Professional Documents
Culture Documents
02
URGENT
1. INTRODUCTION
There are several ways to update time on OmniPCX Enterprise:
− With external NTP server.
− With swinst menu.
− With network call through ABC-F inter node link.
− With Daylight Saving Time.
3. CONSEQUENCES
If the time was updated without restarting the system, a message on UA protocol can lead to a loop.
This loop will take all resources on CPU and CPU will crash.
During this loop, display on set will flicker. Some backtraces with incidents should occur on the system
involving digital sets equipments.
Backtraces:
* Backtrace: 0x083c501a:138170394 EBP 0x01806df0 --> send_pn_ua(void) (+18) 90%
* Backtrace: 0x08491611:139007505 EBP 0x01806df8 --> send_pn(void) (+161) 75%
* Backtrace: 0x08307b10:137394960 EBP 0x01806e04 --> lib_demi(void) (+780) 29%
* Backtrace: 0x083076c5:137393861 EBP 0x01806e88 --> li_demi(void) (+425) 98%
* Backtrace: 0x08e48c7f:149195903 EBP 0x01806e9c -->
updateTermTimeZoneIdleState(void) (+931) 95%
* Backtrace: 0x092b6d3a:153840954 EBP 0x01806ec0 --> real_main (+2586) 85%
1
TECHNICAL COMMUNICATION No. TC1279 Ed. 02
URGENT
Incidents:
1722=Aborted telephone task, PC 0x0934417b exc -10 neqt 1123
1602=IO1 driver error, full output link 25
Based of the number of sets impacted, theses messages can do saturation of IO1 virtual board
resulting by crash of the CPU.
4. SOLUTION
A restart of the CPU put back the system in normal situation.