Vendor has to supply: -

 Equipment lifetime.
 Engineering documentation.
 Vendor is responsible for any other parts to be done by other manufacturers.
 Detailed scope of supply.
 Layout of package(s) within package allowable space.
 Package turndown
 Sub-supplier list.
 All equipment special tools required for maintenance and overhaul.
 Complete client data sheets
 Design, engineer, fabricate, test and supply this package.
 Pre-commissioning, commissioning and start-up spare parts for pumps/engine controllers.
 Separate quotation for 2 years spare parts.
 P&ID's and documentation: Includes installation, operation and maintenance manual.
 Inspection & Testing.
 Instrumentation & Accessories:-
- The supplied instruments should be available for 10 years.
- Fiber / Nylon explosion proof cable glands to be used.
- All insulation materials shall be flame retardant, low halogen content.
- 316 St.St cable tray.
- St.St. fitting (Compression type).
- 316 St.St. instrument air tubing.
- Instrument air tubing header & branches.
- SDV's shall have 2 solenoid valves and automatic reset, SDV's valves 12" and over shall
have double acting actuator and fail false.
- All field instrument cables shall have steel wires with flame retardant.
- Solenoid valves shall be explosion proof.
- All electronic field instrumentation shall be covered with polyester for protections from
direct sun radiation.
- Control valves shall be low emission valve stem.
-
Steel Structure & Accessories: -
- Baseplates : Rigid self-supporting type.
- Ladders : Painted steel or galvanized steel.
- Platforms : Covered by galvanized grating.
- Handrails : Painted steel or galvanized steel.
- Pipe supports : Painted steel or galvanized steel.
- Walkways : Galvanized steel.
- Grating : Galvanized steel.

Piping & Accessories: -


- Gaskets : Asbestos free, spiral wound, metallic spiral wound.
- Piping : Material & wall thickness by vendor.
- Valves
- Fittings
- Bolting.
Electrical & Accessories: -
- Power distribution board(s)
- Electrical cables.
- Grounding : No. of grounding bosses is tow minimum.
: 95 mm2 routed on the main cable support system.
: Grounding cable to be high conductivity copper
PVC insulation.
- Lighting material : Normal lighting 150 watt, high pressure sodium or
metal halide.
: Emergency lighting is fluorescent type 2x40 watt
with built in Nickel Cadmium battery with back up
time of 2 hrs.
- Cable glands.
- Fittings…etc.
- Junction box(s)
- Cable tray : Heavy duty hot dip galvanized steel.

All electric motors : To be explosion proof.

External protective coating : Will be sandblasted and coated with 3 coats.

Hydraulic test : 1.5 times the max. working pressure for 1hr.

Drivers : 1- To be certified for the use in hazardous area


: 2- To be (non - sparking) explosion pro