TRUSCOPE Vital Signs Monitor

Features: Optional:
 Light weight & portable Vital Signs monitor  Nellcor or Masimo technology for SpO2

 7” high resolution colour Anti-glare TFT LCD display  Microstream ETCO2

 NIBP, Pulse Rate and SpO2 monitoring  Instant infra-red ear thermometer

 Lithium ion battery for longer operating hours


 Up to 1000 patient recording storage
 Up to 96 hours of trend data storage with 1 minute
resolution

Standard Configuration:
 NIBP, Digital SpO2, Pulse Rate
Asia
SCHILLER Asia-Pacific
® 52200 Kuala Lumpur, Malaysia
TechnicalSpecificationsofTRUSCOPEVitalSignsMonitor Phone +603 6272 3033
sales@schiller.com.my
www.schiller-asia.com

Austria
SCHILLER Handelsgesellschaf t mbH
General Performance A-4040 Linz
Phone +43 732 70 99-0
Size and Weight BLT Digital SpO2 sales@schiller.at
- Size : 160 x 130 x 260 mm (W x H x D) - Measurement range (0~100)% www.schiller-austria.com
- Weight: (2.5 kg) (including lithium battery) - Resolution: 1%
- Accuracy: + 2% (70%~100%) China
+ 3% (35%~69%) SCHILLER International Trading Co. Ltd.
Display - Unspecified (0~34%) 200335 Shanghai, China
-Type: 7” Anti-glare TFT LCD
Phone +8621 6209 9627
-Resolution: 234 x 480 pixels
sales@schiller.com.my
Masimo SpO2 (Option)
www.schiller.cn
- Measurement range (0~100)%
Power Supply - Resolution: 1%
- Input voltage: AC: 100-240V, 50 Hz/60Hz France
- Accuracy: + 2%(70%~100%)(adult/pediatric, non-motion conditions) SCHILLER Médical S.A.S.
- Input power: 70 VA + 3% (35%~69%) (neonate, non-motion conditions) F-67162 Wissembourg/Cedex
+ 3% (35%~69%) (motion conditions) Phone +33 3 88 63 36 00
Battery - Unspecified (0~69%) info@schiller.fr
- Type: 11.1V 4000mAh rechargeable lithium ion battery www.schiller-france.com
- Operating time: >8 hours
- Charge time: 6h to 100% (Standby) France (bureau Paris)
Nellcor SpO2 (Option)
SCHILLER France S.A.S.
- Measurement range (0~100)%
F-77608 Bussy-Saint-Georges
Data Storage - Resolution : 1%
Phone +33 1 64 66 50 00
- Clinic Mode: - Accuracy: + 2% (70%~100%)(adult) info@schillerfrance.fr
Patient quantity: 1000 + 3% (35%~69%) (Neonate) www.schiller-france.com
Recording number: 16000 + 2% (35%~69%) (low perfusion)
Single patient clinic record number: 1~16000 - Unspecified (0~69%) Germany
- Monitor Mode: SCHILLER Medizintechnik GmbH
Patient quantity: 1 NIBP D-85521 Ottobrunn
Trend data: Resolution 1 Min: can store 96 hours - Technique: Automatic Oscillometry Phone +49 89 62 99 81-0
Resolution 5 Min: can store 480 hours info@schillermed.de
- Range: Adult: 10~270mmHg
Resolution 10 Min: can store 960 hours www.schiller-germany.com
Child: 10~235mmHg
Alarm events: 1000 Neonate: 10~135mmHg
NIBP measurement record: 5000 Hungary
- Accuracy: Static: +3 mmHg
SCHILLER Diamed Ltd.
- Clinic: Average error: +5 mmHg
H-1141 Budapest
Environmental Specifications - Standard deviation: <8 mmHg
Phone +36 (1)460 05 92
-Operating - Unit: mmHg, kPa sales@t-online.hu
Temperature: (5~40)˚C - Pulse rate range: 40-240 bpm www.schiller-hungary.hu
Humidity: < 85% (noncondensing)
Atmospheric Pressure: (700~1060)hPa Microstream ETCO2 (Option) India
SCHILLER Healthcare India Pvt. Ltd.
- Measurement way: Infrared spectrum
- Transportation and Storage Mumbai - 400 059, India
- Sample flow rate: 50 ml/min + 10 ml/min
Temperature: (-20~+55) Phone +91 22 6152 33 33
- Measurement range: (0~19.7)%, (0~150 mmHg)
Humidity: < 93% (noncondensing) sales@schillerindia.com
- Resolution: 0.1% or 1 mmHg
Atmospheric Pressure: (500~1060) hPa www.schillerindia.com
- Unit: %, mmHg, kPa
- Accuracy: + 2 mmHg 0mmHg to 40 mmHg,
Japan
PR + 5% of reading 41 mmHg to 70 mmHg, SCHILLER Japan, Ltd.
- Measurement range: 20~250 bpm + 8% of reading 71 mmHg to 100 mmHg, Hiroshima 734-8551
- Resolution: 1 bpm + 10% of reading 101 mmHg to 150 mmHg, Phone +81 82 250 2055
- Accuracy: + 1% or + 1 bpm, whichever is greater (760 mmHg, temperature is 25˚C) koji.maekawa@schiller.jp
(When RR> 80 rpm, all the range is +12% of reading) www.schiller.jp

Certification: Poland
CE 0123 SCHILLER Poland Sp. z o.o.
PL-02-729 Warszawa
Phone +48 22 843 2089
Standard accessories schiller@schiller.pl
- Power cord - 1 no. www.schiller.pl
- SpO2 probe with extension cable - 1 no.
- NIBP–Adult, paediatric & Neonatal cuff Russia & C.I.S.
- NIBP extension tube SCHILLER AG
- Grounding wire - 1 no. 125124 Moscow, Russia
- User manual - 1 no. Phone +7 (495) 970 11 33
mail@schiller-ag.com
- Warranty card - 1 no.
www.schiller-cis.com
- Packing list -1 no.
Spain
SCHILLER ESPAÑA, S.A.
E-28230 Las Rozas/Madrid
Phone +34 91 713 01 76
schiller@schiller.es
www.schiller-spain.com

Switzerland
SCHILLER-Reomed AG
CH-8953 Dietikon
Phone +41 44 744 30 00
sales@schiller-reomed.ch
www.schiller-reomed.com

Turkey
SCHILLER TÜRKIYE
Okmeydani - Sisli - Istanbul
Phone +90 212 210 8681 (pbx)
sales@schiller-turkiye.com
www.schiller-turkiye.com

USA
SCHILLER America Inc.
Doral, Florida 33122
Phone +1 786 845 0620
sales@schilleramerica.com
www.schilleramerica.com

Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone +41 41 766 42 42, Fax +41 41 761 08 80, sales@schiller.ch, www.schiller.ch