You are on page 1of 2

Tech Manual Excerpt

FilmTec™ Elements Operating Limits


Temperature and Pressure Limits for 8-inch FilmTec™ Seawater RO
Elements

Introduction Exposure of spiral-wound membrane elements to extreme conditions during RO


operation can lead to reduced permeate flow, increased salt passage, and
deformation or failure of element components. Consequently, FilmTec™ Elements
are subject to certain operating limits, including limits on feed pressure and
temperature. This document provides general temperature and pressure limits for 8
inch FilmTec™ Seawater Elements.

Important Note Regarding Your Warranty: Failure to meet the requirements set
forth in this document will void your element warranty. Refer to your governing
document – either product data sheet, element warranty, or system warranty – for
the operating limits that apply to your elements.

Elements with Most FilmTec™ Seawater RO Elements are approved for operation up to 45°C and 83
Standard Endcaps bar (1200 psi). If your planned operating conditions fall inside the shaded region in
Figure 1, contact your DuPont representative for further information. If conditions
include feed pressure above 42 bar (600 psi) and feed temperature above 40°C,
special attention to vessel shimming is required. Refer to Shimming Elements
(Form No. 45-D01057-en).

Figure 1: Temperature and Pressure Limits for Elements with Standard


Endcaps

Page 1 of 2 Form No. 45-D00691-en, Rev. 1


January 2020
Elements with Most FilmTec™ Seawater RO Elements with iLEC™ Interlocking Endcaps are
iLEC™ Interlocking approved for operation up to 45°C and 83 bar (1200 psi). If your planned operating
Endcaps conditions fall inside the shaded regions in Figure 2, contact your DuPont
representative for further information. If conditions include feed pressure above 42
bar (600 psi) and feed temperature above 35°C, the installation of internal
interconnectors (DuPont Part No. 313198) is required. The elements should be left
unlocked to allow for thermal expansion and contraction. If conditions include feed
pressure above 42 bar (600 psi) and feed temperature above 40°C, special attention
to vessel shimming is required. Refer to Shimming Elements
(Form No. 45-D01057-en) ).

Figure 2: Temperature and Pressure Limits for Elements with iLEC™


Interlocking Endcaps

Excerpt from FilmTec™ Reverse Osmosis Membranes Technical Manual (Form No. 45-D01504-en), Chapter 3, "System Design."

Have a question? Contact us at: All information set forth herein is for informational purposes only. This information is general information and may differ from that
based on actual conditions. Customer is responsible for determining whether products and the information in this document are
www.dupont.com/water/contact-us
appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with
applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or
available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries.
Please note that physical properties may vary depending on certain conditions and while operating conditions stated in this
document are intended to lengthen product lifespan and/or improve product performance, it will ultimately depend on actual
circumstances and is in no event a guarantee of achieving any specific results. DuPont assumes no obligation or liability for the
information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to
Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. No freedom from infringement of any patent or
trademark owned by DuPont or others is to be inferred.

DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® are owned by affiliates of
DuPont de Nemours Inc. unless otherwise noted. © 2020 DuPont.

Page 2 of 2 Form No. 45-D00691-en, Rev. 1


January 2020