You are on page 1of 1

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS & LEVELS ARE IN


METERS UNLESS OTHERWISE NOTED.
2. THE DRAWING SHALL NOT BE SCALED, ONLY WRITTEN
DIMENSIONS SHALL BE USED.
3. DIMENSIONS DO NOT INCLUDE RENDER (OR) PLASTER
FINISHES, UNLESS OTHERWISE INDICATED.
4. READ THIS DWG. IN CONJUNCTION WITH ARCHITECTURAL
STRUCTURAL & MEP DWGS.

6 7 8

9
M
Utilities ElectricalSU-01 UP
Room STAIR
1 2 3 4 5 6 7 8 9 10 11 12

10
24 23 22 21 20 19 18 17 16 15 14 13
4

+7.500
F.F.L
L

ET
IL
TO
Utilities DUCT SHAFT

EN
Mechanical MEN's

oo or

M
R nit
m
Room TOILET

Ja
ELEVATOR
SU

nt -01
-0 LOBBY
K

SU
1

ry
WOMEN's

Pa
TOILET
E
3

IU IC

11
-0 FF
6
O

O G
O IN
R INT
M
PR
REFERENCES:

M
Engineering DRAWING NUMBER DRAWING TITLE

O
IU-06

O
CNP & FA E19016-MDE-00-90-E-GG-001-1c ELECTRICAL LEGENDS AND ABBREVIATIONS

-0R
4
E

Department
IC

E19016-MDE-00-90-E-DT-001-1c ELECTRICAL TYPICAL INSTALLATION DETAILS -1

GIU
FF

12
N
E19016-MDE-00-90-E-DT-002-1c ELECTRICAL TYPICAL INSTALLATION DETAILS -2
Department
O

LI
E19016-MDE-00-90-E-DT-003-1c

FI
ELECTRICAL TYPICAL INSTALLATION DETAILS -3
2

E19016-MDE-00-90-E-DT-004-1c ELECTRICAL TYPICAL INSTALLATION DETAILS -4


E19016-MDE-00-90-E-DT-005-1c ELECTRICAL TYPICAL INSTALLATION DETAILS -5
N HUDDLE ROOM HUDDLE E19016-MDE-00-90-E-DT-006-1c
SO
ELECTRICAL TYPICAL INSTALLATION DETAILS -6
E

ROOM E19016-MDE-00-90-E-DT-007-1c ELECTRICAL TYPICAL INSTALLATION DETAILS -7

E
R
IC

IC
E E19016-MDE-00-90-E-DT-008-1c
FF

ELECTRICAL TYPICAL INSTALLATION DETAILS -8

FF
P
00
O

E19016-MDE-00-90-E-DT-009-1c
2 ELECTRICAL TYPICAL INSTALLATION DETAILS -9

13
-1
L .5

O
F. +7

IU-07

IU-07

PE
E E
IC C
1

N
F EN

O
F
F.

1
R

-0

FF
FE
IU

8
-06

-0
N N

IC
O

IU
E O
E

E
C
IC

P
R

-1
FF

0
O

PE
1c Submit for approval 21-03-2021 SAM OMLA

2 E

E
8
IU

-0 C

-0

IC
R
-0

M N
1b Submit for approval 08-03-2021 SAM OMLA

IU

FF
6

O E

SO
O R

O
1a Submit for approval 23-02-2021 SAM OMLA

R FE

N
F.
N
Rev. Description of change Date Drawn Approv..

F.
O

+7
L
C
E- R

.5
FF C /
IC TO
O IRE M

00
01

KEY PLAN:
D G

LOADING AND UNLOADING AREA

E
IC
FF
O
Y
AR

E
IC
ET

FF
R
C

O
IU
SE
Y

Y
3
-0

-0
AR

AR
C
3

IU

FH
SECURITY ROOM
FH

X-RAY ROOM

NETWORK EQUIPMENT ROOM

TOILET

PRAYER AREA

F
C
ET

ET
01

IU
-0
ADMINISTRATION BUILDING
R

R
6
E- R

PRAYER AREA

WEIGH BRIDGE OFFICE

TOILET

NETWORK EQUIPMENT ROOM

NETWORK EQUIPMENT ROOM


ARM BARRIER

TOILET

X-RAY ROOM

PRAYER AREA ARM BARRIER


C

C
SECURITY ROOM
FF C /

ROAD BLOCKER

ROAD BLOCKER ROAD BLOCKER


IC TO

A
O IRE M

02
SE

SE
4

D G

PROJECT:
-0
IU

E
IC
InoChem Non-Process Buildings &

FF
O
Facilities for Soda Ash & Calcium
.5 00

F.
+7

F.
L
24 24 L Chloride Plant

+7
F.
23 23
F.

.50
22 22
CLIENT:

0
21 21
UP 1
20
1 UP
2 20 2
19

G
3 19 3
18 18
4 4
B

17 17
5 5
16 16
6 6
15 15
7 7
14 14
8
13 13
8 PROJECT ENGINEER:

R
9 9

AI
10 10

ST
11 11
12 12
R
AI
ST

H
CONTRACTOR:
C

Al Khobar 31592
P.O. Box No. 31002
Kingdom Of Saudi Arabia
Phone No. +966138877505

I
Fax No. +966138872032
D

www.criticalengineering.com.sa
DESIGNER:

SUBCONTRACTOR:

J
E

Project: Building:

InoChem NPF for Soda


Ash & Calcium Chloride ADMINISTRATION
Plant
Drawing Title:

SECOND FLOOR PLAN


POWER FOR MECHANICAL
SYSTEM LAYOUT
Drawing Number: E19016-MDE-01-90-E-2F-003-1c Scale: 1 : 60

E19016 MDE 01 90 E-2F-003 1c


Project Building Design Drawing
Developers Discipline Level Revision
Number Number Stage Number

Drawn by: SAM Checked by: OMLA Date: 21-03-2021


This drawing and all information herein contained is the property of Critical Engineering Company and cannot
be copied, reproduced, utilized or modified for purposes other than those for which drawing has been made.

FILE NAME : 03-POWER FOR MECH SYSTEM

You might also like