Professional Documents
Culture Documents
En g6k
En g6k
■Application Examples
• Telecommunication equipment
• Office automation machines
• Test and measurement equipment
• Building automation equipment
• Security equipment
• Industrial equipment
• Amusement equipment
• Home appliances
1
G6K Surface Mounting Relay
■Ordering Information
●Surface Mounting Terminal Standard Models
Packing Tube Packing Tape Packing
Enclosure Relay Rated coil Minimum Rated coil Minimum Minimum ordering unit
Contact form Model Model
rating Function voltage packing unit voltage packing unit (tape packing)
3 VDC 3 VDC
4.5 VDC 4.5 VDC
G6K-2F 5 VDC G6K-2F-TR 5 VDC
12 VDC 12 VDC
24 VDC 24 VDC
3 VDC 3 VDC
Highly insulated 4.5 VDC Highly insulated 4.5 VDC
G6K-2F-Y 5 VDC G6K-2F-Y-TR 5 VDC
12 VDC 12 VDC
Single-side 24 VDC 24 VDC
stable 3 VDC 3 VDC
4.5 VDC 4.5 VDC
G6K-2G 5 VDC G6K-2G-TR 5 VDC
12 VDC 12 VDC
24 VDC 24 VDC
Fully sealed DPDT (2c) 50 pcs/tube 900 pcs/reel 1,800 pcs/2 reels
3 VDC 3 VDC
Highly insulated 4.5 VDC Highly insulated 4.5 VDC
G6K-2G-Y 5 VDC G6K-2G-Y-TR 5 VDC
12 VDC 12 VDC
24 VDC 24 VDC
G 3 VDC 3 VDC
6 Highly insulated 4.5 VDC Highly insulated 4.5 VDC
K G6KU-2F-Y 5 VDC G6KU-2F-Y-TR 5 VDC
12 VDC 12 VDC
Single-
24 VDC 24 VDC
winding
3 VDC 3 VDC
latching
Highly insulated 4.5 VDC Highly insulated 4.5 VDC
G6KU-2G-Y 5 VDC G6KU-2G-Y-TR 5 VDC
12 VDC 12 VDC
24 VDC 24 VDC
2
G6K Surface Mounting Relay
■Ratings
Coil: Single-side Stable Models Contacts
Item Rated Coil Must operate Must release Max. voltage Power Item Load Resistive load
current resistance voltage (V) voltage (V) (V) consumption Contact type Bifurcated crossbar
Rated voltage (mA) (Ω) % of rated voltage (mW)
Contact material Ag (Au-Alloy contact)
3 VDC 33.0 91
0.3 A at 125 VAC,
4.5 VDC 23.2 194 Rated load
1 A at 30 VDC
Approx.
5 VDC 21.1 237 80% max. 10% min. 150% Rated carry current 2A
100
12 VDC 9.1 1,315 Max. switching voltage 125 VAC, 60 VDC
24 VDC 4.6 5,220 Max. switching current 1A
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
■Characteristics
Relay Function Single-side stable models Single-winding latching models
Item G6K-2F, G6K-2G, G6K-2PG6K-2F-Y, G6K-2G-Y, G6K-2P-YG6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
Contact resistance *1 100 mΩ max.
Operating (set) time 3 ms max.
Release (reset) time 3 ms max.
Minimum set/reset signal width − 10 ms
Insulation resistance *2 1,000 MΩ min. (at 500 VDC)
Between coil and
1,500 VAC, 50/60 Hz for 1 min
contacts
Dielectric Between contacts of
1,000 VAC, 50/60 Hz for 1 min
strength different polarity
Between contacts of
750 VAC, 50/60 Hz for 1 min
the same polarity
Between coil and
1,500 V (10 × 160 μs) 2,500 V (2 × 10 μs), 1,500 V (10 × 160 μs)
contacts
Impulse
Between contacts of
withstand
different polarity
voltage 1,500 V (10 × 160 μs)
Between contacts of
the same polarity
Vibration Destruction 10-55-10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2
resistance Malfunction 10-55-10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2
Shock Destruction 1,000 m/s2
resistance Malfunction 750 m/s2
Mechanical 50,000,000 operations min. (at 36,000 operations/hour)
Durability
Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) *3 10 μA at 10 mVDC
Ambient operating temperature -40 to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 0.7 g
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 *3. This value was measured at a switching frequency of 120
VDC with a voltage-drop method. operations/min and the criterion of contact resistance is
*2. The insulation resistance was measured with a 500 VDC 50 Ω. This value may vary depending on the switching
megohmmeter applied to the same parts as those used for frequency and operating environment. Always
checking the dielectric strength. double-check relay suitability under actual operating
conditions.
3
G6K Surface Mounting Relay
■Engineering Data
●Maximum Switching Capacity ●Durability ●Ambient Temperature vs.
Maximum Coil Voltage
Switching current (A)
0.1 1 0
10 30 50 70 100 300 500 700 1,000 0 0.2 0.4 0.6 0.8 1 1.2 −40 −20 0 20 40 60 80 100
Switching current (A) Ambient temperature (°C)
Switching voltage (V)
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
●Ambient Temperature vs. Carry ●Ambient Temperature vs. Must ●Ambient Temperature vs. Must
Current Operate or Must Release Voltage Set or Must Reset Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y G6KU-2G (F/P)-Y
Carry current (A)
2.4 100
On the basis of rated voltage (%)
90
2.0 90
max. Max. estimated value
80
−
X
G 1.6 70 min. 80
6 60
K 70
max.
1.2 50
−
60 X
40
0.8 min.
30 max.
− 50
X
20 min.
0.4
40
10 Must operate voltage
Must release voltage
0 0 30
-40 -20 0 20 40 60 80 100 −60 −40 −20 0 20 40 60 80 100 −60 −40 −20 0 20 40 60 80 100
Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C)
1,000
1,000 Sample: G6K-2G Sample: G6K-2G
Energized NO contact
Number of Relays: 10 pcs Number of Relays: 10 pcs
Test conditions: 1 A resistive load at 30 VDC NC contact
800 500 Test conditions: 1 A resistive load
with an operation rate of 50% at 30 VDC with an operation rate
80
X 600 De- Z Switching frequency: 1,800 operations/h of 50%
1,000 energized 1,000 max. 300 Switching frequency: 1,800
400
operations/h
200 60 min.
Must operate voltage
100
200 Contact resistance max.
40 max.
400
1,000 1,000 50 min.
Z' 600 X' min.
Sample: G6K-2G
+30
Change rate on the
basis of initial value (%)
+30
Change rate on the
basis of initial value (%)
50
max. +20 +20
max.
min. +10 +10
min. Sample Sample
30 0 0
−10 −10
Energized −20 −20
−30
Average value Energized Average value
10 −30
0.001 0.01 0.1 1 10 100 1,000 10,000 100,000 Must operate voltage Must operate voltage
Operating frequency (x103 operations) Must release voltage Must release voltage
4
G6K Surface Mounting Relay
0 0 0
V.SWR
0 0 0
Isolation (dB)
1.4 G
40 0.2 30 1.25
Return loss
50 40 1.2
60 0.3
50 1.15
70
60 1.1
80 0.4
90 70 1.05
Sample: G6K-2G V.SWR
Number of Relays: 10 pcs
100 0.5 80 1
1 10 100 1 10 100 1 10 100
Frequency (MHz) Frequency (MHz) Frequency (MHz)
●Must Operate and Must Release ●Must Operate and Must Release ●Vibration Resistance
Time Distribution *1 Bounce Time Distribution *1 G6K-2G (F/P), G6K-2G (F/P)-Y
G6K-2G (F/P), G6K-2G (F/P)-Y G6K-2G (F/P) , G6K-2G (F/P)-Y
Number of contacts
Number of contacts
60 60 10.0
Change rate on the basis of rated value (%)
5.0
40 40
0.0
Must release voltage
20 20
−5.0
Sample: G6K-2G
Number of Relays: 50 pcs
−10.0
0 0.5 1 1.5 2 2.5 3 0 0.5 1 1.5 2 2.5 3 Initial After test
Time (ms) Time (ms)
5
G6K Surface Mounting Relay
Orientation mark
5 2.54
1 2 3 4
0.5
3.5
5.08
0.4±0.1 R0.2
1.19 (2.54) (2.54) 0.15
2.54 5.08
5.08 8 7 6 5
7.62 (0.71)
Note: Check carefully the coil
(1.19) 7.62 polarity of the Relay.
Note: Each value has a tolerance of ±0.3 mm.
6
G6K Surface Mounting Relay
7
G6K Surface Mounting Relay
on one tube.
Be sure not to make mistakes in Relay orientation when
mounting the Relay to the PCB. 80 330
Stopper Orientation of Relays Stopper
(gray) (green)
R1
Pulling 7.5±0.1
direction
16±0.1
10.6 10.6±0.1
PCB pattern.
• In order to perform correct soldering, it is recommended that
Soldering
the correct soldering conditions be maintained as shown
220 to 245
below on the left side.
180 to 200 Correct Soldering Incorrect Soldering
Relay
Preheating Terminal
150
Land
Heel fillet
PCB
is formed
90 to 120 20 to 30
Time (s) Solder Insufficient amount Excessive amount
(The temperature profile indicates the temperature on the circuit board.) of solder of solder
(2) IRS Method (Mounting Solder: Lead-free) Visually check that the Relay is properly soldered.
Temperature (°C)
180
Preheating
150
Relay terminal
section
8
G6K Surface Mounting Relay
■Approved Standards
UL recognized: UL1950 (File No. E41515) BSI (EN62368-1) (File No.VC689955)
CSA certified: C22.2 No. 950 (File No. LR31928) Contact form Isolation category Voltage
Number of DPDT (2c) Basic Insulation 125 VAC
Contact
Coil rating Contact rating test
form
operations
2 A, 30 VDC at 40°C
DPDT G6K-2G(F/P): 3 to 24 VDC
0.5 A, 60 VDC at 40°C 6,000
(2c) G6K(U)-2G(F/P)-Y: 3 to 24 VDC
0.3 A, 125 VAC at 40°C
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Long-term Continuously ON Contacts ●Maximum Allowable Voltage
• Using the Relay in a circuit where the Relay will be ON • The maximum allowable voltage of the coil can be obtained
continuously for long periods (without switching) can lead to from the coil temperature increase and the heat-resisting
unstable contacts because the heat generated by the coil itself temperature of coil insulating sheath material. (Exceeding the
will affect the insulation, causing a film to develop on the heat-resisting temperature may result in burning or
contact surfaces. We recommend using a latching relay short-circuiting.) The maximum allowable voltage also involves
(magnetic-holding relay) in this kind of circuit. If a single-side important restrictions which include the following:
stable model must be used in this kind of circuit, we • Must not cause thermal changes in or deterioration of the
recommend using a fail-safe circuit design that provides insulating material. G
protection against contact failure or coil burnout. • Must not cause damage to other control devices. 6
K
• Must not cause any harmful effect on people.
●Relay Handling • Must not cause fire.
• Use the Relay as soon as possible after opening the Therefore, be sure to use the maximum allowable voltage
moistureproof package. (As a guideline, use the Relay within beyond the value specified in the catalog.
one week at 30°C or less and 60% RH or less.) If the Relay is • As a rule, the rated voltage must be applied to the coil. A
left for a long time after opening the moisture-proof package, voltage exceeding the rated value, however, can be applied to
the appearance may suffer and seal failure may occur after the the coil provided that the voltage is less than the maximum
solder mounting process. To store the Relay after opening the allowable voltage. It must be noted that continuous voltage
moisture-proof package, place it into the original package and application to the coil will cause a coil temperature increase
sealed the package with adhesive tape. thus affecting characteristics such as electrical life and
• When washing the product after soldering the Relay to a PCB, resulting in the deterioration of coil insulation.
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the ●Coating
Relay in a cold cleaning bath immediately after soldering. • The Relay mounted on the PCB may be coated or washed but
do not apply silicone coating or detergent containing silicone,
●Claw Securing Force During Automatic Mounting otherwise the silicone coating or detergent may remain on the
• During automatic insertion of Relays, make sure to set the surface of the Relay.
securing force of each claw to the following so that the Relays
characteristics will be maintained. ●PCB Mounting
C • If two or more Relays are closely mounted with the long sides
A B Direction A: 1.96 N max. of the Relays facing each other and soldering is performed
Direction B: 4.90 N max. with infrared radiation, the solder may not be properly exposed
Direction C: 1.96 N max.
to the infrared rays. Be sure to keep the proper distance
between adjacent Relays as shown below.
●Environmental Conditions During Operation, Storage, G6K-2G
and Transportation
• Protect the Relay from direct sunlight and keep the Relay
under normal temperature, humidity, and pressure.
2 mm min.
9
G6K Surface Mounting Relay
G
6
K
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K106-E1-11
0118(0207)(O)
10