You are on page 1of 88

Monitoarele ULTRA au TL494C 1 Mohm pinul 15 la masa

http://english.electronica-pt.com/lcd-repair

AT1741 -15 -LED GROUND


BA9741-15 -LED GROUND
BD9211F-14-4k7
BD9215AFV -15 -10K GROUND
BD9222FV -13 -LED GROUND
BD9240-15 -10K GROUND
BD9270F-13-10K
BD9275F-11-1K
BD9276EFV-35-LED
BD9766CVF -20 -LED GROUND
BD9766VF -20-LED
BD9777-14-10K GROUND
BD9882F-14 -LED GROUND
BD9893F-10-82K
BD9896-3-LED
BD9897F-22-LED GROUND
BD9897FS-17-LED GROUND
BI3101A-16 -470 oHM
BIT 3101-2&15 SHORT
BIT3102B-14-47K
BIT3105-19-LED
BIT3193-5-LED
BIT3251/52- 5-GROUND
BIT3713 -5-LED GROUND
DT8211-9-47K
FA3629-15&16SHORT
FA3630-7&10SHORT
FAN7316 -17-LED
ILN816GN-8-10K
KA7500-1&16 SHORT
KA7500B-15&16 SHORT
KHO803A-5-LED OR 390K-820K
LM2901-6-82K
MAX8722-4-DIRECT GROUND
MP1006-6-10K
MP1007ES-4-DIRECT GROUND
MP1008-4-10K GROUND
MP1009-5-DIRECT GROUND
MP1038EY-2&11 SHORT
MP1060EF-3-LED
MP3810-6-82K
MSC1692-4-220K
OB3316QP-DIRECT GROUND
OB3362RP-16-22K
OZ5508G/GN/N-3-LED
OZ964-4-LED
OZ9643-1-20K
OZ9643N-20 ohm
OZ965-4&5 SHORT
OZ972GN-8-LED
OZ9910-5-82K
OZ9919GN-8-10K GROUND
OZ9937-14-47K
OZ9938-3-10K
OZ9938GN-3-GROUND
OZ9938Q-3-10K GROUND
OZ9939GN-3-100K
OZ9966SN-15-10K GROUND
OZ9972(24-PIN)-20-1K
OZ9976-11-10K
OZL68GN-4-LED
OZL68GN-4&7 SHORT
OZT1060GN-1-LED GROUND
SEM2005-1-LED
SEM2005-1-82K
SEM2006-5-GROUND
SEM2107-21-LED
SS1091ASN-19-LED
SSL110SN-19-GND
TA9687GN-12-47K GROUND
TL1451-15-DIRECT GROUND
‌TL494-1&16 SHORT
SEM2105 Remove Protection

Removing Protection Electrical Diagram Image

Connect LED from pin 1 to


ground.

AT1741 Remove Protection

Removing Protection Electrical Diagram Image

Connect diode from pin 15 to


ground.

BA9741F Remove Protection


Removing Protection Electrical Diagram Image

Connect pin 15 to ground.

BD9897FS Remove Protection

Removing Protection Electrical Diagram Image

Led between Pin 17 and ground


turn off protection

BIT3102A Remove Protection


Removing Protection Electrical Diagram Image

Option1: Pin 6 need 2,5V to


turning off protection, Connect
resistor from pin 6 to ground.

Option 2: Pin 5 on air.

BIT3193 Remove Protection

Removing Protection Electrical Diagram Image

Option 1:When the voltage on pin


5 is 0,4 to 2,4V and the command
"start" PWM operates
autonomously, the lamp does not
turn off.Connect led from PIN 5
to ground

Option 2: Pin 15 On Air

BIT3713 Remove Protection


Removing Protection Electrical Diagram Image

Connect LED from pin 5 to


ground.

FAN7311 Remove Protection

Removing Protection Electrical Diagram Image

Pin 1 (OLP - Open Lamp


Protection) resistor with 560 Ω
from pin 1 to ground.

FAN7314 Remove Protection


Removing Protection Electrical Diagram Image

Pin 1 (OLP - Open Lamp


Protection) resistor with 560 Ω
from pin 1 to ground.

OZ960 Remove Protection

Removing Protection Electrical Diagram Image

Pin 4 (SST - Soft-Start Time) at


the moment you need to keep 1,8
to 2V.

OZ964 Remove Protection


Removing Protection Electrical Diagram Image

Pin 4 (SST - Soft-Start Time) at


the moment you need to keep 1,8
to 2V.

TL5001 Remove Protection

Removing Protection Electrical Diagram Image

Connect LED from pin 5 to


ground.

Model description of the chip to protect the foot


TL5001 5-to-ground short circuit
TL1451 15-to-ground short circuit
TL5451 15-to-ground short circuit
BA9741 15-to-ground short circuit
BA9743 15-to-ground short circuit
MB3775 15-to-ground short circuit
AT1741 15-to-ground short circuit
AT1380 2-to-ground short circuit
KA7500 1 and 16-to-ground short circuit
TL494 1 and 16-to-ground short circuit
FA3629 15 and 16 will short-circuit external capacitor
FA3630 7 and 10-to-ground short circuit
OZ960 OZ962 2-to-ground short circuit
OZ965 4-to-ground short circuit
OZ9RR 8-to-ground short circuit
BIT3101 2 and 15-pin suction air
BIT3102 5 emptying pin
BIT3105 4 pin suction air
BIT3106 4-pin and 27 suction air
BIT3107 4 pin suction air
BIT3193 15 pin suction air
AAT1100 8-to-ground short circuit
AAT1107 15-to-ground short circuit

http://translate.googleusercontent.com/translate_c?
depth=1&hl=ro&rurl=translate.google.ro&sl=ru&tl=en&u=http://monitor.net.ru/forum/topic239071-
0.html&usg=ALkJrhhj-mySUUYNsMu4dIV06KGFiKa7jQ

Rottor 16-09-2008 18:46


Guest
87.69. *. OZ960 chip was necessary to remove the protection from the inverter.
* Price of the issue:
1 - to provide a simple circuit design means the inverter with a transformer for
operation without a faulty transformer, with the minimum required number of lamps.
2 - the inverter simple circuit design means when disconnecting the faulty lamps.

- Perhaps there is a reference to business information, to me personally on this subject


on the Internet is nothing concrete has been found.

The approximate scheme (for discussion) here:


OZ960D variant.rar 377.66 KB Downloaded: 13582 time (s)

KRAB 16-09-2008 19:31


monitor.
net.ru Rottor wrote:
provide a simple circuit design means the inverter with a transformer for
Posts: operation without a faulty transformer, with the minimum required number
14071 of lamps.
- Alex, just remove the faulty lamp with assemblies and so include:
http://monitor.net.ru/forum/viewtopic.php?t=151397&postdays=0& ... (17.04.2007
ten sixteen) - parallel and pomotret overheating trance - IMHO, should be enough
reasons (C6 (C34) to adjust (remove)).

Added 16.09.2008 19:37

http://www.d43d.ru/modules.php?name=Content&pa=showpage&pid=33 - here's a
couple of circuits with a brief description of it.
slap 16-09-2008 19:47
Party
Posts: Rottor,
342
Aleh I disconnect the faulty lamp installation of capacitors instead of the lamp.
The order of 1000-2000 pF about 2 kilovolts. The exact denomination is possible to
choose a particular LSD.
"Deceived" for many inverters - returns were not.
Can be made equivalent to the resistors, but it turns out it is very large.
A capacity enables you to do all compact.
KRAB 16-09-2008 19:53
monitor.
net.ru slap, the question is, as I understand that one of the trance "killed" and equivalents
lamps examined the link above
Posts: KRAB wrote:
14071 You can still share some thoughts about the equivalent of lamps. Someone
uses (recommended)
1. Resistors: "... 100k 2-10VT power ...." - cm. And "priveshenny" file.
2. The high-voltage capacitors "... 3 kV capacitor 33-47pF ..."
3. For example, I used a 20-watt fluorescent lamp (lamps from China) with
closed terminal of each "spiral" ignition.

and here: http://monitor.net.ru/forum/viewtopic.php?t=210346 (09.07.2008 twelve


seven)
Strike 16-09-2008 19:56
idiot
Posts: It was not possible yet, but I think on this scheme, (after removal of the defective
2177 portion of) the selection of R18 should be set to the desired security mode.
If this same circuit occurs uchaske and metering (adjustment) voltage in the "Settings"
enter R19 and R15.
More feedback can not see.
Select the capacity to overcome believe -risk for trance elements desired mode is
already set, it remains correct swinging power circuit.
But would not be pumped.
Rottor 16-09-2008 19:58
Guest
87.69. *. KRAB, If you remove (at fault) or lamp transformer - fire protection, turn off the
* entire block of the inverter.
As an option you must provide a job:
1 - with two transformers and three-defective lamps
2 - one transformer is necessary to ensure proper illumination of the work on the three
lamps.
3 - light "flashing" or "red" lights on "maximum" brightness.
Approximate inverter circuit with this file: http://monitor.net.ru/forum/95-download-
10638.html

Added 16.09.2008 19:08

Strike, Thank you for your participation.


Just for the sake of God without it.
Strike wrote:
... Correct swinging power circuit.
... Not to pump.

I'm in this area lamEr, so I was only interested in specific settings, and for adults.
KRAB 16-09-2008 20:16
monitor.
net.ru Rottor wrote:
1 - with two transformers and three-defective lamps
Posts: - Instead of the 4th lamp - equivalent (the links above - from Andrew andros).
14071
Rottor wrote:
2 - one transformer is necessary to ensure proper illumination of the work on
the three lamps.
- IMHO - not work - power tr-ra is not enough.
Rottor wrote:
3 - light "flashing" or "red" lamp at maximum brightness.
- ??? - May produce heat and failure of key assemblies.

Alex, this is a specific target for this type of "inverter OZ960", or just need a TV
version of "powering" existing in a matrix of light - so then just another type of
inverter is ready to take?
Strike 16-09-2008 20:39
idiot
Posts: ?.
2177 I'll try ..
If the above scheme 1, then selecting R18 upward failure protection is achieved
because the after removal of faulty trance removes the additional voltage source for
the feedback.
Or as an option - will integrate ostsyllogram point (45) is carried out, this may be
enough.
Rottor 16-09-2008 20:44
Guest
87.69. *. KRAB wrote:
*
1 - instead of the 4th lamp - equivalent (the links above - from Andrew
andros).
2 - IMHO - not work - power tr-ra is not enough.
3 - is a particular challenge for this type of "inverter OZ960"

1 - Read about the different "emulators" including the load resistor, tried in practice -
for me not aktualtno.

2 - Why is not enough - trans quietly "shakes" four - six lamps with optimum
brightness.
If necessary, you can reduce the total power, luminous flux (brightness) with an ample
margin.

3 - In this instance, to discuss options, my problem has been solved independently, but
would like to get the information for free.
Tried at the time to "discuss" about it in the "Monitoring" section of the forum - but
there are steep "pro" smoothed out all the messages.
May still have time popizdet on this topic here, to the third warning, followed by
"indefinite ban."

Added 16.09.2008 19:51

Strike wrote:
If the above scheme 1, then selecting R18 upward failure protection is
achieved,

I can say straight away - manage security on pins 2, 9, 10, by simple means (such as
the selection of the resistor) is not possible.
At least I did not.
In the archives of different forums, taking into account long-term practice of repair, I
found nothing.
However, maybe information is not available or I casually looking for.
PAI 17-09-2008 9:39
Master
Posts: Rottor wrote:
1342
1 - to provide a simple circuit design means the inverter with a transformer
for operation without a faulty transformer, with the minimum required
number of lamps.

Bypass trans (roughened) has never failed.


Rottor wrote:
2 - the inverter simple circuit design means when disconnecting the faulty
lamps.

For lamps up to 17 "- load 270pik from 19" - 470pik. Load tested for years. No return.
Rottor wrote:
If you remove (at fault) or lamp transformer - protection trips, the inverter
shuts down the entire block

Therefore it is necessary to put in Conder parallels faulty lamp. This is for options-
Rottor wrote:
with two transformers and three-defective lamps

Rottor wrote:
2 - one transformer is necessary to ensure proper illumination of the work on
the three lamps.

This is an interesting option. I'll try. Good is the ward for the experiment.
Rottor 17-09-2008 10:00
Guest
89,138. PAI, Ok!
*. * This indirect ways - "emulation" is equivalent to maintaining a regular mode circuits -
Protection continues to work.
I read about it on various forums, you have to "monitor" is a topic where it is
established by Directive moderator.

You do not have information on ways to incorporate chip (s) in order to disable the
protection and transfer it in the "manual" mode is controlled?
LARTE 17-09-2008 19:42
R
Mozgop Rottor, he tripled his foot looks protection diodes sealed-off from the trance that was
rav dead and everything should work.

Posts:
3477
Rottor 17-09-2008 19:52
Guest
87.69. *. LARTER wrote:
*
... And everything should work.
Your prayers?
Rottor wrote:

I can say straight away - manage security on pins 2, 9, 10, by simple means
(such as the selection of the resistor) is not possible.

A processor (PWM) inverter detects a failed or overloaded lamp and goes into
protection?
LARTE 17-09-2008 19:56
R
Mozgop Rottor, on the second scheme, one transformer, one lamp, 9i10 foot m / s looking for
rav ignition and support of indigenous and second overall protection of the inverter when
neispravnogsti any of the lamps.
Posts:
3477

Rottor 17-09-2008 19:57


Guest
87.69. *. LARTER,
* You tried it?
You did?

LARTE 17-09-2008 20:04


R
Mozgop Rottor wrote:
rav
LARTER,
You tried it?
Posts: You did?
3477

Yes, not on a specific chip, but the exact same circuitry, the diode sealed off and it
stops svalivatsya in defense on the channel on which it stands. Even if the keys are to
blame trans swing, m / s will not see the error and will work. According to datasheet 2
output is called OVP (protection).
Here it vnutrinney.

Rottor 17-09-2008 20:20


Guest
87.69. *. LARTER wrote:
*
... M / s will not see the error and will work.

Your opinion is inconsistent with the specific work "m / s", read carefully the topic.

I asked without projects is under the control of consciousness and pizdobolstva on an


unconscious level.
LARTE 17-09-2008 20:21
R
Mozgop Rottor, nikokogo pizdobolstva, this was done many times in many devices.
rav

Posts:
3477

Rottor 17-09-2008 20:23


Guest
87.69. *. LARTER,
* Trandish!
Crawl.

LARTE 17-09-2008 20:25


R
Mozgop Rottor, I do not understand what you want to hear more, and it is achieved by the
rav inverter? disable protection and the channel does not work.

Posts:
3477

KRAB 17-09-2008 20:30


monitor.
net.ru LARTER wrote:
and called OVP
Posts: - Have not tried it, but - if this input is just generally physically "cut off" on it imitated
14071 the required level - is not it start? No full datasheet

Rottor 17-09-2008 20:59


Guest
87.69. *. KRAB,
* It makes no sense to discuss the option to sue to protect conclusion 2, from the
beginning I have to report that this is a dead end road.
In some embodiments, the chip enable pin 2 is not involved at all, the protection
works without OVP.

I'm interested in the opinion of those who specifically faced with the problem -
remove the protection, that is to provide the operating mode chip circuit design
method, for example, without tripping feedbacks watering parts manufacturing
"emulators".

Datshit chip on the bottom

OZ960 Pdf.rar 123.02 KB Downloaded: 4265 time (s)

alex3 17-09-2008 22:44


Party
Posts: I think enough to pin 10 (CMP) of the error amplifier output voltage is limited so that
2086 it neprevyshalo 2,75v,
conventional zener probably should have.
I myself almost neproboval on occasion to taste.

Rottor 17-09-2008 22:57


Guest
87.69. *. alex3,
* The direction is correct, but there is no such swill stress.
But need another threshold "minimum."
Protection complicated algorithm, and a threshold with a "window."
How to decrease and increase of the voltage across the terminals above or below the
specified voltage causes a trigger lock PWM processor.
Implement a zener will not work.
alex3 17-09-2008 23:14
Party
Posts: Rottor, with the English I have really bad so that I could see from the datasheet so
2086 this upper threshold 2,75v,

and when it is lower then the threshold can be made so. divider vystavlyaetsya lower
threshold. Zener ogranichivaetsya top.

Posted 18-09-2008 00:29

and the voltage at the divider probably better served from 7 O (Reference voltage
output; 2.5V typical)

prof75 18-09-2008 4:18


San
Sanych Rottor, in theory, in the absence of a trance inverter OZ960 should work. Anyway, in
Posts: the inverter with 8 trans (also on the basis of OZ960, see. Photo) when you turn off
520 the two neighboring shemales everything else works fine. It is checked repeatedly. A
protection is likely triggered by exceeding naprugi 1.25V on the 9th output FB. This
excess will be in the absence of the lamp, but if you remove the trans, it will be more
than just a nobody Alternatively, you can disable the R23.
PICT0002.packed.JPG 78.96 KB Downloaded: 4895 time (s)

andros 18-09-2008 7:11


Reindee
r herder prof75, Boys can not be removed, but the field assembly - is necessary.

Posts:
18438

prof75 18-09-2008 7:32


San
Sanych andros wrote:
Posts:
Trances can not delete, but the field assembly - is necessary.
520
Completely

alex3 18-09-2008 8:33


Party
Posts: looked in the morning that I painted, true test will be if the zener leave for 10noge a
2086 divider through a diode to set a lower threshold for 9 noge.po datasheet it is 1.19v
LARTE 18-09-2008 8:35
R
Mozgop 9 foot he looks at the state of the lamps during ignition and combustion, and manages
rav the keys on this, as of course it is connected with a protection, but acting on the 9 foot
can affect the performance of all of the inverter.
Posts:
3477

Rottor 18-09-2008 9:05


Guest
89,138. alex3,
*. * Will not work on 10 conclusion.
1 Zener voltage with this stabistorov, which has relatively low reverse resistance.
2 -Stabilitron (stabistorov) does not work in micro.
Input impedance for the withdrawal of 10 - megger. Connecting Microcurrent
stabistorov violates the operation of the chip.
3 - In the protection scheme involves several such pins 1, 2, 4, 9, 10.

LARTER, irrepressible desire popizdet?


Finish lengthen topic empty slogans and grandiose "projects."
Do, or show the scheme as implemented in your version.
Or do not bother.
victoria 18-09-2008 18:10
n
Party Rottor wrote:
Posts:
You do not have information on ways to incorporate chip (s) in order to
972
disable the protection and transfer it in the "manual" mode is controlled?

Rottor, off protection easily lock timer capacitor .Konkretno probyval for OZ9938.V
OZ960 see a similar foot-1 CTIMR.Etot capacitor starts charging to trigger sensors
and on time by the charges of protection zablokirovany.Shunt kiloomnikom capacitor
permanently stop protection
Rottor 18-09-2008 20:40
Guest
87.69. *. victorian,
* Indistinctly.
Whether a turnkey solution, or offer "method" for implementation.
I was unable to solve the problem this way.
If you have more specific information you specify.
- Connect the output circuit 1 through 5 to 1k or "ground" is not blocking protection.
Pin 1 is the type of "Reset" to include, to enter the chip in operation.
Protection throughout the range PWM checked against the saw formed capacitor at
pin 4 "soft start".
At the moment when the work circuit (glow lamp) in emergency mode is determined
by the capacitor on pin 4.
- The capacitor on pin 4 defines what is described as "The lamps are lit for a few
seconds and go out."
The capacitor on pin 1 to blocking protection does not apply.
Strike 18-09-2008 21:17
idiot
Posts: Rottor, could not, would lay the waveform (from 1 scheme) 45,46,47?
2177
Posted 18-09-2008 23:30

I can assume that you can use the "saw" output from the chip and make it to the
protection scheme.
Thus, the PWM will not "see" the output stage.
Rottor 18-09-2008 21:47
Guest
87.69. *. Strike,
* I'm sorry but I have no such devices to be repaired, and the scheme I have
downloaded from the internet.
I have a workshop area and LCD comes a couple of times a month at best.
With regard to the repair of inverters "ostsiloskopirovaniem" is empty, then I figured
out the pros - pizdobolami owning such sophisticated techniques.
http://monitor.net.ru/forum/viewtopic.php?t=151397

I'm not an expert on LCD but I can really help with the repair procedure and
instructions about how to disable protection.

Strike wrote:
I can assume that you can use the "saw" output from the chip and make it to
the protection scheme.

The assumption is true, because it is the only and the easiest way to solve the external
pins.
The only question is in the process of implementation.
Strike 18-09-2008 22:22
idiot
Posts: Some chips have a test mode, as understood it is necessary to drive them to
2177 "Generotora"
While there are no developments, on occasion try.
Rottor 18-09-2008 23:08
Guest
87.69. *. Strike,
* I was hoping for a discussion of this topic but it seems that the "repair" LCL is the
swan song as the last stage in the rank of specialist - in this profession a TV technician
ends.
All smoothly into the name of the board, Part Number, trade eblom or components
depending on the degree of access.

- Protection trips this way:


To withdraw 4 chips (soft start) on the outside of the container is formed by a saw
which provides management (inclusion) PWM from 1.2 to 3,5 V to verify the mode of
feedback to protect.
If you provide on output voltage level to a specified "window" is not being blocked
provide PWM output from minimum to maximum.
Above and below the "window" a bulb happens PWM is disabled and goes to trigger
protection which is reset pin 1.
Complexity of implementation is that the capacitance is charged by a current source
One unit microamps.
Application divisors violates the chip.

I applied voltage limiter key to fix the potential of the capacitor which is charged by a
current source in the chip.
As adjustable voltage regulator is used reverse-(locked) and the diode voltage source
5V.
Ie drinking freely formed but a certain threshold, which determines the PWM constant
power and brightness of the lamps, respectively, while maintaining a smooth start.

The addition of two parts allows you to block the installation of protection circuits
constant brightness level adjustable potentiometer.
This can be used as a temporary technological device repair inverters to force start to
identify the causes of faults using a chip.
Rottor 19-09-2008 8:59
Guest
89,138. gavrykgsm wrote:
*. *
For defektovaniya and identify faults in the inverter to OZ960 there is much
more acceptable and less effective ways to ...

Describe, for example, one of the methods.


gavrykg 19-09-2008 11:11
sm
Guest Rottor wrote:
84,204.
Describe, for example, one of the methods.
*. *
Duc describe something you can only STE unlikely someone like ......
The meaning of the following:
2nd leg -can do not consider that it is in the "air" that the "body" planted - stupid ... no
effect ... therefore protected by OVP can be ignored ....
The 10th leg .... raises many questions, for 3 days lay out the dynamics of processes
on this leg ..... IMHO, this is something with which to work ....
9th leg - complete dependence (logarithmic) capacity of the 10th leg, also taken in the
"development" ....
Plus, until the pile, 8th and 1st leg .... With these little unclear .....
Exemplary methods defektovaniya I've described here,
http://monitor.net.ru/forum/viewtopic.php?t=238636 apply to all inverters, without
exception ....
victoria 19-09-2008 11:27
n
Party Quote:
Posts:
victorian,
972
Indistinctly.
Whether a turnkey solution, or offer "method" for implementation.
I was unable to solve the problem this way.
If you have more specific information you specify.

Rottor, clarify, worked with OZ9938, normally locked, I lied about kiloomnika
memory nor chёrtu.Shuntiroval likely 100 kilohms, as came to this possibility probe
ostsila. Leg 1-CTIMR-rezet not, I have translated as blocking protection time
(charge CTIMR), necessary for reliable ignition with a range of lamp types (length,
diameter of the lamp, the current temperature) .Po flowchart OZ960 see the
connection between CCFL and software start-so low impedance shunt may simply
puts start.Po dispute about the necessity and convenience of blocking protection
during Troubleshooting-absolutely necessary.
Rottor 19-09-2008 12:37
Guest
89,138. gavrykgsm wrote:
*. *
... Describe something you can only STE unlikely someone will like

victorian wrote:
Shunted likely 100 kilohms, as came to this possibility

The technique is simple a complete description of meaningful action solves the


problem that is designated as "Unprotect inverter?"

In your post there is only a protocol of intent - which does not allow vospolzovatsya
information you provide to accomplish the task.
It only spreads the topic making it long and unreadable.
If there is no specific information, then do not replace it and smearing projests
semolina on a plate.

victorian wrote:
Leg 1-CTIMR-rezet not, I have translated as lock protection
How remark accept BUT:
- No error.
About the "Pin 1 is the type of" Reset "I initially written in quotation marks.
This time delay is relevant to the protection (timing), it starts with a "zero" that is,
with a power-on reset - it means nothing more than a "Reset" by the process.
- This does not conflict in the context of my discussion of the interpretation of the
idea of blocking.
According to the spelling intended output does not match the chip only Pdf.
victoria 19-09-2008 13:39
n
Party Rottor wrote:
Posts:
The technique is simple a complete description of meaningful action solves
972
the problem that is designated as "Unprotect inverter?"

I just shared his own experience, without pretending to "technique", that's for you to
choose the right way, otherwise
Rottor wrote:
semolina on a plate.

Rottor wrote:
About the "Pin 1 is the type of" Reset "I initially written in quotation marks.
This time delay is relevant to the protection (timing), it starts with a "zero"
that is, with a power-on reset - it means nothing more than a "Reset" in a
manner

In the particular case of transients when the yes, generally "zero" starts with
emergency information from the sensors and during raboty.Formiruetsya delay from:
sensor-off charge drayva.Blokiruya known capacitor stretch on time to protect
beskonechnosti.Chto uncomprehended I suggested?
Strike 19-09-2008 20:26
idiot
Posts: And do not try?
2177 R8 - from datasheet.
SV 20-09-2008 17:46
Party
Posts: Rottor, Buy AshErovsky probe for lamps and half of the problem will be solved. His
623 name TL1040

Rottor 20-09-2008 18:54


Guest
87.69. *. SV wrote:
*
Buy AshErovsky probe for lamps and half of the problem will be solved.
You mean this: http://www.classic-music.ru/images/buben.jpg
Here I have already spoken on this issue: http://monitor.net.ru/forum/viewtopic.php?
t=233533
I do not understand what does "AshErovsky probe" has to shut down to protect the
inverter on a chip?

Penultimate wise idea about "classic Chimay" was nedovyskazana thee here:
http://monitor.net.ru/forum/viewtopic.php?p=1637700#1637700
In this topic you decided to pay his part in what capacity?
SV 21-09-2008 5:00
Party
Posts: Rottor wrote:
623
You mean this: http://www.classic-music.ru/images/buben.jpg

No this is: http://www.kimkit.ru/index.php?id_kat=1000&id_tov=64677


In practice reveals not only the faulty bulbs, but also coiled circuit vtorichek trance.
Rottor wrote:
Penultimate wise idea about "classic Chimay" was nedovyskazana thee here:
http://monitor.net.ru/forum/viewtopic.php?p=1637700#1637700
In this topic you decided to pay his part in what capacity?

Alexander, well, what are your ambitions ?! I do not ditch your ass on the role of the
pros theorist, I have enough of a modest share of the practice. What I was wrong in
the subject to which you refer ?! That there had to be dovyskazat? Share Marozik
from scratch principles of SMPS?
On this subject: I see no reason roughened protection. Faulty section is defined in 15
seconds. If you wish, you can unsolder the diodes and see where the smoke goes, but
it's easier to check and replace the faulty piece of metal
Rottor 21-09-2008 7:11
Guest
87.69. *. SV wrote:
*
- On this topic: I see no reason roughened protection. - Faulty section is
defined in 15 seconds.

- It's your business, but nothing to do with this topic it has not.
- About the pros and "15 Seconds norms" for the repair of inverters, I heard on that
forum.

- If you post in the topic it should be informative, or have a sense of approximation to


the solution to the question raised - as well as one pizdobolstvo with sketches from
nature ...

In principle, all on - wait for Monday.


Shafts 21-09-2008 13:09
Jura
Party You can have a multi-inverter works fine.
Posts: When you delete a trance, send a signal to the sensor on a non-working. See Fig., The
593 resistor can be removed.
Rottor 21-09-2008 13:11
Guest
89,138. Shafts Jura
*. * It is checked?

Shafts 21-09-2008 13:14


Jura
Party Tested, inverters Philips 8 trance.
Posts:
593

Rottor 21-09-2008 14:17


Guest
89,138. Shafts Jura
*. * Under the scheme is not very clear way (duplication diodes), still all connected to
common one channel after the diodes.
- In the proposed variant is not disabling protection.
Protection, and brightness control operates normally.
Shafts 21-09-2008 14:40
Jura
Party Rottor wrote:
Posts:
- In the proposed variant is not disabling protection.
593
Protection, and brightness control operates normally.

This circumvention of protection that disable and not desirable in the case of other
faults.
What does the easiest, though conducted experiments to unmount Polevikov and
diode arrays, also helped.
Rottor 21-09-2008 20:57
Guest
87.69. *. Shafts Jura wrote:
*
This bypass protection ...
What does the easiest, though conducted experiments

I quite tactfully hinted at doubts about the wisdom of your "options", and you finally
razchirikalsya in his own confidence ...

In general, as follows:
For lamer as possible and ride at the level of confidence in your post.
However, the amplitudes at the points A and B are summed at point C.
This means that you TRANDISH.
This scheme works only on exceeding a threshold amplitude of the output voltage of
the transformer which is controlled by the growth of the bus voltage protection at the
point C.
This happens only when the (fault) lamps, or PWM output in "dressing".
VTS control scheme does not determine the amplitude and does not protect.

- That is, when you remove the transformer (at your option) do not need to make any
changes, jumpers, and beats the drum ...

- While waiting - Monday will be asked to radical solution to bypass the protection.
Shafts 21-09-2008 23:44
Jura
Party Rottor, understand that we are talking about different things.
Posts: No inverter circuits Philips (in nature), so that the example shown on your circuit.
593 Scheme there is much more fancy, so just connect the points A, B and C can not.
There when watering trance protection trips, which we bypassed by applying a signal
from the sensor working on the sensor with no trans.
Here the idea is important, and not binding to a particular scheme. Especially
not write that it is a panacea for everything.
Rottor 22-09-2008 8:57
Guest
89,138. You're not the first one.
*. * First, "all turned off clear and simple"
Then specifies certain "conditions" and calls for reflection, after which it becomes
Nichrome unclear and is not even clear what it was?
Shafts Jura wrote:
Here the idea is important, and not binding to a particular scheme.

There is "important" specific circuit solution allows to implement it in reality.


Good intentions and "thought" here napizdobolili already three pages.

If there is no specific, proven solutions that better then not to participate with
oboobschayuschimi projests.
Profess 31-10-2008 20:19
or
Nimnul In Elenbergah did: killed trans (determined masterkitom, and even visually) threw,
Warnin threw a lamp connected to it. Zaparallelival folded lamp socket with neighboring
gs: 1 (conclusions of the same name), and so betrayed. Without one lamp works no worse
than with vsemi.Uvy passes only simple inverters. Toshiba, for example, so fool not
Posts: work
127

mag58 29-01-2009 19:17


Noob
Posts: 5 I made and its contribution to the debate))

Rottor Special thanks to you, as well as all participants in the discussion.


defect:
- To monitor LG flatron L1515S when the backlight flashed for a moment and went
out,

measured the voltage,


all modes of output power supply and on the legs like a normal chip
connect new lamp -effect same ,. this realized that the lamp at anything.
Was the search for a way ,, decided to try to block protection from chips OZ960D,
pre-reading this topic.
read articles, take note of all the arguments, and soldered silicon diodik
(Took the first arm was caught with imported glass boards) anode to the 4th leg (as
Rottor recommended, and the cathode to the 7th leg of the chip OZ960D)

Monitor starts, earned lights and turn off most.


Rottor 03-02-2009 9:59
Guest
89,138. mag58 wrote:
*. *
- I made and its contribution to the debate))
- Monitor starts, earned lights and turn off most.

This proposal has a nominal value of mites.


For a description of the method specify:
Rottor wrote:
The addition of two parts allows you to block the installation of protection
circuits constant brightness level adjustable potentiometer.

What does it mean:


- Randomly assigned to sub-optimal brightness leads to excess current consumption
and overload clutches and inverter.
Hence the conclusion - saving potentiometer = rapid component failure due to
overload.

PS
For those who do not understand.
- Blocking protection disables the nominal brightness control by PWM.
- Potentiometer sets the required (constant) brightness value in the minimum values of
the current consumed by the inverter.
- As required adjustment (potentiometer) can be compensated by reducing the
intensity of the glow lamps.
mag58 03-02-2009 16:04
Noob
Posts: 5 How many volts corresponds to a non-optimal brightness?

you have written in the range of 1.2 - 3.5V upper position of the potentiometer
corresponds to your circuit 5c

As proposed, me, scheme (using a single diode) the maximum voltage at the cathode
of the diode corresponds to 2.5
This is sub-optimal brightness mode? ...))))

PS
I did not set myself for such tasks polysyllabic ,, brightness mode resulting from such
"modernization" and gave me quite the same client ..
Well, you and the cards in your hand, it is possible to figure out what is more perfect
in the schematic and share the results with us.
KRAB 21-04-2009 1:17
monitor
.net.ru Removing protection for BIT3193:
When the protection is activated the voltage at terminal 5 of about 3, 5 V.
Posts: When the voltage on pin 5, from 0.4 to 2.4V, and the command "start" PWM operates
14071 autonomously, the lamp does not turn off.
Option - 1
Through a resistor 2 - 3 com pin 5 is connected to terminal 12 chips thus keep
"working" potential of about 1.2 V.
Option - 2
LED as stabistorov connected to pin 5 to ground-Live, "stabilizes" the voltage at
terminal 5 to 06 - 08 volts.

Unprotect TL1451:
- Blocking protection chip TL1451 (analogue VA9741) is reduced to a simple action-
circuiting the terminals 15 on the "ground".
But if you do it after a trip (eg forceps), then nothing happens because the trigger
protection is already locked by feedback sensors.
- To restore the performance you need to reset the trigger protection switching off and
on the inverter or a change in the level on pin 9 of the chip.
In operating mode, the monitor reset trigger protection is automatically updated.

In this procedure, troubleshooting and repair of the inverter is reduced to a


simple shutdown protection that allows us to solve most of the problems for 5 -
10 minutes, without any additional equipment and components.

udaw 14-05-2009 12:08


Party
Posts: Shafts Jura wrote: When you delete a trance, send a signal to the sensor on a non-
185 working. See Fig., The resistor can be removed.

Can not, as needed. Jura, the idea is correct. But you do not specify a very important
fact. Signal from
"Working" sensor to not "working" to be transmitted
no drawdown on this ill-fated resistor.
For other circuit solutions is paramount.
Vladimi 14-05-2009 14:29
r1234
Banned And what if all the sensors and so joined together? There is a TV Techno TS-LCD-
3225, there should LX1692. Is it possible to somehow cheat? Found that cheat
Posts: protection can be disabled 14 foot chip on the circuit ... This datasheet:
405

LX1692.pdf 271.34 KB Downloaded: 3405 time (s)

udaw 19-05-2009 12:19


Party
Posts: Vladimir1234, this method is appropriate for expensive, mnogotransformatornyh,
185 mnogolampovyh inverters used in large LCD TVs.
Since it is impossible to replace the burned-out
transformer, in agreement with the owner,
derived from the work of the defective channel. Protection circuit
connected to the adjacent working sensor. Brightness
regulated, no cost, the only drawback to the bright-plots at the site is not on Lights-
horizontal shading. By the way, not all owners noticed it immediately.

PS. If you are connected to a single transformer two


lamps, they can be reconnected, to lengthen the connection conductors of adjacent
tubes and thereby to spread up and down.

PS2. Modern LCD TVs out of


failure of one of the transformers is not blocking
operation of all of the inverter (if this has not led to a short-circuit
chains for the total power, in this case
shorts are removed).
KRAB 14-08-2009 22:21
monitor
.net.ru Removing protection for OZ964:

Posts: ( http://pdf1.alldatasheet.com/datasheet-pdf/view/226913/ETC/OZ964.html )
14071
On pin 4 (SST - Soft-Start Time) at the moment when you need to keep the 1,8 - 2V.
Connect as stabistorov red LED, apply voltage across the resistor 5.1 ohms from the
source 8 - 12V.
The chain of resistors and LEDs connected to the IC PWM constant.

KRAB 19-08-2009 1:56


monitor
.net.ru Packard Bell Callisto 170-700P - lock inverter TL494

Posts: Entered Monitor Packard Bell Callisto 170-700P (on the metal casing has a sticker
14071 Samsung-171) - according to the search, he is close to Xerox XA7-17i 700P and
Fujitsu-Siemens 700P.

An autopsy showed that the Lamp, "glass" and "plowed" UPS + inverter board (worth
"bug» (F2 - 3,15 A) circuit power inverter + 14V, payany inverter transistors labeled
3055). Inverter combined with UPS - PCB marking MIRAGE ELECTRONIKS AD-
1700 REV: F. (photo borrowed on the forum). IMS Inverter - TL494 (TEXAS
INSTRUMENT) in a planar design, analogs IR3M02 (SHARP), iA494
(FAIRCHILD), KA7500 (SAMSUNG), MV3759 (FUJITSU), KR1114EU4 (CIS).
Restoring and UPS connection - appears when you turn on the backlight, the picture
and after a few seconds strong heating transistors and burnout "bugs" because of the
large current.
With the help of an external inverter from the TV were immediately were checked all
4 lamps. Transistors 3055 (not vypaivaya) Call faulty.
Autonomous power inverter (backlight) is operated by the withdrawal of BL ON
connector logical "1" (with the + 5V power supply through a resistor 1k).

For rapid diagnosis Framed KT819, KT829A then - the situation has not changed -
overheating, high current consumption. Just specify that misled found in search (by
line monitor and labeling of transistor inverter) theme http://monitor.net.ru/forum/nec-
17-lh17m-ncl-1716-ph-b0-info-184746. HT ... (description of the defect 1: 1) because
it was not the wrong type transistors mje3055 (bipolar npn). Here is the snippet:

Tarkus wrote:
I write in this topic, because the problem with the exact same board, but not
in the power supply and the inverter. Monitor Packard Bell Callisto 190
(model 900P).
Inverter TL494, with a bunch of discrete binding. Attempts to find a scheme
failed, I will draw.
2 burned transistor key mje3055 and fuse on power inverter 3A, replaced;
keys very heated, worked for 5-7 seconds, and then the fuse blows. I
powered inverter undervoltage current limit, I see that after the TL494
voltage sags heavily on reservoirs key ring, on the outputs of 494 small ugly
impulses (power m / c falls to 5-6V).
Question as to whether the case in the transformer (s)? Inductance coils took
it, both trans and the same non-zero. Maybe someone has such a scheme?

When viewing oscilloscope databases transistors keys - "garbage". Sealed-off


transistors - naturally inverter went into protection mode - trigger pulses with TL494
not.

For his "lock" sufficient additional solder resistor 10k between disabled (in
practice - and you can not disable) 2 terminal (inverting input of the error
amplifier) IC TL494 and connected together pin 13 (mode) and 14 (reference DC
voltage of + 5V ) - see Fig..

In the circuit of the inverter output TL494 is included in the circuit with common
collector - external load connected to the emitter of the transistor (pins 9 and 10) and
the output pulses, "sent" in this case, emissions up (rising edge of the positive) - see
Fig. IC and description. After that, when you start off the inverter were removed
ostsillogramy - at pin 5 sawtooth voltage amplitude about 3V, at the terminals 9, 10 -
square wave amplitude 11V, on the "B" output keys - similar impulses. Immediately
there was a question about the "correctness of determining the type of transistor keys"
and "title" conclusions transistors GDS.

Further searches led to the transistors P3055LDG (N-channel Logic Level


Enhancement Mode Field Effect Transistor) company NIKOS. (Analogues - tm3055;
AOD444; 2SK3055; F3055L, (P3055), PHD3055E - apply to many of the "parent"
boards).
Instead P3055LDG (Vdcc = 25V; Rds = 0,05 Ohm, Id = (8-12) A; Pd = (20-48) W;
housing TO-252 (DPAK)) were immediately installed transistors IRF630 (Vdcc =
200V ; Rds = 0,4 Ohm, Id = 9A; Pd = 74W; housing TO-220), despite the fact that
they are not "controlled Polevik logic levels", but which always monitors a
disassembly sufficient. Heating transistors does not exceed 40-45 degrees. The forum
is information that can be replaced and IRFZ44 («makeshift" but P3055LDG in the
free market - not just in the price lists).

The efficiency of each transformer was quickly checked in turn connected to the
inverter board (with a blocked protection) its primary winding remote mounting. On
the secondary side is simply connected lamp that has long been used to verify that the
inverters TFT TV (see. Photo).

For reference: the resistance of the secondary windings of transformers inverter about
360 ohms when checking "Tester fault-turns" (Master-KIT) primaries - all LEDs,
secondary - only 2-3 (mistakenly diagnoses), but a shorted secondary and primary
testing - immediately shows the presence of faults.

After the restoration of installation and protection release - monitor works OK.

For information:
1. Details of the TL494 IC can be read here: http://qrx.narod.ru/book/at/ ,
http://gauss2k.narod.ru/jab/ims02.htm .
2. If repair is necessary to "finalize" PP + UPS inverter - break ferrite tube, put on the
wire that connects the "earth" UPS "ground" of the inverter:
http://www.monitorlab.ru/forum/viewtopic.php?t = 13513 & Highlight = ad1 ... ("Do
not believe the ferrite on the wire dressed !!!"),
http://monitor.espec.ws/section3/topic85665.html - otherwise possible loss of the
backlight is switched on.
3. To reduce the ripple in the power circuit of the inverter + 14V additionally installed
capacitor 2200.0 uF.
4. Without signal (PC connection) after turning on the monitor is included in the PP,
the message "No Signal" on and off (the indicator changes color from blue to glow
yellow, lights turned off).
5. Topics with mention of the PP + UPS inverter transistors keys, etc.
http://monitor.net.ru/forum/monitors-mag-lt716s-2-info-227783.html
http://monitor.net.ru/forum/tft-proview-700p-ma782k-info-181428.html
http://monitor.net.ru/forum/viewtopic.php?t=293391
http://monitor.net.ru/forum/lcd-tv-premiera-rtr-750zx-info-180261.html
flach 10-10-2009 7:13
Party
Posts: KRAB, thank you tried the method described, the removal of protection for OZ964,
43 happened only want to add that the faulty transformer had to be removed at all,
otherwise the-counter does not work

kurtsvl 16-12-2009 17:59


Noob
Posts: 7 Monitor SAMSUNG Syncmaster 215TW

Inverter 6 lamps with 6 transformers


BN44-00127B
assembled on MP1038EY

burned one of the transformers


Valenti 16-01-2010 11:35
n
Warnin Very long lay BN44-00182C module with living the transformer in the inverter, has
gs: 1 decided to throw in the well-known trance ... 123rd block, a primary trans paralleled,
and 1yu FAN7314 set foot on the 4.3v zener with + 5V and 620 ohm resistor on the
Posts: body.
385

Nlfjk 28-01-2010 13:19


Guest
85.64. *. To disable the on-chip OZ99361.
*
- Method similar to that described in this topic in the message from 18-09-2008 23:08
Adjustable divider voltage regulator is assembled on two resistors:
- The top 10k resistor to + 5V.
- From the common wire connected potentiometer 22 com.
Diode any silicon.
- After assembling the circuit regulator to set the voltage at terminal 1 of the chip
within the sustainable launch 1,85 - 1,98V
On this unit is set 1,90V.

- Mounting option for photos.

OZ99361.rar 195.91 KB Downloaded: 4444 time (s)

gusek 21-02-2010 13:43


Party
Posts: Prompt how to remove protection from OZ964?
1754 On the advice of KRAB, with LED 4 foot nothing happened.
Tried as it is written here:
http://monitor.net.ru/forum/oz960-info-96219.html
penultimate message, but also did not work.
andros 21-02-2010 16:15
Reindee
r herder gusek, voiced the troubles and the reason oklyucheniem protection. After some time
disappears lights. There is something which operating time. By the way - and the
name of the matrix with a photo of the inverter is not meshalob.
Posts:
18438

gusek 21-02-2010 16:23


Party
Posts: andros, want to check the reason for a chip or something drugom.Podsvetka does not
1754 appear.
The inverter is built into the dashboard radio.
Here this topic:
http://monitor.net.ru/forum/viewtopic.php?t=309922
andros 21-02-2010 16:39
Reindee
r herder gusek, Duc in your case, fault or lamp, or trance, with periodic vitkachёm. And under
napruga. Here you disable security will not help.

Posted 21/02/2010 22:41


Posts:
18438 IMHO nothing to do with the driver. Periodicals - is higher factors or snot interlayer.

Posted 21/02/2010 22:42

gusek, By the way, can and clay obvyazke. SchA try to find a topic.
gusek 21-02-2010 16:53
Party
Posts: andros, lamp tested on another inverter - is working properly.
1754 Yes, and I tossed the other transformer, though a bit not the same as home, but still
think it should have been run, but will not start.

andros 21-02-2010 17:10


Reindee
r herder gusek, Here http://monitor.net.ru/forum/viewtopic.php?p=1710423#1658647 , a little
something, but the meaning is clear. Stepped on a rake these - namely, periodicals his
mother! And all because of fucking "clay" air-conditioner!
Posts:
18438

ir0407 22-02-2010 2:42


Party
Posts: In addition to the post KRAB yet spread shemku inverter just found very close to the
189 inverter circuit, which he painted.

Sam is now mudohayus one such. It is not yet won. The problem is that all
rabotaet.Esli turn on the cold can work out an hour or two and then goes out, and
maybe 15-20 minutes go out. With the heating of the work is reduced. Lamps tested
on another monitor, electrolytes polls all replaced, ferrite on peremyke weight lifted.
Diode Arrays at 5 and 14 volts replaced just in case. Please highlight force. Drove.
Found that after a while the output 14B appears shit and slightly squander voltage (up
to 13V). Thus from TPI itching with slightly varying tone. Lamp while continuing to
burn properly, nothing is overheating protection does not work. In general while in the
process ... the result will accomplish your goal.

Posted 22-02-2010 2:06

Here's something for the backlight inverter circuitry from the Chinese.

Posted 07/05/2010 00:46


Saga ended with this monitor. Due to the fact that the defect manifests itself
through a very long and regular intervals, and might not appear at all in a few days it
was difficult to locate. Monitor back to me 4 times. Eventually the 5th time I did
vyschemil defect. The culprits were SMD- capacitors trim TL431.

PI-PI-170DTLA 190DTLB 200-000-170TLBMH MIRAGE


ELECTRONICS.part1.rar 488.28 KB Downloaded: 4911 time (s)
PI-PI-170DTLA 190DTLB 200-000-170TLBMH MIRAGE
ELECTRONICS.part2.rar 72.87 KB Downloaded: 3450 time (s)
CCFLINVERTER.part1.rar 488.28 KB Downloaded: 3905 time (s)
CCFLINVERTER.part2.rar 384.75 KB Downloaded: 4634 time (s)
dudal 27-02-2010 14:12
Warnin
gs: 1 Entered the repair LCD Monitor Samsung 192V. After turning on the light after a few
seconds the backlight and then go out. BP and the inverter BN44-00088A collected on
Posts: a single board. The inverter has four transformers and four lamps. By alternately
39 connecting two known good lamps found that there is no high voltage in one of the
transformers. Turned out to be an open high-voltage winding. Restore winding failed.
After studying the topic "Inverter BN44-00082A - disable protection"
http://monitor.net.ru/forum/bn44-00082a-info-311096.html, proceed as follows -
closed the drain-source in Q2.
In the aforementioned topic author TL4M removed from the circuit transformer and
disabled two lamps. I decided that in my case the transformer can not be removed,
because the primary windings of two adjacent transformers intact and connected in
series - is it possible to leave the monitor working in three lamps. Drain-source
transistors Q2, Q3 connected in series and serve the same role as that of Q4, Q5 in
http://monitor.net.ru/forum/bn44-00082a-info-311096.html, used only in the other
arm.
After repair the monitor works fine.
dzgaga 26-06-2010 22:24
Party
Posts: confirm the word victorian, 1000 ohm resistor in parallel konedensatoru off
42 protection

udaw 01-07-2010 19:39


Party
Posts: PWM inverter STR-H2003 (datasheet-a - NO)
185 Panasonic TX20LA60P ch. SL-131PP
PWM MP STR-W6856.
Lamps 6, 6 transformers.

Lights lit, and after 1-3 seconds. blinking goes off.


BB winding transformers with one end grounded,
loaded on a second lamp and parallel to the capacitive divider,
that is, the sensor napryazheniya.Podklyuchivshis ostsem
the midpoint of the connection of capacitors, define the transformer
with flickering Winding short-circuit
Defective transformer desoldering.
Without transformer inverter works steadily,
the absence of one of the six lamps is not noticeable.

Determine the defect in a trance or in a lamp, if


lamps toss not, you can on the testimony ostsa
with the voltage sensor.
T. k. In this scheme, the lamp is connected without ballastera,
with short-circuit the supply of "hot" wire to the lamp housing,
voltage at a connection point of the sensor capacitors to near zero.
When interturn KZ flickering in the transformer,
due to a significant stray field, the voltage
the sensor will not fall to zero, and will take
different values, no more working in synchronization with the flashing emergency
lamp before tripping Shima.
At breakage of the lead wire lamp or her aging
depressurization, the voltage to the sensor will
Overvalued compared to neighboring channels.

In the diagnosis of this inverter is recommended


use waveforms of the voltage sensor and the current sensor does not,
t. k. a current sensor shows the same
at various breakdowns such as
1. Flashing to. H. Coiled in trensf ..
2. Shimmering break in the electrical system of the lamp.

MP and invertor2.jpg 76.91 KB Downloaded: 2103 time (s)


MP and inverter 1.jpg 55.3 KB Downloaded: 1754 time (s)

andros 02-07-2010 2:11


Reindee
r herder udaw, Where the name of a matrix? This model is equipped with several types of
mattresses .a secondly - trance on this panel are caught without a donkey, stupid
tester. And your defect can cause not trance, and the lamp .tak that your whole infa -
Posts: as dead a poultice. Better go to the flame flood, you better get it!
18438

KRAB 13-07-2010 22:09


monitor
.net.ru Inverter for 4 lamps TL494. - Installed in the 22 '' TV Samsung (China), etc.

Posts: Or immediately after the lights will flicker and disappear (logo visible) or can work
14071 for 5-10 minutes and switch off, spontaneous trip and simply non-functional
backlight.
Lamps are OK (new - predtorgah, checked), the inverter photo - below. Apparently it
is not designed for this power of lamps: overheating of transformers during normal
operation in the healthy new TV more than 65-70 degrees. With sealed transformer
(defective, but the secondary resistance is 1: 1 with intact - just trying to live) - the
inverter will not start.

To lock protection enough solder resistor 1 MOhm with 12 Volt (power inverter)
15 concluded TL494.

After that can be installed as other non-original transformer (see. Photo - left, set to
test), and his failure to use and easy to connect only 2 backlights (the image has
virtually no effect - from the words of the wholesaler - he did not notice).
DK 25-07-2010 20:52
Warnin
gs: 1 Valentin wrote:
a well-known ... 123rd block on 1yu FAN7314 set foot on the 4.3v zener
Posts:
with + 5V and 620 ohm resistor on the body.
198

and inverter BN44-000123E Model: SIP-U5F (M) with a defective trance The
Samsung 940N.
Troubleshooting for the secondary blocked FAN7314 protection even easier,
gave her the first leg of 1.5 volts AA batteries with two wires
maxxpr 03-09-2010 22:53
off
Noob DK wrote:
Posts: 5
Valentin wrote:
a well-known ... 123rd block on 1yu FAN7314 set foot on the 4.3v
zener with + 5V and 620 ohm resistor on the body.

and inverter BN44-000123E Model: SIP-U5F (M) with a defective trance


The Samsung 940N.
Troubleshooting for the secondary blocked FAN7314 protection even easier,

gave her the first leg of 1.5 volts AA batteries with two wires

Even easier to solder to the 1st leg of the LED-Live to the ground.
It will operate in stabistorov.
This method is described respected KRAB on the 2nd page of this topic, see the
removal of protection for BIT3193
Personally tested this method on the above inverter BN44-000123E Model: SIP-U5F
(M) with a broken vtorichkoy- protection does not work
NASER 16-10-2010 18:27
AT
Guest SKI across multiple PWM DT8211. Protection bypass resistor decrease by 8 foot.
92.46. *. Instead of 200 ohms set 10-20 ohms.
*

KRAB 12-11-2010 23:42


monitor
.net.ru Inverter for 4 lamps TL494. - Installed in the 23 '' TV Samsung (China), etc.

Posts: Predtorgah. When you turn on the backlight or not, or wink on and off. Lamps are
14071 OK.
Disabling protection similar to: http://monitor.net.ru/forum/viewtopic.php?
t=239071&start=64#256061 ...

To lock protection enough solder resistor 1 MOhm with 12 Volt (power inverter)
15 concluded TL494.

start a normal, audible perriodicheskoe "BB - stitching" in one of the transformers. In


principle, it can be safely ruled out, leaving 2 of 4 lamps - enough brightness to spare.
AMIT 09-12-2010 20:59
Party
Posts: 0Z960
214 very easy way to remove the protection.
supply LED C10 feet on the ground. (6 foot chip)

Vlad007 29-12-2010 15:30


taster
Posts: AMIT wrote:
2050
0Z960
a very simple way ...

working
AMIT wrote:
... Put LED ...

prametrom close to 20 mA
ra4llb 13-01-2011 9:35
Warnin
gs: 1 oz960 --- kiloomnikom not blocked, but the battery to 1.5V through a resistor 10th
plus the housing easily (the battery is connected to the first leg)
Posts:
239

kermen 15-01-2011 10:08


chik
Noob KRAB way with a red LED (falling 1.5 volts) and vypayanymi keys idle channel
Posts: protection OZ960 shot easily.
10

Vlad007 15-01-2011 11:02


taster
Posts: kermenchik wrote:
2050
KRAB way with a red LED (falling 1.5 volts) and vypayanymi keys idle
channel protection OZ960 shot easily.

AMIT wrote:
0Z960
very easy way to remove the protection.
supply LED C10 feet on the ground. (6 foot chip)
mladshi 17-01-2011 18:39
Party
Posts: AMIT, That'S Perfect !!!
572
"0Z960
very easy way to remove the protection.
supply LED C10 feet on the ground. (6 foot chip) "

perfect solution, it is worth 20 "Samsung (matrix AUO) other 4-5 years ago, when the
go out after a few seconds, the inverter 6 lamps
If you turn once working days. (Blame lamps all at once, to understand posmotrel- all
equally with the lights worked Hilo manage resource, tossed 20 "AUO wide by Sonke
- everything is OK)

connected svetodiod- glow when on the move to disable one of the lamps is turned
off, and if one of the bulbs that will not turn off that gud, the main defect is gone,
pomotrite how long stretch.
artur58 09-02-2011 16:37
Party
Posts: Erisson 26LS16, THOMSON 26N90NH10 power unit MIP260
114 Combined power supply and inverter. Composition: L6562 - preconditioner,
SG3525AN and board submodule F9222 - Inverter

Preconditioner for Q101 and driver L6562D.


BP dir duty on discrete elements, the key Q104.
Half-bridge inverter Q103 Q102 T101 C104 C105 - generates voltage slave. mode,
while the variable component is fed to the inverter transformers. Signals for the
inverter formiruyutsya in inverter circuit. Activated inverter protection. Usually, the
problem of making MCU UPD78F9222.
To drown her jumper (.) And 19 (.) 20 connector CON1 - board MCU UPD78F9222.
KRAB 30-03-2011 1:21
monitor
.net.ru http://www.o2micro.com/prods/o2m_int_ltg_brochure.pdf

Posts:
14071
X1-42 13-04-2011 16:56
Party
Posts: POLAR 38LTV4105 inverter and power supply on the same board - PLT-055. BP on
40 the TDA1506 + field.
Inverter chip UBA2071AT + two field STP60N06.
Forced into submission grounding pin 5 of the chip.
Forced the search for protection when the method of replacing the board found out
that she does not like the lamp.

Posted 13-04-2011 17:07

Thank you for AMIT decision OZ960.


Is there such a model - POLAR 51LTV2010. Turns off the backlight after 1.5-2 hours.
2 copies. When the LED 10 foot firmly resolved the problem.
KRAB 21-04-2011 22:47
monitor
.net.ru Samsung LE27T51B - inverter OZ960

Posts: 3rd top transformer - loss of one of the windings -


14071 AMIT wrote:
0Z960 - very easy way to remove protection - LED C10 put your feet on the
ground.
Winding resistance intact - 945 ohms.

Transformer installed and removed in accordance with the recommendations of the


LED. When viewed at an angle - a slight darkening in the area of the lamp is off.

laureve 30-07-2011 18:23


na
Party X1-42 wrote:
Posts:
POLAR 38LTV4105 inverter and power supply on the same board - PLT-
343
055. BP on the TDA1506 + field.
Inverter chip UBA2071AT + two field STP60N06.
Forced into submission grounding pin 5 of the chip.
Forced the search for protection when the method of replacing the board
found out that she does not like the lamp.

PHILIPS chassis TPM4.1e


PD with an inverter on a single board.
Inverter chip UBA2071AT + two field 8N60
5 Conclusion on the weight did not help.
But with 6 LED display on the weight of great help and telecom took the wrong lamp.
Piramid 30-07-2011 18:44
on
Party KRAB wrote:
Posts:
Transformer installed and removed in accordance with the recommendations
401
of the LED. .
A lamp brightness than regulated?
KRAB 31-07-2011 14:46
monitor
.net.ru Piramidon wrote:
lamp brightness than regulated?
Posts: - Honestly - not even checked DIMM from the menu (and would not dream of that
14071 blocked protection will not work adjustment) - it was urgent issue (customer said: if
only worked and quickly) Visually - just a standard (without the "whitish flare")
image.

Alex, and that - similar to the inverter in the work?

PS: for the interest rechecked just that, but in a different inverter FAN7314 to a
"locked" protection - all regulated without problems.
Piramid 31-07-2011 15:50
on
Party KRAB,
Posts: Ok!
401 Not everywhere can still adjust the brightness after the lockout protection, I do not
know how in your case BUT
- The fact that in addition to disabling the protection you need to seek the ability to
adjust the brightness of the lamps.
A simple crafts, proposed by some authors do not provide such an opportunity that
leads to increased brightness and rapid deterioration of lamps.

Therefore, I have at least once warned about it, but the findings seem nobody does.
Rottor wrote:
mag58 wrote:
- I made and its contribution to the debate))
- Monitor starts, earned lights and turn off most.

This proposal has a nominal value of mites.


For a description of the method specify:
Rottor wrote:
The addition of two parts allows you to block the installation of
protection circuits constant brightness level adjustable
potentiometer.

What does it mean:


- Randomly assigned to sub-optimal brightness leads to excess current
consumption and overload clutches and inverter.
Hence the conclusion - saving potentiometer = rapid component failure
due to overload.

PS
For those who do not understand.
- Blocking protection disables the nominal brightness control by PWM.
- Potentiometer sets the required (constant) brightness value in the minimum
values of the current consumed by the inverter.
- As required adjustment (potentiometer) can be compensated by reducing the intensity of
the glow lamps.

Ildar 10-09-2011 12:47


AMD
Banned KRAB thank you very much for the work done.
trance and completely inverter can not be found anywhere else.
Posts: I tvoei aid disabled sewn on the inverter qf132v4. burned a trans pripaevaem his back
43 did not and 10k resistor soldered to the chip 494 has nothing does not break legs 15
rezistor14-13.

ancl 05-10-2011 8:54


Party
Posts: Deprotection MP1008: 10k with 4 pins on the body.
85
MP1008.rar 14.05 KB Downloaded: 1448 time (s)

victor_l 19-10-2011 15:14


oza
Party Removing protection for BIT3193:
Posts: When the protection is activated the voltage at terminal 5 of about 3, 5 V.
50 When the voltage on pin 5, from 0.4 to 2.4V, and the command "start" PWM operates
autonomously, the lamp does not turn off.

Option - 1
Through a resistor 2 - 3 com pin 5 is connected to terminal 12 chips thus keep
"working" potential of about 1.2 V.
Option - 2
LED as stabistorov connected to pin 5 to ground-Live, "stabilizes" the voltage at
terminal 5 to 06 - 08 volts

does not work is not an Option ...


X1-42 30-10-2011 21:46
Party
Posts: OZ964 protection is removed as well as OZ960, 10 LED output.
40

KRAB 25-12-2011 15:51


monitor
.net.ru KAA here http://www.monitorlab.ru/forum/viewtopic.php?t=19695 wrote:
Shim backlight TA9687GN = OZ9933. Gathering Datasheet not found on
Posts: them. Stands in the PHILIPS 241E1SB / 01 = a part of the backlight
14071 ViewSonic VG2427wm. It may be useful to whom

saniy88 13-01-2012 22:59


81
Party Inl837gn withdrew protection from the monitor Acer V193Ab. On 4N (ISEN) should
Posts: be 1.48v. I did so: 5V through 10k connected the LED (selection) reached 1.5V. In the
51 "air" sent 4N and connected from the LED to this leg. This unit operates on a 3-lamps
(WMS whom it is useful)

Parazet 16-01-2012 15:09


am0l
Guest Controllers FAN7311 - FAN7314
46,117.
*. * Following the procedure Valentin, (this page) - 560 ohm resistor, to the housing 1
output.
Zener diode is not needed, such inclusion it still does not work.

http://www.datasheetdir.com/FAN7314A+CCFL-Controllers

JUDI71 08-02-2012 18:22


I want a
nickna OZ9938Q removed sewn, 10k parallel Conder 3 pin OZ9938
me!
Posts:
421
gchel 17-02-2012 21:41
Warnin
g: 2 TA9687GN ---- connect the output 12 TIMER through 47kom with Copus (parallel
S818). Checked.
Posts:
108

compor 22-02-2012 6:55


ator
Party The device LCD Sharp LC-32A47l, inverter 6 lamp on BD9897FS.
Posts: It was necessary to bypass the protection BD9897FS, in a trance korotnula one of
446 vtorichek - winding deleted.
Long tried to do something for the feedback, nothing happened. As a result, set-Live
LED on pin 17 BD9897 and body, which immediately disable the protection. The unit
earned run and successfully issued.
dak1uk 25-02-2012 17:05
r
Party SAMSUNG LE37R81B
Posts:
3209 Inverter - E206453 V144 (16 lamps, 8 transformers, power supply - 24V)

After a short exposure (less than 1 s.) Inverter is switched off.


When measuring the resistance of the windings increase, one was found, with a clear
deviation - 2 Com, instead of 2.2K (all others). Find similar transformer in private
households came to nothing.
Attempts to remove the transformer, off key, "washing" obratok from a nearby
transformer to nothing lead.
The remedy was simple:
1. Removes all dead winding.
2. On the vacated seat wound (observing the direction of winding) 22 turns of wire
0.41 that accounted for half of primary turns.
3. sealed transformer in place.
4. PIN homemade coil that goes to the lamp through the capacitor loaded on the body.

Capacitor need to pick up, comparing swings in the return signals converted winding
and working. In my case it turned out to 3300p.

Advantages of this method:


- There are no alterations in the inverter circuit.
- Working protection.
- Of the two lamps, one is working.
- If you find the right transformer old (with additional capacity) is removed, put in its
place a new, TV and again in working condition.

By the way, about this method, I have never read. Although, maybe just not in sight.

PS All collected on the "knee", so to speak experimental option. Client drove off for
two weeks, so it was time "to dig". TV has been working for a week. Tomorrow will
bring all in divine form, and you may start to give.
evg4682 01-03-2012 19:47
Noob
Posts: Controller QZ 9910 GN protection is turned off: LED with 3 feet stabistorov. Works
12 with one lamp, regulated only contrast. Monitor Aser al1716.

vaso5 01-03-2012 22:21


Wonder
ful QZ 9910 popular inverters beeches, and operates on a single lamp, it is possible to
employe alter according to the datasheet.
e
Posts: oz9910.rar 266 KB Downloaded: 1452 time (s)
288

ra4llb 10-03-2012 21:35


Warnin
gs: 1 evg4682 wrote:
Controller QZ 9910 GN protection is turned off: LED with 3 feet
Posts:
stabistorov. Works with one lamp, regulated only contrast. Monitor Aser
239
al1716.
Kurnool eh the gate transistors stabistorov hang!? But by 9 foot if the LED is
connected perfectly removes sewn!
asanik 17-03-2012 20:26
monitor
.net.ru AT1741S - LED display with 15 on the ground. I believe it is possible and resistor.
LED off.
Posts:
5830 AT1741 PDF

asanik 26-03-2012 21:50


monitor
.net.ru BD9883 LCD SHARP LC - XXX ... XXX ...
S5555erg wrote:
Posts: Disable protection on BD9883 --- you can use any LED 13 foot-SS, chips
5830 BD9883, --- anode, body ---- 7 cathode.
http://monitor.net.ru/forum/topic217133-0.html#3075355
Captain wrote:
AMIT wrote:
or just sit on the ground 12 foot.
http://monitor.net.ru/forum/topic217133-0.html#3075545
recommendation from Sharp.
http://monitor.net.ru/forum/topic217133-0.html#3075872

BD9883 PDF
SHARP INVERTER RUNTKA396WJGZ BD9883FV jumper C7528 - Off
zaschity.pdf 193.65 KB Downloaded: 1769 time (s)

asanik 08-05-2012 19:18


monitor
.net.ru Silver63 wrote:
NASERAT wrote:
Posts: SKI across multiple PWM DT8211. Protection bypass resistor decrease by 8
5830 foot. Instead of 200 ohms set 10-20 ohms.

It does not help. Can anyone have a way to remove the protection from this
Shima?

Silver63, do not ask questions here! But since you drew - then davayka and work
hard.
That's shit on the DT8211 - http://bbs.dianyuan.com/bbs/u/70/93971224214839.pdf
On page 9 you will find Protection (OLP, SCP). Moved machine -
Quote:
Protection (OLP, SCP)
An abnormal state is determined by the level of IFB. If IFB level is reduced
less than 0.75V DT8211 engaged in protection mode. This mode means that
one or more feedback current levels are very low. To switch to normal mode
IFB level should be higher than 0.75V. In the protection of the capacitor,
which is connected with the output PROT charged to 0.5uA. If the level is
on track PROT is a 3.0V DT8211 outputs are disabled. To resume work
after disconnecting DT8211, EN or VCC must move from a low to a high
level. Protection time is determined as shown below by the formula .....

Translator here - http://translate.google.ru/


Figure it out - lay out here ready-made solution, in fact, here in this thread only
thing that should be done.
Good Luck.
MYRA 13-05-2012 21:51
T
Party SONY KDL-40S2000
Posts:
136 BD9886FV

Protection starred closure pin 22 on the "ground", winding trance deleted.


vovan_j 07-06-2012 16:48
Guest
178,137. KRAB wrote:
*. * Samsung LE27T51B - inverter OZ960

3rd top transformer - loss of one of the windings -


AMIT wrote:
0Z960 - very easy way to remove protection - LED C10 put your
feet on the ground.
Winding resistance intact - 945 ohms.

Transformer installed and removed in accordance with the recommendations


of the LED. When viewed at an angle - a slight darkening in the area of the
lamp is off.

In my case it was stuck the first available under the arm trance with secondary
resistance 1.1K (native trances 2.2K) in parallel dead obmotki.Pervichka was
connected so as not to parallel.Rodnoy trans desoldering (one coil because live)
.Amplitudy buildup turned enough for two windings of primary parallelno.Nikakih
blackouts are not visible.
gosha_g 28-06-2012 15:20
or
Noob Deprotection of the inverter IC type MSC6512CPW ---- put resistance 10k + 12V
Posts: 2 LED series 5-pin chip, which is equal to 1.2 volts. Works OK ...

Deprotection of the inverter IC type LX1691A: Dana 14 foot chip called as OP-SNS
is grounded on the case. Works OK.
Benzopi 09-07-2012 9:02
ren
Banned To disable the MP1009
Short-circuit pin 5 on the body.
Posts:
52
bdvrt 30-07-2012 14:00
Warnin
gs: 1 OZT1060GN - sv.diod pin1

Posts: QZ9938GN - sv.diod pin3 ... for bit3193


66

gosha_g 09-08-2012 14:32


or
Noob Removing protection IC type MP10072E: 3 pin - LED on the case.
Posts: 2

Benzopi 19-09-2012 10:28


ren
Banned INL837GL
Stabilize the power at pin 12 - 1.7 - 2 V.
Posts: Connect stabistorov (LED) display with 12 on the ground,
571 to the same supply power from the source of 5 V through resistor 470 - 510 ohms.
kebasto 09/28/2012 13:36
s
The Supplement and I for LG 26LC2RA. ....
Sympat panel LC260WX2,
hy inverter master slave, master assembled on OZ99361 .....
Seeker You can change and 9936, but that's not it .... inverter chopped after turning over three
Posts: seconds off his defense ...... invented and there in the internet: see. photo below .....
1473 (shutdown protection this case is not dangerous for chopped inverter because
podsevshih bulbs) .... but! with such refinement it works, all is well, but every mode
of "standard" and AV1 inverter starts to squeal like a dog cut, while working .. ..... my
remake is a little different - hang in the air one leg micro and connect it through rezik
100k to 5 volts .... the figure is clay, going on 6 foot Micra .... well, between 1 foot
Micra and earth - kondёrchik 0.15 microfarads, and all - works great silence in all
modes
samurai 30/10/2012 11:41
-san
Grandf Already wrote about the two ways of locking OZ964 .Oba I have not worked.
ather The device LG 26LC2R-ZJ.BLRULB.Udalos lock setting resis- 17 foot 150-220kOM
Banzai! on korpus.Progorevshy trans deleted.
Posts: 2

asanik 04-12-2012 1:14


monitor
.net.ru LX6503A power supply + inverter BN44-00341B Samsung LE46C530F1W

Posts: Gogagogin wrote:


5830 Temporarily disable protection through 12N. Soft Start LX6503 backlight
is on, nothing is abnormally heated, but clearly underestimated the high
voltage to the lamp, the image is dim. Glow uniformly throughout the
matrix, similar to the lamp in order
Protection removed as shown in the attached file.
TV Title: LE46C530F1W model code: LE46C530F1WXRU Model:
LE46C530 panel: LTF460HM01 BN07-00815A 8BAE0M6POF
PFC to measure the voltage across the transistor inverter in the upper arm
when the inverter is running smoothly 385v. without jumps and dips.
http://monitor.net.ru/forum/viewtopic.php?t=444890&postdays=0& ...
http://monitor.net.ru/forum/viewtopic.php?t=444890&postdays=0& ...
http://monitor.net.ru/forum/viewtopic.php?t=239071&postdays=0& ...

SAMSUNG BN44-00341B_LX6503A.pdf 288.89 KB Downloaded: 743 time (s)

asanik 07-12-2012 00:55


monitor
.net.ru I think that will not interfere in the subject overview datasheet Drivers backlight series
OZxxxx -
Posts:
5830
http://www.o2micro.com.cn/prods/o2m_int_ltg_brochure.pdf

CCFL / EEFL Inverter Controller ICs

OZ964 ------- Wide Input Range Adaptive 20 SOP, SSOP


OZ965 ------- Fixed Input Voltage 16 SOP, TSSOP
OZ9910A ----- Dual Forward PWM Controller 16 SOP, SSOP
OZ9913 ------- Piezo Transformer Controller 20 SOP, SSOP
OZ9918 ------ SMBusTM ControllerController 24 SSOP
OZ9924 ----- LCD TV PWM Controller 20 SOP, SSOP
OZ9925 ----- TV Off-Line DC / AC Controller 16 SOP
OZ9926 ------ Large-Size LCD TV Controller 24 SSOP
OZ9926A ---- Large-Size LCD TV Controller 24 SOP, SSOP
OZ9928 ----- LCD TV Dual Controller 30 SSOP
OZ9935 ----- V-Sync Multi-Lamp Controller 16 SOP
OZ9936 ----- Precision Operating Frequency Controller 8 PDIP, SOP
OZ9937 ----- Universal LCD Panel Controller 16 SOP
OZ9938 ----- Multi-Lamp Controller 16 DIP, SOP
OZ9939 ----- Multi-Lamp Controller 16 DIP, SOP
OZ9970 ----- Low Cost LCD TV Controller 16 SOP

White LED ICs

OZ9950 ----- White LED Controller 8 MSOP, SOP


OZ9951 ----- Low Cost White LED Controller 8 SOP
OZ9953 ----- String LED Controller 20 SSOP
OZ9954 ----- Four String LED Controller 20 SSOP
OZ9955 ----- Eight String LED Controller 28 QFN
OZ9956A --- String LED Controller 20 QFN
OZ9957 ----- High Power LED Controller 16 SOP
OZ9958 ----- Three String LED Controller 16 QFN, SSOP
OZ9959 ----- Six String SMBusTM LED Controller 20 QFN

MOSFET Drivers

OZ9982 ----- Dual MOSFET Driver SOP 16

Light Sensors

OZ70 --------- Ambient Light Sensor 1206 SMD


OZ71B / G --- Blue and Green Light Sensor 1206 SMD
OZ72R ------ Red Light Sensor 1206 SMD

Power Management ICs

OZ9921 ----- Five-Channel DC / DC 28 QFN, SOP


OZ9922 ----- Power Management Controller 48 LQFP
OZxxxx.part1.rar 292.97 KB Downloaded: 1446 time (s)
OZxxxx.part2.rar 279.69 KB Downloaded: 1229 time (s)

asanik 12/14/2012 21:17


monitor
.net.ru BIT3713 - LED 5 O TIMER on the ground. LED off.

Posts:
5830 BIT3713 PDF

Added: looked theme found on BITxxxh like similar option here -


http://monitor.net.ru/forum/viewtopic.php?t=239071&postdays=0& ...

ra4llb 17/12/2012 16:30


Warnin
gs: 1 Apparatus ViewSonic N4060, inverter 24v40 w2s (see. Photo), protection is collected
on ms KA339, close enough to block capacitor C60.
Posts:
239
ra4llb 18/12/2012 20:46
Warnin
gs: 1 SEM2105 - to lock to put the LED on pin 1 of IC.

Posts:
239

asanik 12/25/2012 14:56


monitor
.net.ru BA9741 F 15 pin - SCP connected to the "earth." Thus protection is blocked on
both channels driver. (LCD CAMERON 1501SP)
Posts:
5830

BA9741 PDF

BA9741.JPG 41.35 KB Downloaded: 606 time (s)

ANOD0 02/05/2013 13:07


7
Party max8722 - for locking 4-pin to put on the ground.
Posts:
30
Jury 72 08/03/2013 18:00
Warnin
gs: 1 SEM2006 - Protection LED is removed with 2 pins on the body.

Posts:
340

Jury 72 12/03/2013 11:17


Warnin
gs: 1 MSC1692 - 4 pin resistor 220kOm on the body.

Posts:
340

Jury 72 03/31/2013 18:55


Warnin
gs: 1 KH0803A - LED or R 390 - 820 kOm with 5 pins on the body. (Parallel to the N125).

Posts:
340

Altai 04/08/2013 10:50


Guest
202,126. SP5005 - (sop16 4ccfl) LED 5 (timer) pin on the body.
*. *
OZ9910 in my case disable protection LED with 10 pins (not from the 9th)

Victora 24/04/2013 11:32


s
Party I confirm fears too simple ways to lock protection, Alex thing to say:
Posts: Rottor wrote:
591
mag58 wrote:
- I made and its contribution to the debate))
- Monitor starts, earned lights and turn off most.

This proposal has a nominal value of mites.


For a description of the method specify:
Rottor wrote:
The addition of two parts allows you to block the installation of
protection circuits constant brightness level adjustable
potentiometer.

What does it mean:


- Randomly assigned to sub-optimal brightness leads to excess current
consumption and overload clutches and inverter.
Hence the conclusion - saving potentiometer = rapid component failure due
to overload.

PS
For those who do not understand.
- Blocking protection disables the nominal brightness control by PWM.
- Potentiometer sets the required (constant) brightness value in the minimum
values of the current consumed by the inverter.
- As required adjustment (potentiometer) can be compensated by reducing
the intensity of the glow lamps.

Got LCD 37 ", one I / O section of the trance is broken, there is no backlight.
Inverter for OZ964, trans redkiy- inductance 1,36N / 0,17mN.

A simple way to 10n-LED load, but


Lamp Light neravnomerno.Sprava brightness too high, gradually decreases toward the
left side of the screen.
Naturally, the backlight is not regulated.
See unpleasant, and can be seen kirdyk lamps will come soon.

I had to return the damaged trans (per lamp works), the adjacent lamp hung trans-
donor in parallel.
Inductance coils donor below- very different. Redirect to both halves of the donor
sequence to bring the options to work.

Screen light evenly, perhaps one of the bulbs (the donor) is weaker, but not much.
Protection remains nominal, backlight adjustable.
ABDU 05/01/2013 13:42
Party
Posts: FAN7313 shutdown protection - c 17 pin IC LED to ground.
158

asanik 14/05/2013 13:56


monitor
.net.ru LX1692 ( for example, the TV SONY KDL-40S5600 )

Posts: 4 pin - C_TO - Time Out set capacitor LX1692 - close to the ground.
5830
roman7 20.06.2013 8:15
97
Guest BD9893 - disable protection can be planted on the ground pin 10 (scp) tested 100
95.32. *. percent, but the guys are not a panacea but only a method of searching for real cause
* of the problem!

In my case the TV SAMSUNG LE40B530P7 lost backlight inverter power supply


with combined BN44-00264C after manipulation protection discovered defect
Winding short circuit the secondary winding of the transformer 09TM02C item
number TI802S. Good luck to everyone!
shepher 07/01/2013 16:05
d
Party Suggested on another forum
Posts: for OZ9970GN
334
jurez 05/07/2013 14:24
Noob
Posts: BD9240 Unprotect possible by planting 15 foot (CP) through 10k to work
27 korpus.Perestaёt backlight adjustment panel.

BD9240.jpg 81.41 KB Downloaded: 457 time (s)

asanik 07.07.2013 1:02


monitor
.net.ru Ruslan, perekin PDF-ku in his post, please -

Posts: BD9240F / BD9240FV PDF


5830
BD9240F _ BD9240FV pdf.pdf 169.83 KB Downloaded: 494 time (s)

olegno1 07/20/2013 13:58


1
Noob Lock protection INL837 in complex cases.
Posts: 3
Rishat- 08/07/2013 11:08
80
Noob Another way to disable protection PWM controller MP1027EF.
Posts: 5 Rare controller, mainly installed in industrial firms monoblocks ADVANTECH.
PWM controller with a 20-pin, you have 16 pins are connected to ground through a
red LED. Proven, has been working for half a year.
nick s 30/08/2013 23:00
Party
Posts: you take a shit-date, podnimash legs MS and imitate voltage dividers.
1094

LGbaht 09.04.2013 9:42


-tel
Party OB3316QP remove protection you can: placing LED with 5pin IC to ground.
Posts:
525
Unprotect inverter 5N on zemlyu.jpg 79.65 KB Downloaded: 527 time (s)

Radioga 09/24/2013 13:21


d
Noob bd9884VF
Posts: 5
Deprotection tested on Erisson 26LH01 --- 17 pin chip is connected to a voltage
divider - cut the track after the divider, which goes to the DU - the error amplifier.
Radioga 10/28/2013 10:59
d
Noob OB3328UQP
Posts: 5
To remove protection, it suffices to establish the LED with 3pin IC to ground.

olegno1 10/11/2013 21:48


1
Noob To disable the on-chip BI3101
Posts: 3
Conclusion 16 chip close to common resistor 220 - 470 ohms
Kohl 20/11/2013 13:29
Party
Posts: BD9882F
865 LED from the 14th output to ground.

LGbaht 01.14.2014 6:47


-tel
Party BD9766VF.
Posts: LED 20 with the output of the mass.
525
CAIIIA 01/14/2014 21:46
Party
Posts: In inverter nouta MP1060EF defense took capacitor connected in parallel with 3 pin
487 chip on the weight of the white LED, the other colors are not checked.
yura_br 01/20/2014 13:56
t
Noob TA9687GN ---- connect the output 12 TIMER through 47kom with Copus
Posts:
12

KIRPIT 02/07/2014 11:51


CH
Noob To remove the protection OZ9937 must connect pin 14 TIMER 47kom through the
Posts: 7 housing (verified)

snack 02/20/2014 00:06


Warnin
gs: 1 Tried to disable protection OZ960 in Samsung 971p according to the method of 10N-
LED - LED blinks and still cuts off the PWM. In this case, does not work.
Posts:
173 Decision.

Anatoli 02/23/2014 21:07


y58
Party To remove the protection OZ9966SN must be connected via terminal 15 TIMER 10k
Posts: on housing (verified)
31

VUSA 15/03/2014 13:41


Party
Posts: BD9270F - 13 (cp) pin - 10k resistor on the body.
100
kebasto 04/01/2014 21:05
s
The OZ9976 (analogously OZ9966) - 10K on the housing with O TIMER, in this case, the
Sympat output circuit 11
hy
Seeker
Posts:
1473

ABDU 09/04/2014 16:24


Party
Posts: OZ972GN c 8 LED output to ground. Disabled in the inverter V370H-L01.
158

Lupik2 05/31/2014 14:11


Party
Posts: Good day!
33 BD9275F - 11 pin (CP External capacitor from CP to GND for Timer Latch) 1k on
the body (parallel Conder). First absolutely locked to the body - protection is disabled.
Tried with a resistor - protection is disabled. Adjusting the backlight works.
Checked ...
express 06/13/2014 11:47
el
Warnin OZ5508G / N - 3 pin cr. LED on the chassis (parallel to kondenz.). Adjusting the
gs: 1 backlight works.

Posts:
16

vovan_j 06/18/2014 13:15


Guest
46,118. DDA009
*. * On pin 18 (VCOMP) file 3v.

Xen 29/06/2014 11:27


Noob
Posts: OZ9643n - 1st pin 20 ohms to ground.
24
RadioEl 07/22/2014 12:33
ektroni
k BIT3251 - BIT3252 starred protection circuit 5 pin to ground
Noob
Posts: BIT3251.rar 191.22 KB Downloaded: 277 time (s)
17

vovan_j 08/18/2014 12:29


Guest
46,118. BD9276EFV
*. * Vlad-1966 wrote:
removed the protection LED on pin 35 (softstart).

LGbaht 26.08.2014 7:07


-tel
Party MP1007ES 4pin to ground.
Posts: scheme here
525

vovan_j 13/09/2014 10:02


Guest
46,118. ra4llb wrote:
*. *
SEM2105 - to lock to put the LED on pin 1 of IC.
+
nem wrote:
SEM2005 - protection is removed from the LED pin 1 on the body.
artur58 09.16.2014 8:03
Party
Posts: OZ9919GN 8pin through 10k to the ground.
114

yura371 09/21/2014 12:05


Noob
Posts: 1 To disable the inverter monitor LG Flatron W2271TC - FAN7314A
To disable the protection of the lower arm of need:
1. Break the chain between points 1 and 2 in the scheme (vypayat D303), if not help,
2. Break contacts the lower arm of the transformer, if not help,
3. vypayat diodes D404-D406

To disable all the protection you need:


Hang "the earth" through a resistor 560 ohms third point (1st pin FAN7314A)

Large size
Iskande 18/11/2014 11:35
r
Warnin UBA2074 to unprotect - 20kOm on housing with O 6. (6pin - CT - fault timing
gs: 1 capacitor)

Posts:
22

slfl 03/12/2014 11:50


Noob
Posts: 8 ILN816GN - Disabling security for BENQ E2420HD
Protection removed by setting resistor 10k in the eighth Pina, parallel capacitor C3.

In the beginning there is background noise, a few seconds after the lamp is fully lit
and operating correctly.
As it turned out - "noisy" high-voltage (3kV) capacitor that after several restarts his
way - probably not work 2 lamps.

Pinout and take off with a brief outline of another monitor:


http://tsimexico.com/tsi/dell/E190SfService%20Manual20090217.pdf and attach itself
pinout IC
CAIIIA 12/12/2014 19:47
Party
Posts: In LCD LG 32LK330-ZB Inverter VIT71884.00 REV: 2.LOGAH (OZ964 +
487 LM339) failed to win, then this works, it is not, but only managed to disable the
protection at the same time on 4 and 10 feet. Individually protection is not blocked.

LGbaht 01/07/2015 11:45


-tel
Party BD9215AFV put 10k resistor with a 15 pin IC to ground.
Posts: Datasheet here
525

fantom5 04/02/2015 19:52


55
Warnin Who could be useful in BD9896 veshaesh with third leg on the weight of the LED-
gs: 1 Live and the inverter is running despite not chto.U BD9897 is 17 noga.V general
Beres datasheet for the driver smotrish on any leg hangs external capacitor sets the
Posts: time delay protection , veshaesh with him on a lot of LED-Live and often the driver
152 begins to thrash despite not what ...

rammer 02/16/2015 15:44


monitor
.net.ru MP1038EY - LED on the 6th pin Fault Timing.

Posts:
4251

zharino 20.02.2015 9:43


v
Party UBA2070 - 1st leg to ground
Posts:
750

rz6anh 28/02/2015 11:41


Warnin
gs: 1 OZ9972. Variant with 24-pin package. Pin 20 (prot) through 1k on korpus.Vyvod the
scheme is not disabled.
Posts:
121

gchel 28/02/2015 21:27


Warnin
g: 2 DT8211 9 foot on the housing through kiloomny resistor, for example 47kom.

Posts:
108

You might also like