SC 995
SC 995
Then go to copy SP, then SP5882 (CPM) and change to the initial setting.
I experienced exactly the same problem: we installed a 2500 controller in a 3000 &
the result was the same as yours. Finally after 3 burning brains, 12 hours of hard
work and the replacement of every board (bcu, controller, iob, nvram...), I decided
to go to copytechnet.com... And the result is that I repared the R59 fuse on the
IOB. The code is fixed! Many thanks to Cipher who wrote this solution a few
months ago.
R59 is on the back of the IOB. Took me forever to find it, but it also not there.
ok i just cleared a sc995 code with the svc mode 5882 on a mpc3000 ! It was on 2
initial was 1, i reset it to one re booted, Problem gone
Thanks Guys
I would like to thank you for your quick reply and tips.
I replaced the I/O board and that sorted the problem :-) thanks for pointing me in
the right direction
Masterchief