b) Time-course albumin/globulin ratios. Blood chemistry
data suggested no hepatic disorder induced by NGS-PEG treatment. (c)
Blood urea nitrogen (BUN) over time. (d)–(k) Time-course changes of
white blood cells (d), red blood cells (e), hemoglobin (f), mean
corpuscular volume (g), mean corpuscular hemoglobin (h), mean
corpuscular hemoglobin concentration (i), platelets (j), and hematocrit
(k) from control mice and NGS-PEG-treated mice. All blood chemistry
and hematological data were all within the normal range. Statistics were
based on five mice per data point. Gray areas in the figures show the
normal reference ranges of hematology data of female BALB/c mice.
(Reproduced with permission from ref. 49. Copyright 2011 American
Chemical Society.)
They reported that PEI at a low molecular weight (1.2 kDa) was much less
toxic but with a high molecular weight (at 10 kDa) appeared to be rather toxic
to HeLa cells, with the half maximal inhibitory concentration (IC50) value of
approximately 30 mg L21.53 They observed significantly reduced toxicity for
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
the GO-PEI-10k complex, whose in vitro toxicity was reported to be one order
of magnitude less than that of PEI-10k. Even at a GO-PEI-10k concentration
as high as 300 mg L21, the relative cell viability was still higher than 80%. The
decreased cytotoxicities of GO-PEI complexes were attributed to the rigid
molecular structure that reduced the density of cationic residues interacting
with cells. Feng et al. mentioned that GO-PEI complexes exhibited slightly
higher relative cell viabilities compared to GO at high concentrations, likely
owing to the improved stability of GO-PEI in physiological environments.
With respect to PEI-10k, although it did offer efficient EGFP transfection at
nitrogen/phosphate (N/P) ratios of 20 and 40, obvious toxicity to cells was
noted at the N/P ratio of 80. In contrast, high EGFP expression together with
no obvious cell toxicity was observed when using GO-PEI-10k as the
Downloaded on 03 October 2012
Figure 1.11 Relative cell viability of MCF-7 (a) 24 and (b) 48 h after treatment with
FA–NGO/DOX, FA–NGO/DOX+FA, NGO-SO 3H/DOX, NGO-
SO3H/DOX+FA, and DOX. The asterisks indicate P , 0.05 versus
normal cells and D indicates P , 0.05 versus FA–NGO/DOX groups at
the same concentration of DOX. (c) Relative cell viability of MCF-7
treated with FA–NGO/CPT and FA–NGO/DOX/CPT. The asterisks
indicate P , 0.05 versus normal cells. For (a)–(c), when the P value was
less than 0.05, differences were considered statistically significant. The P
value, which is associated with the statistical significance testing, is the
probability of obtaining a test statistic at least as extreme as the one that
was actually observed, assuming that the null hypothesis is true.
(Reproduced with permission from ref. 26. Copyright 2010 Wiley-VCH
Verlag GmbH & Co. KGaA, Weinheim.)
View Online
Graphene: Properties, Biomedical Applications and Toxicity 19
that no obvious toxicity was found for FA–NGO even at a concentration of 100
mg mL21.26 Zhang et al. have also compared the cytotoxicity of FA–NGO/CPT/
DOX (weight ratio of CPT:DOX was 1:0.976) with that of FA–NGO/CPT and
FA–NGO/DOX. They found that the FA–NGO/DOX with a concentration of
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
not exhibit toxicity to human fibroblast cells (HDF). However, the dose .50
mg mL21 exhibited obvious cytotoxicity such as decreasing cell adhesion,
inducing cell apoptosis, entering into lysosomes, mitochondrion, endoplasm,
and cell nucleus. Similar phenomena were also observed in other cell lines such
as human gastric cancer MGC803, human breast cancer MCF-7, MDA-MB-
435, and liver cancer HepG2 cell lines indicating obvious toxicity of GO to
human normal cells or tumor cells. Furthermore, the amount of GO inside
HDF cells increased with increasing culture time; a lot of graphene oxides
appeared as black dots scattered in the cell cytoplasm around the cell nucleus,
a few graphene oxides were located inside the nucleus. As the cell culture time
increased, the survival rate of cells decreased, which is highly dependent on the
dose of graphene oxides (Figure 1.13a). Western blot results showed that the
expression levels of laminin, fibronectin, focal adhesion kinase (FAK), and cell
cycle protein cyclin-D3 in the HDF cells treated with GO were considerably
decreased compared with normal cells (Figure 1.13b). As shown in
Figure 1.13c, the cell adhesive ability decreased markedly with the increase
in GO concentration and culture time.66 Graphene oxide and reduced
graphene oxide have been reported to exhibit toxicity to mice fibroblast cells
(line L929). Furthermore, the type of dispersant used to stabilize the
suspension, the type of nanomaterials, and their concentrations significantly
influence the cell cytotoxicity. Both graphene oxide and reduced graphene
oxide exhibited good cytocompatibility with concentrations between 3.125 mg
mL21 and 12.5 mg mL21.67
View Online
Graphene: Properties, Biomedical Applications and Toxicity 21
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
Figure 1.13 (a) Effects of GO on human fibroblast cells: the HDF survival rate at
different concentrations of GO and different culture time. (b) Western
blot analysis of adhesion proteins in HDF cells cultured with different
concentrations of GO for 5 days. Lanes 1–6 show the expression levels
of proteins in HDF cells treated with GO with the following
concentrations: 100, 50, 20, 10, 5, 0 mg mL21, respectively. (c) GO-
treated HDF cell adhesion ability measured by the centrifugation
method. The percentage of adhesive cells decreased with the increase in
GO concentration and culture time. (Reproduced with permission from
ref. 66. Copyright 2010 Wang et al.).
Downloaded on 03 October 2012
In the case of mice, GO under low dose (0.1 mg) and middle dose (0.25 mg) did
not exhibit obvious toxicity but under high dose (0.4 mg) exhibited chronic
toxicity and lung granuloma formation, mainly located in the lung, liver, spleen,
and kidney. GO could produce cytotoxicity in a dose- and time-dependent
manner. Wang et al. suggested that exposures to GO may induce severe
cytotoxicity and lung diseases. They have proposed possible mechanisms of
effects of GO on human cells and mice. Graphene oxide has not been suggested
as a good biocompatible material for human because of the long-term stay of
GO in the kidney. Also, it is a very difficult species to be cleaned by the kidney.66
Chang et al. performed a comprehensive study on the toxicity of GO by
examining the influences of GO on the morphology, viability, mortality and
membrane integrity of A549 cells that are human lung carcinoma epithelial
cells.68 They also indicated that GO has pretty good biocompatibility to A549
cells compared to fullerene, CNT, and carbon nanofibres. GO was not found
to be cytotoxic to A549 cells since it hardly entered cells. However, GO can
cause a dose-dependent oxidative stress in cell and induce a slight loss of cell
viability at high concentration. The possible mechanism for the toxicity of GO
to A549 cells was proposed. Similar to the case of CNTs, GO absorbs the
nutrients in culture medium and then the depletion of nutrients induces the
oxidative stress and toxicity to A549 cells. Oxidative stress is a well-recognized
toxicological mechanism of various nanoparticles. The oxidative stress induced
by GO is considerably lower compared to fullerene and CNTs.68
We have noticed the inconsistency in the toxicity data of GO and such
inconsistency might come from the GO synthesis/film preparation, and the
testing models. Until now, the detailed information on the effect of shape of
nanoparticles on the toxicity is still unknown. However, the few available results
indicate that the shape affects the biological fate of nanomaterials.69,70 Yuan
et al. have performed a comparative study of protein profile of human hepatoma
View Online
22 Chapter 1
sheets are more damaging to mammalian fibroblasts than the less densely
packed graphene oxide.17 Dash and co-workers have studied the effects of
graphene oxide and reduced graphene oxide on ultrastructural details of
platelets. They have analyzed the interaction between graphene oxide and
blood platelets, the cells responsible for acute arterial thrombotic events like
ischemic heart disease and stroke. They have showed that graphene oxide can
evoke strong aggregatory response in platelets in a scale comparable to that
elicited by thrombin, one of the most potent physiological agonists of platelets.
However, reduced graphene oxide was considerably less effective in activating
platelets due to the reduced charge density on the graphene surface.72
Liu et al. have used 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium
bromide for MTT assay to determine the cellular viabilities of DOX@gelatin-
GNS with the MCF-7 cells.52 Gelatin–GNS, even at a high concentration (200 mg
mL21), was not found to be cytotoxic against MCF-7 cells. In general, the smaller
size sheets are expected to be used in the drug delivery process and they showed
very low cytotoxicity against MCF-7 cells. The cytotoxicity of the DOX@gelatin-
GNS and free DOX enhanced gradually with increasing time. Furthermore, the
DOX@gelatin-GNS exhibited a lower cytotoxicity than free DOX at the same
dose. The gelatin-mediated sustained release effect of the drug, which may have
potential clinical advantages pertaining to increased therapeutic efficacy, was
proposed to be useful for cancer therapy in clinical applications because it could
control the release rate of the drug in body. Therefore, the blood drug
concentration could be maintained at a stable level for a long time.52
Both graphene and graphene oxide suspensions were proposed to inhibit the
growth of Escherichia coli bacteria but with a minimal cytotoxicity.73 The
nanowalls were reported to be toxic to the bacteria. Akhavan and Ghaderi have
studied the toxicity of graphene sheets, particularly the direct interaction of its
extremely sharp edges with bacteria, the RNA effluxes through the damaged cell
membranes of both Gram-negative E. coli and Gram-positive Staphylococcus
View Online
Graphene: Properties, Biomedical Applications and Toxicity 23
aureus bacteria. Graphene oxide and reduced graphene oxide nanowalls were
used to test the bacterial toxicity. The direct contact interaction of the bacteria
with the very sharp edge of the nanowalls resulted in more damage to the cell
membrane of the Gram-positive S. aureus bacteria, which lacks the outer
Published on 30 September 2012 on http://pubs.rsc.org | doi:10.1039/9781849735476-00001
1.3 Conclusions
In this chapter, we have reviewed the recent biomedical applications of graphene
and the biocompatible systems derived from it. The key defects in graphene are
highlighted. Nanoscale graphene and graphene oxide have immense potential in
nanomedicine as biocompatible and supportive substrates, and as a novel tool for
the delivery of therapeutic molecules. Graphene can be successfully used as a
non-toxic nano-vehicle for efficient gene transfection, a novel gene delivery nano-
Downloaded on 03 October 2012
vector with low cytotoxicity and high transfection efficiency, which is promising
for future applications in non-viral-based gene therapy. Like carbon nanotubes,
there are concerns about toxicity in the use of graphene. A limited number of
publications have appeared on this topic. The preliminary experimental results
highlighted the toxicology of graphene materials and difficulties in evaluating it.
Similar to CNTs, graphitic fibers were found to be genotoxic in human bronchial
epithelial BEAS 2B cells; dose-dependent DNA damage was reported with
increasing effect of the damage at long treatment times. Experimental studies
have demonstrated that the shape of carbonaceous nanomaterials plays an
extremely important role in how they interact with cells and potentially other
biological systems, such as tissues and organisms. The toxicity of graphene and
graphene oxide depends on the exposure environment and mode of interaction
with cells. The investigations of biomedical applications of graphene structures
with different defects and their toxicity should be rewarded.
Acknowledgments
We thank the Department of Defense (DoD) for the HPCDNM project
(Contract # W912HZ-09-C-0108) through the U.S. Army/Engineer Research
and Development Center (Vicksburg, MS) and the National Science
Foundation (NSF/CREST HRD-0833178) for the NSF-CREST center
(Interdisciplinary Center for Nanotoxicity).
References
1. T. C. Dinadayalane and J. Leszczynski, Struct. Chem., 2010, 21, 1155.
2. A. K. Geim, Science, 2009, 324, 1530.
3. M. J. Allen, V. C. Tung and R. B. Kaner, Chem. Rev., 2010, 110, 132.
View Online
24 Chapter 1
63. E. C. Salas, Z. Sun, A. Lüttge and J. M. Tour, ACS Nano, 2010, 4, 4852.
64. G. M. Mutlu, G. R. S. Budinger, A. A. Green, D. Urich, S. Soberanes, S.
E. Chiarella, G. F. Alheid, D. R. McCrimmon, I. Szleifer and M. C.
Hersam, Nano Lett., 2010, 10, 1664.
65. A. A. Shvedova, E. R. Kisin, R. Mercer, A. R. Murray, V. J. Johnson, A.
I. Potapovich, Y. Y. Tyurina, O. Gorelik, S. Arepalli, D. Schwegler-Berry,
A. F. Hubbs, J. Antonini, D. E. Evans, B.-K. Ku, D. Ramsey, A.
Maynard, V. E. Kagan, V. Castranova and P. Baron, Am. J. Physiol.:
Lung Cell. Mol. Physiol., 2005, 289, L698.
66. K. Wang, J. Ruan, H. Song, J. Zhang, Y. Wo, S. Guo and D. Cui,
Nanoscale Res. Lett., 2011, 6, 8.
67. M. Wojtoniszak, X. Chen, R. J. Kalenczuk, A. Wajda, J. Òapczuk, M.
Kurzewski, M. Drozdzik, P. K. Chu and E. Borowiak-Palen, Colloids
Surf., B, 2012, 89, 79.
68. Y. Chang, S.-T. Yang, J.-H. Liu, E. Dong, Y. Wang, A. Cao, Y. Liu and
H. Wang, Toxicol. Lett., 2011, 200, 201.
69. W. K. Oh, S. Kim, H. Yoon and J. Jang, Small, 2010, 6, 872.
70. A. Simon-Deckers, S. Loo, M. Mayne-L’hermite, N. Herlin-Boime, N.
Menguy, C. Reynaud, B. Gouget and M. Carrière, Environ. Sci. Technol.,
2009, 43, 8423.
71. J. Yuan, H. Gao and C. B. Ching, Toxicol. Lett., 2011, 207, 213.
72. S. K. Singh, M. J. Singh, M. K. Nayak, S. Kumari, S. Shrivastava, J. J. A.
Gracio and D. Dash, ACS Nano, 2011, 5, 4987.
73. W. Hu, C. Peng, W. Luo, M. Lv, X. Li, D. Li, Q. Huang and C. Fan, ACS
Nano, 2010, 4, 4317.
74. O. Akhavan and E. Ghaderi, ACS Nano, 2010, 4, 5731.
75. S. Kang, M. Herzberg, D. F. Rodrigues and M. Elimelech, Langmuir,
2008, 24, 6409.