You are on page 1of 3

STT Ma V §t TIT Ten VTTB/djch vy hang hoa Ky Ma Hifu/ Nha san xuat DVT So Lugng

Dac Tinh Ky Thuat FlpOH3BO/K TBO 3aB0/l EA.H3M KOJI -BO


n/ n ( Vi t-Anh/Nga ) So chi tiet
^
*
KOA MTP TexHHnecKMe
HaRMeHoeaHMe MTP/ycjiyr Tun, MapKa Manufacturer Unit Quantity
xapaKTepHCTKH
(BbeT - aHrji pycc.) Sign code/
^ Jfe jierskJiH P/N
Long description

-/ -2 -J -4 -5 -6 -7 -8

FLAME DETECTOR / fleTeKTop ruiaMCHH


- - -
DATA SHEET CTC 1 .CTC2 -002 GE IA2 DS 004
Tropical, Marine, Offshore, Open -door
- CTC 2-FD- I 001
TRANSMITTER
Type: Triple Infrared (3IR) / Multi-spectrum Infrared ( MSIR );
- -
CTC2 FD 1002
CTC 2-FD- 1003
Sensitivity: 0.1 m2 n-Neptane pan fire at 30 m; CTC 2-FD- 1004
Response Time: up to 5 secs; CTC 2-FD-1005
Field of View: Minimum 90 deg horizontal axis, 75 deg vertical - -
CTC2 FD 1006
axis; CTC2-FD-2001
12.1 00.068.020.00162
-
Analog output: 0-20 mA (stepped ), source mode, HART, 3 wires CTC 2-FD-2002
~ nt ~ SET 16
Power supply: 24 V DC nominal ; -
CTC 2 FD-2003
Fault Monitored: Built- in-Test (Automatic and Manual ); -
CTC2-FD 2004
Local Status Indicator: LED; CTC 2-FD-2005
Housing: Zone 1 , Ex d IIA T3, IP56 min, 316 SS; CTC 2-FD-2006
-
Safety Level : SIL 2; - -
CTC 2 FD 2007
Electrical connection: 2 x 1 /2" NPT-F; - -
CTC2 FD 2008
ACCESSORIES - -
CTC2 FD SPARE
-
Mounting Bracket (Vertical / Horizontal Tilt ) for 2 inch pipe -
CTC 2 FD- SPARE
stand, 316 SS, c/w bolts and nuts;
Weather protector, Air Shield.

07/05/ 2021 14:12:02 PM Page 19 of 24

Am
STT Ma V &t Tir Ten VTTB/dich vy hang hoa Ky Ma Hif u/ Nha san xuat DVT S6 Liryug
n/ n Ko/i MTP ( Vi $t-Anh/ Nga ) So chi tiet Dale Tinh Ky Thuat IlpOH3 BOACTBO 3aB0A EA.H3M KOJI - BO
TexHHHecKHe
HaHMeHOBaHHe MTP/ycjiyr Tun , MapKa Manufacturer Unit QUANTITY
xapaicrepHCTKH
( BbeT - aarjiJpycc.) Sign code/ Long description
Jfe iieTajiH P/N
-/ -2 -3 - 4 -5 ~6 -7 -8
-
CTC2-GD 1001
- -
CTC2 GD 1002
-
CTC2 GD- 1003
CTC2-GD-1004
GAS DETECTOR / /JeTCKTOp ra 3a -
CTC2 GD- 1005
-
DATA SHEET CTC 1 .CTC2 002-GE- IA 2-DS-003 - -
CTC 2 GD I 006
Tropical, Marine, Offshore, Open -door CTC2-GD- 1007
TRANSMITTER CTC2-GD- 1008
-
Type: Dual Wavelength Infrared , Point , for Hydrocarbon Gas; - -
CTC2 GD 1009
Range; 0- 100 % LEL; -
CTC2-GD 1101
Response Time: less 7 secs; CTC2 -GD- 1102
- -
Accuracy: ± 3 % LEL (@ 0 50 % LEL ), ± 5 % LEL (@ 51 100 CTC2 -GD- 1103
% LEL ); -
CTC 2-GD 1104
12.2 00.019.007.00092
Power supply: 24 V DC nominal;
-
Analog output: 4-20 mA (stepped ), source mode, HART, 3- wires; CTC 2-GD 1108
- -
CTC 2 GD 2001
——fit SET 27

Local Status Indicator: LED; -


CTC2 -GD 2002
Housing: Zone 1, Ex d 1IA T3, 1P56 min, 316 SS ; - -
CTC2 GD 2003
Safety Level : SIL-2; - -
CTC2 GD 2004
Electrical connection: 2 x 1 /2 " NPT-F; CTC2-GD-2005
ACCESSORIES CTC2-GD-2006
Mounting Bracket for 2- inch pipe stand , 316 SS, c/ w bolts and -
CTC 2-GD 2007
nuts; -
CTC2 -GD 2008
Sunshield / Water splashes protection -
CTC2-GD 2009
-
CTC2 GD-20 I 0
CTC2-GD-2011
CTC2-GD-SPARE
CTC2 -GD-SPARE
Ditto item 12.2 , but / /JeTeicrop ma CTC2-GD- 1105
Tropical, Marine, Offshore, In -door, HVAC Duct CTC2-GD- 1106
12.3 00.019.007.00091 ~nt~ SET 3
ACCESSORIES CTC2-GD-1107
Mounting bracket for HVAC Rectangular Duct, 316 SS

07/OS /2021 14:12:02 PM Page 20 of 24

/ Mf
STT Ma Vat TIT Ten VTTB/djch vy h& ng hoa Ky Ma Hi?u/ Nha san xuat DVT So Lirpng
( Vift-Anh/ Nga)
Dac Tinh Ky Thuat CTBO 3a BOA EA - H3M
ri/ n KOA MTP So chi tiet IlpOH3BOi
| KOJI- BO
TexHHHecKHe
HaHMeHOBaHHe MTP/ ycnyr Tun, Mapica Manufacturer Unit QUANTITY
xapaicrepHCTKH
(BbeT - aHrji pycc.)
^ Sign code/
aeTajiM P/N
Long description

-/ -2 -J -4 -5 -6 -7 -8

^
Ditto item 12.2, but / / eTeicrop ra3a
Tropical, Marine, Offshore, In-door
TRANSMITTER
Type: Catalytic Bed Detector, Point, for Hydrogen Gas;
12.4 00.069.028.00250 Range; 0-100 % LEL;
Response Time: T50 < 10 s, T90 < 30 s;
CTC2-GD-2 I 02 —fit— SET 1

ACCESSORIES
Mounting Bracket for 2- inch pipe stand, 316 SS, c/w bolts and
nuts;
TEST KIT FOR HYDROCARBON GAS DETECTORS -
KoMruieKT TCCTHposaHUJi H noBepKH AaTHHKOB ma
12.5 00.019 .007.00089
6 D Cylinder Type, Calibration Gas Methane,103 liters, lOOOpsig,
0 -nt- SET 2
50% LEL CH4 ( 2.5% CH4), balance in air
Gas Flow Regulator / Pery /urrop ma
12.6 00.019.007.00078 Veriflow Gas Regulator, 0.5L/m for TEST KIT FOR
HYDROCARBON GAS DETECTORS
0 —nt— SET 1

TEST KIT FOR HYDROGEN GAS DETECTORS KoMruteid -


recTHpoBaHH* M noBepKH AaTHHKOB r aia
12.7 00.019 .007.00108 6D Cylinder Type, Calibration Gas Hydrogen, 103 liters,
lOOOpsig, 50% LEL H2 ( 2% H 2 ), balance in air
0 — nt — SET 1

c/w Veriflow Gas Regulator, 0.5 L / m


TEST KIT FOR FLAME DETECTORS KoMrmcKT -
12.8 00.019 .007.00104 TecTHpOBaHHa H noBepKH AaiuHKOB nnaMCHH 0 ~ nt-- SET 1
According to Manufacturer Standard
VI.GROUP 6: SMOKE DETECTOR AND PUSH BUTTONS