Concrete Anchors.: Engineered For Every Job!
Concrete Anchors.: Engineered For Every Job!
Specialty Anchors
Fall Arrest Anchoring – Safety Ring Anchor System 49
29
Performance Figures
Please note that the performance of anchors into load situations please consult a qualified engineer or The graphs provided for each anchor are intended
concrete and other masonry materials is significantly the Ramset™ Technical Advisory Service for advice. to give an indication of the improvement possible.
affected by the specific installation conditions it is For exact prediction of performance in greater
subjected to. It is also important to note that to achieve these loads: embedment refer to the Ramset™ “Specifiers
(i) that the anchors must be installed a minimum Anchoring Resource Book” or software.
Over many years Ramset™ has, and continues to, of 4 x the hole depth for mechanical anchors
carry out research into the performance of anchors and 1 x the hole depth for chemical anchors, Ramset™ anchors can be used for a wide range of
into concrete and develop new improved anchors. away from the nearest concrete edge. applications and substrate materials outside the
(ii) that the anchors must be spaced a minimum of parameters we have assumed for this presentation.
The concrete (or other substrate) strength, the 4 x the hole depth for mechanical anchors and We recommend an appropriately qualified engineer
distance away from the edge of the concrete or other 1.5 x hole depth for chemical anchors, apart or the Ramset™ Technical Advisory Service be
anchors, the depth embedded into the substrate, the from each other. consulted to ensure the appropriate anchor is
exact hole size, the tightening torque used and the (iii) the thickness of the concrete structure being selected for specific applications outside the above
direction of the load, will all affect the performance fixed to, is a minimum of 2 x the hole depth. parameters, as Ramset™ provides a complete suite
to a greater or lesser degree. of tools to enable professional engineers to predict
Conditions outside these situations may affect the anchor performance under a wide range of
The performance figures presented for anchors in performance of the anchors significantly. application conditions.
this section are calculated using working load limit
principles for a specific concrete strength of 32 MPa It is possible in many cases to increase the These tools include information, both design software
(unless otherwise stated) and assuming either a performance of a particular size anchor by increasing and design manuals, to enable engineers to carry out
3 straight tension load or a straight shear load away its depth into the concrete.
from the concrete edge, is applied. For combined
design work using strength limit state principles in
accordance with Australian Design Standards.
30
™
Ramset Anchor Installation
To ensure the best results from your Ramset™ Anchor, full technical data sheets on anchor installation are available
from our website www.ramset.com.au. A summary of these recommendations is provided here for assistance.
1. Typical Hole Preparation
Drill hole using correctly Clean hole with correctly Remove debris, dust etc.
sized R3 PLUS or R3 MAX sized hole cleaning brush from the hole using a hole
bit to the specified depth in with stiff nylon or wire cleaning blower with at
solid substrate. bristles. Using a combination least 4 swift pumps.
push/pull and twisting Alternatively, a strong blast
(rotation) motion, ensure the
sides of the hole are
of clean, oil free compressed
air may be used.
3
scrubbed at least 3 times for
full depth of hole.
2. Anchor Installation
EXPANSION ANCHORS BOA™ COIL CHEMICAL ANCHORS DROP IN ANCHORS
EXPANSION ANCHORS
Insert anchor into hole Insert the assembled Boa™ a) Insert correct sized b) Drive stud to bottom of Insert anchor and push to
flush against fixture. Coil Expansion Anchor. ChemSet™ capsule or hole. Do not move the stud required depth. Using the
(The coil tab points up the inject ChemSet™ adhesive, while ChemSet™ is curing. special setting tool, drive the
anchor.) Tap anchor down to without creating air pockets, See Technical Data for expander plug down until
depth set mark and stop. into hole. setting times. shoulder of the setting punch
meets top of the anchor.
3. Securing the Fixture
EXPANSION ANCHORS BOA™ COIL CHEMICAL ANCHORS DROP IN ANCHORS
EXPANSION ANCHORS
Tighten with a spanner. Wind the anchor down until Attach fixture and tighten Position fixture then insert
For optimum anchor the washer is firmly held to nut in accordance with the bolt and tighten with
performance use a torque the fixture and stop. Ensure recommended tightening spanner.
wrench. washer is a tight snug fit. torque.
31
™
Ramset Anchor Selection Guide
The following chart provides a quick guide for selecting the appropriate Ramset™ Concrete Anchor to suit your needs.
Please refer to page 4 for the Legend of Symbols for a detailed explanation of the symbols used.
EpoxyPutty ✓ ✓ ✓ ✓ ✓ ✓ ✓
EpoxyPatch ✓ ✓ ✓ ✓ ✓ ✓ ✓
EpoxyGrout ✓ ✓ ✓ ✓ ✓ ✓ ✓
Safety Ring Anchor System ✓ ✓ ✓ ✓ ✓ ✓ ✓
Concrete Nail
32
INSTALLATION RELATED
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓
✓
✓
✓
✓ ✓ ✓
✓
✓
✓
✓
✓
✓
✓
3
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
33
SpaTec™ Safety Anchors 80
TENSILE WORKING LOAD LIMIT
SpaTec™ Safety Anchors are a heavy duty torque
70
Structural Anchors 15
TENSILE WORKING LOAD LIMIT
Manufactured from grade 8.8 steel, a torque controlled
structural anchor with “pull-down” action specifically
Working Load Limit (kN)
14
designed for high shear load applications. Its unique,
13
easily visible coloured head allows inspecting engineers
to quickly identify that the specified anchor was used. 12
11
16
10 20
9
60 70 80 90 100
Embedment Depth (mm)
INSTALLATION TORQUE RECOMMENDATIONS
All values in Nm d Anchor Size
16 20
Zinc 115 210
ANCHOR RANGE
d Anchor L Anchor t For Fixtures db Thread Size do Hole ø df Fixture Hole ø Rec. Working Load kN Order No. Pack
Size Length Up To x (mm) 32 MPa Quantity
(mm) (mm) (mm) hL Hole Depth Tensile* Shear*
(mm)
16 90 10 M12 16 x 95 19 9.7 16.7 HS16090H 10
100 19 M12 16 x 105 19 9.7 16.7 HS16100H 10
20 100 10 M16 20 x 110 24 13.6 31.1 HS20100H 10
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
34
Boa™ Coil Expansion Anchors 30
TENSILE WORKING LOAD LIMIT
High strength, removable expansion type
6.5
10
5
0
0 30 60 90 120 150
Embedment Depth (mm)
ANCHOR RANGE
d Anchor L Anchor t For Fixtures do Hole ø df Fixture Tight Rec. Working Load kN Complete Pack Tab Only Pack
Size Length Up To x Hole ø Torque 32 MPa Anchor Quantity Order No. Quantity
(mm) (mm) (mm) hL Hole Depth (mm) Tensile* Shear* Order No.
5/8”/16
140
90
125
70
12
40
13 x 125
16 x 105
16 x 130
16
19
19
5 turns
5 turns
5 turns
8.7
11.6
13.2
10.7
16.2
18.5
BAC08140
BAC10090
BAC10125
25
25
25
BAC08
BAC10
BAC10
100
50
50
3
3/4”/19 85 6 19 x 105 21 5 turns 14.0 20.2 BAC12085 20 BAC12 50
115 25 19 x 120 21 5 turns 16.3 23.6 BAC12115 20 BAC12 50
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
10
0
0 50 100 150 200
Embedment Depth (mm)
INSTALLATION TORQUE RECOMMENDATIONS
All values in Nm d Anchor Size
6 8 10 12 16 20 24
Zinc 10 20 35 50 130 295 460
Galvanised – 20 35 50 130 295 –
Stainless Steel 5 20 35 50 155 355 –
ANCHOR RANGE
d Anchor L Anchor t For Fixtures db Thread Size do Hole ø df Fixture Rec. Working Load kN Order No. Pack
Size Length Up To x x Hole ø 32 MPa Quantity
(mm) (mm) (mm) Lt Thread Length hL Hole Depth (mm) Tensile* Shear* A2
304
(mm) (mm)
6 45 5 M6 x 20 6 x 50 8 2.2 2.8 – – T06045SS 100
55 15 M6 x 30 6 x 55 8 2.2 2.8 T06055 – T06055SS 100
85 45 M6 x 60 6 x 55 8 2.2 2.8 T06085 – T06085SS 100
120 80 M6 x 95 6 x 45 8 2.2 2.8 T06120 – – 50
8 50 6 M8 x 20 8 x 60 10 2.2 4.9 T08050 – T08050SS 100
65 12 M8 x 35 8 x 65 10 3.4 4.9 T08065 – T08065SS◆ 50
90 40 M8 x 60 8 x 75 10 3.4 4.9 T08090 – T08090SS 50
130 80 M8 x 85 8 x 100 10 3.4 4.9 – – T08130SS 50
10 65 6 M10 x 30 10 x 75 12 4.0 6.8 T10065 – T10065SS 50
75 12 M10 x 40 10 x 80 12 4.7 6.8 T10075 – T10075SS 50
90 30 M10 x 55 10 x 90 12 4.7 6.8 T10090 T10090GH T10090SS 50
120 50 M10 x 85 10 x 100 12 4.7 6.8 T10120 – T10120SS 20
Continued on next page. ◆ T08065SS pack quantity is 100.
35
TruBolt™ Stud Anchor range cont.
d Anchor L Anchor t For Fixtures db Thread Size do Hole ø df Fixture Rec. Working Load kN Order No. Pack
Size Length Up To x x Hole ø 32 MPa Quantity
(mm) (mm) (mm) Lt Thread Length hL Hole Depth (mm) Tensile* Shear*
(mm) (mm)
12 80 6 M12 x 35 12 x 90 15 5.6 8.6 T12080 T12080GH T12080SS 20
100 25 M12 x 50 12 x 105 15 6.2 8.6 T12100 T12100GH T12100SS 20
120 45 M12 x 70 12 x 105 15 6.2 8.6 T12120 – – 20
140 65 M12 x 80 12 x 105 15 6.2 8.6 T12140 T12140GH T12140SS 20
180 100 M12 x 80 12 x 125 15 6.2 8.6 T12180 T12180GH T12180SS 20
16 100 8 M16 x 45 16 x 115 19 7.0 14.4 T16100 T16100GH T16100SS 20
125 20 M16 x 65 16 x 135 19 9.5 14.4 T16125 T16125GH T16125SS 20
150 45 M16 x 85 16 x 145 19 9.5 14.4 T16150 T16150GH T16150SS 20
175 70 M16 x 85 16 x 145 19 9.5 14.4 T16175 T16175GH T16175SS 20
220 115 M16 x 85 16 x 165 19 9.5 14.4 T16220 – – 20
20 120 10 M20 x 50 20 x 140 24 9.8 22.3 T20120 T20120GH T20120SS 10
160 35 M20 x 50 20 x 170 24 13.3 22.3 T20160 T20160GH T20160SS 10
215 90 M20 x 50 20 x 200 24 13.3 22.3 T20215 T20215GH – 10
24 175 35 M24 x 65 24 x 200 28 14.3 39.4 T24175 – – 5
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
Anchor setting
ANCHOR RANGE
d Anchor Size L Anchor Length do Hole ø (mm) Rec. Working Load kN Order No. Pack
(mm) (mm) x 32 MPa Quantity
hL Hole Depth (mm) Tensile*
6 55 6 x 45 1.4 TFE06 100
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
36
AnkaScrew™ Screw In Anchors 12
TENSILE WORKING LOAD LIMIT
An all steel, screw-in, non expansion, removable
anchor for fast and simple anchoring into solid
ANCHOR RANGE
d Anchor L Anchor t For Fixtures db Thread do Hole ø df Fixture Rec. Working Load kN Order No. Pack
Size Length Up To Size x Hole ø 32 MPa A2 Quantity
(mm) (mm) (mm) hL Hole Depth (mm) Tensile Shear 304
(mm)
8 45 15 M6 8 x 55 10 2.7 2.97 DP08045H DP08045HSS100
70 32 M6 8 x 65 10 4.2 2.97 DP08070H DP08070HSS 50
95 60 M6 8 x 70 10 4.2 2.97 DP08095H – 50
10 45 8 M8 10 x 55 12 3.8 5.6 DP10045H DP10045HSS 50
55 20 M8 10 x 55 12 3.8 5.6 DP10055H – 50
60 20 M8 10 x 60 12 4.8 5.6 – DP10060HSS 50
80 30 M8 10 x 80 12 5.9 5.6 DP10080H DP10080HSS 50
105 60 M8 10 x 85 12 5.9 5.6 DP10105H DP10105HSS 25
12 65 15 M10 12 x 75 15 6.3 8.9 DP12065H - 25
75 20 M10 12 x 75 15 7.7 8.9 DP12075H DP12075HSS 25
110 50 M10 12 x 95 15 7.7 8.9 DP12105H - 20
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
37
DynaBolt™ Sleeve Anchors 25
TENSILE WORKING LOAD LIMIT
Our patented design sleeve anchor with the
unique ability to “pull-down” and ensure a tight
ANCHOR RANGE
d Anchor L Anchor t For Fixtures db Thread Size do Hole ø df Fixture Rec. Working Load kN Order No. Pack
Size Length Up To x Hole ø 32 MPa A2 Quantity
(mm)
6 26 3 M4.5 6 x 30 8 1.8 2.5 D6026 – –
38 12 M4.5 6 x 45 8 2.7 2.5 DP06040 – DP06040SS 100
57 30 M4.5 6 x 55 8 2.7 2.5 DP06060 – DP06060SS 100
8 40 6 M6 8 x 50 10 3.4 4.0 DP08040 – DP08040SS 100
66 25 M6 8 x 65 10 4.2 4.0 DP08065 – DP08065SS 50
92 50 M6 8 x 75 10 4.2 4.0 DP08090 – DP08090SS 50
10 41 3 M8 10 x 50 12 3.8 6.4 DP10040 DP10040GH – 50
49 20 M8 10 x 55 12 3.8 6.4 DP10050 DP10050GH DP10050SS 50
76 30 M8 10 x 65 12 5.9 6.4 DP10075 DP10075GH DP10075SS 50
103 50 M8 10 x 80 12 5.9 6.4 DP10100 DP10100GH DP10100SS 25
124 80 M8 10 x 85 12 5.9 6.4 DP10125 – – 25
12 55 10 M10 12 x 70 15 6.3 7.9 DP12060 DP12060GH DP12060SS 25
70 15 M10 12 x 70 15 7.7 7.9 DP12070 DP12070GH DP12070SS 25
98 45 M10 12 x 95 15 7.7 7.9 DP12100 DP12100GH DP12100SS 20
126 70 M10 12 x 95 15 7.7 7.9 DP12125 DP12125GH DP12125SS 20
16 62 6 M12 16 x 80 19 7.7 10.5 DP16065 DP16065GH – 20
106 35 M12 16 x 120 19 11.9 10.5 DP16110 DP16110GH – 10
140 65 M12 16 x 120 19 11.9 10.5 DP16140 DP16140GH – 10
20 81 8 M16 20 x 100 24 10.8 15.6 DP20080 DP20080GH – 10
113 25 M16 20 x 125 24 16.6 15.6 DP20115 DP20115GH – 5
157 70 M16 20 x 155 24 16.6 15.6 DP20160 – – 5
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
Ask your Ramset™ Stockist or representative for DynaBolt™ Sleeve Anchor DynaBolt™ Sleeve Anchor Typical competitors
a demonstration. prior to tightening. tightened. product fully tightened.
Note: Note: Note:
• Typical gap from warp in • No gap. • Gap.
fixture plate, debris etc. • Controlled sleeve collapse. • No clamping.
• Fixture clamped to surface. • Sleeve cannot collapse.
38
DynaBolt™ Sleeve Anchors 5
TENSILE WORKING LOAD LIMIT
DECORATIVE HEAD
Component Sets
ANCHOR RANGE for use with Allthread Rod
d Anchor L Anchor/ db Thread Size do Hole ø df Fixture Bolt/ Recommended Order No. Pack
Size Post Screw x Hole ø Post Screw Working A2 Quantity
(mm) Length (mm) hL Hole Depth (mm) (mm) Style Load* (kg) 304
39
DynaSet™ Drop In Anchors
An all steel internally threaded anchor, giving
a permanent anchorage point in solid concrete,
brick or masonry. For use with machine bolts
and threaded rod. Flanged
Standard
Setting Tool
ANCHOR RANGE
d Anchor L Anchor db Thread Size do Hole ø Style Setting Rec. Working Load kN Order No. Pack
Size Length x x Tool 32 MPa A2 Quantity
Lt Thread Length hL Hole Depth Tensile* Shear* 304
ANCHOR RANGE
d Anchor L Anchor db Thread Size do Hole ø df Fixture Hole ø Rec. Working Load kN Order No. Pack
Size Length x 32 MPa Quantity
hL Hole Depth Tensile* Shear*
6 35 M6 13 x 40 8 2.2 1.3 RLM06 50
8 52 M8 16 x 60 10 4.0 2.4 RLM08 25
10 52 M10 16 x 60 12 5.6 3.8 RLM10 25
12 65 M12 22 x 70 15 8.0 5.5 RLM12 25
16 75 M16 26 x 80 19 10.1 10.2 RLM16 25
Note: Some sizes also available with imperial threads.
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
40
RediDrive™ Hammer In Anchors
One piece all steel hammer in anchor for permanent
tamper proof anchoring into solid concrete.
Mechanically galvanised finish.
ANCHOR RANGE
d Anchor L Anchor t For Fixtures do Hole ø Rec. Working Load kN Order No. Pack
Size Length Up To x 32 MPa Quantity
(mm) (mm) (mm) hL Hole Depth Tensile* Shear*
(mm)
5 20 1.6 5 x 32 1.8 2.7 RD05020 100
30 5.0 5 x 40 2.5 4.6 RD05030 100
40 15.0 5 x 47 2.5 4.6 RD05040 100
50 20.0 5 x 47 3.6 4.9 RD05050 100
65 35.0 5 x 57 3.6 4.9 RD05065 100
75 45.0 5 x 52 3.6 4.9 RD05075 100
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
ShureDrive™ Anchors
An all metal hammer in expansion anchor
providing a tamper proof anchor into solid
concrete and masonry.
3
ANCHOR RANGE
d Anchor L Anchor t For Fixtures dh Head ø do Hole ø df Fixture Rec. Working Load kN Order No. Pack
Size Length Up To x Hole ø 32 MPa A2
Quantity
(mm) (mm) (mm) hL Hole Depth (mm) Tensile* Shear* 304
(mm)
5 22 3 11 5 x 30 6 0.8 1.0 SDM05022 – 100
6 30 5 13 6 x 35 7 1.0 1.4 SDM06030 SDM06030SS100
50 25 13 6 x 55 7 1.0 1.4 SDM06050 – 100
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
RamPlug™ Anchors
Available in a variety of configurations, the
RamPlug™ Anchor provides a medium duty screw
anchoring point into concrete, hollow brick and for
light duty applications in lightweight concrete.
ANCHOR RANGE
STANDARD PLUGS for fixing to solid concrete and masonry materials
d Anchor L Anchor Screw Gauge do Hole ø Rec. Working Load kN Order No. Pack
Size Length x 32 MPa Quantity
(mm) (mm) hL Hole Depth Tensile* Shear
5 25 5-7 5 x 30 0.30 0.4 DNP05 100
6 30 6-9 6 x 40 0.50 0.8 DNP06 100
7 30 9 - 12 7 x 40 0.65 1.1 DNP07 100
8 40 10 - 14 8 x 50 0.80 1.3 DNP08 100
10 50 14 - 18 10 x 60 1.20 2.4 DNP10 50
12 60 18 - 24 12 x 75 1.80 3.0 DNP12 25
Note: These capacities are based on the use of a screw of the maximum size shown, complying with AS3566.1, and of sufficient length to achieve full engagement in the plug.
41
RamPlug™ Anchor range cont.
LONG PLUGS for fixing to hollow brick and blocks
d Anchor L Anchor Screw Gauge do Hole ø Rec. Working Load kN Order No. Pack
Size Length x 32 MPa Quantity
(mm) (mm) hL Hole Depth Tensile* Shear
6 60 6-9 6 x 70 0.35 0.8 DLP06 100
8 80 10 - 14 8 x 90 0.45 1.3 DLP08 100
10 80 14 - 18 10 x 90 0.55 2.4 DLP10 50
Note: These capacities are based on the use of a screw of the maximum size shown, complying with AS3566.1, and of sufficient length to achieve full engagement in the plug.
ANCHOR RANGE
d Anchor L Anchor t For Fixtures do Hole ø Rec. Working Load kN Order No. Pack
Size Length Up To x 32 MPa Mushroom Round Flat Countersunk Quantity
(mm) (mm) (mm) hL Hole Depth Tensile* Shear* Head Head Head Head
(mm)
5 20 2 5 x 25 0.20 0.50 TNM320 – – – 100
25 5 5 x 30 0.20 0.50 TNM325 ◆ TNR325 ◆ TNL325 – 100
33 6 5 x 40 0.20 0.50 – – ED05033 ◆ – 100
38 13 5 x 40 0.20 0.50 – TNR338 – – 100
50 20 5 x 45 0.20 0.50 – – ED05050 – 100
6 42 12 6 x 50 0.30 0.75 – – ED06042 – 100
55 25 6 x 50 0.30 0.75 – – ED06055 ◆ – 100
70 40 6 x 50 0.30 0.75 – – ED06075 ◆ – 100
6.5 25 5 6.5 x 30 0.30 0.80 TNM425 ◆ TNR425 – TNF425 100
38 13 6.5 x 40 0.30 0.80 TNM438 TNR438 – TNF438 100
50 25 6.5 x 45 0.30 0.80 TNM450 TNR450 – TNF450 100
75 50 6.5 x 55 0.30 0.80 TNM475 – – TNF475 50
8 75 30 8 x 80 0.40 1.00 – – ED08080 – 50
120 75 8 x 95 0.40 1.00 – – ED08120 – 50
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
◆ Available with stainless steel expansion nail. Add SS to end of Order No.
42
Plastic Spaghetti
◆ Light duty application.
◆ Economical simple fixing.
◆ Quick installation. Nail or screw in.
◆ Cut to required length.
Drill Size Nail Size Suits Screws Rec. Working Load kg Drill No. Order No.
(mm) (mm) 32 MPa 5 m Roll 50 m Roll
Tensile* Shear*
5 2.5 - 4 diameter 6-8g 4 30 529107 5 x 150 mm 463609 RSP
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
Colour Drill Size Screw Size Rec. Working Load kg Length Length Length Length Length
White
(mm)
5 4.5 - 6 4
Tensile
32 MPa
30
Shear Poly
25 mm
Frame
464224 WPWH25 –
32 mm
Frame
–
Poly
38 mm
Frame
WPWH38 –
Poly
50 mm
Frame
– –
100 m
Roll
3
Red 6 8-9 5 50 464286 WPRD25 WPRD32 464347 WPRD38 – WPRD50 720115
Green 7 10 - 12 10 70 464408 WPGR25 WPGR32 464460 WPGR38 464491 WPGR50 720122
Blue 8 14 - 16 45 130 – WPBU25 – – WPBU38 – WPBU50 720139
Note: These capacities are based on the use of a screw of the maximum size shown, complying with AS3566.1, and of sufficient length to achieve full engagement in the plug.
43
ChemSet™ Reo 502™ Anchoring Adhesive
A heavy duty chemical anchor for Grade 500N Rebar. Works in dry, Reo 502™
Working Time Cure Time
damp, wet and flooded holes with a fast cure time. (mins) (hrs)
32°C 8 2
Substate Temperature
27°C 12 2
20°C 15 2
16°C 18 3
10°C 21 6
0°C – –
Note: Cartridge temperature
minimum 15°C.
Note: Full technical data sheets covering performance, installation and limitations are available on request from your Ramset™ representative or from our web site www.ramset.com.au
15 20 mins
20°C
corrosive and damp environments when used in conjunction with 15°C 25 30 mins
galvanised or stainless steel studs into solid concrete or masonry 10°C
substrate and is suitable for overhead anchoring applications. 5°C 45 1
0°C
60 5
-5°C
ANCHOR RANGE
d Anchor Size do Drill Size Capsule ø Recommended Working Load kN Order No. Pack
x x 32 MPa Quantity
hL Hole Depth Capsule Length Tensile* Shear*
8 10 x 80 9.5 x 80 6.4 4.5 CHEM08 10
10 12 x 90 11.0 x 80 8.7 7.1 CHEM10 10
12 14 x 110 13.0 x 95 12.4 10.5 CHEM12 10
16 18 x 125 17.0 x 95 18.1 19.9 CHEM16 10
20 24 x 150 21.5 x 115 29.0 30.0 CHEM2024 6
24 26 x 160 21.5 x 115 33.5 43.4 CHEM2024 6
Note: Figures provided here are for the chemical anchoring material performance only. The final complete anchor performance will be dependent on the weakest component from the chemical
anchor and the fixing rod or stud. It is recommended the performance of the rod/stud used should also be carefully checked.
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
44
ChemSet™ Injection TENSILE WORKING LOAD LIMIT
800 Series Anchoring 801 802
80
Working Time Cure Time Working Time Cure Time
Adhesive 8
Substate Temperature
16
epoxy mortar, available in two 30°C 3 10 12 17 20
formulations: Fast cure for use in 25°C 4 12 20 20 40 24
20°C 6 14 25 23
temperate climates and a slow cure
10°C 40 24 90 33
for tropical climates or deep holes 5°C 75 36 120 66 20
where longer gel times are needed. Note: Cartridge temperature minimum 15°C.
0
0 50 100 150 200 250
Embedment Depth (mm)
Note: Full technical data sheets covering performance, installation and limitations are available on request from your Ramset™ representative or from our web site www.ramset.com.au
30 1
20°C
for the installation of deformed rebar or threaded studs into a 15°C 50 2
solid concrete or masonry substrate. 10°C
5°C 90 5
0°C
120 10
-5°C
ANCHOR RANGE
d Anchor Size do Drill Size Rec. Working Load kN Deform Rebar do Drill Size Rec. Working Load kN Capsule ø Order No. Pack
x 30 MPa Nominal Size Bar 32 MPa x Quantity
hL Hole Depth Tensile Shear Tensile* Shear* Capsule Length
10 12 x 90 8.7 7.1 – – 8.7 7.1 11 x 90 HAC10 10
12 14 x 110 12.4 10.5 12 15 12.4 10.5 13 x 110 HAC12 10
16 18 x 125 20.1 19.8 16 20 19.1 19.9 17 x 125 HAC16 10
Note: Figures provided here are for the chemical anchoring material performance only. The final complete anchor performance will be dependent on the weakest component from the chemical
anchor and the fixing rod or stud. It is recommended the performance of the rod/stud used should also be carefully checked.
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
Note: Full technical data sheets for ChemSet™ Maxima™ Spin Capsules and ChemSet™ Hammer Capsules covering performance, installation and limitations are available on request from your
Ramset™ representative or from our web site www.ramset.com.au
45
ChemSet™ Injection 101 50
TENSILE WORKING LOAD LIMIT
101
Anchoring Adhesive Working Time Cure Time
8
Substate Temperature
16
solid concrete and masonry or hollow 30°C 7 1
30 20
24
brick and concrete block. 20°C 10 1.5
20
5°C 30 5 10
0°C 40 7
Note: Cartridge temperature minimum 15°C.
0
0 50 100 150 200 250
Embedment Depth (mm)
PERFORMANCE DETAILS of ChemSet™ Injection 101 Anchoring Adhesive with Ramset™ Grade 5.8 ChemSet™ Studs and Grade 4.6 Threaded Rod
d Anchor Hole Depth Recommended Working Load kN 32 MPa
3 Size ChemSet™ 101 with
Grade 4.6 Threaded Rod
Tension* Shear* Tension*
ChemSet™ 101 with
Ramset™ Grade 5.8 ChemSet™ Studs
Shear*
8 80 4.5 3.6 4.5 4.5
10 90 6.0 5.8 6.0 7.1
12 110 8.6 8.4 8.6 10.5
16 125 13.5 15.6 13.5 19.9
20 150 22.3 24.3 22.3 30.0
24 160 32.7 35.0 32.7 43.4
*Refer to page 31 for details of installation recommendations and page 30 for explanation of the load data provided.
™
ChemSet Chemical Anchoring
IF IT’S NOT RAMSET™ — IT’S NOT ChemSet™
◆ High performance.
◆ Fast curing.
46
ChemSet™ INJECTION CONSUMABLES
Grade 4.6 ChemSet™ Injection Rod
An economical threaded rod, zinc plated or hot dipped
galvanised finish, suitable for use with ChemSet™
Injection 101 Anchoring Adhesive.
Zinc 30 75
Galvanised 30 75
ANCHOR RANGE
d Anchor L Anchor t For Fixtures do Drill Size (mm) Rec. Working Load kN Order No. Pack
Size Length Up To x Quantity
(mm) (mm) (mm) hL Hole Depth (mm) Tensile Shear
12 (M12) 160 30 14 x 110 15.3 8.4 CR12160 CR12160GH 20
16 (M16) 190 40 18 x 125 28.5 15.6 CR16190 CR16190GH 20
Note: For other sizes, or higher strengths use Ramset™ Grade 5.8 ChemSet™ Studs, see page 48.
Figures provided here are for the steel stud performance only. The final complete anchor performance will be dependent on the weakest component from the chemical
anchor and the fixing rod or stud. It is recommended the performance of the rod/stud used should also be carefully checked.
Sieve
Sleeve/Sieve do Drill Size To Suit Stud Suit All Thread Description Order No. Pack
Length Quantity
64 12 8 M8 Nylon Sleeve ISS08 100
64 14 10 M10 Nylon Sleeve ISS10 100
64 16 12 M12 Nylon Sleeve ISS12 100
1000 12 6/8 M8 Fine Metal Mesh Sieve ISM10 1
1000 16 10/12 M10/M12 Fine Metal Mesh Sieve ISM12 1
1000 22 16 M16 Fine Metal Mesh Sieve ISM16 1
Retaining Collars
◆ Retaining collars are used in overhead injection
applications, to retain the stud and ChemSet™
Injection Anchoring Adhesive in the hole until
gelling occurs.
Anchor Size To Suit Anchor Order No. Pack
Quantity
8 CS08110 ISR08 100
10 CS10130 ISR10 100
12 CS12160 ISR12 100
16 CS16190 ISR16 100
47
ChemSet™ CAPSULE CONSUMABLES
Grade 5.8 ChemSet™ Studs
A superior strength threaded stud, zinc plated, hot dipped galvanised
or 316 stainless steel, able to take full advantage of the capacity of the
adhesive bond achieved when used with ChemSet™ Maxima™ Spin
Capsules or ChemSet™ Injection Anchoring Adhesive.
INSTALLATION TORQUE RECOMMENDATIONS – GRADE 5.8 ChemSet™ STUDS
All values in Nm d Anchor Size
8 10 12 16 20 24
Zinc 10 20 40 95 180 315
Galvanised 10 20 40 95 180 315
Stainless Steel 10 20 40 95 180 315
ANCHOR RANGE
d Anchor L Anchor t For Fixtures do Drill Size (mm) Rec. Working Load kN Order No. Pack
Size Length Up To x A2
Quantity
(mm) (mm) (mm) hL Hole Depth (mm) Tensile Shear 304
3 16 (M16)
20 (M20)
24 (M24)
190
260
300
40
80
105
18 x 125
24 x 150
26 x 160
36.4
54.9
79.5
19.9
30.0
43.4
CS16190
CS20260
CS24300
CS16190GH
CS20260GH
CS24300GH
CS16190SS
CS20260SS
CS24300SS
10
6
6
Note: Figures provided here are for the steel stud performance only. The final complete anchor performance will be dependent on the weakest component from the chemical
anchor and the fixing rod or stud. It is recommended the performance of the rod/stud used should also be carefully checked.
48
EPOXY REPAIR COMPOUNDS
EpoxyPatch
Large Spiral LSMP
3
◆ Add fillers to create mortars.
◆ Grouting of starter bars. FILLERS
◆ Repair broken concrete. ◆ An inorganic pre blended mineral filler.
◆ Clean up tools, equipment and uncured ◆ Use for mixing with epoxy resin binders to
EpoxyPatch with Xylene. produce mortars of various consistencies.
◆ Carton quantity: 1 ◆ Carton quantity: 1
EpoxyGrout
◆ High performance pourable epoxy.
◆ Anchoring bolts, bars and fixing points.
◆ Suitable for use on damp substrate.
◆ Mix with fillers to create high strength grout.
◆ Clean up tools, equipment and uncured
EpoxyGrout with Xylene.
◆ Carton quantity: 1
49
3
TM
50
4 Ramset Fastening
Ramset™ supply a range of quality fasteners
™
Rivets
Truss Dome 52
Multi Grip/Snap Head 52
4
PLASTERBOARD FASTENERS
TOGGLEMATE™ AND WALLMATE™
◆ Self drilling.
◆ Self clamping of anchor.
◆ Screw can be replaced without losing anchor.
◆ All metal body.
Togglemate™ Wallmate™
Sg Screw Gauge SL Minimum Screw Length Wt Wall Thickness Wt Wall Thickness Pack
(mm) 5 - 10 mm 10 - 13 mm Quantity
6-7 20 Metal Body WMZ (0.10) Plastic body WM25 (0.10) 100
8 20 Metal body TM16 (0.20) 50
Note: Figures in brackets refer to Recommended Working Load (kN) in 10 mm plasterboard.
db Thread do Hole ø Wt Wall Thickness Wt Wall Thickness Wt Wall Thickness Wt Wall Thickness Wt Wall Thickness Wt Wall Thickness
Size (mm) 5 mm 6 - 10 mm 8 - 13 mm 6 - 16 mm 16 - 24 mm 34 - 38 mm
M4 8 HW05M4 (0.10) HW10M4 (0.11) HW13M4 (0.11) HW24M4 (0.15) HW38M4 (0.15)
M5 9 HW14M5 (0.18)
M6 13 HW16M6 (0.22)
Note: Figures in brackets refer to Recommended Working Load (kN) in 10 mm plasterboard.
51
RamToggle™
◆ Suitable for cavity and solid wall applications.
◆ Wide wing span for maximum holding power.
◆ Anti rotation fins.
◆ Nylon body is non-conductive.
◆ Pack quantity: 100 Style 1 Style 2
Style do Hole Diameter Sg Screw Gauge Wt Wall Thickness Wt Wall Thickness Wt Wall Thickness
(mm) 5 - 10 mm 8 - 12 mm 12 - 18 mm
Style 1 8 6-8 LP12 (6g = 0.09, 8g = 0.10)
Style 2 8 6-8 RT10 (0.11) RT12 (0.12) RT16 (0.12)
Note: Figures in brackets refer to Recommended Working Load (kN) in 10 mm plasterboard.
Spring Toggle
SL Screw Length do Hole Size db Screw Thread Size Round Countersunk Cup Hook Pack
(mm) (mm) Head Head Quantity
50 7/16" 1/8" STR04050 (0.10) 100
50 9/16" 3/16" STR05050 (0.13) STF05050 (0.13) STK05050* (0.13) 100
75 9/16" 3/16" STR05075 (0.13) STF05075 (0.13) 50
100 9/16" 3/16" STR05100 (0.13) 50
Note: Figures in brackets refer to Recommended Working Load (kN) in 10 mm plasterboard. * Pack quantity: 50
CLIPS
◆ For fast fixing of cables and pipes to steel structures.
Clip Flange Thickness Cable Diameter Cable Diameter Cable Diameter Cable Diameter Pack
6 - 10 mm 16 - 20 mm 25 - 32 mm 6 - 25 mm Quantity
Vertical Flange Clip 1.6 - 2.5 VF1 100
DynaClip 2.0 - 8.0 DK10 100
DynaClip 2.0 - 10.0 DK20 DK32 100
MultiClip™ RTCUV25 50
RIVETS
ALUMINIUM/STEEL/MULTI GRIP RIVETS
Grip Range Bd Body ø Head Type Multi Grip/Snap Head Aluminium/Steel Steel/Steel Pack
Order No. Order No. Order No. Quantity
1.6 - 3.2 3.2 Truss Dome RB42ASDO RSS42 1000
3.2 - 4.8 3.2 Truss Dome RB43ASDO RSS43 1000
4.8 - 6.4 3.2 Truss Dome RB44ASDO 1000
4.0 - 8.0 3.2 Snap Head RAS45M 1000
52