functionality, Comba NIX-41 is usually deployed in access layer of the network. NIX-41 supports friendly Web GUI and can work with B/S T-NMS to Product Features simplify network provisioning and monitoring, and 6-38GHz licensed bands meet the most stringent SLAs. ETSI channels: 7-56MHz, FCC 40MHz QoS supported 10-150 Mbps per radio carrier It can be deployed in mobile backhaul, private Integrated carrier-class Ethernet switch networks and last-mile access networks. Jumbo frame size up to 9600 bytes
Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. Page 1 of 3 All rights reserved. DS-Control:2-2-0/ 0414 Product Specification
Modulation QPSK, 8QAM, 16QAM, 32QAM Standard ITU-T G.703 compliance
Transmission Capacity Maximum 150Mbps per carrier ETH Service
LACP, STP, Flow Control, Broadcast
Feature Storm Control, IEEE Std 802.1X, ACL, Ports Mirroring, Ports Statistics, Shape Performance Frame Size Up to 9600 bytes System Configuration* 1+0 MAC Table Size 8K Features Hitless ATPC, AGC, FEC VLAN Tagging IEEE 802.1Q (4K VLAN entries), QinQ
QoS Priority 8 Queues, support SP and WRR mode
Interface QoS Classification VLAN ID, CoS, ToS, DSCP 4 x 10/100/1000 Base-T (RJ-45) Ethernet 2 x 100/1000 Base-X (SFP) 1 x 100/1000/2000 Base-X (SFP)
Up to 16 xE1/T1 (Programmable), 120Ω Mechanical & Environmental
E1/T1* balanced (RJ-45) or 75Ω unbalanced IDU: 22 x 442 x 240 / 0.9 x 17.4 x 9.4 (BNC) via Interface Adapter Dimensions (H x W x D – mm / in) ODU: 279 x 240 x 92 / 11.0 x 9.4 x 3.6 Serial Port RS-232 via RJ-45 connector
2 digital inputs, 1 relay outputs, 1 digital IDU: 3.0 / 6.6
inputs / relay outputs reuse Weight (kg / lb) AUX/Alarm ODU: 4.2 / 9.3 (Reuse, RJ-45) Async (19.2Kbit/s) / Sync (64Kbit/s), RS- 422 protocol Power Consumption Maximum 60W per system LED Indicator RUN, IDU Alarm, ODU Alarm, ETH Power Supply Voltage -48V DC
IDU: -5oC to +55oC
Temperature Range Management ODU: -33oC to +55oC Ethernet VLAN or Separate Ethernet Management Port IDU: ≤85%, non-condensing (RJ-45/SFP) Humidity Security/Authentication Authentication used password ODU: ≤100%, condensing
SNMP SNMP traps, MIB, SNMPv1/v2c
Configuration HTTP, HTTPS, Telnet, SSH, Serial CLI
Loopbacks System Loopback, IF Loopback
NOTICE: * Interface quantity is optional, and please contact Comba for more details.
Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. Page 3 of 3 All rights reserved. DS-Control:2-2-0/ 0414