Professional Documents
Culture Documents
BILL OF QUANTITIES
Building structure
Providing and laying in position machine batched and machine mixed design mix
M-25 grade cement concrete for reinforced cement concrete work, using cement
content as per approved design mix, including pumping of concrete to site of laying
but excluding the cost of centering, shuttering, finishing and reinforcement,
1 5.33 including admixtures in recommended proportions as per IS: 9103 to accelerate,
retard setting of concrete, improve workability without impairing strength and
durability as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less
cement used as per design mix is payable/recoverable separately).
Providing M-40 grade concrete instead of M-25 grade BMC/ RMC.(Note : Cement
5.34.3
content considered in M-40 is @ 360 kg/ cum)
Pending works
Providing and laying in position cement concrete of specified grade excluding
4.1
the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm
4.1.8
nominal size)
P.C.C
All the structural and non-structural wall members shall be precast members only.
No brick work shall be allowed. However, in exceptional cases and only with the
approval of Engineer-in-Charge, block work with AAC blocks can be executed
with 200mm thick for external walls and 150mm for internal walls using AAC
1.4
block joint adhesive of 3 to 5 mm thickness. RCC band of minimum 100 mm thick
at window sill level & lintel level shall be provided in such case. Further in such
case, only Fly Ash bricks with cement mortar 1 cement : 6 coarse sand shall be
provided in foundation and upto plinth level
2 WOOD WORK :
Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash
9.1
fasteners of required dia & length (hold fast lugs or dash fastener shall be paid
for separately).
1 125mm X 75 mm
2 100 mm X 75 mm
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part
I)
9.20 decorative type, core of block board construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with vertical grains or cross bands and face
veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary
9.20.1
screws
Providing and fixing panelled or panelled and glazed shutters for doors, windows
and clerestory windows fixing with butt hinges of required size with necessary
9.5 screws, excluding panelling which will be paid for separately, all complete as per
direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall
be paid separately)
9.5.1 Second class teak wood
9.5.1.2 30 mm thick shutters
Factory made 2nd class kiln seasoned and chemically treated teak wood shutter of :
Main entrance shall be with door of 50 mm thick and 2000 X 2400 mm size (in
double leaf) fully paneled with 25 mm thick second class teak wood panels
including side fixed glazing of 10 mm thick itched glass to the required design and
pattern.
30 mm thick paneled teak wood shutter in styles and rails with mosquito proof wire
2.2 mesh of SS 304 grade powder coated of aperture 1.4 X 1.4mm
Factory made flush door shutter of :-
Main door of guest room shall be 35mm thick flush door with 3mm thick veneering
(natural teak wood shade or equivalent) on both sides.
Balcony and toilet door of the guest room shall be 35mm thick flush door with
3mm veneering (natural teak wood shade or equivalent) on one face and polyvinyl
film coated on other side.
Wardrobe should provided with ferro cement shelves. All the wood work shall be
provided with 18mm BWP grade plywood finished with 3mm thick veneering (of
2.3 shade natural teak or equivalent) on external face and 1mm laminate on internal
face, all with SS 304 grade fittings complete as per approved drawings and
direction of Engineer – In – Charge.
laminate sheet
2.4 Door fittings
All fittings of SS 304
Main entrance door to guest house:- Long handle of minimum 600mm length;
sliding door bolt of 450mm, tower bolts of 600mm long. Hydraulic door closure of
suitable capacity (85Kg).
Main door of guest room :- Dual locking system (swipe + manual) of 6 levers with
handle; tower bolt – 250mm, concealed safety chain.
Long handle of minimum 600mm length
sliding door bolt of 450mm
tower bolts of 600mm long
9.83 Hydraulic door closure of suitable capacity (85Kg)
Dual locking system (swipe + manual) of 6 levers with handle
tower bolt – 250mm
concealed safety chain.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,
channels, plates etc., including welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with necessary stainless
steel nuts and bolts complete, i/c fixing the railing with necessary accessories
10.28 & stainless steel dash fasteners , stainless steel bolts etc., of required size, on
the top of the floor or the side of waist slab with suitable arrangement as per
approval of Engineer-in-charge, (for payment purpose only weight of stainless
steel members shall be considered excluding fixing accessories such as nuts,
bolts, fasteners etc.).
1 meter high railing with SS 304 grade stainless steel of 50 mm dia. of 18 gauge
handrail with adequate rods parallel to handrail, balusters, flanges, end caps, newel
1.3
posts with caps etc. complete as per approved drawing and direction of Engineer –
in – charge.
3 STEEL WORK :
3.1 MS Grill in windows
All windows should be fitted with MS grill (minimum weight 10 kg per sqm) as
9.48
per approved drawings.
Providing and fixing factory made uPVC white colour casement/casement cum
fixed glazed windows comprising of uPVC multi-chambered frame, sash and
mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2
mm
thick galvanized mild steel section made from roll forming process of required
length (shape & size according to uPVC profile), uPVC extruded glazing beads of
appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction
hinges,
zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size
for fixing frame to finished wall, plastic packers, plastic caps and necessary
stainless
9.147A
steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at
all corners, mullion (if required) shall be also fusion welded including drilling of
holes for fixing hardware's and drainage of water etc. After fixing frame the gap
between frame and adjacent finished wall shall be filled with weather proof silicon
sealant over backer rod of required size and of approved quality, all complete as
per approved drawing & direction of Engineer-in-Charge. (Single / double glass
panes and silicon sealant shall be paid separately)
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein
dimension i.e. in depth & width of profile shall be acceptable. Variation in profile
dimension in higher side shall be accepted but no extra payment on this account
shall be made.
Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made
of (big series)frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of
9.147A.4 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate
dimension.
(Area of window above 0.75 sqm.)
Three track UPVC frame with double shutters with glazed panels & other with wire
mesh (of SS grade304 powder coated) shutter as per approved drawing and
matching UPVC Extruded frames sections with minimum wall thickness 2.2 mm.
4 FLOORING :
Providing and laying Vitrified tiles in different sizes (thickness to be specified
by manufacturer), with water absorption less than 0.08 % and conforming to
I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,
11.46
over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing
with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white
cement & matching pigments etc. complete.
11.46.2 Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy
grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener
11.48
and 0.20 kg of resin per kg), including filling / grouting and finishing complete as
per direction of Engineer-in-charge.
All rooms: Double charged vitrified floor tiles of size 600x600 mm laid with
adhesive and with spacers, groove filled with epoxy grout.
Corridor, Lobby & staircase area: Pre Polished Granite stone slab 16mm thick
flooring as per the approved color, design & pattern with dado/skirting up to 1000
mm height (single slab) with matching stone moulding (machine made).
Balcony, Dining, WC Bath - Antiskid rectified ceramic floor tile of minimum size
300x300 mm laid with adhesive and with spacers, groove filled with epoxy grout
as approved by Engineer –in-Charge.
Kitchen, Store room :- With 22mm minimum thick Kota stone
Electrical room, store rooms : Kota stone of 22 mm flooring with rubber mats in
from of panels.
Providing and laying Polished Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building all complete as
per the architectural drawings with 18 mm thick stone slab over 20 mm (average)
11.56 thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with
cement slurry and pointing with white cement slurry admixed with pigment of
matching shade including rubbing , curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or
11.56.1
equivalent.
Corridor, Lobby & staircase area: Pre Polished Granite stone slab 16mm thick
flooring as per the approved color, design & pattern with dado/skirting up to 1000
mm height (single slab) with matching stone moulding (machine made).
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or
more (thickness to be specified by the manufacturer), of 1st quality conforming
to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown,
11.39
laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with
grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement
and matching pigments etc., complete.
Balcony, Dining, WC Bath - Antiskid rectified ceramic floor tile of minimum size
300x300 mm laid with adhesive and with spacers, groove filled with epoxy grout
as approved by Engineer –in-Charge.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed
with grey cement slurry mixed with pigment to match the shade of the slab,
11.26
including rubbing and polishing complete with base of cement mortar 1 : 4 (1
cement : 4 coarse sand) :
11.26.1 25 mm thick
Kitchen, Store room :- With 22mm minimum thick Kota stone
Electrical room, store rooms : Kota stone of 22 mm flooring with rubber mats in
from of panels.
4.2 Skirting
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid
on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and
11.27
jointed with grey cement slurry mixed with pigment to match the shade of the
slabs, including rubbing and polishing complete.
4.2 d 22mm minimum thick Kota stone
Specifications for materials of skirting will be same as for flooring with matching
joint pattern having 100mm height laid with
4.3 Kitchen
Kitchen should be designed as industrial kitchen so that all modern cooking
equipment and appliances for mass cooking can be accommodated. However,
mechanical ventilation and kitchen equipment are outside scope of this work.
Full height wall cladding with glazed tile of minimum size 600 mm x 300 mm in
kitchen laid with adhesive.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineerin-
8.31 Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white cement mixed with pigment of matching
shade complete.
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer
11.43 modified quick-set tile adhesive (Water based) conforming to IS: 15477, in
average 3mm thickness.
In dining decorative / art work in ceramic / vitrified tiles / wood work of suitable
design and size in approved pattern up to false ceiling level laid with adhesive;
Toilet - Glazed/digital/coloured rectified ceramic tiles of minimum size 600 mm x
300 mm upto 2400mm laid with adhesive
b)Staircase: Landing, Tread and riser
Single length 16mm thick Granite flooring with suitable moulding fixed with
dado/skirting up to 1000 mm height. The riser height of staircase should not be
more than 150 mm and tread width not be less than 300mm.
c) Fully exposed columns inside the building
Fully exposed columns inside the buildings if proposed shall be fully covered with
16mm thick granite wall lining (veneer work) of colour & textures as approved by
the Engineer – in – charge . In case of circular column, Satin finished SS sheet of
304 grade may be used to full height.
5 ROOFING
with
zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm,
at
1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5
mm
dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle
hangers
of 25x10x0.50 mm of required length with nuts & bolts of required size and other
end
of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick
bottom
wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at
450
mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate
12.45
channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter channels 0.5 mm thick 27 mm high
having
flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition
with
the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230
mm
interval, including fixing of gypsum board to ceiling section and perimeter channel
with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including
jointing
and finishing to a flush finish of tapered and square edges of the board with
recommended jointing compound , jointing tapes , finishing with jointing
compound
in 3 layers covering upto 150 mm on both sides of joint and two coats of primer
suitable for board, all as per manufacturer's specification and also including the
cost
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :
12.45.1
2011 (Board with BIS Certification marks)
False Ceiling
Gypsum Board false ceiling of approved pattern and design in all rooms, reception,
Dining hall and meeting hall with LED decorative lamps etc.
Providing & fixing false ceiling at all height including providing & fixing of
framework made of special section, power pressed from M.S. sheets and
galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS :
277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges
of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash
fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat
fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts &
bolts of required size and other end of angle hanger fixed with intermediate
G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which
the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges
of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction
perpendicular to G.I intermediate channel with connecting clip made out of
2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter
12.59
channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long,
the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at
450mm centre, with 25mm long dry wall screws @ 230mm interval, including
fixing of Calcium Silicate Board to ceiling section and perimeter channels with
the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing
& finishing to a flush finish of tapered and square edges of the board with
recommended jointing compounds, jointing tapes,finishing with jointing
compounds in three layers covering up to 150mm on both sides of joints and
two coats of primer suitable for boards, all as per manufacture's specification
and also including the cost of making opening for light fittings, grills, diffusers,
cut outs made with frame of perimeter channels suitably fixed, all complete as
per drawings, specificaton and direction of the Engineer in charge but
excluding the cost of painting with:
8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials
12.59.1
reinforced with cellulose fiber manufactured through autoclaving process.
Calcium silicate board in toilets.
All the false ceiling area shall be treated with cement based putty in two coats,
primer and 2 or more coats of premium plastic emulsion paints
Internal finishing:
All the internal surfaces including ceiling shall be finished with one coat of cement
6.2 primer, cement based wall putty in two coats and two or more coats of premium
plastic emulsion paint with low VOC. However, wherever false ceiling is provided,
slabs can be treated with one coat cement primer only.
cement based wall putty in two coats
one coat of cement primer
two or more coats of premium plastic emulsion paint with low VOC.
6.3 External finishing
External wall surface shall be finished with texture finish and smooth finish in 3:1
or so ratio. Smooth finish areas to be treated with cement based wall putty in two
coats. The finish shall be 2 or more coats of premium acrylic smooth weather proof
exterior paint over a coat of cement premier
wall putty
cement premier
2 or more coats of premium acrylic smooth weather proof exterior paint
texture finish
6.4 Primer
As per CPWD Specification for wood work and steel work.
6.5 Painting on wood work & steel work
Malamine Polish over and under coat of flatting varnish on teak wood &
decorative veneered surfaces and Synthetic enamel paint in other areas.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL
2.35 antitermite
treatment (excluding the cost of chemical emulsion) :
Along external wall where the apron is not provided using chemical emulsion
2.35.1 @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm
including excavation channel along the wall & rodding etc. complete:
2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
7 MISCELLANEOUS
Anti termite treatment
Providing and injecting chemical emulsion for post constructional anti termite
treatment along the external wall on vertical surface of soft structure up to depth of
300mm
7.1 Plinth Protection :
100 mm thick RMC M-15grade with nominal reinforcement 0f 8mm dia, TMT bar
@ 300mm spacing in both ways over 75mm thick bed of sand, Half brick masonry
edging laid lengthwise to 150mm depth and finishing with floating coat of neat
cement punning and false squares on top and finishing the exposed brick work and
concrete edge with cement plaster etc, complete.
4.20.1.1 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum)
concrete M15
5.22.6 steel
2.27 75mm thick bed of sand
Total Amount
Finsihing works
Precast works
Elecrical works
Electrical conduit
fire alarm
Fire fighting
DG
Split AC
Solar water heater
Plumbing and External Works
e (G+1) at NITTTR Office campus at Taramani,Chennai-113
NTITIES
% increase in rate
Unit Quantity Rate Amount for 2 years (10%
+5%)
cum
cum 980.276 -
cum
cum 1614.261 -
Sqm
Sqm 386.844 -
kg
kg 68475.762 -
kg 63602.493 -
rnm
rnm 2218 -
cum 1155.043 -
cum
cum 128.338 -
-
cum 1050.701 -
cum 1036.452 13,765.100 14,266,865.425 15,829.865
cum 1036.452 228.300 236,621.992 262.545
sqm
cum
cum
nos
cum 3.750 -
cum 1.526 -
sqm
sqm
sqm 19.20 -
sqm 91.20 -
sqm 49.92 -
sqm 64.80 -
sqm 73.08 -
nos 4.00 -
nos 2.00 -
nos 4.00 -
nos 2.00 -
nos 38.00 -
nos 38.00 -
nos 38.00 -
kg
rnm 202.712 -
kg 2187.26248 -
kg 1797.30
Sqm
Sqm 179.73 -
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm 930.588 -
sqm
Sqm 1055.053 -
Sqm
Sqm 389.046 -
Sqm
Sqm 66.897 0
Sqm 35.032 0
Sqm
sqm
sqm 3.79 0
Sqm
Sqm
Sqm 58.275 0
Sqm
Sqm
Sqm 111.81 0
Sqm 703.857 0
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm 991.365 0
Sqm
Sqm 162.713 0
Sqm
Sqm 4196.909 0
Sqm 4196.909 0
Sqm 4196.909 0
Sqm
Sqm
metre
cum
cum 127.358 0.000
kg 3629.35 0.000
cum 95.52 0.000
Rate With 18%
Amount Amount Remarks
profit
Work completed
Work completed
16,406,895.239 18,679.241 19,360,136.382
272,115.290 309.803 321,096.043