Professional Documents
Culture Documents
GENERAL
Change Management Package is used for managing changes occur during engineering work. This software helps
engineers to reduce omission and mistakes in the engineering work. The information of planing, implementation,
and test can also be recorded.
This software is an optional function of Automatic Design Suite (AD Suite). (*1) It is available for ProSafe-RS and
ProSafe-RS Lite (*2).
The Change Management Package is applicable to the following safety control stations (SCSs):
SSC50S, SSC50D, SSC57S, SSC57D, SSC60S, SSC60D, S2SC70S, S2SC70D, L1SC70S, L1SC70D
*1: For the details of AD Suite, refer to the GS “Automation Design Suite (AD Suite), RS4E5000 Engineering Server Function,
RS4E5100 Safety System Engineering and Maintenance Function” (GS 32P04C10-01EN).
*2: When used for ProSafe-RS Lite engineering, it has been supported since ProSafe-RS R4.06.
FUNCTION SPECIFICATIONS
l Change management workflow
The figure below shows an example of change Modification Package (ModPack)
management workflow using the AD Suite. ModPack is a form containing a collection of all the
information related to a particular change. A ModPack
cosists of various information such as changes in an
Start ID number, a status, a person in charge, a place, and
a test procedure. A file with test results and other data
can also be attached to the ModPack.
Define the change as a Modpack
Define the change as a Modpack
Various kinds of information such as a place, a person
in charge, a procedure, and a test procedure are
Implement the change defined as a ModPack.
Implement the change
Based on the data defined in the ModPack, change
Attach files to the ModPack works and testing are manually implemented. The work
is associated with the ModPack by checking in the
change details.
Status Description
Created Initial status when a ModPack is created
Assigned An engineer is assigned to the ModPack
In-progress ModPack is being implemented
Tested ModPack verification is completed by the engineer
Validated The authorized engineer has decided that the change of ModPack is valid
Accepted The change to the ModPack was accepted
Rejected The authorized engineer has decided that the change of ModPack is invalid
SYSTEM REQUIREMENTS
Refer to the GS “ProSafe-RS Safety Instrumented System Overview (for Vnet/IP)” (GS 32P01B10-01EN),
“ProSafe-RS Safety Instrumented System Overview (for Vnet/IP-Upstream)” (GS 32P01B30-01EN), or ”ProSafe-RS
Lite Safety Instrumented System Overview” (GS 32P51B10-01EN).
ORDERING INFORMATION
Specify the model and suffix code(s).
TRADEMARK ACKNOWLEDGMENT
The names of corporations, organizations, products and logos herein are either registered trademarks or trademarks
of Yokogawa Electric Corporation and their respective holders.
All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 32P04C30-01EN Jan. 22, 2021-00
Subject to change without notice.