You are on page 1of 8

Ningbo Water Meter Co., Ltd.

Specification of
Single-jet dry type water meter
with LoRa Application

Prepared by Chen FuGuang Date 2016/10/12


Reviewed by Date
Granted by Date
Signed by Date

Ningbo Water Meter Co.,Ltd.


All rights reserved

-1-
Ningbo Water Meter Co., Ltd.

Revised Record

Date Revised Revised Description Prepared by Reviewed


version chapters by
2016/10/12 V1.0 Confirm customer Chen
specifications FuGuang
v1.1 ZhangQin

-2-
Ningbo Water Meter Co., Ltd.

Single-Jet dry type water meter


with LoRa application

1- Application

SJ-SDC/ SJ-SDC-PLUS (LoRa application) is the smart water meter based on single jet mechanical dry type water
meter, the meter reading data transfer from Non-magnetic pulses counting to LoRa module to realize wireless
remote reading, real time flow status monitoring and consumption behavior analysis, the appearance is shown in
Figure 1

Figure 1

2- The system network topology and measurement principle

LORA Water
Meter

LORA LORA Data show


Network Network platform

Network topology structure Figure

-3-
Ningbo Water Meter Co., Ltd.

3. - Key points

Transmission module and base meter is separately installed, easily exchanged. The power supply
battery is independently packaged and is convenient to replace.

A- Use the latest LoRa data transmission technology, network cover wide, signal is stable and reliable. C-

The transmission position is 1L.

D- Based on the original base meter, it can directly install transmission module, only increase 28CM, the

module can rotate, it’s very easy and convenient to install.

E- The base meter adopt the independent function pointer, after installing the electronic module, it doesn’t

affect any reading.

F- During the process of water meter with transmission module, it often happen the problem of repeated

counting because the water flow reverse and shake.

Using two sensors and a special algorithm can ensure the accuracy of the count.

G- 26500+SPC1520 power combination technology, normally ER26500 battery is used for water meter

working with lower power consumption and charge for SPC1520. When LORA need to launch, SPC1520

can provide power supply with maximum peak current up to 2A, to ensure the stability of emission.

4- NB-IOT water meter performance parameter

Performance Parameter
Working voltage 3.6V
Working power supply 26500+SPC1520
Data storage Data is stored for 10 years
Data collecting way Non-magnetic Transmission
Communication mode LORA
Working frequency Depend on customer requirement
Communication distance Base station signal coverage
Standby current < 40uA
Electromagnetic environment E1

Environment temperature 0.1~50℃;

Medium temperature Cold water meter: 0.1℃~30℃;

Water pressure ≤ 1 M Pa;

-4-
Ningbo Water Meter Co., Ltd.

Protection level IP68


Installation environment B class, prohibit the strong magnetic environment
Pressure loss ≤0.063MPa

Upstream and downstream sensitivity level U0, D0

Battery life 6+1 year

Table 1

Technical data of mechanical meter:

Max. Flow Normal Flow Transitional Flow Min. Flow


Size Min. Reading Max. Reading
Type Q4 Q3 Q2 Q1 Q3 /Q1

mm (m3/h) (l/h) m3

SJ-SDC 50 31.25 80
15 3.125 2.5
SJ-SDC-PLUS 25 15.625 160

SJ-SDC 80 50 80
20 5 4
SJ-SDC-PLUS 40 25 160

SJ-SDC 126 78.75 80


25 7.875 6.3 0.00005 99999
SJ-SDC-PLUS 63 39.375 160

SJ-SDC 200 125 80


32 12.5 10
SJ-SDC-PLUS 100 62.5 160

SJ-SDC 320 200 80


40 20 16
SJ-SDC-PLUS 160 100 160

Table 2

MAX. PERMISSION ERROR:

From Q1 inclusive up to but excluding Q2 is ± 5%;

From Q2 inclusive up to and including Q4 is ± 2% for T30 and ± 3% for T90 ;

-5-
Ningbo Water Meter Co., Ltd.

Figure 3

3- Dimensions

Size Dn15 Dn15 Dn15 Dn15 Dn20 Dn25 Dn32 Dn40


L 80 110 115 120 130 160 160 200
L1 174 204 209 214 234 280 284 331
D G3/4B G3/4B G1B G3/4B G1B G1-1/4B G1-1/2B G2B
d R1/2 R1/2 R3/4 R1/2 R3/4 R1 R1-1/4 R1-1/2
H 84.5 84.5 84.5 84.5 84.5 106 106 123
H1 145.5 145.5 145.5 145.5 145.5 167 167 184
W 81.5 81.5 81.5 81.5 81.5 84 84 110

-6-
Ningbo Water Meter Co., Ltd.

The battery can be replaced. Open the battery box seals and screws, remove the battery box, and replace

the new battery box as shown in Figure 6. If the meter has already been installed, no need to remove

the module, , just directly replace the battery as shown in picture.

Figure 4

4- Function achievement

Function Details
The water meter report in the daily cycle. Data

includes accumulated daily flow, daily maximum flow


Water meter data cycle reporting
rate, daily maximum flow time stamp, and the

accumulated daily flow rate.

Change the sending frequency through the platform

High frequency cycle reporting network settings. The minimum cycle reporting is

one-hour.

Fixed flow, over this traffic will be alarmed, setting


High flow alarm
through the network.

Set the base through the infrared device to ensure

Setting the meter base that the electronic reading is synchronized with the

mechanical reading of the meter.

Through the infrared device to set the water meter


Water meter number setting
number, to ensure that the meter number and water

-7-
Ningbo Water Meter Co., Ltd.

meter print number synchronization.

The running time of the water meter is synchronized

Time calibration setting with the outside time. This function is realized in the

periodic report, setting by LORA.

Set frequency point through infrared device, IP, to


Frequency setting,
ensure that the water meter frequency and IP are
including IP settings.
synchronized with running network frequency and IP.

Through daily 24-hour accurate meter data (L)in

platform software. User set alarm period, at this time,


Low flow alarm
if lower than setting water flow, the platform will

alarm.

Display battery voltage to determine the battery


Battery voltage display
condition. The software platform set alarm on 2.8V.

Retransmission The times of retransmissions can be set.

Different start time on cycle reporting Each meter cycle has different start time.

Software version number, protocol version Setting and reading by infrared.

Work log Reading by infrared.

Table 4

Note

Battery inside, forbid to put fire


Do not puncture the battery
Precautions about battery
Install and replace battery to prevent the
short-circuit
Table 5

-8-