You are on page 1of 13

PT321 GENERAL FEATURES 8 Filling Modes

• Up to 1600 measurements per second • Open container filling in Gross mode,


PT321 COMPACT • 16,000,000 internal resolutions • Open container filling in Net mode
(taring container weight off),
• Up to 999999 scale divisions
FILLING • OIML R76 Approved to 10000e • Up to • Drum filling through the bung hole in
Gross mode.,
8x 350 Ω load cells
CONTROLLER • 8 filling modes.
• Drum filling through the bung hole in net
mode (taring container weight off),
• Totalling
• Packing/bagging with pre-weigh hopper,
• Ergonomic design with small size
• Multi-cycle packing/bagging with pre-
• 13.5 mm LED display weigh hopper,
• Multiple units (kg, lb) • Weigh out (subtractive) batching with
• vCal Electronic calibration hopper topup (recharge),
• Linearity correction • Bag filling/packing directly into the bag.
• Gravity compensation adjustment SYSTEM INTEGRATION
• Programmable via PC
• Ethernet TCP/IP, Ethernet/IP
• RS-232C & RS-485 serial interface standard
• Modbus RTU, Modbus TCP
• Modbus RTU on all instruments
• Profibus
• 12 - 28 VDC supply
• Profinet
• 4 isolated inputs, 5 Relay outputs
• CANopen
• CC-Link
PT321 SPECIFICATIONS
ACCURACY OIML R76 Class III 10000 scale intervals
DISPLAY 6 digits, 7 segments red LED, 13.5 mm high
RESOLUTION Max. Displayed 999999 (non-approved), internal 16000000, 24 bit Delta Sigma ADC
CONVERSION RATE Up to 1600 times per second
UNITS DISPLAY kg, lb Metric/Imperial
DISPLAY ANNUNCIATORS Gross, net, motion, centre of zero, units
KEYPAD (with access lock) 5 key (user assignable Function, G/N, Tare/Clear, Zero, Print )
LINEARITY ERROR, TEMP. < 0.0015% FSO, < 2 ppm/ºC
COEFFICIENT
EXCITATION 5VDC 125mA, up to 8x 350Ω or 16x 700Ω load cells, 4 or 6 wire, maximum 1000 m/mm2
INPUT VOLTAGE RANGE AND --18 mV to +18mV, 0.4 μV/d (approved); 0.1μV/d (non approved )
SENSITIVITY
ZERO ADJUSTMENT RANGE -18 mV to +18mV
OPERATING ENVIRONMENT -15 ºC to +55ºC; max. 85% RH (80% RH, -10~40ºC approved), non-condensing. IP65 sealing.
ENCLOSURE AND DIMENSIONS Stainless steel front panel, aluminium casing, stainless rear. 100mm x 55mm panel, 100mm deep.
1/8DIN cutout.
POWER SUPPLY FEATURES 12-28 VDC max., 300mA.

CALIBRATION Calibration can be performed with or without load cell non-linearity correction.
Calibration with test weights, Electronic calibration without test weights, Temporary zero
calibration, Zero adjustment, Gain adjustment.
DIGITAL FILTER Adaptive digital filter adjustable in 10 steps.

• Powerlink
• EtherCAT

...Azure Signature Series!


The PT321 is a smart controller for industrial weigh filling applications, offering 7 filling
modes, powerful PLC integration facilities, standard serial ports (RS-232C, RS-485),
Modbus and other optional fieldbus protocols.
The PT321 series is approved by Weights & Measures Authorities for use in Accuracy
Class III applications with 10000 scale intervals in accordance with OIML R76.
Powerful calibration options including vCal (Electronic calibration without test weights)
which supports fast easy setup and service. The PT321 features adaptive filtering for fast
settling, high display resolution and a speed of up to 1600 conversions per second.
It’s small sized aluminum body is perfect for panel installations, providing a big display and
requiring little space on control panels. The instrument has a stainless steel front for use in
harsh environments.

Accupoint weigh module

PT Limited
2 /7 Marken Place, Glenfield, Auckland 0627, New Zealand
PO Box 102041 NSMC, Auckland 0745. Ph.+64 9 444 4312
www.ptglobal.co m
Rev.1707.2
FILLING FUNCTIONS 8 filling modes to cater for most filling operations.
TOTALLING Totalling to provide a total of filling activity
COMMUNICATION

RS-232C 1200 to 115200 baud, programmable. Continuous, Printer, BSI. Available on all models
RS-485 (Modbus RTU) 1200 to 115200 baud, 7/8-E/O/N-1. Up to 31 stations. Available on all models
Ethernet TCP or Modbus TCP 10 Mbit/s (half duplex), galvanically isolated
Ethernett/IP 10 /100 Mbit/s, full or half duplex
PROFIBUS PROFIBUS DP V1. 9.6 kbit/s to 12 Mbit/s automatic baud rate detection
PROFINET 100 Mbit/s (full duplex), galvanically isolated
CANopen 10 kbit/s to 1 Mbit/s automatic baud rate detection
EtherCAT 100 Mbits/s, full duplex.
CC-Link 156 kbits/s – 10Mbits/s (selectable ).
Powerlink 100 Mbits/s, half duplex.
DATA OUTPUT Demand (BSI), Continuous and Fast Continuous, Fieldbus (model dependent).
PRINTING/WEIGH TICKET
TICKET FORMAT Single line or multi-line. Ticket weighing number can be Preset.
DATE FORMAT Programmable as dd.mm.yyyy, mm.dd.yyyy or yyyy.mm.dd
PRINT LANGUAGES English, German, French, Italian, Spanish, Turkish
PT Limited
2 /7 Marken Place, Glenfield, Auckland 0627, New Zealand
PO Box 102041 NSMC, Auckland 0745. Ph.+64 9 444 4312 www.ptglobal.com
PT5100 Series-Order Codes

Dimensions in mm and kg.


Capacity Order A B C D E F G H K L P Weight(kg)
500kg 51M0500S000XXX 16.0 25.4 76.2 130.0 30.8 30.8 13.5 M12 x 1.75P 16.0 57.2 13.5 1.14
1000kg 51M1000S000XXX 16.0 25.4 76.2 130.0 30.8 30.8 13.5 M12 x 1.75P 16.0 57.2 13.5 1.14
2000kg 51M2000S000XXX 16.0 25.4 76.2 130.0 30.8 30.8 13.5 M12 x 1.75P 16.0 57.2 13.5 1.14
3000kg 51M3000S000XXX 19.0 38.1 95.3 171.5 38.1 38.1 20.5 M20 x 2.5P 19.0 76.2 20.5 1.94
5000kg 51M5000S000XXX 19.0 38.1 95.3 171.5 38.1 38.1 20.5 M20 x 2.5P 19.0 76.2 20.5 1.94

Specifications
Signal Output at Capacity.....................2±0.005mV/V Service Load...........................100% Capacity
Linearity Error......................................< 0.020% FSO Safe Load...............................150% Capacity
Non-Repeatability.................................< 0.010% FSO Safe Side Load.......................100% Capacity
Combined Error....................................< 0.020% FSO Ultimate Load..........................300% Capacity
Hysteresis............................................< 0.020% FSO Input Resistance.....................350 ± 3
Creep/(30 mins.)..................................< 0.020% FSO Output Resistance..................350 ± 3
Zero Balance........................................< 1 % Capacity Insulation Resistance..............> 5000 M (@50 VDC)
Temperature Effect on Span(/10C).......< 0.015% FSO Excitation Voltage(Rec)...........5~15 V AC/DC
Temperature Effect on Zero(/10C)........< 0.015% FSO Excitation Voltage(Max.).........18 V AC/DC
Operating Temperature Range.............-20 ~ 65 C Cable......................................6m Dia. 4.5~5.0 mm
Storage Temperature Range................-50 ~ 85 C Material...................................17-4PH Stainless Steel
Excitation +ve.......................................RED Excitation -ve..........................Black
Signal +ve............................................GREEN Signal -ve...............................White
 Construction is welded stainless steel sealed to IP68

Rev. 2 20090707
PT100SBS
STAINLESS STEEL SUMMING BOXES

Features
• Stainless steel construction
• Protected from water ingress
with a rubber seal.
• External fixing means no
penetrations for mounting
• Solid earthing terminal
• Liquid tight glands for cables 6.5
to 9mm.
• Individual load cell adjustments.
• Built in surge arrestors on the
PT1 SBS-8

...Azure Signature S33eries!

The PT1 SBS summing boxes are high quality summing boxes with individual
load cell adjustment for the weighing industry with a durable stainless steel
housing.
Fitted with liquid tight strain relief cable fittings. The PT1 SBS accepts a wide
range of cable diameters.
Enclosed in a tough stainless steel housing, easily accessible yet securely closed
and positively sealed by way of it's screw on cover and external fixing holes.
Designed and produced for the installer, with jumpers for summing without
attenuation and simple to reach and positive control trim pots for load
measurement correction.
The 8 way also contains surge arrestors appropriate for weighbridge and large tank
and silo installations.
Specifications
Cable Inputs with cable diameter 6.5 to 9mm. Connection to the indicator with 6 wire configuration
with cable diameter 6.5 to 9mm.
Adjustment Trim potentiometer with 2 Ω adjustment in excitation +ve of each load cell and jumper for
summing unmodified signals.
PT100SBS-4
Inputs Input for 4 load cells or strain gauge transducers using 4 wire connection
Physical 14 mm x 14 mm x 47mm, IP66, stainless steel construction
PT100SBS-8
Inputs Input for 8 load cells or strain gauge transducers using 4 wire connection
Physical 23 mm x 18 mm x 7 mm, IP66, stainless steel construction

Items Available
Model Features
PT1 SBS-4 Stainless steel summing box with 4 load cell inputs

PT1 SBS-8 Stainless steel summing box with 8 load cell inputs

http://www.ptglobal.com
LOAD CELL JUNCTION BOX
CORNERING INSTRUCTIONS
DESCRIPTION
Cornering refers to adjusting each load cell to match sensitivity and show the correct weight no matter
where on the scale the load is applied. The PCB with connections and adjustments is housed in an IP66
sealed stainless steel box which should be securely mounted. There is an earth terminal on the casing that
should be connected if the structure does not provide adequate earthing. For best surge protection in the
PT1 SBS-8 connect this terminal to earthing rods suitable for lightning protection. The load cell cables are
connected to individual 5 way terminal blocks and each load cell connection is provided with a trim pot for
cornering adjustment and a jumper. The junction box supports the connection of a 6 wire indicator cable to
facilitate reference return via the 7 way terminal block for the indicator cable. The trim pot(entiometer)
adjustment provides up to a maximum of 4.2% of cornering adjustment for a 35 ohm load cell. If cornering
adjustment is not required then the adjustment pots can be made inoperative by fitting jumpers to between
terminals JNadj. If 6 wire load cells are to be used connect the load cell sense wires with the excitation
wires (+ve to +ve, -ve to -ve) into the appropriate excitation terminal.

Note: Indicator calibration by direct mV/V entry cannot be performed unless the jumpers are in the Jnadj
position, meaning that corner trimming cannot be performed as this would alter the mV/V.
Summing board components

Cornering
adjustment
potentiometers

Surge arrestors
(PT1 SBS-8 only)
Jumpers

CORNERING ADJUSTMENT
1. Before calibration starts ensure that all jumpers are in the Jadj position and that all trim pots are adjusted so
that they are not influencing the cornering. This is achieved by turning the pots fully anti-clockwise at least 2
turns or until the end stop is reached indicated by a clicking sound.

2. As the trim pots are turned clockwise they will reduce the load cell output. Place the cornering load on all four
corners in turn and note the highest reading. Turn the appropriate trim pot clockwise to reduce the highest
reading until it is the same as the lowest corner. (R1 for load cell 1, R2 for load cell 2, R3 for load cell 3, etc.)

3. Repeat the adjustment as necessary for the other corners until all corners read the same weight when the
cornering load is applied.
Rev.180516

http://www.ptglobal.com
VALVULA DE CORTINA (CUCHILLA) DE 8” CON ACTUADOR
NEUMATICO.
CUCHILLA: ACERO INOXIDABLE
ACCIONAMIENTO: MEDIANTE VALVULA DE SOLENOIDE CON
ACCIONAMIENTO MANUAL Y ELECTRICO
CILINDRO NEUMATICO DE DOBLE ACCION, ACCIONADO CON
VALVULAS DE SOLENOIDE DE 3 VIAS, 2 POSICIONES
ARREGLO DE CUATRO CILINDROS OPERADOS
SIMULTANEAMENTE.
OPERACIÓN AUTOMATICA Y MANUAL SEGÚN ELIJA EL
OPERADOR.

VALVULA NEUMATICA DE SOLENOIDE 5/2


CON ACCIONAMIENTO MANUAL Y
ELECTRICO

You might also like