«) FEDERAL General Federal Load Break Switches are being manufactured with or without fuses according to the IEC/EN 6047-3 land VDE 0660 standards. They have been designed to provide instant ON-OFF ‘switching with rubbed and rolled contacts. They have a breaking capability from four different points at the same phase. Various combinations and types with high ampers which are not shown in the brochure are manufactured by order, on request. Application Federal FSF and FLS type Load Break Switches are the latest improved mode!s in the world, and may be applied: ‘As a main switch on distribution panels, ‘As a motor switching, As a disconnector, ‘As an emergency switch on AC/DC low voltage circuits. General Characteristics - High breaking capacity (AC 23-A.IEC/ EN 60947-3) High electrical and mechanical endurance Rolling contact system (except for 160 A) capable of self - cleaning = Double breaking on each phase - Modern tecnology and compact design - Instant closing and breaking operation independent from manual operation Small dimension - Case made of thermoset material, non absorbing and flame & heat resistant Capable of mounting to front or rear side of the panel. Locking With Padlock “0” Position 4 1 Rolling Contact System (250A, 400A, 630A) os [Tis 120 I E ' ee) © Safety Off “0” position both fuse terminals will not be alive so the fuses can be changed, safely. = On" position the handle will be locked mechanically, so the panel cannot be opened while energized - Off “0” position the handle can be blocked out with padlock so it is prevented that unauthorized personnel to energize the panel ~ The isolation distance between the phases is rather wide to prevent arc jumping, - Additional fuse protection shields are used for better isolation and protection in the switch fuses. ~ Arc separators are used for arc extinguishing between contacts which occur during closing or breaking process, Design Features = The *0” and “I” positions are shown both on the handle and on the indication plate, clearly. - The change angle of the handle between “0” and “I" Position is 90° - The handle mechanism hole which the control shift installed is made of metal alloy, so any depreciation is, out of question - The control shaft length can be arranged depending ‘on the depth of the panel. ‘Switch Fuses With Terminal Covers Terminal Covers FSF 250 FSF 160 FSF 400 FSF 620 Technical Characteristics ‘TYPE ee FSF 160, FSF 250 FSF 400 FSF 630 Number of pole 3.4 3.4 a4 3.4 Rated thermal current (th) A160 250 400 630 Rated insulation votage (Ui) V_1000 41000 1000 1000 Rated impulse withstand votlage - Vimp 8 e 8 8 Rated frequency He | 40-60 [a060 4060 4060 Fated operating power 20 ww [7s [ose 00 i leas 500v ew 100 [160 200 340 ea0v ew 120 220 360) 400 Reactive power a8ov war 176 140 220° 300 Fated breaking capaity AC 28. ‘A | 1280 2000 3200 5040 Rated making capacty AC 23 A | 1600 2500 4000 6900 Seater tere ka | 100 100 | 100 | 100 Fuse type NH 00 i 2 3 Mechanical ite Operation |> 10000 > 10000 |> 10000 > 8000 Electrical lite Operation > 1000 > 1000 > 1000 > 1000 Weight wg [27 47 48 87 Min, connection conductor erossecion am? |70 120 [240 2x185 Dimensions pecan s for FSF 690) Bi EGE eras [AS |S RS | | JP [Ro FSF 160 [105 [142 [129 [1055/57 [435 [15 [92 28 13 (ao [13 [160 [12/162 3 Fepang 12525 169 1905/1275 |/aa8 [es [165 [os lo [4 (lis |200 Jans |r |107 1 FSF 400 | 30 . Fsr6s0 |si7s (240 [ace |1e4 [50 eo |165 [54 a7 6 (40 (835 |2t95|14 2205 8 FEDERAL GROUP MEMBER COMPANIES FEDERAL ELECTRIC Investment & Trade Co. FEDERAL MARBLE Investment & Trade Co. FEDERAL Marketing (for domestic market) FEDERAL Foreign Trade Company FEDERAL Machinery & Molding Company FEDERAL Marketing Ukraine LTD. FEDERAL ELECTRIC Trading LTD. UK. FEDERAL Marble INC. USA. FEDERAL ELECTRIC Investment & Trade Co. Factory & Center: 4. Organize Sanayi Boiges! 1. YoI No. 25 ADAPAZARI/ TURKIVE Tel = 490.264, 291 45 00 Faks : +90.264.275 41 81 web = wwwfederal.com.tr ‘e-mail : federal@tederal.com tr FEDERAL ELECTRIC is a member company of Federal Group FEDERAL ELECT! Yruclies f + Moulded Case Circuit Breakers + Contactors * Contactors * Contactors For Capacitor Switching + High Current Contactors + Low Voltage Power Capacitors + Relays + Reactive Power Control Unit * Motor Protection, Phase Sequence and Liquid Level Relays + Phase Protection Relays + Ground Fault Relays + Thermal Overload Relays + Timers + Counters + Thermostats + Miniature Circuit Breakers + Residual Current Circuit Breakers + HRC Fuses and Fuse Bases + Motor Protection Switches + Load Break Switches & Switch Fuses » + Low Voltage Current Transformers + Panelmeters (Analog and Digital) + Ammeters a + Max. Demand Ammeters al + Voltmeters + Frequencymeters Bi + Multi-Tariff Electronic Energy Meters + Automatic Control Unit of Heating System for S tr Passenger Coach (Railway Car) BE 9R02 E02 (0709) CERTIFICATE OF ASSESSMENT AQA INTERNATIONAL, LLC, attests that: «} FEDERAL FEDERAL ELEKTRIK YATIRIM VE TICARET A.S. 1 oRGANRE SY BOLOES HAN ELDES|-ADAPAZAR-SAKARYA TORE with a scope of Design and Production of Low Voltage Circult Breaking and Swiching Devices, Measuring, Control and Protection Devices, Capacttors, Watthourmeters, Watermeters, Gasmeters, Prepayment System and Prepayment Meters {sin compliance with the International Quality System Standard ISO 9001:2008 * Further clantcations regarding the scope ofthis ceca and the apacabity of 180 9001;2008 requirements may be obtained by consulting the organization. ~ CertcateNo: TRO02I77 Fesictation Prod: 14 Apr! 20101018 Ap 2013, Ina Region; 18 Ap 2004 Last Modiad: 14 Apri2010 ANA 9 FEDERALELEKTRiK TEL NO a Kes. 3a zou zien z e ‘ ¢q FEDERAL ELEXTRIR YAMA ETICAS LOW VOLTAGE SWITCHGEAR Report No : 200{001 TEST REPORT Date: 27/02 2001 TEST REPORT SUBJECT TYPE : LOAD BREAK SWITCH-FUSE FSF 160 LOAD BREAK SWITCH SERIALNO _: FS01600007007974 CONTENT OF TEST Type and Routine tests. Ue : 400 V AC (Rated ope. TESTED IN ACCORDANCE WITH IEC 60947-3 volt) TEST PLACE : FEDERAL ELEKTRIK YATIRIM VE TIC. AS. REPORT ISSUED : 1 .SAHIN TESTED BY 1H. BOZTAS No Of pages 24 Laboratory Techniciané Laboratory Engineer : ‘Confirmation: L a ee ALTASCI L Eon 9 Poa NoToITe Ta Discaiin? Quay Rsramee NOOB Tes Rav, NO: 00 FEDERALELEKTRIK TEL NO. : Kas, 3¢ 2001 12:21 40; Copper conductors x ; 4 pee LOW VOLTAGE SWITCHGEAR _ |Report No:2001001 YARMYETIC.AS TEST REPORT Date : 27/02/2001 1, Verification of temperature-rise (sub-clause 8.3.3.1) Test conditions. Rated current A 160 Supply source Single phase Frequency (Hz) 50 Test current (A) 160 /100 Test connection PVC insulated Number: 1 Same as test Size /70 mm conditions Length of connection from Terminal to terminal =2 m. Test duration (h) Ee 8 (max) ‘Ambient air temp during the (°C) A ee +10 tor40 Use of enclosure No Z 1.2. Test Results Rated current Extemal | Measured Temp, Rise] Temp, Rise limit i connection | temp. (°C) () Top. R 64 43 Side 7 46 80 |Terminats | T 63 42 160A | Bottom R 56 36 Side se 99 sae 80 | Terminals fT 60 | Po eee eee Handle 41 20 Contact Note Note : Limited solely by the necessity of not causing any damage to insulating materials. n Hau eeees Taira ‘Engineetex , ‘Confirmation : fTocahim SAHIN tsmail TASC! brahim a FomNoroiFse ev. No:00 CRGFODLARIOET Dibation Quilly Assurance MOCB Ter 1 FEDERALELEKTRiK TEL NA. 4181 kes. 38 2001 1 su ANE ¢fpp FERAL LETS | LOW VOLTAGE SWITCHGEAR _ | Keon No 2001001 » ARRIVE TAS, TEST REPORT Date ..27 02/2001 2. Tests of dielectric propertics (8.2.3.3) Test conditions. Rated current (A) 160 IEC Rated insulation i Woltage : Ui ™ 4000 Requirement Frequency of Supply Source (Hz) 50 45-62 Hz. Test voltage W) 3500 3500 V. Test duration ‘min 1 min, [—~ ‘a)- With the LVS in the close position, i) Between ail live parts of all poles connected : together. i) Rand the frame of the LVS : Between each pole and all the other poles connected to the frame of the circuit breaker b)- In the open position and in the tripped Same as test estice conditions |) Between all live parts of all poles connected together and the frame of the LVS {i) Between the terminals of onside. connected together and the terminals of the other side connected together. 3.2.2, Test Results Test Test Test Test | a) i a) iii b) t b) il Positive |v [Positive | [Positive | V [Positive | v | {Negative | | Negative | Negative Negative | Laboratory ‘Technician : Laboratory Engineer ; ‘Confirmation : 1 SAHIN ‘1. TASCT L AXDIN a aR NSTTOTETTE TROTRSEARTOTENE Dian age Rev. No:0) Ft FEDERALELEKTRIY TEL NO. 754181 kas, (x) indicated test carried out. Note : for these test see attached sheet. ‘Laboratory Techni: os Form No: JOTST Coron Rev. No:00 Laboratory Engi .TASCL Dissibaton Qualiy Asura, NCCE Tat 4 proms LOW VOLTAGE SWITCHGEAR __[®:port No: 2001001 wane AS. TEST REPORT Date : 27/02/2001 1, Ratings and specifications Type designation FSF160 Number of poles 3 Rated ope. Voltage. U. Vv |400 | Rated ope. Current |. A_|160 Rated insulation Voltage U, v_|1000 | Rated frequency Hz [40-60 | Rated short circuit Bre. Cap. Using fuses | kA |100 i Electrical Life ope. | 1000 | Mechanical Life ope. | 10000 | Drive Manual ope. | Fuses used and max. power loss w /i2 | Type of fuse NHOO i Sub. Clause 4. Temperature rise 8.3.3.1 3 &) 2. Dielectric properties 8.3.3.2 Type Test 8. Making and breaking cap, 8.3.3.3 4. Dielectric verification 8.3.3.4 5. Temp.-tise verification 83.36 Routine |1: Mechanical ope. Test 8.4.2, ®) Test _ [2. Resistance control ® | - 2 FEDERALELEKTRIK TEL NO. 1 2754 kes a A ¢ App FEDERAL, ELEXTROR, LOW VOLTAGE SWITCHGEAR YAIRLAYETICAS TEST REPORT 30 2001 12:26 Si Report No : 2001003, Date : 27/02/2001 1, Ratings and specifications Type designation FSF400 Number of poles 3 Rated ope. Voltage. Us v_|400 Rated ope. Current ly A_|400 Rated insulation Voltage U; v_| 1000 Rated frequency Hz |40-60 Rated short circuit Bre. Cap. Using fuses’ | kA |100 Electrical Life ope. | 1000 Mechanical Life ope. | 10000 Drive Manual ope. Fuses used and max. power loss w {32 . Type of fuse NH2 Sub. Clause | 4. Temperature rise 83.3.4 ® | 2. Dielectric properties 8.3.3.2 ° | Type Test - | 3. Making and breaking cap. 8333 | 4, Dielectric verification 8.3.3.4 - 5. Temp.-rise verification 8.3.3.6 Routine |1. Mechanical ope. Test 8.4.2, ) | Test _ |2. Resistance control & (x) indicated test carried out. . Note : for these test see attached sheet. \ Laboratory Techni Laboratory Engineer Confirmation: ‘LSAHIN ee /. Lrasqr irs a) LAYDIN ev. No:00 Fogo! 10.1831 CREO ‘Datibaion Qualiy Assarinee, OCB Tex 18 EDERALELEKTRAK TEL NO. ? 2754161 kes. 30 2001 12:27 3 18/22 q pp oe ei LOW VOLTAGE SWITCHGEAR _ | Report No: 2001003 YATRIKVETIC.AS, TEST REPORT Date : 27/02/2001 1. Verification of temperature-rise (sub-clause 8.3.3.1) Test conditions. Rated current A 400 Supply source Single phase Frequency (Hz) 50 fi Test current (A) 400 1 Test connection PVC insulated Copper conductors Number : 1 Same as test Size : 240 mm? conditions Length of connection from Terminal to terminal =2 m. Test duration (h) 8 (max) Ambient alr temp during the (°C) ms #10 to#40, Use of enclosure - 1.2. Test Results Rated current Exemal | Measured | Temp, Rise] Temp. Rise limit (A) connection | temp. (°C) (K) * _(K) Top. R ” 50 Side s 78 57 80 Termthals T 80 59 400 Bottom R 6 48 Side s 70 49 80 Terminals ii 75 54 x pene Metal 45 24 25 | Handle [06 35 L Contact Note Note : Limited solely by the necessity of not causing any damage to insulating materials. 4 ‘Laboratory Technician : if oratory Engineer: Confirmation: r— {brahim SAHIN Le Cae ZA Ismail TASCL Torahim AYRE Fam Norioifiie TAT Darton? Cally Anand, COD Te av. No: 00, 29/2 fp Poe ami LOW VOLTAGE SWITCHGEAR _ | Report No: 2001008 WIRMYETCAS. TEST REPORT Date :27/02 /2001 TEST REPORT SUBJECT : LOAD BREAK SWITCH-FUSE TYPE : FSF 630 LOAD BREAK SWITCH SERIALNO —_: FS06300004000860 CONTENT OF TEST : Type and Routine tests. Ue : 400 V AC (Rated ope. volt) TESTED IN ACCORDANCE WITH IEC 60947-3 TEST PLACE : FEDERAL ELEKTRIK YATIRIM VE TIC. AS. REPORT ISSUED + L.SAHIN 7 TESTED BY 2H. BOZTAS No Of pages 14 Laboratory, Technician Laboratory Engineer : Confirmation: © 1 SaHiN | LTASCL i cos Form No: 10.1F3ia , ‘caRaOREARIOAaE ~~ Biseibution: Quality Atsurans, MOGB Tet Rew, No: 00 29/2 _ ~ - : ¢ Mp FEDERAL ELERTRIK | LOW VOLTAGE SWITCHGEAR | Report No: 2001008 YAMRMYETIC AS. TEST REPORT Date :27/02 /2001 TEST REPORT SUBJECT : LOAD BREAK SWITCH-FUSE TYPE : FSF 630 LOAD BREAK SWITCH SERIALNO —_: FS06300004000960 CONTENT OF TEST : Type and Routine tests. Ue : 400 V AC (Rated ope. volt) TESTED IN ACCORDANCE WITH IEC 60947-3 TEST PLACE : FEDERAL ELEKTRIK YATIRIM VE TIC. AS. REPORT ISSUED +1 SAHIN. a TESTED BY 2H. BOZTAS No Of pages 24 Laboratory, Technician: Laboratory Engineer : Confirmation: © 1 SAHIN a LTASCL in = Sea iasiaioar Gully Asse MOC Ta i - 2ajed 49 FEDERAL ELERTRIK | LOW VOLTAGE SWITCHGEAR | Report No: 2001004 YOM EAS TEST REPORT Date : 27/02/2001 1. Ratings and specifications Type designation FSF630 Number of poles 3 Rated ope. Voltage. Uy v_ [400 Rated ope. Current le A_|630 Rated insulation Voltage U: v_|1000 Rated frequency Hz [40-60 Rated short circuit Bre, Cap. Using fuses | kA |100 Electrical Life ope. | 1000 Mechanical Life ope. |8000 Drive Manual ope. Fuses used and max. power loss w jas > Type of fuse NH3 Sub. Clause 4. Temperature rise, 8.3.3.1 &). 2, Dielectric properties 8.3.3.2 Type Test = : 3. Making and breaking cap. 8.3.3.3 ‘ 4. Dielectric verification 8.3.3.4 } 5. Temp.-tise verification 8.3.3.6 Routine | 1. Mechanical ope. Test 8.4.2. ®) Test {2. Resistance control (x) (0X) indicated test carried out. Note : for these test see attached sheet. Laboratory a 1SAHIN Laboratory Engineer © Confivmation: 7 LTASCT = LAYDIN SS Weake wie Caan ‘issibaloa” Qually Asorande MCB Tax FEDERAL EKTRAI TEL NO. 1 2o01 12 sz a FEDERAL ELEKTRIK LOW VOLTAGE SWITCHGEAR SATBOAYETICAS. TEST REPORT Date : 27/02/2001 Report No : 2001004 1. Verification of temperature-rise (sub-clause 8.3.3.1) Test conditions. Rated current A 630 Supply source Single phase Frequency (Hz) 50 Test current (A) 630 Test connection PVC insulated Copper conductors Number: 4 Same as test Size } 2x185 mm? conditions Length of connection from Terminal to terminal =2 m. Test duration (h) ces 8 (max) Ambient air temp during the (°C) 21°C, +10 tor40 Use of enclosure No : 1.2, Test Results Rated current Extemal | Measured [ Temp. Rise | Temp. Rise limit @) connection | temp. (°C) | _(K) - Top. R 61 40 Side s ~ 64 43 80 Terminals - 67 46 630 Bottom R 54 38 Side 8 56 36 80 ; Terminals T 59 38 Le Metal 51 30 25 Handle non-metal 63 32 35 Contact| Note Form Nov Iolite Rey. NO? 00 Laboratory Technician Torahim $AHIN Ismail TASCL Note : Limited solely by the necessity of not causing any damage to insulating materials. Confirmation: Torahim A aR Disibaten? Qualy Aste, MOGE Tet FEDERALELEKTEIK a = — ~ Phy FEDERAL LESTE | LOW VOLTAGE SWITCHGEAR _ | Repo" No:2001 NATRMYE Tk.A$. TEST REPORT Date . .27 02/2001 2. Tests of dielectric properties (8.2.3.3) Test conditions. Rated current (Ay 630 IEC Rated insulation 1000 © Requirement Voltage : UI M seen Frequency of Supply [Source (Hz) 50 45-62 Hz. [Test voltage ”) 3500 3500 V. Test duration 1 min tmin ')- With the LVS In the closa postion. i) Between all live parts ofall poles connected together. , i) Rand the frame of the LVS : it) Between each pol and al he other poles connected to the frame of the circuit breaker fi )- In the open position and in the tripped Same as test position conditions i) Between al lve parts ofall poles connected together and the frame of the LVS ji) Between the terminals of on side ~ connected togethor and the terminals ofthe other side connected together. 3.2.2. Test Results Test Test Test Test a) i a) iit b) i b) ii Positive | ¥__|Positive | [Positive | V [Positive | ¥ Negative | Negative Negative Negative Laboratory Technician : Laboratory Engineer : LSAHIN J 1. TASC raraNor TOR CaFOEARTT Diaibation! Gually Asurace CCB To Rev No:00

You might also like