MSDS DEL VARSOL= SOLVENTE 3

EXXON CHEMICAL AMERICAS/A DIV OF EXXON CORP -- VARSOL 18


SOLVENT, PD 680B TYPE I -- 6850-00-264-9038
===================== Product Identification =====================

Product ID:VARSOL 18 SOLVENT, PD 680B TYPE I


MSDS Date:04/03/1995
FSC:6850
NIIN:00-264-9038
Status Code:A
MSDS Number: CJHTX
=== Responsible Party ===
Company Name:EXXON CHEMICAL AMERICAS/A DIV OF EXXON CORP
Address:13501 KATY FWY
Box:3272
City:HOUSTON
State:TX
ZIP:77253-3272
Country:US
Info Phone Num:713-870-6000
Emergency Phone Num:713-870-6000
Resp. Party Other MSDS Num.:MSDS # 92891624
CAGE:72190
=== Contractor Identification ===
Company Name:DOMINION CHEMICAL CO
Address:2050 PUDDLEDOCK RD
Box:1069
City:PETERSBURG
State:VA
ZIP:23803
Country:US
Phone:804-733-7628
CAGE:9A273
Company Name:EXXON CHEMICAL CO USA SALES OFFICE
Address:1333 W LOOP S
Box:3272
City:HOUSTON
State:TX
ZIP:77253
Country:US
Phone:281-870-6000/6884
CAGE:4H542
Company Name:EXXONMOBIL CHEMICAL CO, DIV OF EXXON MOBILCORP.
Address:13501 KATY FWY
Box:3272
City:HOUSTON
State:TX
ZIP:77253-3272
Country:US
Phone:281-870-6000 / 800-726-2015
Contract Num:SP0450-98-D-4154
CAGE:72190

============= Composition/Information on Ingredients =============


Ingred Name:PROPRIETARY INGREDIENTS (COMPONENTS: PETROLEUM HYDROCARBON,
TRIMETHYL BENZENE, STODDARD SOLVENT)
Fraction by Wt: 100%
Other REC Limits:NONE SPECIFIED

===================== Hazards Identification =====================

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES


Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE-SLIGHTLY IRRITATING BUT DOES NOT
INJURE EYE TISSUE. SKIN-OCCASIONAL BRIEF CONTACT WILL NOT RESULT IN
SIGNIFICANT IRRITATION UNLESS EVAPORATION IS IMPEDED.
INHALATION-HIGH VAPOR CONCENTRATIONS ARE IRRIATING TO THE EYE &
RESPIRATORY TRACT. LOW ORDER OF TOXICITY. INGESTION-SMALL AMOUNTS
OF THE LIQUID ASPIRATED INTO THE RESPIRATORY SYSTEMDURING INGESTION
OR VOMITING MAY CAUSE MILD TO SEVERE PULMO NARY INJURY, POSSIBLY
PROGRESSING TO DEATH.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:INHALATION-MAY CAUSE HEADACHES, DIZZINESS,
ANESTHESIA, DROWSINESS, UNCONSCIOUSNESS, AND OTHER CENTRAL NERVOUS
SYSTEM EFFECTS, INCLUDING DEATH. LOW ORDER OF TOXICITY.
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS CONDITION.

======================= First Aid Measures =======================

First Aid:EYES-FLUSH WITH LARGE AMOUNTS OF WATER UNTIL IRRITATION


SUBSIDES. IF IRRITATION PERSISTS, GET MEDICAL AID. SKIN-FLUSH WITH
LARGE AMOUNTS OF WATER; USE SOAP IF AVAILABLE. REMOVE GROSSLY
CONTAMINATED CL OTHING. INHALATION-USING PROPER RESPIRATORY
PROTECTION, IMMEDIATELY REMOVE THE EFFECTED VICTIM FROM EXPOSURE.
ADMINISTER ARTIFICIAL RESPIRATION IF BREATHING IS STOPPED. KEEP AT
REST. CALL FOR PROMPT M EDICAL AID. INGESTION-IF SWALLOWED. DO NOT
INDUCE VOMITING. KEEP AT REST. GET PROMPT MEDICAL ATTENTION.

===================== Fire Fighting Measures =====================

Flash Point Method:TCC


Flash Point:=40.C, 104.F
Autoignition Temp:=254.4C, 490.F
Lower Limits:2.3
Upper Limits:14.4
Extinguishing Media:USE FOAM, DRY CHEMICAL, OR WATER SPRAY TO
EXTINGUISH FIRE. AVOID SPRAYING WATER DIRECTLY INTO STORAGE
CONTAINERS DUE TO DANGER OF BOILOVER.
Fire Fighting Procedures:USE WATER SPRAY TO COOL FIRE EXPOSED
CONTAINERS & TO PROTECT PERSONNEL. SHUT OFF "FUEL" TO FIRE. IF LEAK
OR SPILL HASN'T IGNITED, DISPERSE VAPORS WITH WATER.
Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID, CAN FORM COMBUSTIBLE
MIXTURES AT TEMPERATURES AT OR ABOVE THE FLASHPOINT.

================== Accidental Release Measures ==================

Spill Release Procedures:ELIMINATE SOURCES OF IGNITION. PREVENT


ADDITIONAL DISCHARGE OF MATERIAL, IF POSSIBLE TO DO SO WITHOUT
HAZARD. FOR SMALL SPILLS IMPLEMENT CLEANUP PROCEDURES; FOR LARGE
SPILLS IMPLEMENT CLEANUP PROCEDUR ES AND, IF IN PUBLIC AREA, KEEP
PUBLIC AWAY AND ADVISE AUTHORITIES. ALSO, IF THIS PRODUCT IS
SUBJECT TO CERCLA REPORTING NOTIFY THE NATIONAL RESPONSE CENTER.

====================== Handling and Storage ======================

Handling and Storage Precautions:KEEP CONTAINER CLOSED. HANDLE AND OPEN


CONTAINERS WITH CARE. STORE IN A COOL, WELL VENTILATED PLACE AWAY
FROM INCOMPATIBLE MATERIALS. DO NOT HANDLE OR STORE NEAR AN OPEN
FLAME, HEAT OR OTHER SOURCE OF IGNITION. PROTECT MATERIAL FROM
DIRECT SUNLIGHT.
Other Precautions:STATIC DISCHARGE, MATERIAL CAN ACCUMULATE STATIC
CHARGES WHICH CAN CAUSE AN INCENDIARY ELECTRICAL DISCHARGE.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:A NIOSH/MSHA APPROVED RESPIRATOR MAY BE


NECESSARY TO PREVENT OVEREXPOSURE BY INHALATION.
Ventilation:MECHANICAL DILUTION VENTILATION IS RECOMMENDED. USE
EXPLOSION PROOF VENTILATION EQUIPMENT.
Protective Gloves:CHEMICALLY RESISTANT GLOVES
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS
Other Protective Equipment:WEAR LONG SLEEVES. HAVE EMERGENCY EYE WASH
AND SAFETY SHOWER AVAILABLE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING.
Supplemental Safety and Health
EMPTY CONTAINERS RETAIN PRODUCT RESIDUE AND CAN BE DANGEROUS. DO NOT
PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND OR EXPOSE SUCH
CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY OR OTHER SO
URCES OF IGNITION. THEY MAY EXPLODE ANDCAUSE INJURY OR DEATH.

================== Physical/Chemical Properties ==================

HCC:F4
Boiling Pt:B.P. Text:315 TO 397F
Melt/Freeze Pt:=-20.C, -4.F
Vapor Pres:6 MMHG @60F
Spec Gravity:3.90, CALCULATED
Evaporation Rate & Reference:1 (N-BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR COLORLESS LIQUID WITH A PETROLEUM ODOR.

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES


HALOGENS, MOLTEN SULFUR, STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:NONE.

===================== Ecological Information =====================

Ecological:NO SPECIFIC ECOLOGICAL DATA ARE AVAILABLE FOR THIS PRODUCT.

==================== Disposal Considerations ====================


Waste Disposal Methods:CONSULT AN EXPERT ON DISPOSAL OF RECOVERED
MATERIAL AND ENSURE CONFORMITY TO LOCAL DISPOSAL REGULATIONS.

=================== MSDS Transport Information ===================

Transport Information:DOT SHIPPING DESCRIPTION; PETROLEUM DISTILLATE,


N.O.S. COMBUSTIBLE LIQUID, UN 1268, III. NOTE: IN CONTAINERS OF 119
GALLONS CAPACITY OR LESS THIS PRODUCT IS NOT REGULATED BY DOT.

===================== Regulatory Information =====================

SARA Title III Information:1,2,-TRIMETHYL BENZENE, CAS # 95-63-6, 2.0%.


Federal Regulatory Information:CERCLA: IF THIS PRODUCT IS ACCIDENTALLY
SPILLED, IT IS NOT SUBJECT TO ANY SPECIAL REPORTING UNDER THE
REQUIREMENTS OF CERCLA. WE RECOMMEND YOU CONTACT LOCAL AUTHORITIES
TO DETERMINE IF THERE MAY BE OT HER LOCAL REPORTING REQUIREMENTS.
TSCA: THIS PRODUCT IS NOT LISTED UNDER TSCA INVENTORY AS A UVCB.

Disclaimer (provided with this information by the compiling agencies):


This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
TRADUCIENDO
MSDS Number: CJHTX
(DESPUÉS DE ESTO)

Partido(Parte) Responsable
Empresa Name:EXXON SUSTANCIA QUÍMICA AMERICAS/A DIVISIÓN DE
CORPORACIÓN EXXON
City:PETERSBURG
State:VA
ZIP:23803
Country:US

============= Composition/Information on Ingredients =============

Composición / Información sobre Ingredientes

Ingred Nombre: PROPIEDAD INGREDIENTES (COMPONENTES: PETRÓLEO POR


HIDROCARBUROS,
     TRIMETHYL BENCENO, STODDARD SOLVENT)
Fracción por Peso: 100%
Otros REC límites: no especificado
===================== Hazards Identification =====================
Identificación de Peligros
Rutas de Entrada: Inhalación: SI Piel: SI Ingestión: SI
Informes de Carcinogenicidad: NTP: NO IARC: NO OSHA: NO
Los peligros para la salud agudos y crónicos: ojos ligeramente irritante,
pero no
     Lesionar a los tejidos del ojo.
Los peligros para la salud agudos y crónicos: ojos ligeramente irritante,
pero no
     Lesionar a los tejidos del ojo. Piel - de vez en cuando un breve
contacto no en el resultado
     Significante irritación a menos que la evaporación se ve
obstaculizado.
La inhalación de concentraciones de vapor de alta son IRRIATING al ojo &
     TRACTO RESPIRATORIO. Bajo orden de toxicidad. La ingestión de
pequeñas cantidades La aspiración de líquido en el aparato respiratorio
SYSTEMDURING ingestión
     O puede causar vómitos leves o graves PULMO rio lesión, posiblemente

     Progresa a la muerte.


Explicación de carcinogenicidad: este compuesto no contiene ingredientes
en Concentraciones de 0,1% o más agentes carcinógenos o que se sospecha
CARCINÓGENOS.
Efectos de Overexposure: INHALACIÓN - MAY CAUSE HEADACHES, DIZZINESS,
Anestesia, somnolencia, inconsciencia, y otros nervioso central
     EFECTOS DEL SISTEMA, EN PARTICULAR LA MUERTE. Bajo orden de
toxicidad. Médico Cond agravadas por la exposición: el contacto con la
piel puede agravar una
     La dermatitis condición existente.

======================= First Aid Measures =======================


Medidas de primeros auxilios

Primeros Auxilios: ojos - Lavarse con gran cantidad de agua hasta que la
irritación
     SUBSIDES. Si la irritación persiste, obtenga ayuda médica. Ras con
la piel - Grandes cantidades de agua, uso de jabón si está disponible.
RETIRAR GROSSLY
     Contaminados CL OTHING. Inhalación - usando respiratorio adecuado
Protección, eliminar inmediatamente la víctima de la exposición
efectuada.
     Administrar respiración artificial si la respiración se para.
MANTENER EN REST. CONVOCATORIA DE P OR pronta ayuda. INGESTIÓN - EN CASO
DE INGESTIÓN. NO
     INDUCE VÓMITOS. Mantenerla en reposo. Obtener atención médica de
inmediato.

===================== Fire Fighting Measures =====================


Medidas de lucha contra incendios

Flash Point Método: TCC


Flash Point: = 40.C, 104.F
Auto- Temp: = 254.4C, 490.F
Límite inferior: 2,3
Límites superior: 14,4
Medios de extinción: el uso de espuma, químico seco, o rocío de agua para

     EXTINGUISH FUEGO. Evitar la pulverización de agua directamente en el


almacén
     Contenedores debido al peligro de BOILOVER.
Los procedimientos de lucha contra el fuego: el uso de aspersión con agua
para enfriar el fuego expuestas
     CONTENEDORES PARA PROTEGER A & PERSONAL. APAGADO "COMBUSTIBLE" AL
FUEGO. SI FUGAS
     O derrame no se ha encendido, dispersar vapores de agua.
Unusual Fire / riesgo de explosión: combustibles líquidos, pueden formar
combustibles
     Mezclas a temperaturas iguales o superiores a la de inflamación.

================== Accidental Release Measures ==================

Medidas de Derrame Accidental


Spill liberación Procedimiento: eliminar las fuentes de ignición.
PREVENIR
     Adicional de descarga del material, si es posible hacerlo sin
     PELIGRO. Para los pequeños derrames de aplicar procedimientos de
limpieza, para las grandes
     Limpieza de derrames de aplicar ES de procedimiento y, si en el área
pública, mantener
     Lejos público y asesorar a las autoridades. También, si el producto
ha sido
     CERCLA sujeta a la presentación de informes notificar al centro
nacional de respuesta.

You might also like