The sheeting material shall be ZINCALUME® protected steel sheet to Australian Standard AS 1397 with a minimum
yield stress of 300MPa (Grade G300), metallic hot-dip coated with ZINCALUME® zinc/ aluminium alloy-coated steel
comprising 55% aluminium, 43.5% zinc and 1.5% silicon. The minimum coating mass for the ZINCALUME® zinc/aluminium
alloy - coated steel shall be AZ 150 (150 g/m2 minimum coating mass) or more as determined by Australian Standard
AS 1397.
Wherever applicable, the installation of the metal sheets shall be in accordance to the “Installation code for metal
roofing and wall cladding; Standards Australia SAA HB39-1997”. The sheets shall be installed in accordance to
manufacturer’s recommendations. The fasteners used to secure the metal sheets to the supports shall conform to
Australian Standard AS 3566 and be compatible with the roofing material used.
Sheets shall be laid in such a manner that the approved side lap faces away from the prevailing weather. A minimum
of 30mm shall be provided for projection into gutters. Flashings shall be supplied in compatible materials as specified,
minimum cover of flashing shall be 150mm.
All sheets shall be fixed in a workman like manner, leaving the job clean and weather-tight. All debris (nuts, screws,
cuttings, filings etc.) shall be cleaned off daily.
TECHNICAL SPECIFICATION
LCP LYCORTILE® modules are manufactured from high quality premium grade factory pre-painted steel material.
High Strength Steel Grade : High strength steel with minimum yield strength of 300MPa, metallic hot-dip coated
with aluminium/zinc alloy comprising 55% aluminium, 43.5% zinc and 1.5% silicon.
The minimum coating mass for the aluminium/zinc alloy coated steel shall be AZ
150 (150g/m² minimum coating mass) or AZ 200 (200g/m² minimum coating mass).
Nominal Steel Thickness : 0.42mm Base Metal Thickness (BMT). Other thicknesses are available upon request.
Standard Colour Coating : Clean COLORBOND®. Other types of paint finishes are also available upon request.
Nominal Cover Width : 1000mm wide sheets, with allowable tolerance of ± 4mm.
Minimum Roof Pitch : 12 degrees. Please check with LCP Building Products Pte. Ltd., Technical Department,
for specific details regarding roof pitch.
LYCORTILE PROFILE
RENOVATION/NEW CONSTRUCTION ON
TIMBER BOARDING OR PLYWOOD PANELS
LCP LYCORTILE® can be laid on timber boarding or
plywood or panels, which are at least 17mm thick.
Typical timber roofing tiling battens* are 25mm × 50mm
in size. These tiling battens* must be laid on counter
battens* of size 25mm×25mm running down the slope
at 600mm centres. For LCP LYCORTILE® with 300mm step
distance per module, the tiling batten* spacing must be
300mm except at the bottom where spacing is reduced
to 280mm.
*: For steel battens, Please contact LCP Building Products Pte. Ltd., Technical Department.
Eaves
FIXING PLAN
Side Overlaps
The standard step distance per module is 300mm, 400mm Crest Fixing:
and 500mm; other step distances are also available ranging For steel batten, use No. 12 × 68mm hex head self-drilling, self-
between 300mm to 500mm upon request. please contact LCP tapping screws with neoprene washers. For timber batten,
Building Products Pte. Ltd., Technical Department. Lengths of (F11 grade timber or better), use No. 12 × 65mm hex head self-
LCP LYCORTILE® come in multiples of the modules plus 130mm. drilling type 17 screws with neoprene washers.
LCP LYCORTILE® can be supplied in any length up to the limit
of local transportation regulations, subject to multiples of Do not over-tighten screws, ensure they are kept upright and
module plus 130mm. Lengths specified must be actual site that neoprene washers remain in position during installation.
measurements and not plan dimensions. The length should Ranges of “Cyclone” caps are available for even better
be measured accurately, and allowance should be made for wind load performance. Increase screw length by 10mm for
clearance at the ridge of normally around 30mm and at the installation on soft wood applications. Lead head nails must
eave, an overhang into the gutter which is normally 30mm. The not be used.
tolerance of the length of product supplied is +0, -15mm.
CUTTING
FLASHING
Sheeting can be cut, where necessary, by means of metal
Standard flashings are readily available for use with snips or electric nibbler. The use of cutting discs should be
LCPoLYCORTILE® roofing. LCP Building Products Pte. Ltd. will give avoided but if it is used, the Clean COLORBOND® pre-painted
design advice for flashing details and will manufacture the steel sheeting should be placed downwards, or carefully
required flashing. shielded, to minimize the risk of hot filings embedding in the
painted surface.
CLEAN UP
Ensure that all debris, nails, rivets, screws, rags, and especially
filings & particles from cutting or drilling, are carefully cleared
from the surface after each day’s work or premature corrosion
could occur.
IMPORTANT NOTE: The information published in this brochure is as far as possible accurate at the date of publication, however, prior
to application in a particular situation, LCP Building Products Pte. Ltd. recommends that you obtain qualified expert advice confirming
the suitability of product(s) in question for the application proposed. While LCP Building Products Pte. Ltd. accepts its legal obligations,
be aware however that to the extent permitted by law, LCP Building Products Pte. Ltd. disclaims all liability (including liability for
negligence) for all losses and damages resulting from the use of the information provided in this brochure.
LCP BUILDING PRODUCTS PTE. LTD. LCP BUILDING PRODUCTS PVT. LTD. Photographs of the premises displayed in
CO. No. 200009173 C (CO. No. U28112 TN2004 PTC053236) this Brochure are not to be construed as an
endorsement or recommendation by the owners
No. 6 Gul Circle, Singapore 629562 Old No.6, New No.17, 4th Floor, of the premises to LCP and its products.
Viswanathapuram Main Road, LCP LYCORTILE® Brochure 05/2018 ©2018 LCP
BUILDING PRODUCTS
Tel: (65) 6865-1550 Fax: (65) 6861-4218 Kodambakkam, Chennai – 600 024, India Building Products Pte. Ltd. All rights reserved.
Email: lcp@lcp.sg website: www.lcp.sg
LCP LYCORTILE® Brochure 05.2018 edition.
Tel: + 91-44 -298 92772
Fax: + 91-44 -298 92772 Clean COLORBOND®, COLORBOND® and
Email: lcpindia@lcpgroup.asia ZINCALUME® are registered trademarks of
website: www.lcpindia.com BLUESCOPE STEEL LIMITED