You are on page 1of 2

We make adjustable temperature for that minus delta T from hot stream.

∆ T min =10 C

Stream Ts Tt m Q(KW )=mC×C


p p

H1 250 150 20 200 2


H2 150 60 15 270 3
C1 50 200 10 120 0.8
C2 150 200 5 250 5

Adjusted T:

Ts

245

145

55

155
FOR PINCH TEMPERATURE:

using temperature-interval method, first arrange adjustable temperature in decreasing


order, then mark the range of temperature of hot and cold streams then calculate heat
Q(KW )=C ×(T 1−T 2) after that calculate value of initial pass by taking Q=0 initially
and then add it to following Q e.g. R1= 0+48=48 similarly, for all values. after that find out
the minimum value from the values of R and add that value in final pass and then
calculate values of final pass the top value in final pass is your hot utility and the bottom
value is your cold utility.

Qsteam initial pass final pass

240 Q=0 Q=230KW(HU)

48

200 R1=48 278

276.67-
150 R2=-288.67 1.33

1.33-

140 R3=-230 0 pinch


130

50 R4=-100 130 (CU)


Hot utility is 230 KW

Cold Utility 130 KW

Cold pinch temperature =140 C

Hot pinch temperature =140+10=150 C