YF6 Wind Speed Alarm User Manual Zhengyu Meteorological Instruments Co., Ltd YF6 Wind Speed Alarm User Manual |. Brief Introduction YF6 wind speed alarm have been widely used for several decades in applications of such as railway loading machineries, port-loading machineries, construction tower cranes, bridges, airports, power plants, mines, high-level equipments and watercrafts where wind speed alerting control is necessary, and have also been exported to many other nations and regions worldwide. YF6 is developed to meet our user's latest requirements of being capable of setting wind speed-sampling time arbitrarily with wind speed between 1 — 10s. Il. Technical specification 1. Measurement range of wind speed: 0 — 60m/s. with the error at +(0.5+0.05V) m/s, V—wind speed measurement. 2. Wind speed display: Display continuous average wind speed measured ‘on condition that sampling time is set arbitrarily within 1 — 10s, wind speed instantaneous sampling value: one each 4s, min, 3. Pre-alarm range: 1 — 40m/s, arbitrarily setting. 4. Alarm range: 1 - 40m/s, arbitrarily setting. 5. Analog output: 4 — 20mA_ 6. Power supply: AC 220V or optinal + 10%, 50Hz or 60Hz. Fuse: 1A @5X20mm. 7. Remote measurement distance: < 100m (with 3-core cable of cross-section at 0.4mm’). 8. Volume: sensor 2184mm, height 250mm. display box 180 100 x 110 (mm). 9. Weight: About 2kg. Correspondence between wind speed (m/s) and wind level: Wind level 1 2 3 4 5 6 ms | 03~15 | 16~33 | 34~54 | 55~79 | 80~107 | 108~138 Wind level mis | 13.9~17.1 | 17.2~20.7 | 20.8~24.4 | 24.5~28.4 | 28.5~326| >32.6 7 8 9 10 n 12 Correspondence between Analog Output and Wind Speed Wind Speed (mm/s) 0 5 10 15 20 25 30 ‘Analog Output (4~20mA) 4 | 5.33 | 666 | 7.99 | 9.33 | 10.66| 12 Wind Speed (rnis) 35 | 40 | 45 | 50 | 55 | 60 | / ‘Analog Output (4~20mA) | 13-33 | 14.66 | 15.99 | 17.33 | 18.66 | 20 / ‘Analog output is linear, and wind speed error is in consistent with error formula. Ill. Principle and Function Wind power acts on the wind cup, and force photoelectric code plate to alter output level status of photoelectric converter, the number of pulse outputs changes in proportion to different wind speeds. Wind speed impulses are read to. counting circuit of SCM continuously, continuous arithmetical average set within 1~10s is sent to digital tube to display the average wind speed after 1s sampling is over, and current analog output is provided at the ‘same time. In case that the measured wind speed is under the alarm value, the green light will be on, and in case that the tested wind speed reaches the critical alarm value, the alarm will keep beeping. ‘The master machine possesses both pre-alarm sub-contact and alarm sub-contact, the middle of each set of sub-contact is midline, the left side is normal open and the right side is normal close. When the tested wind speed reaches the set alarming speed, the relay will start to work: normal close contact trips and normal open contact closes, and user can take advantage of this as they like. Besides, 4~20mA analog output is available for data processing with computer. IV. Installation and Debugging 1. The sensor of the alarm should be installed in the highest point of the location without any obstacles surrounding, outer diameter of the top tube of the installation frame should be of 253mm, while the interior diameter of the whole tube must be no less than that of@35mm (for the sake of being as the passage of seven core cable plug), 2. Insert the master machine into the square hole of the instrument box. See the drawing for the outline and dimensions of the master machine. Debugging: Connect the master machine to power supply, turn on power supply switch, the display of 0.00 in 5 seconds indicates normal. Then connect the sensor with the master machine, move the wind cup of the sensor by hand, and corresponding signals should occur in the a master machine. If the master machine is still with the display of 0.00, which is an abnormal consequence that may be caused by the connecting cable or fault of the sensor. 3. In case that user connects the cables by themselves, the operation should be in consistent with the following requirements: 2* wire of seven core cable plug indicates positive pole of power supply and 5* wire indicates negative pole, 7* wire is for signal purpose. Please be sure that the connection of the wires should be in accordance to the above arrangements. For 4-core cable plug: 1%*+" 2*~"3*-signal 4*-GND Shielded wire is strongly recommended if strong power frequency disturbance exists. 4, After the debugging is finished, install the sensor as required above. V. Detailed Operation and Functions of the Keys on the Panel Example, if a user needs the following combination: 1. Wind speed ‘sampling interval at 8s 2. Alarm at wind level of 8 (18 m/s) 3. Pre-alarm at wind level of 7 (14 mis) is preferred, To operate as the following steps: Note 1: key-press duration — to avoid error with key-press, each key-press should last at least 0.5 second, Note 2: selection-123 key — press once the key for pre-alarm setting, twice for the choice of alarm value, three times for setting of wind speed sampling time and press four times will renew the system, 4. Setting of wind speed sampling time — continuously press key three times(now you should find the wind speed sampling time set before)-press Setting key (now flashes will be on) —press [+] or E] key to adjust the time to 8 seconds—press [OK key to finish the setting. 3 2. Setting of alarming speed — press seletiontz8 key once (now you should find the alarming speed set before) —press [setting key (now flashes will be on) —press [+] or [=] key to adjust the speed to 18m/s —- press (OK) key to finish the setting. Notice: The alarming speed should always be higher than pre-alarming speed, so pre-alarming speed should be adjusted lower if alarming speed cannot be adjusted lower. i 3. Setting of pro-alarming speed — press [selection-123| key twice — press [setting key~press [+] o1 key to adjust the speed to 14m/s > press [OK key to finish the setting Notice: 1. The pre-alarming speed should always be lower than alarming speed, so alarming speed should be adjusted higher if pre-alarming speed cannot be adjusted higher. 2. In case of the pre-alarming is unnecessary, just setting pre-alarming speed same as alarming speed. 4. [Wind level / light off | key — press this key to find the wind level, the display will be reset if the tested wind level exceeds the alarm level once, and alarming sound will be stopped while the alarm light is still on, press this key to turn off the light. Frequent check of the settings is needed to avoid the emergence of any confusion. Pre-alarm sub-contact and alarm sub-contact, analog output VI. Maintenance The wind cup of the sensor is made from high-tech materials such as carbonized fiber, which is free of damage from wind force and erosion, but the material is brittle, so direct collision with the wind cup is forbidden as this is will result in damage, and since the wind cup is very expensive, dedication is needed in the maintenance with it The sensor belongs to mechanical transmission categories, and wears down dramatically as it is working in a field condition, for the purpose of prolonging the sensor’s life and ensuring of its precision, a routine maintenance should be carried out every two years, or the sensor may be sent back to our company for detailed maintenance, lubrication or repair. 4 VIL. Set of Components Wind speed sensor Wind speed indicating box Cable for sensor (20m or optinal) User manual Quality certificate pene Vill. Wiring and mounting dimension diagram of wind speed alarm YF 205 70 Mo os ooo 3.M6x 120" Wind speed alarm wiring O7O Wind speed indicating box 3 core shcelded cable Wind speed sensor sesor output socket sensor input socket ( 20~ 200m ) 2 V+ 1 SV + 2 SV - 2 t [\ e713) 5 9 - iy : 3# signal input U \ve. 7# signal output 4# shield Q| | 3 Ba »—olay a *2,.. | ; PC oar atl monitor Be ~ +I % = @ @ 1 Equpment to be or De2av & w Wolo Equpment to be | controlled a5 @ * The contact ratings on the cntrol relay L are : AC220V 3 W¥— GA N= secon Mai — DC 28V — 12A (for reference only)

You might also like