You are on page 1of 6

1 2 3 4 5 6 7 8

STAGE 1
STAGE 3
A
DIG HOLE TO 500MM DEEP MIN A

DIG DRAINAGE (IF APPLICABLE) AND DUCT TO CABINET BACK FILL WITH C35 CONCRETE
DUCT TO BE APPROX 70mm WITH MIN 200mm RADIUS ON BENDS UP TO DESIRED LEVEL
CAREFULLY POSITION PIT LINER USING MEASURMENTS (THIS CAN BE TO FINISHED FLOOR LEVEL
ENSURE IT IS LEVEL IN ALL DIRECTIONS OR BELOW TO ALLOW FOR PAVING, TARMAC ETC)
FINISHED PIT MUST BE 100MM MINIUM AWAY FROM NB - TAKE CARE NOT TO LET THE CONCRETE TO
ADJACENT WALLS OR HANDRAILS TO AVOID ENTRAPMENT BEND IN THE SIDE WALLS OF THE PIT LINER
IT IS RECOMMENDED TO BRACE THE INSIDE
CONNECT UP DRAINAGE WALLS BEFORE POURING
CONNECT UP DUCT
POSITION 6MM RE-BAR 2 EITHER SIDE
B
AND 2 AT REAR CROSSING OVER
75MM UP FROM BASE
B
POSITION SEVERAL VERTICAL RE-BAR TO
TIE IN BACK FILL

C C

STAGE 4
FINISH FLOOR SURFACE UP TO STAINLESS FRAME

STAGE 2
D D

FILL BASE WITH C35 CONCRETE


TO 5mm BELOW RAIL TOPS
CHECK MEASUREMENTS
ALLOW TO SET
ENSURE PIT LINER
IS LEVEL

DO NOT SCALE DRAWING REVISION

NAME SIGNATURE DATE TREATMENT: DRAWING NOTES :


DRAWN DEBUR AND BREAK SHARP EDGES
CHK'D
PIT FORM POSITIONING
UNLESS OTHERWISE USED ON:
SPECIFIED:
F DIMENSIONS ARE IN
MILLIMETERS MATERIAL / MADE FROM
A3
DWG NO.

PR9 PIT LINER SET OUT DRAWING


1 2 3 4 SHEET 1 OF 1
1 2 3 4 5 6 7 8

A A

B B

75MM DUCT IN TO ADJACENT


CUPBOARD
FRONT OR EITHER SIDE
NO TIGHT ELBOWS MIN 200MM
C/W DRAW STRING

C C

D D

100 MM DRAIN TO EXISTING


FOR EXTERNAL INSTALLATIONS
OR SUMP WITH PUMP IF NO DRAIN

DO NOT SCALE DRAWING REVISION

NAME SIGNATURE DATE TREATMENT: DRAWING NOTES :


DRAWN DEBUR AND BREAK SHARP EDGES
CHK'D

UNLESS OTHERWISE USED ON:


SPECIFIED:
F DIMENSIONS ARE IN
MILLIMETERS MATERIAL / MADE FROM
A3
DWG NO.

PANOVA PIT DETAIL


1 2 3 4 SHEET 2 OF 3
1 2 3 4 5 6 7 8

A A
90 35

Builder to prepare double


gang back box
(135x70mm, 35mm deep)
into walls for flush fitting
As an alternative to control button box to be
B
up and down installed at either or both
B

buttons, a Key top/bottom landings as


switch can be agreed
provided instead to
prevent Builder to install minimum
unauthorised use 20mm cable duct from

130
C
(Dimensions not back box to the control C

affected) cabinet location


170

Drawstring to be left in duct


for installer to pull through
cabling during lift
installation
D D

64
METAL DOUBLE GANG
BACK BOX
DO NOT SCALE DRAWING REVISION

NAME SIGNATURE DATE TREATMENT: DRAWING NOTES :


DRAWN DEBUR AND BREAK SHARP EDGES
CHK'D
STANDARD BUTTON PLATE
UNLESS OTHERWISE USED ON:
SPECIFIED:
F DIMENSIONS ARE IN
MILLIMETERS MATERIAL / MADE FROM
A3
DWG NO.

PR9-4-2034 BUTTON PLATE


1 2 3 4 SHEET 1 OF 1
1 2 3 4 5 6 7 8

WALL MOUNTED CABINET TO BE SITUATED WITHIN 10M OF LIFT SAFETY CONTACTORS


LOGIC CONTROLLER FUSES
A
** DENOTES EXTERIOR CABINET SIZES MANUAL CONTROLS A

POWER SUPPLY (ENGINEER ONLY)


406 **380 654 **800 RELAYS
PUMP MOTOR

PRESSURE
GAUGE

B B

726 **800

C C

D D

100MM CLEAR SPACE REQUIRED OIL LEVEL


FOR PIPES UNDER CABINET MOTOR MCB
UPS HAND PUMP
(BACK UP SUPPLY)
VALVE MANUAL CONTROL

E 13A Single phase 230VAC Dedicated Supply Required, terminating


adjacent to the control cabinet location on a lockable rotary
isolator. MCB Protection required, not RCD.
24VDC Control Circuit
WALL MOUNTED BUTTON PLATE
MOUNT ADJACENT TO LIFT 250KG Rated Load DO NOT SCALE DRAWING REVISION

AVAILABLE WITH KEY SWITCH AUTHORISATION NAME SIGNATURE DATE TREATMENT: DRAWING NOTES :
DRAWN DEBUR AND BREAK SHARP EDGES
CHK'D

UNLESS OTHERWISE USED ON:


SPECIFIED:
F DIMENSIONS ARE IN
MILLIMETERS MATERIAL / MADE FROM
A3
DWG NO.

PANOVA CABINET AND CONTROLLER


1 2 3 4 SHEET 3 OF 3
1 2 3 4 5 6 7 8

A A

126

B B

C C

LIFT SUPPORTED
IN DOWN POSITION
D D

DETAIL A
SCALE 1 : 5

POINT LOAD 333KG 700


E

LOADINGS FOR ONE WHEELCHAIR USER @ 125KG


DO NOT SCALE DRAWING REVISION

NAME SIGNATURE DATE TREATMENT: DRAWING NOTES :


DRAWN DEBUR AND BREAK SHARP EDGES
CHK'D

MULTIPLY FLOOR COVERING WEIGHT BY 1.21 UNLESS OTHERWISE


SPECIFIED:
USED ON:

AND ADD IT TO THE POINT LOADING


F DIMENSIONS ARE IN
MILLIMETERS MATERIAL / MADE FROM
A3
DWG NO.

PR9-4-1000 LOADINGS 125kg


1 2 3 4 SHEET 1 OF 2
1 2 3 4 5 6 7 8

622
A A

LOADING WITH SUPPORTED LEADING EDGE


IN THE UP POSITION

B B

C C
B

D D

E POINT LOAD 491 KG


DETAIL B
SCALE 1 : 4
LOADINGS FOR 0NE WHEELCHAIR USER @ 125KG
DO NOT SCALE DRAWING REVISION

MULTIPLY FLOOR COVERING WEIGHT BY 1.79 DRAWN


NAME SIGNATURE DATE TREATMENT:

DEBUR AND BREAK SHARP EDGES


DRAWING NOTES :

AND ADD IT TO THE POINT LOADING CHK'D

UNLESS OTHERWISE USED ON:


SPECIFIED:
F DIMENSIONS ARE IN
MILLIMETERS MATERIAL / MADE FROM
A3
DWG NO.

PR9-4-1000 LOADINGS
1 2 3 4 SHEET 2 OF 2