Professional Documents
Culture Documents
Circuit function T
Technical data
Power consumption Response times
Orifice Power consumption Orifice Response times AC and DC
[mm] Inrush AC Hold AC (hot coil) DC hot / cold coil
[VA] [VA] [W] [W] [mm] Opening [ms] Closing [ms]
1.5 … 2.5 24 17 8 8/9 1.5 10 … 15 15 … 20
2.0 10 … 15 15 … 20
2.5 15 … 20 10 … 22
Response times [ms]:
Measured at valve outlet at 6 bar and + 20 ºC.
Opening: Pressure build-up 0 … 90 %, to
Closing: Pressure relief 100 … 10 %
Materials
2/21
6014
Dimensions [mm]
**
12 27
10 G1/8 18
24
32
11.2
3.7
6.3
15
7
9
41
15
C
5.6
C
5.4
M4
4x ***
4x8 deep
A * 8
B
24 32.6
32
35
Dimensions [mm]
Version A B C
SW14
24
3/21
6014
1(P) 3(R)
1(P) 3(R)
1(P) 3(R)
1(P) 3(R)
1)
Measured at + 20 °C, 1 bar2) pressure difference
2)
Measured as overpressure to the atmospheric pressure
4/21
6014
Brass body
C 3/2 way valve NC 1.5 0.07 0 … 16 8 126154 126155 125366
2(A)
2.0 0.11 0 … 10 8 125367 125368 125370
1(P) 3(R)
1(P) 3(R)
1(P) 3(R)
1(P) 3(R)
1)
Measured at + 20 °C, 1 bar2) pressure difference
2)
Measured as overpressure to the atmospheric pressure
5/21
6014
Earth terminal
The polarity is labelled on the valve
- switch ON +
1 2 + switch OFF -
Note: Only cable plug without circuitry should be used together with impulse version!
6/21
6014
11 O-Ring FKM
12 Pressure connection P
13 Pressure connection A
14 Screw CuZn / 1.4301
15 Seal Usit ring (Aluminium/NBR )
16 O-Ring NBR
7/21
6014
45 bei 2 W
51 bei 8 W
32 bei 2 W
40 bei 8 W G1/8
11,7
55,4
A SW19
P
G
10
31
M G1/4
L 45
G M L
G⅛ 10 51
G¼ 12 54
51 29
40
G 1/8
11.5
57.5
89
SW 19
A
P
G 1/4
20
10
11 G 1/8 16
69
32
8/21
6014
Please note that the cable plug has to be ordered separately, see separate datasheet for Type 2508.
x on request
9/21
6014
Seal: FKM
Sub-base: Stainless steel
(surface finish thick film passivated) Valve body: Brass
Stainless steel1.4301
Stainless steel 1.4305 (G 1/8”)
Stainless steel 1.4401 (G 1/4”)
Spring: 1.4310
10/21
6014
G1/8 F
24
7
41
74
63
5.4
C
C
H A 4x
B M4 x 8 deep
D 24
M4
5.6
32
35
SW14
24
E
24
11/21
6014
6014 valve, Ex m II T4, with FKM seal material and threaded connection with 3 m moulded cable approved
for single mounting, ambient temperature from - 10 °C to + 55 °C
Article no. Article no.
Port KV value Pressure Effective Voltage/
Orifice Body without with
Circuit function connec- water range coil power frequency
[mm] material manual manual
tion [m3/h] [bar] [W] [V/Hz]
override override
C 3/2 way valve 2.0 G⅛ 0.11 0 … 10 Brass 9 024/UC 278637 278645
NC 230/UC 278638 278646
Stainless 9 024/UC 278660 x
steel 230/UC 278661 x
2(A) G¼ 0.11 0 … 10 Brass 9 024/UC 278639 278647
230/UC 278641 278649
1(P) 3(R) Stainless 9 024/UC 278662 x
steel 230/UC 278663 x
2.5 G⅛ 0.16 0 … 6 Brass 9 024/UC x x
230/UC x x
G¼ 0.16 0 … 6 Brass 9 024/UC 278643 278673
230/UC 278644 x
T 3/2 way 1.5 G⅛ 0.07 0 … 7 Brass 9 024/UC 278650 x
Universal valve 230/UC x x
Stainless 9 024/UC 278664 x
2(A) steel 230/UC 278665 x
G¼ 0.07 0 … 7 Brass 9 024/UC x x
1(P) 3(R) 230/UC x x
Stainless 9 024/UC 278666 x
steel 230/UC x x
x on request
The maximum fluid temperature must not in any case exceed the permissible temperature class (T4 135 °C, 100 °C T5, T6 85 °C), minus 5 K.
ATEX and IECEx approval for coils with fixed cable outlet
ATEX: PTB 14 ATEX 2023 X IECEx: IECEx PTB 14.0049 X
II 2G Ex mb IIC T4 Gb Ex mb IIC T4 Gb
II 2D Ex mb IIIC T135 ºC Db Ex mb IIIC T135 ºC Db
12/21
6014
Stopper: 1.4105
13/21
6014
J I
68
G1/8
41.3
73.6
62.2
5.4
C
4x M4x8 deep
H A
B
24
D
32
35
51
24
E
14
SW
24
Dimensions [mm]
Version A B C D H
Threaded G⅛ 32 20.8 32.6 8
G¼ 46 26.8 49 12
Flange – 32 14.3 32.6 –
14/21
6014
x on request
6014 valve, Ex m II T4, with seal material FKM and threaded connection with junction box only for single
mounting available, ambient temperature form - 10 °C to + 55 °C
Article no. Article no.
Port KV value Pressure Coil Voltage/
Circuit Orifice Body without with
connec- water range effective Frequency
function [mm] material manual manual
tion [m3/h] [bar] power [V/Hz]
override override
C 3/2 way valve 2.0 G⅛ 0.11 0 … 10 Brass 9 024/UC 288470 288491
NC 230/UC 288490 288566
Stainless 9 024/UC 288488 x
steel 230/UC 288497 x
2(A) G¼ 0.11 0 … 10 Brass 9 024/UC 288471 288475
230/UC 288516 288519
1(P) 3(R) Stainless 9 024/UC 288486 x
steel 230/UC 288500 x
2.5 G⅛ 0.16 0 … 6 Brass 9 024/UC 288572 x
230/UC 288505 x
G¼ 0.16 0 … 6 Brass 9 024/UC 288498 288476
230/UC 288575 288479
T 3/2 way 1.5 G⅛ 0.07 0 … 7 Brass 9 024/UC 288511 x
Universal valve 230/UC x x
Stainless 9 024/UC x x
2(A) steel 230/UC x x
G¼ 0.07 0 … 7 Brass 9 024/UC x x
1(P) 3(R) 230/UC x x
Stainless 9 024/UC 288489 x
steel 230/UC 288506 x
x on request
The maximum fluid temperature must not in any case exceed the permissible temperature class (T4 135 °C, 100 °C T5, T6 85 °C), minus 5 K.
ATEX and IECEx approval for the assembly of the coil and the junction box
ATEX: EPS 16 ATEX 1046 X IECEx: IECEx EPS 16.0021 X
II 2G Ex eb mb IIC T4 Gb Ex eb mb IIC T4 Gb
II 2D Ex mb tb IIIC T130 ºC Db Ex mb tb IIIC T130 ºC Db
15/21
6014
Ex-Cable glands
(polyamide version included in delivery / surcharge applied for brass nickel plated version
Descrip- Ex Approvals Article
Photo Drawing
tion Certification Identification no
TL 29 … 37 mm
Brass.
L 6 mm
nickel- PTB 04 ATEX 1112 X, II 2 G Ex e IIC Gb,
plated, IECEx PTB 13.0027X II 2 D Ex tb IIIC Db IP68, 773278 D 20
6 … 13 mm SW 24 mm
E 27 mm
TL 36 … 45 mm
Polyamide, PTB 13 ATEX 1015 X, II 2 G Ex e IIC Gb, L 10 mm
7 … 13 mm IECEx PTB 13.0034X II 2 D Ex tb IIIC Db IP68 773277 D 20
SW 24 mm
E 28 mm
16/21
6014
Spring: 1.4310
17/21
6014
12
G1/8 27
10
18
24
32
11.2
6.3
3.7
15.1
7
14.5 9
41.4
5.4
20.8
23.3
4x A
6.5
8
M4x8 deep
24 M4
32
32
32.6
35
27.5
SW14
24
40
29 51
Electrical data
+ ≥ 30 mA
+
Barrier/
PLC 24 V DC Isolation > 9.3 V DC
module
–
Note: The valve is designed to operate on 24 V DC outputs through an intermediary intrinsically safe apparatus (isolating block or barrier)..
Function values for switching valve Max. allowable values acc. to the
at + 20 °C at + 55 °C certificate of conformity
Minimum switching cur- 30 mA 30 mA Ui 28 V
rent li 120 mA
Nominal resistance coil 310 Ω 360 Ω Pi 1.1 W
Minimum terminal voltage 9.3 V 10.8 V Ambient temperature + 60 ºC at T6
+ 75 ºC at T5
18/21
6014
C 3/2 way valve 0.9 30 Vac. to 10 Stainless Bürkert sub-base (SFB) 144540
NC 2(A) steel G⅛ 147226
Brass Bürkert sub-base (SFB) 147227
1(P) 3(R) G⅛ 146214
The maximum fluid temperature must not in any case exceed the permissible temperature class (T4 135 °C, 100 °C T5, T6 85 °C), minus 5 K.
Explosion-proof approvals
ATEX: PTB 01 ATEX 2101 0102 PTB IECEX12.0040
II 2G Ex i IIC T6 Gb Ex ia IIC T6 Gb
II 2D Ex i IIIC T85 ºC Db Ex ia IIC T80 °C Db
Voltage / fre-
Circuit Article no.
quency
19/21
6014
Manifold mounting
With manifold mounting, please comply with the permissible
duty cycle (5 W models with 100 % continuous rating or 8 W
model with 60 % duty cycle). The pressure port for the manifold
is
designated with P (R), and the outlet port with A (B). Only con-
nect together ports with the same designation.
20/21
6014
Fixing screw
Voltage/
Circuitry Article no.
Frequency
Flat seal
BN Cable
Article no.
length
[in mm]
[mm]
BU
12000 260893
5000 260892
GNYE
3000 260891
300 260890
Materials Approvals
Epoxy coil according to Form A ATEX, UL, CSA
Seal material EPDM Additional
Voltage Orifice: 1.2 mm, 3.0 mm
Non-standard voltages
Port connection
With banjo nut
To find your nearest Bürkert facility, click on the orange box www.burkert.com
21/21