You are on page 1of 7

Prosthodont Res Pract 4 :9 -15, 2005

Original Research

Reproducibility and Accuracy in Measuring Masticatory


Performance Using Test Gummy Jelly
Ikebe Kazunori, DDS, PhD, Morii Kentaro, DDS, PhD, Matsuda Ken-ichi, DDS,
Hazeyama Tomohiro, DDS and Nokubi Takashi, DDS, PhD

Division of Oromaxillofacial Regeneration,


Osaka University Graduate School of Dentistry
(Chief:Prof. Nokubi Takashi)

Clinical significance
A reliable assessment of masticatory performance would be a valuable contribution to the practice of evidence-
based dentistry. A method of measuring masticatory performance using the glucose concentration from test
gummy jelly simplified the procedure, reduced the time involved, and provided accurate and reproducible
feedback for assessing masticatory ability.

ABSTRACT
:To establish a simpler and more accurate method of measuring masticatory ability in routine
dental practice compared to current methods.
:To find the most suitable conditions for assessing masticatory performance
using the test gummy jelly,variable factors were investigated,such as temperature and length of rinse
time in water,temperature of distilled water,and dissolution time of glucose. The accuracy of this test
was confirmed by correlating the surface area of the jelly and the glucose concentration. A student s
t-test or ANOVA was used for statistical analysis at the 5% level of significance. The Bonferroni
method was used for multiple comparisons.
:The glucose concentration decreased gradually (p<0.05) as the rinsing time increased but
tended to remain unchanged at 30seconds or more. As the temperature of the distilled water for
dissolving the glucose or the dissolution time increased,the glucose concentration constantly increased
(p<0.05). A linear regression analysis showed that the concentration of glucose had a significantly
high correlation to the surface area (mm ) of the comminuted jelly (r=0.993, p<0.01).
:The concentration of glucose dissolved from the comminuted particles of the test gummy
jelly indicated high reproducibility and accuracy when the rinsing time, temperature of the distilled
water, and dissolution time of the glucose were strictly prescribed.

Key words
masticatory performance, test gummy jelly, glucose, reproducibility, accuracy
Corresponding author:Ikebe Kazunori
1-8, Yamadaoka, Suita, Osaka 565-0871, Japan
Tel:+81-6-6879-2956, Fax:+81-6-6879-2957
E-mail:ikebe@dent.osaka-u.ac.jp
Received on February 1, 2005/Accepted on March 10, 2005

9
10 Prosthodont Res Pract VOL.4 NO.1(2005)

obtain results in the usual clinical environment.


INTRODUCTION The purpose of this study was to establish a
simpler and more accurate method of measuring
The primary purpose of prosthodontic treat- masticatory ability in routine dental practice
ment is not only to restore dental and periodontal compared to conventional methods.
structures, but also to achieve acceptable mas-
ticatory function . Accordingly,establishment MATERIALS AND METHODS
of an objective evaluation of masticatory ability
is indispensable for pre-and post-prosthetic treat- Reproducibility of M easurements
ment. Masticatory performance was evaluated by
The aim of mastication is to comminute food measuring the increase in the surface area (mm )
and to increase the surface area of the food to of the expectorated pieces of comminuted jelly
promote proper digestion and absorption ofnutri- (Fig.1). Subjects were instructed to chew one
ents. There are several objective measures of block of the jelly (10×10×20mm) at their own
masticatory function,such as masticatory perfor- pace on their preferred chewing side (left, right
mance, masticatory efficiency, swallowing or both) and to expectorate the bolus of the
threshold and occlusal force . The most com- comminuted jelly as thoroughly as possible onto
mon technique for qualifying chewed food has a sheet of gauze (Fig.2). The collected parti-
been to measure particle size distribution with a cles of the comminuted jelly were rinsed with
series of mesh sieves . A sieve method using running water to remove the saliva. Then the
peanuts was developed in 1950 and has been particles were soaked in 15ml of distilled water
used until recently . Both real foods,including and stirred. The supernatant fluid of the solu-
peanuts or carrots , and artificial materials, tion was sampled, and the concentration of dis-
such as gelatin or silicone ,have been used solved glucose from the jelly was measured with
to measure masticatory performance. Finding a a blood glucose meter (Glutest, Sanwa Kagaku
universally accepted test food or material has Kenkyusho, Nagoya, Japan) intended for home
been difficult and is still unresolved. Therefore, use by diabetic patients (Fig.3).
new methods are being introduced to simplify the To find the most suitable condition for asses-
procedure, reduce the time involved in testing, sing masticatory performance using test gummy
and provide more relevant measures for assess- jelly, variable factors were investigated, such as
ing masticatory function .
Yamamoto developed an assessment of mas- Subject chews one block of gummy jelly
ticatory performance using the test gummy
jelly test method of evaluating the surface area Comminuted jelly is rinsed with running water

of the comminuted jelly from the dissolved gela-


Distilled water with the comminuted jelly is stirred
tin concentration. This method offers consider-
able advantages such as speed, accuracy and Supernatant is sampled, and
hygiene, compared to the sieve method of analy- concentration of glucose (mg/dl) measured

sis. However,to measure the gelatin concentra-


Increase of surface area (mm ) is calculated
tion,a specific laboratory setting with a spectro-
photometer and more than 40minutes drying Fig. Procedure for measuring masticatory perfor-
time is necessary. Therefore, it is difficult to mance using the test gummy jelly
M easuring Masticatory Performance Using Test Gummy Jelly 11

Fig. Chewing one block of the test gummy jelly


1)One block of the jelly is chewed using 30 strokes
2)Particles of the jelly are collected
3)Particles are rinsed in running water
4)Original and comminuted test gummy jelly

Fig. Measuring glucose concentrations with blood glucose meter


1)Particles of the comminuted test gummy jelly were soaked in distilled water and stirred
2)The measuring tip is inserted into the blood glucose meter(Glutest )
3)The supernatant fluid is touched with the tip
4)The meter displays the concentration of glucose(mg/dl)
12 Prosthodont Res Pract VOL.4 NO.1(2005)

Fig. The test gummy jelly is divided into equal portions

the temperature and length of rinsing time, tem- divided to make surface areas totaling 2,000,
perature of the distilled water, and dissolution 2,400, 3,200, 4,000, and 4,800mm (Fig.4), and
time of the glucose. then the glucose concentrations dissolved from
The preliminary conditions were defined as the divided jellies were measured. A linear
follows:the temperature of the water used to regression analysis of the total surface area of
rinse the particles of jelly was 18℃;the rinsing the divided jelly (mm ) and the glucose concen-
time was 30seconds;the temperature of the tration (mg/dl) was subsequently conducted.
distilled water for dissolution was 35℃;and the The glucose concentrations were measured from
dissolution time was 20seconds. One of these five jellies for each surface area. The increase
variable factors was changed during each test, in the surface area, which indicated masticatory
and then the concentration of glucose was mea- performance, was calculated by subtracting the
sured and compared for each condition. original surface area (1,600mm ) from the total
Five jellies were used for each condition,and surface area of the divided jelly.
the glucose concentration was measured once for
each sample. The statistical analysis was per- RESULTS
formed using a student s t-test or ANOVA at the
5% level of significance. The Bonferroni The glucose concentration was not signifi-
method was used for multiple comparisons. The cantly different between the 18℃ and the 40℃
data analyses were done using the SPSS 12.0for rinse water conditions (Fig.5). However,as the
Windows(SPSS Inc., Chicago, USA). rinsing time increased,the glucose concentration
decreased gradually and tended to remain un-
Accuracy of the Examination changed at 30sec. or more (Fig.6). After a
The accuracy of this test was confirmed by rinsing time of 20sec., the glucose concentration
correlating the surface area of the jelly and the was significantly higher than after rinsing times
glucose concentration. of 30, 40or 60seconds. On the other hand,there
The original form of the test gummy jelly was no significant difference in the glucose con-
(20×20×10mm;surface area:1,600mm ) was centration after rinsing times of 30, 40 and 60
M easuring Masticatory Performance Using Test Gummy Jelly 13

Fig. Influence of rinse water temperature on concen-


tration of glucose
Rinsing time for the comminuted jelly was 30
seconds;dissolution temperature was 35℃; Fig. Influence of temperature of distilled water
dissolution time was 20 seconds for dissolution on glucose concentration

Fig. Influence of dissolution time on glucose


concentration
Fig. Influence of rinsing time on glucose concen-
tration
increased constantly (Fig.8). The standard
deviation for the glucose concentration after
seconds. dissolution of 10seconds was larger than for
As the temperature of the distilled water longer periods.
used to dissolve the glucose increased, the glu- The linear regression analysis showed that
cose concentration increased constantly (Fig.7). the concentration of glucose had a significantly
There were significant differences in the glucose high correlation with the surface area (mm ) of
concentration between a dissolution temperature the comminuted jelly (r=0.993,p<0.001,Fig.9).
of 35℃ and of 30 or 40℃. The glucose concen-
tration exceeded the measurable range when DISCUSSION
distilled water of 50℃ was used. As the dissolu-
tion time lengthened, the glucose concentration It is recognized that a reliable assessment of
14 Prosthodont Res Pract VOL.4 NO.1(2005)

The test gummy jelly to be examined after


comminution was rinsed to remove the saliva,
including glucose,which adhered during mastica-
tion. The temperatures of the running water
tested were 18℃, which was cool enough to pre-
vent the dissolution of the glucose, and 40℃,
which was higher than the maximum room tem-
perature of the clinic. It was found that the
temperature of the running water did not signifi-
cantly affect the concentration of the dissolved
Fig. Relationship between increase in surface area glucose, indicating that the surface area of the
(mm ) of test gummy jelly and glucose concen- jelly had not changed up to 40℃. As the rinsing
tration
time increased, the glucose concentration de-
creased gradually and finally stabilized,suggest-
masticatory performance may be a valuable con- ing that the saliva was thoroughly removed in 30
tribution to the practice of evidence-based den- seconds. In other words,the glucose that adher-
tistry . Objective evaluations of masticatory ed during mastication might remain if the rinsing
performance have usually involved subjects time was less than 30seconds, in which case the
chewing sample food, and then the particle size surface area might be overestimated. There-
distribution of comminuted food was measured fore, the jelly should be rinsed for more than 30
with a series of mesh sieves. However, most of seconds to obtain an accurate value.
these measurement methods are complicated,and The concentration of glucose dissolved from
therefore, assessment is difficult during routine the jelly depended on both the temperature of the
chair-side work. In addition, reproducibility of distilled water and the dissolution time. A disso-
these sieving methods to determine particle lution time of less than 20seconds or a dissolu-
breakdown is poor and prone to experimental tion temperature lower than 30℃ made the glu-
error due to the complicated procedures . cose concentration unstable or too low to mea-
We have been utilizing test gummy jellies as sure using a blood glucose meter,probably due to
food for assessment of masticatory performance technical error. Therefore, in order to obtain
since 1993 . Evaluation using the jelly is based accurate and reproducible data, the temperature
on the calculation of the surface area increased and the dissolution time should be watched care-
by chewing, which was obtained by measuring fully.
the concentration of the glucose dissolved from Yamamoto already reported that the con-
the jelly. Previously, absorptiometry was used centration of gelatin dissolved from the test
to assess the quantity of gelatin extracted from gummy jelly correlated closely to the number of
the jelly. However, the absorbance meter was masticatory cycles. With respect to accuracy,
large and expensive, and the total measurement the regression analysis showed that the glucose
time took more than one hour,which is too long concentration and the surface area of the jelly,
for clinical use. To solve these problems, a which involved the physiological significance of
relatively cheaper and smaller commercially mastication,had a strong linear correlation,sug-
available blood glucose meter was selected for gesting this assessment could precisely calculate
this study. the masticatory performance.
M easuring Masticatory Performance Using Test Gummy Jelly 15

Dent 75:269-275, 1996.


7) Yamashita S, Sakai S, Hatch JP et al. Relationship
CONCLUSIONS
between oral function and occlusal support in denture
wearers. J Oral Rehabil 27:881-886, 2000.
1. The concentration of glucose dissolved 8) Lucas PW, Luke DA. Methods for analysing the
from comminuted particles of the test gummy breakdown of food in human mastication.Arch Oral
jelly indicated high reproducibility when the rins- Biol 28:813-819, 1983.
9) Gunne HS. Masticatory efficiency and dental state.
ing time, temperature of the distilled water, and
A comparison between two methods. Acta Odontol
dissolution time of the glucose were strictly pre- Scand 43:139-146, 1985.
scribed. 10) Lassauzay C, Peyron M A, Albuisson E et al. Varia-
2. The increase in the surface area of the bility of the masticatory process during chewing of
elastic model foods. Eur J Oral Sci 108:484-492,
comminuted test gummy jelly particles was accu-
2000.
rately calculated from the glucose concentration
11) Slagter AP, van der Glas HW, Bosman F et al.
dissolved from the jelly. Force-deformation properties of artificial and natu-
ral foods for testing chewing efficiency. J Prosthet
Acknowledgments:The authors greatly appreciated Dent 68:790-799, 1992.
the grammatical correction of the manuscript by Joanne 12) Buschang PH,Throckmorton GS,Travers KH et al.

M adsen, M .A. This research was partially supported by The effects of bolus size and chewing rate on mas-
ticatory performance with artificial test foods. J
a Grant of Health and Labour Science Research,Compre-
Oral Rehabil 24:522-526, 1997.
hensive Research on Ageing and Health, Tokyo, Japan
13) Huggare J,Skindhoj B.A new method for assessing
(H 15-longevity-002).
masticatory performance:a feasibility and re-
producibility study. J Oral Rehabil 24:490-495,
REFERENCES 1997.
14) Sato S,Fueki K,Sato H et al.Validityand reliability
1) Boretti G, Bickel M , Geering AH. A review of of a newly developed method for evaluating mas-
masticatory ability and efficiency. J Prosthet Dent ticatory function using discriminant analysis.J Oral
74:400-403, 1995. Rehabil 30:146-151, 2003.
2) Kimoto K, Ogawa T, Garrett NR et al. Assessment 15) Hayakawa I, Watanabe I, Hirano S et al. A simple
of masticatory performance―methodologies and method for evaluating masticatory performance
their application―. Prosthodontic Res Pract 3: using a color-changeable chewing gum.Int J Prosth-
33-45, 2004. odont 11:173-176, 1998.
3) M anly RS,Braley LC.Masticatory performance and 16) Yamamoto M.Evaluation of masticatory function in
efficiency. J Dent Res 29:448-462, 1950. complete denture wearers by masticatory efficiency,
4) Kapur KK, Garrett NR. Studies of biologic parame- electromyographic activities and mandibular move-
ters for denture design. Part II:Comparison of ment. J Osaka Univ Dent Sch 38:303-331,1993.(in
masseter muscle activity, masticatory performance, Japanese)
and salivary secretion rates between denture and 17) Okiyama S,Ikebe K,Nokubi T.Association between
natural dentition groups. J Prosthet Dent 52: masticatory performance and maximal occlusal
408-413, 1984. force in young men. J Oral Rehabil 30:278-282,
5) Hirai T, Ishijima T, Koshino H et al. Age-related 2003.
change of masticatory function in complete denture 18) Haraldson T, Carlsson GE. Chewing efficiency in
wearers:evaluation by a sieving method with pea- patients with osseointegrated oral implant bridges.
nuts and a food intake questionnaire method. Int J Swed Dent J 3:183-191, 1979.
Prosthodont 7:454-460, 1994. 19) Mahmood WA, Watson CJ, Ogden AR et al. Use of
6) Garrett NR, Perez P, Elbert C et al. Effects of image analysis in determining masticatoryefficiency
improvements of poorly fitting dentures and new in patients presenting for immediate dentures. Int J
dentures on masticatory performance. J Prosthet Prosthodont 5:359-366, 1992.

You might also like