Professional Documents
Culture Documents
2020 Cummins Electrolyzers
2020 Cummins Electrolyzers
Electrolyzer
Technologies
2020 Update
S I N C E 2 0 1 5 , H Y D RO G E N H A S TA K E N A
F U N DA M E N TA L RO L E I N T H E E N E RG Y T R A N S I T I O N
61.6K
Global Employees
1.4M+
Engines built in 2019
Engines Power generators
8K
Distributor & dealer locations
$1B
Invested in research &
development in 2019
Nominal hydrogen flow 15 Nm³/h 60 Nm³/h 100 Nm³/h 500 Nm³/h 1.000 Nm³/h 4.000 Nm³/h
▪ HyLYZER® 200/300/400/500-30
• Containerized system
• Turnkey product (Plug&Play):
including hydrogen gas generation
system, power rectifier AC-DC, water
purification (reverse osmosis), cooling
(dry cooler)
• Dual stack platform: up to 2 cell
stacks of 250 Nm³/h (1,25 MW) to
reach 500 Nm³/h (2,5 MW)
• Product versions:
- 1,0 MW: 200 Nm3/h (1 stack)
- 1,5 MW: 300 Nm3/h (2 stacks)
- 2,0 MW: 400 Nm3/h (2 stacks)
- 2,5 MW: 500 Nm3/h (2 stacks)
• Output pressure: 30 barg
1,5 MW, WindGas Reitbrook, Germany 1 MW, P2P EGAT, Thailand 1 MW, MEFCO2, Germany
1,2 MW, HyBalance, Denmark 2,4 MW, Wind to Gas Energy, Germany 2,5 MW, Markham Energy Storage, Canada
1 4
MW Scale Electrolyzer Fast Response and
Stack Dynamic Operation
Key requirement established
3.0 MW industry benchmark
2 5
Reduction of Plant Very compact
Capital Costs
Achieved target system cost Lowest footprint on the market
▪ HyLYZER® 1000-30
• Indoor system
• Modular product (to be integrated):
including hydrogen gas generation
system, power rectifier AC-DC
• Dual stack platform: 2 cell stacks of
500 Nm³/h (2,5 MW) to reach 1000
Nm³/h (5 MW)
• Output pressure: 30 barg
HyLYZER®-1000 – Balance-of-Stack
2x 1500E cell stack (high)
1000 Nm³/h (~5 MW) in total
EFFICIENCY
Stack Operating Temperature 65 ± 5°C (149 ± 41°F)
Rectifier Input 4.16 to 30kV, 50/60Hz, 7MVA rating
Rectifier Efficiency >97% at rated flow (>95% over range)
INSTALLATION
Electrolyzer Dimensions (LxWxH) 8.4 x 2.3 x 3.0 m (27.7 x 7.5 x 9.8 ft)
Rectifier Dimensions (LxWxH) 4.5 x 2.5 x 3.2 m (14.8 x 8.2 x 10.5 ft)
DURABILITY
Installation Environment Indoor, ventilated, non-classified, 5 to 40°C (41 to 104°F)
Indoor rectifier to be installed in a controlled access electrical vault
Stack Refurbishment Interval 64,000 to 80,000 operating hours (8 to 10 years at 95% capacity factor)
Specific Energy Increase 1% per annum (for >8,500 operating hours per year)