You are on page 1of 28

Breathe Germ-free Air at work,

& at home.
Product Literature & FAQs
Version: Oct 2020
UVC-AirTM is a GERMICIDAL AIR EXCHANGER

Human respiratory activity continuously


introduces aerosol viruses and bacteria
into the air we breathe. A Germicidal
Air Exchanger is a device that actively
reduces the air’s microbial load
through Ultraviolet Germicidal
Irradiation (UVGI). This action
significantly reduces the risk of infection
through respiratory transmission.

UVC-AirTM is a Germicidal
Air Exchanger. It irradiates
pathogens using a UVC
lamp with an optimum
wavelength of 254 nm.
The radiation immediately
neutralizes airborne
pathogens that cause
illnesses.
How UVC-AirTM inactivates viruses & kills bacteria that cause
illness.

STEP 3
Air Exits Safe to breathe,
disinfected room air
released into the room
without the risk of
harmful UVC radiation
exposure.
UVC Air Disinfection

STEP 2
Within the protective
enclosure of the
device, a 254 nm UVC
germicidal lamp
irradiates airborne
viruses, bacteria &
other germs.
Air
Enters
STEP 1
Room air is drawn into
the device and
exposes it to a powerful
ultraviolet-C (UVC)
germicidal lamp.
VIRUS AND BACTERIA NEUTRALIZED
BY UVC EXPOSURE
The germicidal lamp inside the UVC-AirTM disrupts
the DNA structure of viruses and bacteria. This
exposure renders the microorganisms harmless.

254 nm UVC Irradiation


breaks DNA bonds
UVC-AirTM MITIGATES AIRBORNE PATHOGENS IN ENCLOSED
SPACES

The Center for Disease Control and Prevention now says the coronavirus
can be spread through airborne particles that can linger in the air “for
minutes or even hours” – even among people who are more than 6 feet
apart.

The CDC still says that SARS-COV-2, the virus that causes COVID-19,
is most frequently spread among people in close contact with one
another, through respiratory droplets produced when an infected person
coughs, sneezes or talks. But in a new guidance published Monday on its
website, the agency also acknowledged that under certain circumstances,
people have become infected by smaller particles that can linger in the
air in enclosed spaces that are poorly ventilated.
GERMICIDAL AIR-EXCHANGER
USED IN HEALTHCARE

UVC Germicidal Air-Exchangers is an


established disinfection technology used in
healthcare facilities to augment other
disinfection protocols.

Health Care facilities are subject to microbial airborne hazards


that can cause infection in both patients and health care
workers. Hospital-acquired, or nosocomial infections have been
a persistent problem in hospitals and they can have complex
multifaceted etiologies. It is possible that as much as a third or
more of all nosocomial infections may be the result o airborne
transmission at some point and if so, air disinfection
technologies may be able to reduce the nosocomial rate.

If the direct contact route predominates, as many experts


believe, then surface disinfection technologies could also have a
major impact. Combining air and surface disinfection may be an
optimum approach to reduce infection rates and may very well
be economical to implement. Existing health care guidelines for
ventilation system design, pressurization, filtration and
disinfection procedures have historically held the problem at bay
but
PARTIAL LIST OF
INACTIVATED
VIRUSES AND BACTERIA
EXPLANATORY NOTE ON
THE VIRUS & BACTERIA
INACTIVATION TABLES

The “Inactivation Table” presents a partial list of


airborne viruses and bacteria that will be
inactivated when initially exposed to the irradiation
within the device.
• 1 means it will be inactivated
upon the 1st irradiation exposure.
• >1 means it will take more than 1
irradiation exposure before the
virus can be inactivated.

1. Most airborne viruses are inactivated upon a


single pass through the UVC-AirTM models listed.

2. Viruses have no ability to repair UV damage and


successive UVC exposure will lead to inactivation.

COVID 19 Inactivation:

The irradiation dosage required to inactivate


COVID 19 is currently unknown. However, COVID
19 is a strain of coronavirus. To be inactivated,
coronaviruses only need a single irradiation
exposure.
EXPLANATORY NOTE ON
THE VIRUS & BACTERIA
INACTIVATION TABLES
Inactivation Dosage (J/m2)
@D90 is the required radiation
dose to inactivate a
microorganism with 90%
confidence. Inactivation
Dosage is determined by the
exposure time of the
microbe to the irradiation
energy.

In a germicidal air-
exchanger, radiation
exposure time of microbes in
an airstream is in milliseconds.
Irradiation energy received
by the microbe is increased
by minimizing the distance
between the lamp and the
particle.
Science has determined the rates at which various
microbial populations are neutralized due to exposure to
UVC irradiation. Generally, viruses are the least complex
and the smallest among pathogens. Hence, they will most
likely require the least amount of radiation to be
inactivated.
PARTIAL LIST OF AIRBORNE
VIRUSES INACTIVATED

Virus Inactivation Table


UVC-AirTM Models & Dosage
Strength
Organ System Affected by

UVC-AirTM Transport
Inactivation Dosage

UVC-AirTM Power

UVC-AirTM Assist
UVC-AirTM Eco
(J/M2) @D90
Pathogen
VIRUSES

27J/m2
10J/m2

27J/m2

13J/m2
229E (alpha
1 Respiratory 5.4 1 1 1 1
coronavirus)
OC43 (beta
2 Respiratory 2.9 1 1 1 1
coronavirus)
Respiratory, Central
3 SARS-CoV (SARS) 7 1 1 1 1
Nervous, & Digestive
Respiratory, Lymphatic, &
4 MHV coronavirus 3 1 1 1 1
Digestive

5 Coronavirus Respiratory & Circulatory 6 1 1 1 1

Respiratory, Digestive &


6 Adenovirus 49 >1 >1 >1 >1
others
Respiratory,
7 Coxsackievirus Integumentary (skin), 21 >1 1 1 1
Cardiovascular & others
8 Influenza A Respiratory 19 >1 1 1 1
9 Influenza A H1NI Respiratory 13 >1 1 1 1
Integumentary (skin) &
10 Vaccinia 2 1 1 1 1
Cardiovascular
PARTIAL LIST OF AIRBORNE
VIRUSES INACTIVATED

Bacteria Inactivation Table 1 of 2


UVC-AirTM Models & Dosage
Strength
Organ System Affected

UVC-AirTM Transport
Inactivation Dosage

UVC-AirTM Power

UVC-AirTM Assist
UVC-AirTM Eco
by Pathogen

(J/M2) @D90
VIRUSES

10J/m2

27J/m2

27J/m2

13J/m2
1 Bacillus subtilis Gastrointestinal 14 >1 1 1 >1

Burkholderia
2 Respiratory 11 1 1 1 1
cepacian
Digestive,Urinary &
3 Escherichia coli 5 1 1 1 1
Central Nervous
Integumentary (skin),
Francisella
4 lymphatic, respiratory & 256 >>1 >>1 >>1 >>1
Tularensis
etc.

Mycobacterium
5 Respiratory & lymphatic, 13 >1 1 1 1
bovis BCG

Mycobacterium Integumentary (skin) &


6 15 >1 1 1 >1
Parafortuitum lymphatic,
Mycobacterium Skeletal , urinary &
7 25 >1 1 1 >1
Phlei ophthalmic
Mycobacterium
8 Integumentary (skin) 12 >1 1 1 1
smegmatis
Mycobacterium Respiratory, Central
9 5 1 1 1 1
tuberculosis Nervous, Skeletal & etc.
PARTIAL LIST OF AIRBORNE
VIRUSES INACTIVATED

Bacteria Inactivation Table 2 of 2


UVC-AirTM Models & Dosage
Strength

Inactivation Dosage (J/M2)


Organ System Affected by

UVC-AirTM Transport
UVC-AirTM Power

UVC-AirTM Assist
UVC-AirTM Eco
Pathogen
VIRUSES

10J/m2

27J/m2

27J/m2

13J/m2
@D90

Pseudomonas Urinary, respiratory &


10 4
aeruginosa circulatory
Pseudomonas
11 Circulatory 5
fluorescens
Serratia Respiratory, Urinary &
12 3
marcescens circulatory

Staphylococcu Integumentary (skin) &


13 32
s albus circulatory

Integumentary (skin) ,
Staphylococcu
14 skeletal & 4
s aureus
cardiovascular
Integumentary (skin) ,
Staphylococcus
15 circulatory & 18
epidermis
ophthalmic.
Streptococcus Circulatory, respiratory
16 5
agalactiae & central nervous.
Respiratory, urinary
Streptococcus
17 circulatory & 1
pyogenes
integumentary
Attestation:
UVC-Air microbial inactivation claims are anchored
on existing technology in use, local engineering
design and the empirical validation by our
consultant, a molecular biologist.

*Documents and technical


meetings available upon request.
Proudly Filipino assembled to be
economical, accountable &
trustworthy.
UVC Lamp Technology:
Korean made UVC Germicidal Lamp
• Irradiation 254.7 nm, an effective germicidal wavelength.
• Non-ozone generating lamp. No ozone inhalation hazard.
• Tested by the Korea Research Institute of Standards & Science.
UVC-AirTM MODEL LINE-UP
Home & Office
Room Air
Disinfection
Affordable and compact.
With a UVC dosage
delivery of 10 Joules/m2, it
neutralizes airborne
coronaviruses immediately. It
is capable to safely and
effectively disinfect a 12 m2
room with 2-3 people
present. Recommended for
household and office use.

Model : Microbex UVC-AirTM Eco UV Dose : 10.26 Joules/m2


UVC Lamp : Germicidal Lamp, Power Input : 220 VAC, 8 watts
Non-Ozone Generating Dimensions : 61 x 10 x 4 cm
Lamp Origin : Korea Placement : Room use. Wall with
Wavelength : 254 nm optional floor mount
UVC Intensity : 41 W/m2 Air Exchange: 27 m3/hour
Patient Waiting
Room Air Disinfection

Potent and efficacious.


With a UVC dosage
delivery of 27 joules/m2, It
neutralizes most airborne
microbes on the first
exchange. It is designed
to effectively disinfect a
12m2 room with 3-6 people
at a time. Ideal for health
facilities.

Model : Microbex UVC-AirTM Power UV Dose : 27.25 Joules/m2


UVC Lamp : Germicidal Lamp, Power Input : 220 VAC, 8 watts
Non-Ozone Generating Dimensions : 84 x 10 x 4 cm
Lamp Origin : Korea Placement : Room use. Wall with
Wavelength : 254.7 nm optional floor mount
UVC Intensity: 79 W/m2 Air Exchange: 27 m3/hour
Medical /Dental
Patient Aerosol
Suction
Effectively augments the
need to disinfect the
patient’s oral aerosol
discharge immediately.
With a UVC dosage
delivery of 27 Joules/m2,
it neutralizes most
microbes on the first
exchange, including
airborne coronaviruses.

Model : Microbex UVC-AirTM Assist UVC Dose : 27.25 Joules/m2


UVC Lamp : Germicidal Lamp, Power Input : 220 VAC, 16 watts
Non-Ozone Generating Dimensions : 76 x 10 x 4 cm
Lamp Origin : Korea Placement : Patient-side during
Wavelength : 254 nm treatment/consultation
UVC Intensity: 79 W/m2 Air Exchange: 27 m3/hour
Vehicle Air
Disinfection

Compact yet
effective. With a
UVC dosage
delivery of 12.92
Joule/m2, it will
cleanse 3m of the
3

car’s interior air


within 6 minutes
Ideal for air-conditioned public and private
transport but can be used in the home as well.

Model : Microbex UVC-AirTM Transport Power Input


Transport a. Car Lighter : 12V DC, 12W
UVC Lamp : Germicidal Lamp, b. 220V Adaptor: 220V AC, 12W
Non-Ozone Generating Dimensions : 50 x 10 x 4 cm
Lamp Origin : Korea Placement : Headrest / rear
Wavelength : 254 nm window backboard
UVC Intensity: 51 W/m2 Air Exchange: 27 m3/hour
UVC Dose : 12.92 Joules/m2
HEALTH APPLICATIONS and HUMAN
SAFETY
UVC- AirTM PROTECTS YOU AGAINST HARMFUL UVC
LIGHT EXPOSURE AND DOES NOT GENERATE OZONE

UVC-AirTM
provides a
safe means of
of UVC.
UVC disinfection through germicidal air exchange.

The potentially harmful


UVC light is enclosed in a
protective metal
disinfection chamber. This
enclosure shields users
from harm and allows for
human activity while in
use.

UVC-AirTM does not use UVC


Ozone Generating Lamps.
Thus, it is safe to use around
human activity.
Non-Ozone Generating UVC 254 nm
UVC-AirTM DISINFECTS 27–30 m3 OF AIR PER
HOUR

UVC-AirTM will disinfect approximately 27-30m3 of


air each hour. A room with a floor to ceiling height
of 2.4m & a floor area of 3.5 x 3.5meters has an air
volume of 29.4m3. For larger rooms, with more
people and there a need to have a more
frequent germicidal air exchange, more units
germicidal air exchangers should be added.
AIR PURIFIER GERMICIDAL AIR
IONIZER EXCHAGERS
METHODOLOGIES
AIR DISINFECTION

OZONE STERILIZATION UVC LIGHT


DISINFECTION FOGGER
UVC-AirTM COMPARED TO OTHER METHODS OF
DISINFECTION

It is
primarily designed to kill airoborne germs.
particles.
It can run continuously
up to 16,000 hours.
There are no filters to
replace and dusting
the lamp is the only
maintenance needed.

mechanically collect dust &


microbes from the air using a HEPA filter. The filter
captured
germs aregerms are entrapped but not killed.
entrapped
Regularly
but replacing
not killed. the HEPA filter is a must to
Regularly
remain effective.
replacing the HEPA filter
is a must to remain
effective.
UVC-AirTM COMPARED TO OTHER METHODS OF
DISINFECTION

work by creating a static charge


around the airborne contaminants that are
floating
the air. inOnce
the charged
with static, these particles
simply stick to the nearest
surface they find. Germs
are not eliminated but
rather deposited on the
nearest surface.

is primarily designed to inactivate


germs in the air and surfaces by chemical
aerosol. This type of air
disinfection is momentary
and occurs only when
the chemical aerosol is
present. Also, inhalation
of the chemical aerosol
is harmful.
UVCAirTM COMPARED TO OTHER METHODS OF
DISINFECTION

UVC Lamps disinfects


airborne & surface microbes
through UVC radiation
exposure. However, direct
exposure, exposure time &
distance from the lamp to
the microbe play a
significant role in significant
its effectivity. However,
exposure to UVC radiation is harmful to humans.

The Ozone (O3) generated by UVC Ozone


Generating lamps destroy the cell walls of
microorganisms. Ozone
sterilization is potent,
effective & it permeates
wherever air can reach.
However, it is extremely
hazardous to humans.
Know more:

Search: microbex UVC-Air

fb.me/spmsofficialpage

www.microbex.tech

566 Shaw Blvd, Mandaluyong City


8533-8814 8533-8817
8637-9694 8636-4819

You might also like