NPC Metrology Laboratory CALIBRATION REPORT 201 Page 4 WP-ESD-TMD-019-036 April 24, 2019 Universal Test System’ PONOVO/Pw3361 PHig6121102 N/A V. Phase Angle Output Test Results sD. F . a eo © © © © o 30.00 * 1.00 30.0 0.0 30.0 0.0 60.00 * 1.00 60.0 0.0 60.0 0.0 90.00 * 1.00 70.0 20.0 70.0 20.0 120.00 + 100 120.0 0.0 120.0 0.0 150.00 1.00 149.9 oa 149.9 oa 180.00 1.00 179.9 oa 179.9 oa VI. Frequency Output Test Results RANGE UUT MEAS. AS FOUND (STD.) AS FOUND (STD.) SETTING vuNcERT. READING DEV. READING DEY. (Hz) (Hz) (mHz) (Hz) (Hz) (Hz) (Hz) 2000 45.000 + 0.225 45.00130 ~0.00130 45-00130 -0.00130 50.000 + 0.250 50.00030 -0.00030 0.00030 -0.00030 55.000 + 0.275, 55-00400 0.00400 55-00400 ~0.00400 60.000 + 0.300 60.00060 0.00060 60.00060 -0,00060 65000 + 0.995 65.0120 -0.00120 6 5.00120 —-0.00120 100.000 + 0.500 100.0160 -—-0.00160_—100.00160__-0.00160 iz) (mHz) (kHz) (kHz) (kHz) (kHz) 100.000 + 5.001 1.000002 -0.000002-—-1,000002 0.000002 ‘VII. Timing Test Results STANDARD MEASUREMENT AS FOUND (UUT) AS LEFT (UUT) READING UNCERTAINTY READING DEV. READING DEY. (Sec.) (Sec.) (Sec.) (Sec) (Sec.) (Sec) 3.1797 + 0.0001 3.1798 0.0001 3.1798 -0.0001 6.2308, - 0.0001 6.2310 0.0002 6.2310 -0.0002 9.1228 + 0.0001 9.1229 0.0001 9.1229 -0.0001 30.1594 + 0.0001 30.1595 0.0001 30.1595 -0.0001 60.2743 + 0.0001 60.2743 0.0000 60.2743 0.0000 90.2594 + 0.0001 90.2593 -0.0001 90.2593, 0.0001 Test Performed by: ‘Approved Gemelo L. Ballon Homer S. Galang ‘Technician PSD Manager PES-ESD-019- 024] 06 May 2019 Mr. BONIFACIO SANGALANG Engineering Manager EURO-ASIA ENERGY SOURCE INC. 24 Fir. No. 265 Unit N Cortes Bldg. Cor. Sct. Fernadez & Tomas Morato Sts., Brgy. Laging Handa, Quezon City Tel. No. (+632) 351-8243 SUBJECT : CALIBRATION REPORT OF EURO-ASIA TEST ISTRUMENT Dear Mr. Sangalang: Attached is the calibration report of your instrument that we had calibrated as covered by Work Package ESD-TMD-019-036. Report No. of i Serial No./ Tag | Number | Pages Instrument Description i Universal Test System, Ponovo 2019-036-001 | Model Pw336i PH146121102 ‘Again, we thank you for giving us the opportunity to serve your calibration needs. Very truly yours, Energy Services Department BIR Road cor. Quezon Avenue, Diliman Quezon City 1100, Philippines Nos. (632) 921-3541 to 80 + Fax No. (632) 921-2468 Website: wwrw.napocor.gov.ph NPC Metrology Laboratory CALIBRATION REPORT 2019-036-001 Page 5 of 5_ Reference: WP-ESD-TMD-019-036 Date: April 24, 201¢ OE ———E Description: Universal Test System Make: _PONOVO/Pw3361 SerialNo.: PH146121102 Tag No: N/A VIII. Auxillary DC Voltage Output Test Results F SUL Ser TS ee tcc SO neAPIC RIE CHE Se READING bey, w ™ ™) Ww) WW) W) 5.00 + 0.0002 4.97686 0.02314 4.97686 0.02314 10.00 + 0.0003 9.98275, 0.01725 9.98275 0.01725, 15.00 0.0008, 14.9860 0.0140 14.9860 0.0140 2400 0.0010 24.9940 -0.9940 24.9940 -0.9940 4800 0.002 48.0215 -0.0215 48.0215 -0.0215 0.00 + 0.006 110.049 0.049 110.049 -0.049 220.00 + 0.009 220.189 -0.189, 220.189 70.189 250.00 + 0.009 250.188 -0.188 250.188 0.188 Test Standards Description Tag No. Calibration Due Date Calibration Traceability _ Digital Multimeter, HP/3456A. 2L-DM6-02 8/8/2019 Ark One/NIST, ITDI/NML Universal Counter, HP/5315A. 3L-UNC-o2 5/8/2019 Keysight/ NIST Solid State Timer, Multiamp/SST-2E_ 3L-SST-o1 7/3/2019 ITDI/NML La ae ae 2L-SH-02 8/10/2019 ‘Ark One/NIST, ITDI/NML. Phase Angle Meter, Multiamp/1754-E 3L-PAM-o1 3/5/2020 aed pl Test Conditions: Temperature: 23 +2 °C Relative Humidity: < 70% RH Test Methods: 1, TT&VITI- Measurement of the UUT's voltage output using a Digital Multimeter, HI& IV- Measurement of the UUT's current output using Shunt-Voltmeter Method. V- Measurement of the UUT's phase angle output using a Phase Angle Meter. VI- Measurement of the UUT's frequency output using a Universal Counter. ‘VII- Comparison of the UUT timer reading against the reading of a Solid State Timer. Remarks: ‘Tolerance Specification of the instrument is not available. Declaration and Notes: 1. This report applies only to the instrument identified above (Make, Model, TagNo., and Serial No.), and the data contained herein are those that were obtained at the time of calibration. 2. This report may be reproduced only in full and with the permission from this Laboratory. 3. The quoted uncertainty of the standard value is obtained at 95% confidence level. Test Performed by: Reviewed by: Approved by/) ama on Castro Ho) it Technician’ PrinGipal Engineer C D Manager NPC Metrology Laboratory CERTIFICATE OF CALIBRATION CERTIFICATE NO.: 2019-036-001 for Universal Test System Ponovo Model Pw336i Serial No.: PH146121102 Submitted by: EURO-ASIA ENERGY SOURCE INCORPORATED 2nd Fir. No. 265 Unit N Cortes Bldg. Cor. Sct. Fernadez & Tomas Morato Sts., Brgy. Laging Handa, Quezon City This certifies that the instrument was calibrated by comparison against the standards maintained by the NPC-Central Metrology Laboratory using procedures PES-ESD-PM-012- WI-o11, PES-ESD-PM-012-WI-018, PES-ESD-PM-012-WI-020, PES-ESD-PM-012-WI-021 and PES-ESD-PM-012-WI-031. The standards used aretraceable to the National Metrology Laboratory of the Department of Science and Technology and to the National Institute of Standards and Technology through Keysight Technologies and Ark One Solutions, Inc. ‘The test data in the attached Calibration Report were those obtained during the time of calibration. Itis the responsibility of the user to determine the suitability of the instrument for its intended use. HOMER S. GALANG Manager Testing and Metrology Services Division Date: 06 May 2019 Page 10f 5 Quezon Avenue corner BIR Road, Diliman, 1100 Quezon City, Philippines ‘Tel. Nos. (632) 921-3541 t079 © ‘Fax No. (632) 923-2468 P.O. Box 10183 ‘Website: www.napocor.gov:ph NPC Metrology Laboratory CALIBRATION REPORT 2019-036-001 Page _2 of 5 Reference: WP-ESD-TMD-019-036 Date: il 24, 201 Description: “Universal Test System Make: _PONOVO/Pw3361 TagNo.: N/A Serial No: PH1q6121102 1. AC Voltage Output Test Results uur MEAS. AS FOUND (STD.) AS FOUND (STD.) CHANNEL — SETTING ——_UNCERTT. READING DEV. READING DEY. etter) w wo w w wo wo NA 40.000 0.098 39.7559 o.24at 39.7559 0.2441 80.000 + 0.126 79.5103 0.4897 79.5103 0.4897 320.000 + 0.784 119.2681 0.7319 119.2681 0.7319 NB 40.000 + 0.098 39.7609 0.2301 39-7609 0.2301 80.000 = 0.126 79.5123 0.4877 79.5123 0.4877 120.000 0.784 119.2691 0.7309 119.2691 0.7309 NC 40.000 = 0.098 39.9496 0.0504 39.9496 0.0504 80.000 = 0.126 79-8738 0.1262 79.8738 0.1262 120.000 = 0.784 119.7830 0.2170 119.7830 0.2170 NZ 40.000 = 0.098 39.7836 0.2164 39.7836 0.2164 80.000 + 0.126 79-5505, 0.4495 79-5505 0.4495 120.000 + 0.784 119.3121 0.6879 119.3121 0.6879 T, DC Voltage Output Test Results uur MEAS. AS FOUND (STD.) AS FOUND (STD.) CHANNEL SETTING ——_UNCERT. READING DEV. READING DEY. Getter) wo (mv) w) wo w w NA 50.000 + 1.750 49.6509 0.3491 49.6509 0.3491 150.000 + 6.750 149.079 0.921 149.079 0.921 NB 50.000 * 1.750 49.6561 0.3439 49.6561 03439 150.000 = 6.750 149.096 0.904 149.096 0.904 NC 50.000 * 1.750 49.9065 0.0935 49.9065 0.0935 350.000 + 6.750 149.746 0.254 149.746 0.254 NZ 50.000 * 1.750 49.6499 0.3501 49.6499 0.3501 150.000 * 6.750 149.042 0.958 149.042 0.958 Test Performed by: Approved OL. B: ween Technician NPC Metrology Laboratory CALIBRATION REPORT 2019-036-001 Page 3 of _5 Reference: _WP-ESD-TMD-019-036 Date: April 24, 2019 Description: Universal Test System Make: PONOVO/Pw336i SerialNo.: PH1g6121102 TagNo.: N/A MI. AC Current Output Test Results uur MEAS AS FOUND (STD.) AS FOUND (STD.) CHANNEL — SETTING ——_UNCERTT. READING DEV. READING DEV. etter) @ (ma) ww w ww @ NA 5.000 = 21.03 5.0069 -0.0069 5.0069 -0.0069 10.000 + 24.59 10.0095 -0.0095 10.0095 -0.0095 15.000 28.18 15.0134 -0.0134 15.0134 -0.0134 20.000 + 31,79 20.0189 -0.0189 20.0189 -0.0189 NB 5.000 + 21.03 5.0051 -0.0051 5.0051 -0.0051 10.000 24.59 10.0054 -0.0053 10.0054 -0.0053 15.000 = 288 15.0080 -0.0079 15.0080 -0.0079 20.000 = 31.79 20.0106 -0.0105 20.0106 -0.0105 Nc 5.000 = 21.03 5.0063 -0.0063 5.0063 -0.0063 10.000 24.59 10.0090 ~0.0090 10.0090 -0.0090 15.000 = 288 15.0119 -0.0119 15.0119 -0.0119 20.000 + 31.79 20.0155 -0.0155 20.0155 -0.0155 IV. DC Current Output Test Results uur MEAS, AS FOUND (STD) AS FOUND (STD) CHANNEL — SETTING ——_UNCERT. READING DEV. READING DEV. _Catter) es) (ma) ww w @ w NA 5.000 = 1.092 4.9938 0.0062 4.9938 0.0062 20.000 + 4.296 20.0101 -0.0101, 20.0101 -0.0101 NB 5.000 = 1.092 4.9946 0.0054 4.9946 0.0054 20.000 + 4.296 19.9985 0.0016 19.9985 0.0016 5.000 = 1.092 4.9930 0.0070 4.9930 0.0070 20.000 + 4.296 19.9967 0.0033 19.9967 0.0033 Test Performed by: Reviewed by: wee) ea xi elo L. Ballon R. Castro Hofer Technician Pabebal Engineer C FASD Manager

You might also like