Professional Documents
Culture Documents
2.1 Use
This plant is conceived for derivation of hydrogen
from Natural Gas.
The design specifications of the plant as well as
its preset values correspond to the following
specifications :
• Input Natural Gas (at Battery Limit):
Temperature: 20,0 °C
3
Density: 0,79 kg/Nm
Pressure: 4,0 bar (g)
Flow (feed + fuel): 111 Nm3/h
Composition : CH4 90,8 Vol-%
C2H6 3,3 Vol-%
C3H8 1,2 Vol-%
i/n-C4H10 0,5 Vol-%
i/n-C5H12 0,1 Vol-%
CO2 0,5 Vol-%
O2 0,5 Vol-%
N2 3,4 Vol-%
Feed Pretreatment
Natural Gas from battery limits (B.L.) at a pressure
⇒ see P+I diagram
between of 4 bar (abs) is divided in two streams.
1-27-520949-0 sheet 1
One is used as fuel and sent to the reformer
⇒ Steam reformer D13101 burners in D13101. The other one is mixed with a
see P+I diagram
H2-recycle stream from the PSA-unit to the feed
1-27-520949-0 Sheet 2
gas and will be compressed by a watercooled
⇒ Feed preheater W14001 piston compressor to a pressure of 20 bar (g).
see P+I diagram
1-27-520949-0 Sheet 3 The feed + H2-recycle stream is warmed up to
approx. 390 C in the feed-preheater W14001 and
then fed in the desulphurization reactor C10201.
The reactor is filled with a catalyst composed of
zinc oxide, molybdenum oxide and copper oxide.
The following reactions take place:
• Unsaturated hydrocarbons are hydrogenated.
The temperature in the reactor rises pro-
portionally to the content of the unsaturated
hydrocarbons in the feed. The maximum
tolerable content of unsaturated compounds is
2%.
⇒ W14003 see P+I diagram • The final cooling-down of the converted gas to
1-27-520949-0 Sheet 4 approx. 35 - 45 °C is conducted in the water
cooler W14003.
⇒ F14001 see P+I diagram
1-27-520949-0 Sheet 4
During the cooling-down process the excess
steam in the converted gas is condensed and
separated in process knock-out drum F14001.
The process condensate will be recycled during
normal operation or sent to the sewer system
respectively to the Battery Limits.
The converted gas enters the PSA-system
A14101–A14104.
Pressure-Swing-Adsorption System
In the PSA-system the hydrogen is separated
from the impurities, eg. H2O, CO, CO2, N2 and
⇒ PSA see P+I diagram
1-27-520949-0 Sheet 5 CH4.
The PSA-system consists of 4 Adsorber A14101–
A14104, each filled with 3 types of adsorbents.
The impurities are adsorbed at product pressure.
The regeneration of the adsorbents takes place by
depressurization to low pressure and purging.
A complete cycle consists of the following steps:
Adsorption: During the adsorption step, the
process gas enters the bottom of the Adsorber.
The impurities are adsorbed and the high pure H2
leaves the Adsorber on top. The pressure in the
PSA-unit is kept at a constant level by a pressure
control valve in the H2-line. When the adsorption
step is finished, automatically a regenerated
Adsorber is switched on adsorption, thus a
continuous product flow is achieved.
Regeneration: The regeneration of the exhausted
Adsorber starts by depressurization to a low
pressure level. During this step most of the gas is
used for depressurization and purging of other
Adsorber, which are in different stages of
regeneration. The final depressurization gas is fed
in the purge gas vessel B14201.
Purging: The pressure in the Adsorber is about
ambient pressure. The Adsorber is purged with
System H2-plant
Type steam reforming
Manufacturer Mahler AGS
Customer HABAS
Izmit / Turkey
Constructed in Year 2012
3
Nominal capacity 250 Nm /h
Plant dimensions:
Width 31200 mm
Depth 30000 mm
Height approx. 26000 mm
Load, see Foundation diagram
1-19-519-484-0
Input:
3
Natural Gas Flow 111 Nm /h
Temperature 20 °C
Pressure 4 bar (g)
3
Density 0,79 kg/m
3
Nitrogen Flow 60…80 Nm /h
Purity: 99,99 Vol-% Temperature 20 °C
Pressure 6 / min. 4 bar (g)
3
Density 1,250 kg/m
3
Instrument air Flow 15 Nm /h
Temperature Amb. °C
Pressure 5-7 bar (g)
3
Cooling water Flow 11 m /h
Temperature 27-30 °C
Pressure 4-5 bar (g)
Outlet:
3
Product gas Flow 250 Nm /h
Pressure 12 bar (g)
Temperature 30-40 °C
3
Density 0,090 kg/Nm
Power required
Voltage 3x380 VAC
N/PE
Frequency 50 Hz
Installed Power 78 KW
2.5.2 Nitrogen
3
Flow 60 – 80 Nm /h
Temperature 20 °C
Pressure min. 4 bar (g)
3
Density 1,250 kg/m