© LARSEN & TOUBRO HENIKWON S-Line Busduct System & Solution Technical Specifications ‘Aluminium - 250A to 50004 Busduct Rating Copper - 4008 to 63008 Rated Insulation Voltage (Ui) 1100v Rated Dielectric Voltage 2.5KV for 5 sec Pole Configurations 3P3W / 3PAW (50%N) / SPAW (100%N)} / 3P5W (200%N) ‘with of without 50% internal earth and provision for mounting external earth Insulation Material Multilayer Polyethylene Terephthalate (UL listed) Surface Coating on Enclosure Epoxy Powder Coating Degree of Protection 1P54 / IPSS for Indoor and IP6S /IP66 for Outdoor Tap-off Box: 100A to 12508 Seismic Compliance Zone 5, as per IS 1893 (Part 1) - 2002 and IEEE 693 - 2005 Tested with Vertical+Horizontal busduct and Plug-in Box assembly Resistance to Flame Propagation Verified Electrical Characteristics of Busducts Dimensions (Aluminium Busduct) see Te mee BR 2508 1-6 x30 135 4008 1-6 x40 135 : 6308 1-6 x60 135 ‘0 ny i 2 008 1-6 x80 135 120 " 3 14 10008 1-6 100 135 140 B 5 6 12508 1-6 125 135 165 5 7 8 16008 1-6 150 135 190 7 19 2 20008, 1-6 x 200 135 240 21 25 28 25008, 1-6x250 135 290 25 29 33 32008, 2-6x150 135 380 34 39 44 “40008 2-6x200 135 480 a2 48 55 50008, 3-6x200 135 n20 68 B 83 “ight gene ale igh fc weight Fan vay by 5H Dimensions (Copper Busduct) se wee BR +4908, 1-4x40 135 " 6308 1-6 x40 135 14 8008 1-650 135 a 2 5 18 10008 16x55 135 3 3 16 19 12508 1-675 135 113 7 2 25 16008 1-6 102 135 140 23 28 33 20008, 1-6 140 135 178 30 37 45 25008, 1-6 175 135 213 37 46 55 32004, 2-6x 102 135 280 49 56 70 40008 2-6x140 135 356 60 75 89 50008, 2-6x175 135 426 7 92 1 63004, 36x 160 135 594, 102 127 152 Weigh gives in above able sight Feeder weight eanvany by W5% Short Circuit Withstand Capacity Electrical Characteristics of Busducts Impedance at 50Hz (Aluminium Busduct) 6x80 1-6 x 125 1-6 x 200 2-6x150 50008, 3-6x200 Impedance at 50Hz (Copper Busduct) 11.92 Electrical Characteristics of Busducts Line-to-Line Voltage Drop at 50Hz (Aluminium Busduct) [ioos [0.80 |[085* || 0.80" [0.708 250A, 1-6x30 B61 867843 BIS 7.53 685 4008, 16x40 1013 980 ©6856 .18 8377.51 630A, 16x60 11731139 1088 «1053958 B57 8008, 1-6x80 1082 1065 1030981 8.05 B16 10008 1-6% 100 1015 1002 970-934-856 7.72 12508, 16x 125 1016 1005873838 B67. 78 16008 16x 150 1084 1074 1040 1003 | 9208.31 20008 4 -6x200 1015 1009878843 8677.84 25008 1-6x250 1016 1009 878943 8677.84 3200 2-6x150 1084 1074 1040 1003S 9.20831 4000 2-6x200 1016 1009 978 943 8677.84 50004, 3-6 200 1016 9838581 8a 754 “Power Factor Line-to-Line Voltage Drop at SOHz (Copper Busduct) a CSO CEOS Oo 3.80 4 8 735 4008 1-4x40 9.2 655 5308 16x40 9 993 3.70 84175 BOT ‘8008 1-6x50 999 1028 100587781 8.36 0008 16x55 W142 117811531122 10.47 9.63 12508 1-6x75 1073 1118 | 10.96 1068 1001 9.24 16008 1-6 x 102 1045 11.00 10.81 1056 9.93 8.19 20008 1-6 x 140 1002 1065 10.48 10.26 9.68 8.01 25008, 1-6x175 tosi 11251101087 1028.59 32008 26x 102 1045 11.01 1082-1056 9.93920 40008, 2-6x140 1002 1065 1049 10.26 9.69 9.01 ‘50008 2-6x175 1051 1125 1110 10.87 1029 9.59 53004, 3-6 x 160 936 999-885 864 8.12 8B Power Factor ‘Voltage Drop Calculation Formula = V3 XIL{R (AC) Cosa Kein) ‘Whe’: AV: Lne-olne Voltage Drop Ie Rated Current ROACH AC Resstance at Rated Curent (usm) X Reactance (sm) Sine: (0 = Cosis) Cosa: Load Power Factor System Components Feeder Feeder busduct takes power directy from A to B, Usually from power transformer / DG set to switchboard, or from switchboard to switchboard ‘Aluminium ‘Aluminium ‘50008, 3000 500 Copper 63004, 2 System Components Plug-in Feeder * Plug-in feeders are used for power distribution + Power is distributed through plug-in boxes {up to 400A) from plug-in feeder + Plug-in points shall be as per site requirement {up to a maximum of § on either side per 3-metre plug-in feeder) * The hole positions are determined by the space between the plug-in boxes and the length between the boxes and joint point Aluminio 2508 0 25008 3000 1200 copper 400A to 2500 ‘Aluminium 32008 to, 40008, — 3000 1200 Copper 3200A to. 50004, ‘Aluminium ‘50008, — 3000 1200 Copper 63004, Systern Components Vertical Eloow Vertical elbows are used to turn the busduct route up and down if itis running on its edge (when the busbars are vertical ‘Aluminium Busduct Copper Busduct 250 325x325, 4008 330x330 400A 330x330 6308 340x340 6308 330x330 ‘8008 350x350 8008 335x335 000A 500x500 360x360 100A 500x500 340x340 12508 370x370 12508, 350x350, 16008 390x380 16008 365 x 365, 2000 410x410 20008, 380 x380 25008 440x440 25008, 400 x 400 nium Bust ‘Copper Busduet 3200A, 480x480 320A 435 x 435 40004 700700 530x530 | 4000A 700x700 470x470 : - = 50008 505 x05 Copper Busduct 700x700 650x650 - - ~ 63008, 700x 700 580x590 2

You might also like