You are on page 1of 78

Valve terminals type 32 MPA

Valve terminals type 32 MPA


Key features

Innovative Versatile Reliable Easy to mount


• Slim high-performance valves in • Modular system offering a range of • Sturdy and durable metal • Ready-to-install unit, already
sturdy metal housing configuration options components assembled and tested
• MPA1 flow rates up to 360 l/min • Expandable up to 128 solenoid coils – Valves • Lower selection, ordering, installation
• MPA2 flow rates up to 700 l/min • Conversion and expansion possible – Manifold blocks and commissioning costs
• From the individual valve to the valve at a later date – Seals • Secure mounting on wall or H-rail
terminal with multi-pin plug, • Further manifold blocks can be • Fast troubleshooting thanks to LEDs mounting
AS-interface, CPI and fieldbus assembled using just three screws on the valves and diagnostics via
connections and control block and sturdy separating seals on metal fieldbus
• Dream team: fieldbus valve terminal separator plates • Extensive operating voltage range
suitable for electrical peripherals • Integration of innovative function ±25%
CPX. This means: modules possible • Ease of servicing through replaceable
– Forward-looking internal • Manual regulators, rotatable valves and electronics modules
communication system for pressure gauges • Manual override either
actuation of the valves and CPX • Proportional pressure regulators non-detenting, detenting or secured
modules • Additional air supply via additional against unauthorised activation
– Diagnostics down to the individual pressure zones using supply plates (covered)
valve • Wide range of pressures • Durable, thanks to tried and tested
– Valves can either be actuated via –0.9 … 10 bar piston spool valves
separate voltage supply or without • Wide range of valve functions • Large and durable labelling system,
electrical isolation (without as suitable for barcodes
standard)

2 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve terminals type 32 MPA
Key features

Reduced downtimes: Reliable operation:


Two-colour LED diagnostics on site Manual override non-detenting/detenting or with cover

Width 10 mm and 20 mm
Compact:
Slim valves and flat plate silencers
Pneumatic interface to CPX

Straightforward electrical onnections Flexible:


– Multi-pin plug connection – 64 valve positions/128 solenoid coils (FB)
– Fieldbus connection – 24 valve positions/24 solenoid coils (MP)
– Control block
– AS-interface Functional:
– CPI Sturdy metal thread or pre-assembled QS
fittings
CPX diagnostic interface for handheld
Modular:
devices (channel-oriented diagnostics
Supply plates facilitate the creation of multiple
down to the individual valve)
pressure zones as well as numerous additional
Quick mounting: exhaust and supply ports
Directly using screws or on a H-rail,
Wide range of valve functions
automatic earthing

Safe: Practical:
Operating voltage connection ±25%, outputs Large inscription labels
and valves can be disconnected separately

Equipment options
Valve functions
• 5/2-way valve, single solenoid • 5/3-way valve, mid-position • 2x 2/2-way valve, normally closed • Proportional pressure regulators
• 5/2-way valve, double solenoid pressurised • 1x 3/2-way valve, normally closed, • Pressure sensor
• 2x 3/2-way valve, normally open • 5/3-way valve, mid-position closed external compressed air supply All valves have the same compact
• 2x 3/2-way valve, normally closed • 5/3-way valve, mid-position • 1x 3/2-way valve, normally open, dimensions with an overall length of
• 2x 3/2-way valve, exhausted external compressed air supply 107 mm and a width of 10.5 mm or
1x normally open, • 2x 2/2-way valve, • Manual pressure regulators 21 mm. A height of 55 mm makes them
1x normally closed 1x normally closed, a perfect match for the electrical
1x normally closed, reversible peripherals CPX.

Special features
Multi-pin terminal Fieldbus terminal/control block Individual valve CPI interface
• Max. 24 valve • Max. 64 valve • Electrical M8 connection, 4-pin with • Max. 32 valve
positions/max. 24 solenoid coils positions/max. 128 solenoid coils screw connection positions/max. 32 solenoid coils
• Parallel modular valve linking via • Internal CPX bus system for valve • Detachable electronics module with
circuit boards actuation integrated holding current reduction Combinable
• Electronics module with integrated • Module for electrical valve actuation, AS-interface • MPA1 flow rates up to 360 l/min
holding current reduction via separate voltage supply or • 2 to 8 valves, freely configurable • MPA2 flow rates up to 700 l/min
• Any compressed air supply without electrical isolation (max. 8 solenoid coils) with input • MPA1 and MPA2 can be combined on
• Any number of pressure zones • Any compressed air supply feedback one valve terminal
• Any number of pressure zones

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 3


Valve terminals type 32 MPA
Key features

Equipment options (continued)


Electrical supply plate
• Increases the maximum number of • Greater economy thanks to the higher
Note
valve positions possible to 64, with number of valves/solenoid coils per
max. 128 solenoid coils valve terminal The electrical supply plate is available
• Facilitates the creation of electrically • Greater safety through individual with either an M18 or 7/8”
isolated, individually disconnectable disconnection of valve groups, for connection.
voltage zones example for EMERGENCY-STOP
functions

Valve terminal configurator Online via:  www.festo.com/us/engineering


Selecting an MPA valve terminal using
the online catalogue is quick and easy
thanks to the convenient valve terminal
configurator provided. This makes it
much easier to find the right product.

The valve terminals are fully assembled


according to your order specifications
and are individually tested. This
reduces the assembly and installation
time to a minimum.
The valve terminal type 32 is ordered
using the order code.

Ordering system for type 32


 www.festo.com/catalog/mpa

Ordering system for CPX


 www.festo.com/catalog/cpx

2D/3D CAD data Online via:  www.festo.com/us/engineering


You can request the CAD data for a valve (compass). On the next page you can
terminal you have configured. To do so, generate a 3D preview or request
perform the product search as another data format of your choice by
described above. Go to the shopping e-mail.
basket and click on the CAD icon

4 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve terminals type 32 MPA
Key features

Individual connection
Valves can also be used on individual The electrical connection is established
sub-bases for actuators further away using a standard 4-pin M8 plug
from the valve terminal. (EN 60947-5-2).

Multi-pin plug connection


The signal flow from the controller to the The valve terminal can be equipped Versions
valve terminal takes place via a with max. 24 solenoid coils. This • Sub-D connection
pre-assembled or self-assembled corresponds to 4 to 24 MPA1 or 2 to 24 • Pre-assembled multi-pin cable
multi-wire cable to the multi-pin plug MPA2 valves, or a combination of both. • Multi-pin cable for self-assembly
connection, which substantially reduces
installation time.

AS-interface connection
A special feature of the AS-interface is • With two to eight modular valve The connection technology used for the
its ability to simultaneously transmit positions (max. 8 solenoid coils). This inputs can be selected as with CPX: M8,
data and supply power via a two-wire corresponds to 2 to 8 MPA1 or 2 to 8 M12, Harax, Sub-D, Cage Clamp®
cable. The encoded cable profile MPA2 valves, or a combination of (terminals to IP20).
prevents connection with incorrect both.
polarity. • With all available valve functions. Further information
The valve terminal with AS-interface is  www.festo.com/catalog/as-interface
available in the following versions:

CPI installation system


Valve terminal for CPI installation Four strings with up to 32 inputs and
system: outputs can be connected to a fieldbus
Valve terminals with CP connection are node or control block. The connecting
intended for connection to higher-order cables transmit the power supply for the
fieldbus nodes or to control blocks. A input modules and the load voltage for
fieldbus node or control block also the valves as well as control signals.
enables the connection of decentralised
input/output units. The following Further information
fieldbus protocols are supported:  www.festo.com/catalog/cpi
• Festo fieldbus, ABB CS31,
Moeller Suconet K
• Interbus
• Allen Bradley (1771 RIO)
• DeviceNet
• Profibus DP
• Profinet IO
• CC-Link
• Modbus/TCP
• Ethernet
• EtherCAT

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 5


Valve terminals type 32 MPA
Key features

Fieldbus connection via the CPX system


An integrated fieldbus node manages Valve terminals with fieldbus interfaces Versions
communication with a higher-order PLC. can be configured with up to • Profibus DP
This enables a space-saving pneumatic 16 manifold blocks. In conjunction with • ProfiNet
and electronic solution. MPA1 and 8 solenoid coils per manifold • Interbus
block, up to 128 solenoid coils can thus • DeviceNet connection
be actuated. An MPA2 with 4 solenoid • CANopen
coils per manifold block can actuate 64 • CC-Link
solenoid coils. • Ethernet/IP
• Front End Controller Remote
• Front End Controller
Remote I/O
• Modbus/TCP
• Profinet IO
• EtherCAT
• CPX terminal
 www.festo.com/catalog/cpx

Control block connection via the CPX system


Controllers integrated in the Festo valve Using the slave operation mode, these In the master operation mode, terminal
terminals enable the construction of valve terminals can be used for groups can be designed with many
stand-alone control units to IP65, intelligent pre-processing and are options and functions which can
without control cabinets. therefore ideal modules for designing autonomously control a medium-sized
decentralised intelligence. machine/system.
• CPX terminal
 www.festo.com/catalog/ cpx

6 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Peripherals overview

Modular pneumatic components


The modular design of the MPA The system consists of manifold blocks They contain the connection ducts for Each manifold block is connected to the
facilitates maximum flexibility right and valves. supplying compressed air to and next using three screws.
from the planning stage and offers The manifold blocks are screwed venting from the valve terminal as well Individual terminal sections can be
maximum ease of service in operation. together and thus form the support as the working lines for the pneumatic isolated and further manifold blocks
system for the valves. drives for each valve. inserted by loosening these screws. This
ensures that the valve terminal can be
rapidly and reliably extended.

Modular electrical peripherals


The manner in which the valves are Serial linking facilitates the following: • Separate voltage supply for valves • Option of CP interface
actuated differs according to whether • Transmission of switching • Flexible conversion without address • CPX-FEC as stand-alone controller
you are using a multi-pin terminal, information shifting with access via Ethernet and web
fieldbus terminal or individual valve. • High valve density • Transmission of status, parameter server
The MPA with CPX interface is based on • Compact design and diagnostic data
the internal bus system of the CPX and • Position-based diagnostics  Internet: cpx
uses this serial communication system
for all solenoid coils and a range of
electrical input and output functions.

MPA with electrical peripherals CPX Modularity with electrical peripherals CPX

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 7


Valve Terminals Type 32 MPA
Peripherals overview

Individual sub-base size 1


Ordering: Individual sub-bases can be equipped The electrical connection is established
• Using individual part numbers with any valve. using a standard 4-pin M8 plug
(EN 60947-5-2).

6 5

Designation Brief description  Page/Internet


1 Solenoid valve MPA1 69
2 Manual override Non-detenting/turning with detent, per solenoid coil –
3 Cover cap for manual override Conversion from detenting/non-detenting to non-detenting or covered 74
4 Sub-base For individual valve MPA1 71
5 Fittings and/or silencers M7 for working lines (2, 4) and work air supply/exhaust ports (1, 3, 5) 76
6 Fittings, silencers or blanking plugs M5 for pilot air supply/pilot exhaust air (12/14, 82/84) and pressure compensation 76
7 Electrical connection M8 4-pin –

8 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Peripherals overview

Individual sub-base size 2


Ordering: Individual sub-bases can be equipped The electrical connection is established An adjustable pressure regulator can be
• Using individual part numbers with any valve. using a standard 4-pin M8 plug installed between the manifold block
(EN 60947-5-2). and the valve in order to control the
force of the triggered actuator.

6 5

Designation Brief description  Page/Internet


1 Solenoid valve MPA2 69
2 Manual override Non-detenting/turning with detent, per solenoid coil –
3 Cover cap for manual override Conversion from detenting/non-detenting to non-detenting or covered 74
4 Sub-base For individual valve MPA2 71
5 Fittings and/or silencers Gx For working lines (2, 4) and work air supply/exhaust ports (1, 3, 5) 76
6 Fittings, silencers or blanking plugs M5 For pilot air supply/pilot exhaust air (12/14, 82/84) and pressure compensation 76
7 Electrical connection M8 4-pin –

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 9


Valve Terminals Type 32 MPA
Peripherals overview

Pneumatic components of the valve terminal – Multi-pin plug, AS-interface


The manifold blocks are either prepared • Double solenoid valve positions can • Single solenoid valve positions can
for: be equipped with any valve or a only be equipped with single solenoid
• 2 or 4 single solenoid valves blanking plate. valves.
• 2 or 4 double solenoid valves
depending on the size.

9 aJ

8
7

6
5

3
2
1

aA
aB

aC
aD

aE

aF

aG

aH

aI

aD

bJ

10 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Peripherals overview

Pneumatic components of the valve terminal – Multi-pin plug, AS-interface


Designation Brief description  Page/Internet
1 Electronics module – 73
2 Solenoid valve Size 1 69
3 Cover cap for manual override Conversion from detenting/non-detenting to non-detenting or covered –
4 Blanking plate For unused valve position (vacant position), size 1 74
5 Mounting Optional for valve terminal mounting (on supply plate) 71
6 Flat plate silencer – –
7 Exhaust plate For ducted exhaust air 74
8 Regulator plate Size 2 70
9 Solenoid valve Size 2 69
aJ Blanking plate For unused valve position (vacant position), size 2 74
aA H-rail mounting – 71
aB Right-hand end plate – 72
aC Separating seal For manifold block 74
aD Fittings For working lines 76
aE Inscription label – 76
aF Manifold block Size 2 71
aG Fittings For pneumatic supply plate 76
aH Supply plate – 74
aI Electrical manifold module For multi-pin plug connection, for AS-interface 73
bJ Manifold block Size 1 71

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 11


Valve Terminals Type 32 MPA
Peripherals overview

Pneumatic components of the valve terminal – CPI connection, fieldbus


The manifold blocks are either prepared • Double solenoid valve positions can • Single solenoid valve positions can
for: be equipped with any valve or a only be equipped with single solenoid
• 2 or 4 single solenoid valves blanking plate. valves.
• 2 or 4 double solenoid valves
depending on the size.

aC aD

aB

aA
aJ
9
8

7
6
5

4
3
aE
2 aF
1 aG
aH

aI

bJ

bA

bB
bC

bD

aH

bE

12 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Peripherals overview

Pneumatic components of the valve terminal – CPI connection, fieldbus


Designation Brief description  Page/Internet
1 Electronics module – 73
2 Solenoid valve Size 1 69
3 Cover cap for manual override Conversion from detenting/non-detenting to non-detenting or covered –
4 Blanking plate For unused valve position (vacant position), size 1 74
5 Electrical manifold module For fieldbus connection, for proportional pressure regulator 73
6 Mounting Optional for valve terminal mounting (on supply plate) 71
7 Flat plate silencer – –
8 Exhaust plate For ducted exhaust air 74
9 Mounting Optional for valve terminal mounting 71
(on the manifold block of the proportional pressure regulator)
aJ Electrical module For proportional pressure regulator 73
aA Proportional pressure regulator – 64
aB Regulator plate Size 2 70
aC Solenoid valve Size 2 69
aD Blanking plate For unused valve position (vacant position), size 2 74
aE H-rail mounting – 71
aF Right-hand end plate – 72
aG Separating seal For manifold block 74
aH Fittings For working lines 76
aI Manifold block Size 2 71
bJ Manifold block For proportional pressure regulator 71
bA Pressure sensor – 74
bB Fittings For pneumatic supply plate 76
bC Supply plate – 74
bD Electrical supply plate For auxiliary voltage supply for large valve terminals 73
bE Inscription label – 76

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 13


Valve Terminals Type 32 MPA
Peripherals overview

Valve terminal with multi-pin plug connection


Order code: MPA valve terminals with multi-pin plug The multi-pin plug connection is The cable can be selected when
• 32P-… for the pneumatic components connection can be expanded by up to designed as a removable 25-pin Sub-D ordering:
• 32E-… for the electrical components 24 solenoid coils. connection to IP65. • 2.5 m
• 5m
• 10 m
Each can be used for max. 8 or
24 valves.
3
2

6 7

Designation Brief description  Page/Internet


1 Inscription labels Large, for multi-pin plug connection –
2 Flat plate silencer For pneumatic interface –
3 Exhaust plate For ducted exhaust air 74
4 Multi-pin plug connection For self-assembly 75
5 Multi-pin plug connection With multi-pin cable 75
6 H-rail mounting – 71
7 Electrical interface For multi-pin plug 72

14 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Peripherals overview

Valve terminal with AS-interface connection


Order code: MPA valve terminals with AS-interface
• 32P-… for the pneumatic components connection can be expanded by up to
• 52E-… for the electrical components 8 solenoid coils.

Designation Brief description  Page/Internet


1 Manifold block – 72
2 Flat plate silencer For pneumatic interface –
3 Exhaust plate For ducted exhaust air 74
4 Cover – –
5 Electrical interface – 72

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 15


Valve Terminals Type 32 MPA
Peripherals overview

Valve terminal with CPI connection


Order code: MPA valve terminals with CPI connection
• 32P-… for the pneumatic components can be expanded by up to 32 solenoid
• 56E-… for the electrical coils.
components

Designation Brief description  Page/Internet


1 Flat plate silencer For pneumatic interface –
2 Exhaust plate For ducted exhaust air 74
3 Electrical interface – 72
4 Inscription label Large for CPI electrical interface –

16 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Peripherals overview

Valve terminal with fieldbus connection, control block (electrical peripherals CPX)
Order code: Valve terminals with fieldbus interfaces Each valve position can be equipped • Digital inputs/outputs
• 32P-… for the pneumatic components can be configured with up to with any valve or a blanking plate. The • Analogue inputs/outputs
• 50E-… for the electrical 16 manifold blocks. In conjunction with rules for CPX apply to the equipment • Parameterisation of inputs and
components MPA1 and 8 solenoid coils per manifold that can be used in combination with outputs
block, up to 128 solenoid coils can thus the electrical peripherals CPX. • Integrated multi-featured diagnostic
be equipped. An MPA2 with 4 solenoid In general: system
coils per manifold block can actuate 64 • Preventive maintenance concepts
solenoid coils.

5
4

Designation Brief description  Page/Internet


1 Flat plate silencer For pneumatic interface –
2 Exhaust plate For ducted exhaust air 74
3 CPX modules – –
4 Pneumatic interface For CPX modules 72
5 Inscription label Large, for pneumatic interface CPX –
6 H-rail mounting – 71

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 17


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Sub-base valve
MPA offers a comprehensive range of Sub-base valves can be quickly replaced Irrespective of the valve function there
valve functions. All valves are equipped since the tubing connectors remain on are sub-base valves with one solenoid
with piston spool and patented sealing the manifold block. coil (single solenoid) or with two
system which facilitates efficient This design is also particularly flat. solenoid coils (double solenoid or two
sealing, a broad pressure range and single solenoid valves in one housing).
long service life. To increase power they
have a pneumatic pilot control supplied
by pilot air.

Constructional design
Valve replacement Extension
The valves are attached to the metal replaced. The mechanical sturdiness of Blanking plates can be replaced by unchanged during this process.
manifold block using two screws, the manifold block guarantees excellent valves at a later date. The dimensions, The valve code (M, J, N, K, H, B, G, E, X,
which means that they can be easily long-term sealing. mounting points and existing W, D, I) is located on the front of the
pneumatic installations remain valve beneath the manual override.

Valve function
Code Circuit symbol
y Size Description
p
1 2
M 5/2-way valve, single solenoid
• Pneumatic spring return
  • Reversible
• Suitable for vacuum

J 5/2-way valve, double solenoid


• Reversible
  • Suitable for vacuum

N 2x 3/2-way valve, single solenoid


• Normally open
  • Pneumatic spring return
• Operating pressure > 3 bar

NS 2x 3/2-way valve, single solenoid


• Normally open
 – • Mechanical spring return
• Operating pressure –0.9 … +8 bar

K 2x 3/2-way valve, single solenoid


• Normally closed
  • Pneumatic spring return
• Operating pressure > 3 bar

KS 2x 3/2-way valve, single solenoid


• Normally closed
 – • Mechanical spring return
• Operating pressure –0.9 … +8 bar

18 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Valve function
Code Circuit symbol
y Size Description
p
1 2
H 2x 3/2-way valve, single solenoid
• Normally
– 1x closed
 
– 1x open
• Pneumatic spring return
• Operating pressure > 3 bar
HS 2x 3/2-way valve, single solenoid
• Normally
– 1x closed
 –
– 1x open
• Mechanical spring return
• Operating pressure –0.9 … +8 bar
B 5/3-way valve
• Mid-position pressurised1)
  • Mechanical spring return
• Reversible
• Suitable for vacuum
G 5/3-way valve
• Mid-position closed1)
  • Mechanical spring return
• Reversible
• Suitable for vacuum
E 5/3-way valve
• Mid-position exhausted1)
  • Mechanical spring return
• Reversible
• Suitable for vacuum
X 1x 3/2-way valve, single solenoid
• Normally closed
• External compressed air supply
  • Pneumatic spring return
• Reversible
Compressed air (–0.9 … +10 bar) supplied at working port 4 can be switched
with both internal and external pilot air supply.
W 1x 3/2-way valve, single solenoid
• Normally open
• External compressed air supply
  • Pneumatic spring return
• Reversible
Compressed air (–0.9 … +10 bar) supplied at working port 2 can be switched
with both internal and external pilot air supply.

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 19


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Valve function
Code Circuit symbol
y Size Description
p
1 2
D 2x 2/2-way valve
• Normally closed
  • Pneumatic spring return
• Operating pressure > 3 bar

DS 2x 2/2-way valve
• Normally closed
 – • Mechanical spring return
• Operating pressure –0.9 … +8 bar

I 2x 2/2-way valve
• 1x normally closed
• 1x normally closed, reversible
 
• Pneumatic spring return
• Operating pressure > 3 bar
• Vacuum at port 3/5 only

1) If neither solenoid coil is energised, the valve moves to its mid-position by means of spring force.
If both coils are energised at the same time, the valve remains in the previously assumed switching position.

Note

A filter must be placed upstream of valves in vacuum mode. This


prevents the ingress of foreign matter in the intake air into the valve
(e.g. when operating a suction cup).

20 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Vertical stacking
Additional function units can be added These functions are known as vertical functioning or control of an individual
to each valve position between the stacking, and enable special valve position.
sub-base and the valve.

Vertical stacking components


1 VMPA2 valve
2 Pressure regulator plate
1 3 Manifold block

Vertical stacking
Pressure regulator plate
An adjustable pressure regulator can be This pressure regulator maintains an Standard version:
installed between the manifold block essentially constant output pressure • For supply pressure up to 6 bar or up
and the valve in order to control the (secondary side) independent of to 10 bar
force of the triggered actuator. pressure fluctuations (primary side) and • Without pressure gauge (optional)
air consumption. • Regulator head with 3 positions
(locked, reference position, free
running)

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 21


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Vertical stacking
Mode of operation of the pressure regulator plate (P regulator) for port 1; code: PA, PF
This pressure regulator regulates the During venting, the exhaust flow in the
pressure upstream of the valve in valve is from duct 2 to duct 3 and from
duct 1. Ducts 2 and 4 thus have the duct 4 to duct 5.
same regulated pressure.

Advantages Application examples


• The pressure regulator is not affected • An equal working pressure is • A lower working pressure (e.g. 3 bar)
by venting, since the pressure is required at working ports 2 and 4. than the operating pressure present
regulated upstream of the valve. at the valve terminal (e.g. 8 bar) is
• The pressure regulator can always be required.
adjusted, since the pressure from the
valve terminal is always present.

Mode of operation of the pressure regulator plate (B regulator) for port 2; code: PC, PH
This pressure regulator regulates the
pressure in duct 2 after the pressure
medium flows through the valve. During
venting, the exhaust flow in the valve is
from duct 2 to duct 3 via the pressure
regulator.

Restrictions Application example


The pressure regulator can only be valve is switched to 2 and exhaust flow The pressure regulator makes it the operating pressure of the valve
adjusted in switched state (e.g. the occurs from 4 to 5). possible to reduce the pressure at port terminal.
2 of an individual valve, in contrast to

22 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Vertical stacking
Mode of operation of the pressure regulator plate (A regulator) for port 4; code: PB, PK
This pressure regulator regulates the
pressure in duct 4 after the pressure
medium flows through the valve. During
venting, the exhaust flow in the valve is
from duct 4 to duct 5 via the pressure
regulator.

Restrictions Application example


The pressure regulator can only be valve is switched to 4 and exhaust flow If different working pressures are
adjusted in switched state (e.g. the occurs from 2 to 3). required at ports 4 and 2. The pressure
present at port 2 is from duct 1.

Mode of operation of the pressure regulator plate (B regulator, reversible) for port 2, reversible; code: PL, PN
The reversible B regulator splits the During venting, the exhaust flow in the
supply air in duct 1 and regulates the valve is from duct 2 to duct 1 and it is
pressure upstream of the valve in duct 3 reversed into the manifold block via the
(the unregulated pressure from duct 1 is intermediate plate to duct 3.
in duct 5). The regulated air is then
supplied to duct 2. The valve is thus
operated in reversible mode.

Application examples
• When instead of the operating • When fast exhaust venting is Note
pressure of the valve terminal, a required.
Reversible pressure regulator plates
different pressure is required in duct • When the pressure regulator must
may only be combined with valves that
2. always be adjustable.
can be operated in reversible mode.

Advantages Restrictions
• Fast cycle times. • Operating pressure is always present • 2x 3/2-way valves (code N, K, H) are
• 50% higher exhaust flow rate, as air at the pressure regulator, as the not used, as pressure is present at
is not exhausted via the pressure pressure is regulated upstream of the ports 3 and 5.
regulator. The load on the pressure valve, i.e. the regulator can always be
regulator is also reduced. adjusted.
• No quick exhaust valves are required.

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 23


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Vertical stacking
Mode of operation of the pressure regulator plate (A regulator, reversible) for port 4, reversible; code: PK, PM
The reversible A regulator splits the During venting, the exhaust flow in the
working air in duct 1 and supplies the valve is from duct 4 to duct 1 and it is
pressure upstream of the valve into duct reversed into the manifold block via the
5 (the unregulated pressure from duct 1 intermediate plate to duct 5.
is in duct 3). The regulated air is then
supplied to duct 4. The valve is thus
operated in reversible mode.

Application examples
• When instead of the operating • When fast exhaust venting is Note
pressure of the valve terminal, a required.
Reversible pressure regulator plates
different pressure is required in duct • When the pressure regulator must
may only be combined with valves that
4. always be adjustable.
can be operated in reversible mode.

Advantages Restrictions
• Fast cycle times. • Operating pressure is always present • 2x 3/2-way valves (code N, K, H) are
• 50% higher exhaust flow rate, as air at the pressure regulator, as the not used, as pressure is present at
is not exhausted via the pressure pressure is regulated upstream of the ports 3 and 5.
regulator. The load on the pressure valve, i.e. the regulator can always be
regulator is also reduced. adjusted.
• No quick exhaust valves are required.

24 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Vertical stacking – Pressure regulator plate


Code Type
yp Size Supply pressure Description
p
1 2 6 bar 10 bar
Pressure regulator plate for port 1 (P regulator)
PA VMPA2-B8-R1C2-C-10 • Regulates the operating pressure in duct 1
–  –  upstream of the directional control valve

PF VMPA2-B8-R1C2-C-06
–   –

Pressure regulator plate for port 2 (B regulator)


PC VMPA2-B8-R2C2-C-10 • Regulates the operating pressure in duct 2
–  –  downstream of the directional control valve

PH VMPA2-B8-R2C2-C-06
–   –

Pressure regulator plate for port 4 (A regulator)


PB VMPA2-B8-R3C2-C-10 • Regulates the operating pressure in duct 4
–  –  downstream of the directional control valve

PG VMPA2-B8-R3C2-C-06
–   –

Pressure regulator plate for port 2, reversible (B regulator)


PL VMPA2-B8-R6C2-C-10 • Reversible pressure regulator
–  –  to port 2

PN VMPA2-B8-R6C2-C-06
–   –

Pressure regulator plate for port 4, reversible (A regulator)


PK VMPA2-B8-R7C2-C-10 • Reversible pressure regulator
–  –  to port 4

PM VMPA2-B8-R7C2-C-06
–   –

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 25


-V- New
VPPM

Valve Terminals Type 32 MPA


Key features – Pneumatic components

Proportional pressure regulator


The purpose of the proportional pressure until it reaches the setpoint
1 pressure regulator VPPM-6TA-… is to value. The proportional pressure
regulate a pressure proportionally to a regulator has an additional supply
2
specified setpoint value. To this end, connection to achieve the constant
an integrated pressure sensor records pressure supply required for high
the pressure at the working line and control quality.
compares this value against the The proportional pressure regulator
setpoint value. If there is a deviation can be configured via the PLC or
between the nominal and actual on-site via the handheld device
values, the valve regulates the output (CPX-MMI) from Festo.

1 Green power LED


2 Red error LED

Proportional pressure regulator


Code Graphical symbol Type Supply pressure 1 Pressure regulation range
2% full-scale linearity error
QA VPPM-6TA-L-1-F-0L2H 0 … 4 bar 0.02 … 2 bar

QB VPPM-6TA-L-1-F-0L6H 0 … 8 bar 0.06 … 6 bar

QC VPPM-6TA-L-1-F-0L10H 0 … 11 bar 0.1 … 10 bar

1% full-scale linearity error


QD VPPM-6TA-L-1-F-0L2H-S1 0 … 4 bar 0.02 … 2 bar

QE VPPM-6TA-L-1-F-0L6H-S1 0 … 8 bar 0.06 … 6 bar

QF VPPM-6TA-L-1-F-0L10H-S1 0 … 11 bar 0.1 … 10 bar

26 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Layout of a control circuit


Comparator (Valve output and all downstream
Closed-loop controller (integrated electronics) components)
Disturbance z
System deviation e (e.g. leakage)
(Valve piston)
Reference Controlled variable x
variable w Closed-loop Final control Controlled (pressure)
(setpoint control element element system
value)

Feedback signal r Measuring


device

Layout Method of operation


The figure shows a closed-loop control control element. The output of the This process runs continuously so or a change in load. The disturbance
circuit. The reference variable w final control element acts on the changes in the reference variable are variable z will also cause a system
initially acts on a comparator. The controlled system. The closed-loop always detected. However, a system deviation. An example of this is when
measuring device sends the value of control element thus attempts to deviation will also appear if the the pressure drops in the air supply.
the controlled variable x (actual value, compensate for the difference between reference variable is constant but the The disturbance variable z acts on the
e.g. 3 bar) to the comparator as a the reference variable w and the controlled variable changes. This controlled variable x unintentionally.
feedback signal r. The closed-loop controlled variable x by using the final happens when the flow through the In all cases, the regulator attempts to
control element detects the system control element. valve changes in response to a readjust the controlled variable x to
deviation e and actuates the final switching action, a cylinder movement the reference variable w.

Multi-sensor control (cascade control) of the VPPM

Working Diaphragm
Pilot solenoid Pilot control Working
Setpoint pressure pressure Main stage
coils stage volume
value regulator regulator

Sensor 1

Actual
Sensor 2
value

Cascade control Control precision


Unlike conventional direct-acting smaller sub-controlled circuits that Multi-sensor control significantly dynamic response in comparison with
regulators, with multi-sensor control are easier to control for the specific improves control precision and single-acting regulators.
several control circuits are nested task.
inside each other. The overall
controlled system is divided into

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 27


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Terms related to the proportional-pressure regulator


Hysteresis Linearity error
There is always a linear relationship A perfectly linear progression of the
within a certain tolerance between the control characteristic of the output
setpoint value entered and the pressure pressure is theoretical. The maximum
output. Nevertheless it makes a percentage deviation from this
difference whether the setpoint value is theoretical control characteristic is
entered as rising or falling. The referred to as the linearity error. The
difference between the maximum percentage value refers to the maximum
deviations is referred to as hysteresis. output pressure (full scale).

Response sensitivity Repetition accuracy (reproducibility)


The response sensitivity of the device The repetition accuracy is the margin
determines how sensitively one can within which the fluid output variables
change, i.e. adjust, a pressure. are scattered when the same electrical
3.61 bar The smallest setpoint value difference input signal coming from the same
that results in a change in the output direction is repeatedly adjusted. The
3.60 bar pressure is referred to as the response repetition accuracy is expressed as a
sensitivity. percentage of the maximum fluid output
In this case, 0.01 bar. signal.

Zero point suppression


In practice there exists the possibility of
residual voltage or residual current at
the setpoint input of the VPPM via the
setpoint generator.
x mbar Zero point suppression is used so that
the valve is reliably vented at a setpoint
value of zero.
1% linearity error
FS

28 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Blanking plate
Plate without valve function for Valves and blanking plates are attached
reserving valve positions on a valve to the manifold block using two screws.
terminal.

Valve function
Code Circuit symbol
y Size Description
p
1 2
L – For valve terminal only:
 
Blanking plate for vacant valve position

Compressed air supply and venting


Pneumatic interface pp
The valve terminal MPA can be supplied pp y to the valve terminal is
The main supply These vents are located on the
with air at one or more points. This located on the pneumatic interface, pneumatic interface as well as on the
ensures that the valve terminal will which links the electrical and the supply plates.
always have a sufficient supply of air pneumatic parts. Additional provision is In the case of ducted exhaust, at least
and that this air will be vented, even made for a number of supply plates. one additional supply plate is required
with large-scale expansions. Venting is either via integrated flat plate that then contains the exhaust port for
silencers or common lines for ducted the pilot air supply (port 82/84).
Supply plate exhaust.

Pilot air supply


The port for the main pneumatic supply Internal pilot air supply External pilot air supply
Note
is located on the pneumatic interface. Internal pilot air supply can be selected If the supply pressure is less than 3 bar
The ports differ for the following types of if the required working pressure is or greater than 8 bar, you must operate If a gradual pressure build-up in the
pilot air supply: between 3 and 8 bar. your MPA valve terminal with external system using a soft-start valve is
• Internal The pilot air supply is then branched pilot air supply. chosen, an external pilot air supply
• External from the compressed air supply 1 in the In this case the pilot air is additionally should be connected so that the
pneumatic interface using an internal supplied via port 12/14 on the control pressure applied during
connection. Port 12/14 is sealed with a pneumatic interface. switch-on is already very high.
blanking plug.

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 29


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Compressed air supply and pilot air supply


Code Graphical symbol Size Notes
Type of compressed air supply and pilot air supply
Pneumatic interface Supply plate 1 2
S Internal pilot air supply, flat plate silencer
• Pilot air supply is branched internally from port 1 in the pneumatic interface
• Exhaust port 3/5 and pilot exhaust port 82/84 via flat plate silencer
  • For operating pressure in the range 3 … 8 bar

T External pilot air supply, flat plate silencer


• Pilot air supply between 3 and 8 bar is connected to port 12/14
• Exhaust port 3/5 and pilot exhaust port 82/84 via flat plate silencer
  • For operating pressure in the range –0.9 … 10 bar (suitable for vacuum)

V Internal pilot air supply, ducted exhaust air


• Pilot air supply is branched internally from port 1 in the pneumatic interface
• Exhaust port 3/5: connection to pneumatic interface and supply plate
  • Pilot exhaust port 82/84: connection to supply plate only
• For operating pressure in the range 3 … 8 bar

X External pilot air supply, ducted exhaust air


• Pilot air supply (3 … 8 bar) is connected at port 12/14
• Exhaust port 3/5: connection to pneumatic interface and supply plate
  • Pilot exhaust port 82/84: connection to supply plate only
• For operating pressure in the range –0.9 … 10 bar (suitable for vacuum)

Pneumatic interface
Code Pneumatic interface design variants Size Notes
Graphical symbol Type 1 2
M VMPA-…-EPL-… • Used together with compressed air supply S, T, V, X
• The pilot exhaust air must be vented at least at one supply plate when using
V or X. In the case of multiple supply plates, the port 82/84 is open on the
  last supply plate ex-works.

30 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Supply plate
Additional supply plates can be used for Supply plates can be configured at any Supply plates contain the following If a separating seal (S, T or R) is selected
larger terminals or to create additional point upstream or downstream of ports: to the direct right or left of the supply
pressure zones. sub-bases. This applies to the following • Compressed air supply (1) plate, then the code letter V or W
interfaces: • Venting of the pilot air supply (82/84 identifies the position of the left-hand
If several valves are to be operated • MPA with CPX ) and pressure compensation or right-hand separating seal. The code
simultaneously at full flow rate, it is • MPA with multi-pin plug connection • Exhaust air (3/5) for the separating seal (S, T or R) is
recommended that a supply plate be • MPA with AS-interface connection Depending on your order, the exhaust placed in front of the code for the supply
positioned after every 8 valves (MPA1), • MPA with CPI connection ducts are either ducted or vented via the plate (V or W).
or 4 valves (MPA2). flat plate silencer.
MPA with ducted exhaust air
At least one supply plate via which the The supply plate is configured using the
exhaust port 82/84 is vented is code letter U if no directly adjoining
required with ducted exhaust air. separating seal is required.

Supply plate
Code1) Graphical
p symbol
y Type Size Notes
1 2
U VMPA1-…-SP… Supply plate without separating seal
(no R, S or T selected)

 

V VMPA1-…-SP… Supply plate with separating seal on left,


if R, S or T selected

 

W VMPA1-…-SP… Supply plate with separating seal on right,


if R, S or T selected

 

1) The supply plate is equipped with silencer or exhaust plate depending on the code for the air supply S, T, V, X.

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 31


Valve Terminals Type 32 MPA
Key features – Electrical components

Electrical supply plate


Additional electrical supply plates can MPA with CPX MPA with CPI connection
Note
be used for larger terminals. Electrical supply plates can be Electrical supply plates can be
This enables up to 64 valve configured at any point upstream or configured at any point upstream or Please note that only the electronics
positions/128 solenoid coils to be downstream of sub-bases. downstream of manifold blocks. modules with electrical isolation are
supplied. An electrical supply plate is required An electrical supply plate is required permitted to the right of the electrical
after 8 valve sub-bases. after 8 valve sub-bases. supply
pp y plate.
p
The electrical supply plate must not
Note
be installed directly to the left of a
Max. 24 of 32 MPA1 coils or 12 of 16 pneumatic supply plate
MPA2 coils can be switched on at the (type VMPA1-FB-SP...).
same time in the case of an MPA with
CPI connection.

Electrical supply plate


Code Graphical
p symbol
y Type Size Notes
1 2
L VMPA-FB-SP-V-SP Electrical supply plate with M18 plug connection, 3-pin
 

VMPA-FB-SP-7/8-V-5POL Electrical supply plate with 7/8” plug connection, 5-pin


 

VMPA-FB-SP-7/8-V-4POL Electrical supply plate with 7/8” plug connection, 4-pin


 

Pin allocation for power supply


Pin Allocation
Pin allocation for M18
2 24 V DC valves

3 0 V DC

4 FE

Pin allocation for 7/8”, 5-pin


1 0 V DC valves
2 n.c.
3 FE (leading)
4 n.c.
5 24 V DC valves

Pin allocation for 7/8”, 4-pin


A n.c.
B 24 V DC valves
C FE
D 0 V DC valves (leading)

32 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Creation of pressure zones and separation of exhaust air


MPA offers a number of options for Compressed air is supplied and vented Separating seals are integrated
creating pressure zones if different via a supply plate. ex-works as per your order.
working pressures are required. The position of the supply plates and Separating seals can be distinguished
A pressure zone is created by isolating separating seals can be freely selected through their coding, even when the
the internal supply ducts between the with the valve terminal MPA. valve terminal is assembled.
manifold blocks using an appropriate
separating seal or using a separator
that is permanently integrated in the
manifold block (code I or code III).

Note

The following must be taken into Different separating seals are required
consideration for subsequent for operating with ducted exhaust air
expansion or conversions: and operation with flat plate silencers.

Creating pressure zones


Code Separating seal for operating with flat plate Separating seal for operating with ducted Size Notes
silencer exhaust air
Pictorial examples Coding Pictorial examples Coding 1 2
– No duct separation

 

VMPA…-DPU VMPA…-DP
T Duct 1 separate

 

VMPA…-DPU-P VMPA…-DP-P
S Duct 1 and 3/5 separate

 

VMPA…-DPU-PRS VMPA…-DP-PRS
R Duct 3/5 separate

 

VMPA…-DPU-RS VMPA…-DP-RS

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 33


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Creating pressure zones


Code Manifold block with duct separation for operating with flat plate silencer or with ducted exhaust air Size Notes
Pictorial examples Coding 1 2
I Duct 1 separate

–  

III Duct 1 and 3/5 separate

–  

Note

The duct separation cannot be block:


subsequently removed and is • With size 1 between valves 2 and 3
integrated in the centre of the manifold • With size 2 between valves 1 and 2

34 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Examples: Compressed air supply and pilot air supply


Internal pilot air supply, flat plate silencer
Pneumatic air supply to the valve Optional separat-
terminal: code S ing seal
The diagram opposite shows an
example of the configuration and
connection of the air supply with
internal pilot air supply. Port 12/14 on
the pneumatic interface or the electrical
interface (multi-pin plug) as appropriate
is tightly sealed. Ports 3/5 and 82/84
are vented via the flat plate silencers.
Port 82/84 is tightly sealed. Separating
seals can be used optionally to create
pressure zones.

External pilot air supply, flat plate silencer


Pneumatic air supply to the valve Optional sepa-
terminal: code T rating seal
The diagram opposite shows an
example of the configuration and
connection of the compressed air supply
with external pilot air supply. Port
12/14 on the pneumatic interface or the
electrical interface (multi-pin plug) as
appropriate is equipped with a
threaded connector for this purpose.
Ports 3/5 and 82/84 are vented via the
flat plate silencers. Port 82/84 is tightly
sealed. Separating seals can be used
optionally to create pressure zones.

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 35


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Examples: Compressed air supply and pilot air supply


Internal pilot air supply, ducted exhaust air
Pneumatic air supply to the valve Optional sepa-
terminal: code V rating seal
The diagram opposite shows an
example of the configuration and
connection of the compressed air supply
with internal pilot air supply. Port
12/14 on the pneumatic interface or the
electrical interface (multi-pin plug) as
appropriate is tightly sealed. Exhaust
ports 3/5 and 82/84 are vented via the
appropriate connections. Separating
seals can be used optionally to create
pressure zones.

External pilot air supply, ducted exhaust air


Pneumatic supply to the valve terminal: Optional sepa-
code X rating seal
The diagram opposite shows an
example of the configuration and
connection of the compressed air supply
with external pilot air supply. Port
12/14 on the pneumatic interface or the
electrical interface (multi-pin plug) as
appropriate is equipped with a
threaded connector for this purpose.
Exhaust ports 3/5 and 82/84 are
vented via the appropriate connections.
Separating seals can be used optionally
to create pressure zones.

36 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Examples: Creating pressure zones


MPA with CPX terminal connection
MPA facilitates the creation of up to Zone 1 Zone 2 Zone 3
8 pressure zones. The diagram shows
an example of the configuration and
connection of three pressure zones
using separating seals – with external
pilot air supply.

Pilot air supply P1 P2 P3

MPA with multi-pin plug connection


This design facilitates the creation of up
to 12 pressure zones. The diagram Zone 1 Zone 2
shows an example of the configuration
and connection of the pressure zones –
with external pilot air supply.

Pilot air supply P1 P2

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 37


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Examples: Creating pressure zones


Manifold block with pressure zone separation in duct 1
Another way of creating pressure zones
is to use manifold blocks with pressure Zone 1 Zone 2
zone separation.
The diagram opposite shows the version
with pressure zone separation in duct 1.

Pilot air supply P1 P2

Manifold block with pressure zone separation in duct 1 and duct 3/5
The diagram opposite shows the version Zone 2
Zone 1
with pressure zone separation in duct 1
and duct 3/5.

Pilot air supply P1 P2

38 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Manifold block
MPA is based on a modular system supplying compressed air to and terminal sections can be isolated and
consisting of manifold blocks and venting from the valve terminal as well further manifold blocks inserted by
valves. The manifold blocks are screwed as the working lines for the pneumatic loosening these screws. This ensures
together and thus form the support drives for each valve. that the valve terminal can be rapidly
system for the valves. Each manifold block is connected to the and reliably extended.
They contain the connection ducts for next using three screws. Individual

Manifold block versions


Code Graphical
p symbol
y Type Size Number of valve ppositions Notes
1 2 (solenoid coils)
Manifold block for multi-pin plug/fieldbus connection
A, C* VMPA1-FB-AP-4-1 4 (8/4*) Working lines (2, 4) on the manifold block
• Connection sizes: MPA1:
M7 QS4,
M7, QS4 QS6
AI, CI* VMPA1-FB-AP-4-1-T1
 – • Code I: Separation in duct 1 in the
manifold block
AIII, CIII* VMPA1-FB-AP-4-1-S1 • Code III: Separation in duct 1 and duct
3/5 in the manifold block
B, D* VMPA2-FB-AP-2-1 2 (4/2*) Working lines (2, 4) on the manifold block
• Connection sizes MPA2:
Gx QS6,
Gx, QS6 QS8
BI, DI* VMPA2-FB-AP-2-1-TO
–  • Code I: Separation in duct 1 in the
manifold block
BIII, DIII* VMPA2-FB-AP-2-1-SO • Code III: Separation in duct 1 and duct
3/5 in the manifold block

Individual sub-base
– Without ATEX certification: 1 (2) • With working lines MPA1:
VMPA1-1-IC-AP-1** M7, QS4, QS6
VMPA1-1-IC-AP-S-1*** • With ports for supply air
 – ( 12/14)
(1, / ) andd exhaust
h air
With ATEX certification:
VMPA1-1-IC-AP-1-EX1** (3, 5, 82/84)
VMPA1-1-IC-AP-S-1-EX1*** • For internal or external pilot air supply

– Without ATEX certification: 1 (2) • With working lines MPA2:


VMPA2-IC-AP-1** Gx, QS6, QS8
VMPA2-IC-AP-S-1*** • With ports for supply air
–  (1 12/14) andd exhaust
(1, h t air i
With ATEX certification:
VMPA2-IC-AP-1-EX1** (3, 5, 82/84)
VMPA2-IC-AP-S-1-EX1*** • For internal or external pilot air supply

* Only possible with multi-pin plug connection


** Internal pilot air supply
*** External pilot air supply

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 39


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Pressure sensor
The pressure sensor indicates whether Alternatively the pressure in the
1
the applied pressure exceeds, adheres exhaust duct (3/5) and the process
4
2 to or falls below the setpoint value pressure (external) can be measured.
using three LEDs. An additional LED Pressure measurement in the exhaust
3 indicates common errors (limit duct is used for monitoring the
exceeded or fallen below). operating pressure during reversible
The limits for pressure monitoring are operation (supply to (3/5)).
set by means of parameter settings.
You can parameterise the pressure
sensor plate via the PLC or the
handheld device (CPXMMI) from Festo.

1 Red LED: Pressure exceeded


2 Green LED: Pressure adhered to
3 Red LED: Pressure fallen below
4 Red LED: Common error display

Pressure sensor versions


Code Graphical symbol Type Application
PE VMPA-FB-PS-1 Monitoring the operating pressure in duct 1

PF VMPA-FB-PS-3/5 Monitoring the pressure in exhaust ducts 3 and 5


(monitoring the venting performance or monitoring pressure in the case of reversible
valve terminals)
PG VMPA-FB-PS-P1 Monitoring an external process pressure

40 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Electrical interface versions


Code Graphical
p symbol
y Type Size Number of valve ppositions Notes
1 2 (solenoid coils)
Electronics module for multi-pin plug (MPM)
A, B, C, D VMPA1-MPM-EMM-8 4 (8) Each solenoid coil must be assigned to a
VMPA1-MPM-EMM-4 4 (4) specific pin of the multi-pin plug in order
 –
for the valve to be actuated. Regardless of
the blanking plates or valves used, valve
VMPA2-MPM-EMM-4 2 (4) positions occupy
VMPA2-MPM-EMM-2
– 
2 (2) • 1 address for actuation of 1 coil
• 2 addresses for actuation of 2 coils

Electronics module for fieldbus with standard diagnostics


A, B, H VMPA…-FB-EMS-… 4 (8) The electronics module contains the serial
VMPA…-FB-EMG-… communication system and facilitates:
• Transmission of switching information
 – • Actuation of up to 8 solenoid coils
• Position-based diagnostics
• Separate voltage supply for valves
• Transmission of status, parameter and
diagnostic data
2 (4)
There are different versions:
• Not electrically isolated
(VMPA…-FB-EMS-…)
–  • Electrically isolated
(VMPA…-FB-EMG-…)
Diagnostic function:
• Error: Load voltage of the valves

Electronics module for fieldbus with extended diagnostic function


A, B, H VMPA…-FB-EMS-…-D2 4 (8) The electronics module with extended
VMPA…-FB-EMG-…-D2 diagnostic function contains the same
 – functions as the electronics module with
standard diagnostics. The diagnostic
function,
u ct o , however,
oweve , has been eextended:
as bee te ded:
2 (4) • Error: Load voltage of the valves
• Error: Wire break (open load)
–  • Error: Short circuit in load voltage of
valves
• Message: Condition monitoring

Note

• Multi-pin plug with modular linking • Positive or negative switching • Double solenoid valves cannot be • Single solenoid valves can be
• Manifold blocks MPA1 and MPA2 actuation is possible (mixed mounted on single solenoid mounted on double solenoid
can be combined as required operation is not permitted) electronics modules electronics modules

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 41


Valve Terminals Type 32 MPA
Key features – Pneumatic components

Ports for supply and exhaust


Code Port Designation Code L Code K Code D
Large plug Small plug Thread for supply
connector connector
S Internal pilot air supply, silencer
1 Supply air/ Push-in fitting QS-G¼-10-I QS-G¼-8-I G¼
vacuum supply
3/5 Exhaust air Flat plate silencer – – –
12/14 Pilot air supply – – – –
82/84 Pilot exhaust air Flat plate silencer – – –
Pressure compensation Vents into the atmosphere via silencer

T External pilot air supply, silencer


1 Supply air/ Push-in fitting QS-G¼-10-I QS-G¼-8-I G¼
vacuum supply
3/5 Exhaust air Flat plate silencer – – –
12/14 Pilot air supply Push-in fitting QSM-M7-6-I QSM-M7-6-I M7
82/84 Pilot exhaust air Flat plate silencer – – –
Pressure compensation Vents into the atmosphere via silencer

V Internal pilot air supply, ducted exhaust air


1 Supply air/ Push-in fitting QS-G¼-10-I QS-G¼-8-I G¼
vacuum supply
3/5 Exhaust air Push-in fitting QS-10 QS-10 QS-10
12/14 Pilot air supply – – – –
82/84 Pilot exhaust air Push-in fitting QSM-M7-6-I QSM-M7-6-I M7
Pressure compensation Vents into duct 82/84

X External pilot air supply, ducted exhaust air


1 Supply air/ Push-in fitting QS-G¼-10-I QS-G¼-8-I G¼
vacuum supply
3/5 Exhaust air Push-in fitting QS-10 QS-10 QS-10
12/14 Pilot air supply Push-in fitting QSM-M7-6-I QSM-M7-6-I M7
82/84 Pilot exhaust air Push-in fitting QSM-M7-6-I QSM-M7-6-I M7
Pressure compensation Vents into duct 82/84

42 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Assembly

Valve terminal assembly


Sturdy terminal assembly thanks to: Note prevent damage to the valve
• Four through-holes for wall • Additional mounting brackets When wall-mounting MPA valve terminal. The mounting brackets can
mounting • H-rail mounting terminals with more than 4 manifold be mounted on the pneumatic supply
blocks, use additional mounting plates.
brackets of the type VMPA-BG-RW to

Wall mounting – Multi-pin plug connection, AS-interface and CPI connection Wall mounting – Fieldbus connection

The MPA valve terminal is screwed onto There are also optional mounting The MPA valve terminal is screwed onto The pneumatic interface also provides
the mounting surface using four M4 or brackets available. the mounting surface using six M4 or further mounting holes as well as
M6 screws. The mounting holes are on M6 screws. The mounting holes are on optional mounting brackets.
the pneumatic interface and on the the left-hand end plate (CPX) and on
right-hand end plate. the right-hand end plate MPA.

H-rail mounting
The MPA valve terminal is attached to For H-rail mounting of the valve
the H-rail (see arrow A). terminal you will need the following
A The terminal is then swivelled around MPA mounting kit:
the H-rail and secured in place with • With multi-pin plug:
the clamping component (see ar- CPA-BG-NRH
row B). • With fieldbus:
CPX-CPA-BG-NRH
This enables mounting of the valve
terminal on a H-rail to EN 60715.
B

Individual valve assembly


2 1 Horizontal mounting holes The individual sub-base is designed
2 Vertical mounting holes for wall mounting or for integration
into a system or machine. It can be
mounted horizontally or vertically.

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 43


Valve Terminals Type 32 MPA
Key features – Display and operation

Display and operation


Each solenoid coil is allocated an LED Manual override status can also be locked by turning to prevent it from being locked. The
that indicates its signal status. The manual override (MO) enables the the manual override (code R or as manual override can then only be
• Indicator 12 shows the switching valve to be actuated when not accessory). activated by pushing it.
status of the coil for output 2 electrically activated or energised. Alternatives: • A cover (code V) can be fitted over
• Indicator 14 shows the switching The valve is actuated by pushing the • A cover (code N or as accessory) can the manual override to prevent it
status of the coil for output 4 manual override. The set switching be fitted over the manual override from being accidentally activated.

Pneumatic connection and control elements


1 2 3 1 Flat plate silencer for exhaust port
3/5
2 Manual override (for each pilot
solenoid coil, non-detenting or
4 non-detenting/detenting)
3 Adjusting knob of optional
pressure regulator plate
4 Inscription label holder for
manifold block
5 Working
k lines 2 andd 4, for eachh
valve position Note
6 Supply port 1 A manually actuated valve (manual
7 Pressure gauge (optional) override) cannot be reset electrically.
8 Ports 12 and 14 for supplying the Conversely, an electrically actuated
external pilot air valve cannot be reset using the
8 7 6 5 mechanical manual override.

Electrical connection and display components on the AS-interface


6

5
4

3
1 M12 socket for AS-interface bus
and additional supply (AS-i Out)
2 M12 plug for AS-interface bus and
additional supply (AS-i In)
3 Earth terminal
4 Status LEDs for inputs
1
5 Status LEDs for AS-interface
2 6 Diagnostic LEDs for valves

44 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Display and operation

Manual override (MO)


MO with automatic return (non-detenting) MO set via turning (detenting)
1 Press in the stem of the MO with a 1 Press in the stem of the MO with a
1 2 1 2
pin or screwdriver. pin or screwdriver until the valve
Pilot valve switches and actuates switches and then turn the stem
the main valve. clockwise by 90° until the stop is
2 Remove the pin or screwdriver. reached.
Spring force pushes the stem of the Valve remains actuated.
MO back. 2 Turn the stem anti-clockwise by
Pilot valve returns to its initial 90° until the stop is reached and
position and so too the single then remove the pin or screwdriver.
solenoid main valve (not with Spring force pushes the stem of the
double solenoid valve code J). MO back.
Valve returns to its initial position
(not with double solenoid valve
code J).

Inscription system
Inscription field An inscription label holder Large inscription labels can be
approx. 20 x 45 mm VMPA1-ST-1-4 (Part No. 533 362, applied to the pneumatic interface as
code T in the order code) or an alternative or complement to the
VMPA1-ST-2-4 (Part No. 544 384, for smaller labels.
holding IBS-6x10 inscription labels) The following inscription labels can be
can be mounted on each manifold used as spares:
block with a width of 42 mm for • Inscription label MPA
labelling the valves. (20 x 45 mm): Part No. 663 010

VMPA1-ST-1-4
approx. 38 x 9 mm

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 45


Valve Terminals Type 32 MPA
Key features – Electrical components

Electrical power as a result of current reduction


Each MPA solenoid coil is protected with MPA valves are supplied with operating
a spark arresting protective circuit as voltage in the range 18 … 30 V
Power management well as against polarity reversal. (24 V +/–25%). This high tolerance is
All valve types are additionally made possible through integrated
equipped with integrated current control electronics and offers additional
reduction. security, e.g. if the operating voltage
drops.

Individual valve
Valves can also be used on individual • Detachable electronics module with • Electrical M8 connection, 4-pin with
sub-bases for actuators further away integrated holding current reduction screw connection
from the valve terminal.

Electrical multi-pin plug connection


The following multi-pin plug pins up to 24 are left free. Pin 25 is of valve positions is 24, this means
Note
connection is offered for the valve reserved for the neutral conductor. that 24 valves can be addressed with
terminal MPA: The valves are switched by means of one solenoid coil. If a single solenoid valve is assembled
• Sub-D multi-pin plug connection positive or negative logic (PNP or With 12 or less valve positions, on a double solenoid valve position,
(25-pin) NPN). Mixed operation is not 2 solenoid coils per valve can be the second address is also occupied
permitted.
pe tted. addressed.
add essed. With
t 12 oor more
o e valve and cannot be used.
Pins 1 … 24 are used for addresses Each pin on the multi-pin plug can positions, the number of available
1 … 24 in order. actuate exactly one solenoid coil. If valve positions for valves with two
If fewer than 24 addresses are used the maximum configurable number solenoid coils decreases.
for the valve terminal, the remaining

Guidelines on addressing for valves/solenoid coils


• The maximum possible number of – Manifold block MPA1 for 4 double • The numbering of the addresses goes • If single solenoid valves are mounted
addresses with a multi-pin plug solenoid valves: 8 from left to right in ascending on manifold blocks for double
connection is 24. – Manifold block MPA2 for 2 single consecutive order. The following solenoid valves, the address of
• Each manifold block/electronics solenoid valves: 2 applies to the individual valve coil 12 and the assigned pin will
module occupies a defined number of – Manifold block MPA2 for 2 double positions: address x for coil 14 and remain unused.
addresses/pins: solenoid valves: 4 address x+1 for coil 12.
– Manifold block MPA1 for 4 single
solenoid valves: 4

46 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Electrical components

AS-interface® fieldbus connection


The AS-interface facilitates the spatial terminal type 32 can be used to terminal contains the LEDs that
Note
distribution of individual components control up to 8 solenoid coils. indicate the operating status and the
or small component groups. The electrical connection of the valve protective circuit for the valves. For further information see
The AS-interface connection of valve  Internet: as-interface

CPI fieldbus connection


All CP valve terminals and CP modules one CPV valve terminal and one to supports a maximum of 4 installation
Note
are connected using a ready-to-install three CP input modules, make up an strings that can be connected to a CP
CP cable, and are attached to the CP installation string that ends at the CP fieldbus node. For further information see
interface. Four modules, for example interface. The installation system  Internet: cpi

CPX fieldbus connection


All functions and features of the • The valves and electrical outputs • The valves are supplied and
Note
electrical peripherals CPX are are supplied via the operating disconnected separately via a
supported in connection with the CPX voltage connection CPX separate valve connection on the For further information see
interface. This means: CPX (code V)  Internet: cpx

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 47


Valve Terminals Type 32 MPA
Key features – Electrical components

Pin allocation – Sub-D socket, cable


Pin Address/coil Wire colour2) Pin Address/coil Wire colour2)
1 0 WH 17 16 WH PK
2 1 GN 18 17 PK BN
3 2 YE 19 18 WH BU
4 3 GY 20 19 BN BU
5 4 PK 21 20 WH RD
6 5 BU 22 21 BN RD
7 6 RD 23 22 WH BK
8 7 VT 24 23 BN
9 8 GY PK 25 0 V1) BK
10 9 RD BU
11 10 WH GN
Note
12 11 BN GN
13 12 WH YE The drawingg shows a view on the Sub-D socket on
14 13 YE BN the multi-pin
p cable VMPA-KMS1-….
15 14 WH GY
16 15 GY BN

1) 0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted.
2) To IEC 757.

Dimensions Download CAD Data  www.festo.com/us/cad


Connecting cable
1 Cable conduit fitting with clamping The wire colours refer to the following
range 6 … 12 mm pre-assembled multi-pin cables from
Festo:
• VMPA-KMS1-8-… Valve terminal for
up to 4 valve positions (8 coils)
• VMPA-KMS1-24-… Valve terminal with
8 … 24 valve positions

Sheath Core x mm2 D Length Part No. Type


yp
[mm] [m]
PVC 10 x 0.34
3 6.9
9 2.5 533195 VMPA-KMS1-8-2.5
5 533196 VMPA-KMS1-8-5
10 533197 VMPA-KMS1-8-10
PUR 10 x 0.25
5 8.3
3 2.5 533504 VMPA-KMS2-8-2.5-PUR
5 533505 VMPA-KMS2-8-5-PUR
10 533506 VMPA-KMS2-8-10-PUR
PVC 25
5 x 0.34
3 11.4 2.5 533192 VMPA-KMS1-24-2.5
5 533193 VMPA-KMS1-24-5
10 533194 VMPA-KMS1-24-10
PUR 25
5 x 0.25
5 11.2 2.5 533501 VMPA-KMS2-24-2.5-PUR
5 533502 VMPA-KMS2-24-5-PUR
10 533503 VMPA-KMS2-24-10-PUR
Cover for self-assembly Cover for self-assembly 533198 VMPA-KMS-H

48 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Key features – Electrical components

Electrical connection – Individual valve interface

Pin3 Pin1 Pin allocation on individual valve to


VDMA 24571
With positive logic: With negative logic:
Pin1 – Not allocated Pin1 – Not allocated
Pin2 – VO for coil 12 Pin2 – 0 V for coil 12
Pin3 – 0 V for coils 12 and 14 Pin3 – VO for coils 12 and 14
Pin4 Pin2
Pin4 – VO for coil 14 Pin4 – 0 V for coil 14

Tightening torque for M8 plug


0.25 … 0.5 Nm (manual torque)

Connector plug M8 x 1, male, 4-pin to


EN 60 947-5-2

Connecting cable

Plugg socket with cable Straight


g socket 2.5 158 960 SIM-M8-4GD-2,5-PU
5 158 961 SIM-M8-4GD-5-PU
Angled
g socket 2.5 158 962 SIM-M8-4WD-2,5-PU
5 158 963 SIM-M8-4WD-5-PU
Straight
g socket 2.5 541 342 NEBU-M8G4-K-2.5-LE4
5 541 343 NEBU-M8G4-K-5-LE4
Angled
g socket 2.5 541 344 NEBU-M8W4-K-2.5-LE4
5 541 345 NEBU-M8W4-K-5-LE4

Note

Additional variants can be configured


and ordered via the NEBU modular
product system.
 Internet: nebu

Instructions for use


Equipment Bio-oils Mineral oils
Operate your equipment with Unsuitable additional oil and an When using bio-oils (oils that are based When using mineral oils (e.g. HLP oils to
unlubricated compressed air if possible. excessive oil content in the compressed upon synthetic or native ester, DIN 51524, parts 1 to 3) or similar oils
Festo valves and cylinders are designed air reduce the service life of the valve e.g. rapeseed oil methyl ester), the based on poly-alpha-olefins (PAO), the
so that, if used as designated, they will terminal. maximum residual oil content of maximum residual oil content of
not require additional lubrication and Use Festo special oil OFSW-32 or the 0.1 mg/m3 must not be exceeded 5 mg/m3 must not be exceeded (see
will still achieve a long service life. alternatives listed in the Festo catalogue (see ISO 8573-1 Class 2). ISO 8573-1 Class 4).
The quality of compressed air (as specified in DIN 51524 HLP32; A higher residual oil content
downstream from the compressor must basic oil viscosity 32 CST at 40 °C). irrespective of the compressor oil
correspond to that of unlubricated cannot be permitted, as the basic
compressed air. If possible, do not lubricant would be flushed out over
operate all of your equipment with time.
lubricated compressed air. The
lubricators should, where possible,
always be installed directly upstream of
the actuator used.

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 49


Valve Terminals Type 32 MPA
Technical data

Flow rate
MPA1: Up to 360 l/min
MPA2: Up to 700 l/min

Valve width
MPA1: 10 mm
MPA2: 21 mm

Voltage
24 V DC

General technical data


MPA1 MPA2
Constructional design Electromagnetically actuated piston spool valve
Lubrication Lubricated for life, PWIS-free (free of paint-wetting impairment substances)
Type
yp of mountingg Wall mounting
On H-rail to EN 60715
Mounting position Any
Manual override Non-detenting/turning with detent/covered
Width [mm] 10.5 21
Pneumatic connections
Pneumatic connection Via manifold block or individual connection
Supply port 1 G¼ (M7 with individual sub-base)
Exhaust port 3/5 QS-10 (M7 with individual sub-base)
Workingg lines 2/4
/ Depending on the connection type selected
• M7 • Gx
• QS4 • QS6
• QS6 • QS8
Pilot air port 12/14 M7 (M5 with individual sub-base)
Pilot exhaust port 82/84 M7 (M5 with individual sub-base)
Pressure compensation port With ducted exhaust air: via port 82/84 (M5 with individual sub-base)
With flat plate silencer: venting to atmosphere

50 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data

Operating and environmental conditions


Valve function order code M J N K H B G E X W D I NS KS HS DS
Operating medium Filtered compressed air, lubricated or unlubricated, inert gases  49
Grade of filtration [μm] 40
Operating pressure [bar] –0.9 … +10 3 … 10 –0.9 … +10 3 … 10 –0.9 … +8
Operating pressure for valve terminal with [bar] 3…8
internal pilot air supply
Pilot pressure [bar] 3…8
Ambient temperature [°C] –5 … +50
Temperature of medium [°C] –5 … +50
Storage temperature1) [°C] –20 … +40
Relative air humidity at 40 °C [%] 90
Corrosion resistance class CRC2) 1

1) Long-term storage
2) Corrosion resistance class 1 as per Festo standard 940 070
Components requiring low corrosion resistance. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers.

Pilot pressure p2 as a function of working pressure p1 with external pilot air supply
for valves with code M, J, B, G, E, X
p2 [bar]

1 Operating range for valves with


p1 [bar] external pilot air supply

for valves with code N, K, H, D, I


p2 [bar]

1 Operating range for valves with


p1 [bar] external pilot air supply

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 51


Valve Terminals Type 32 MPA
Technical data

Pilot pressure p2 as a function of working pressure p1 for valves with mechanical spring return (MPA1)
for valves with code NS, KS, HS, DS

Flow rate qn as a function of output pressure p2 with pressure regulator plates (P regulator plate) for port 1
Width 21 mm
Supply pressure 10 bar,
set regulator pressure 6 bar

Flow rate qn as a function of output pressure p2 with pressure regulator plates (B regulator plates) for port 2
Width 21 mm
Supply pressure 10 bar,
set regulator pressure 6 bar

52 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data

Flow rate qn as a function of output pressure p2 with pressure regulator plates (A regulator plates) for ports 4
Width 21 mm
Supply pressure 10 bar,
set regulator pressure 6 bar

Flow rate qn as a function of output pressure p2 with pressure regulator plates (B regulator plates, rev.) for ports 3, reversible
Width 21 mm
Supply pressure 10 bar,
set regulator pressure 6 bar

Flow rate qn as a function of output pressure p2 with pressure regulator plates (A regulator plates, rev.) for ports 5, reversible
Width 21 mm
Supply pressure 10 bar,
set regulator pressure 6 bar

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 53


Valve Terminals Type 32 MPA
Technical data

Certifications1)
Type MPA-MPM-VI MPA-FB-VI Valve on individual sub-base
(VI with multi-pin plug interface) (VI with fieldbus interface)
Part number 539 105 530 411  68
ATEX specification II 3 GD EEx nA II T95° C X IP54 – –
ATEX ambient temperature [°C] –5 ≤ Ta ≤ +50 – –
Certification cULus recognized (OL) cULus recognized (OL) cULus recognized (OL)

1) Interface versions not listed (e.g. CPI interface or AS-interface) do not have any of the listed certifications

Nominal flow rate [l/min]1)


Code Valve function Without fitting With fitting2)
from port from port from port from port
1 to 2, or 1 to 4 2 to 3/5, or 4 to 3/5 1 to 2, or 1 to 4 2 to 3/5, or 4 to 3/5
MPA1
M 5/2-way valve, single solenoid 360 360 360 360
J 5/2-way valve, double solenoid 360 360 360 360
N 2x 3/2-way valve, normally open 300 300 300 300
NS 2x 3/2-way valve, normally open, mechanical spring return 300 300 300 300
K 2x 3/2-way valve, normally closed 230 310 230 310
KS 2x 3/2-way valve, normally closed, mechanical spring return 230 310 230 310
H 2x 3/2-way valve, 1x normally open, 1x normally closed 280 305 280 305
HS 2x 3/2-way valve, 1x normally open, 1x normally closed, mechanical 300 305 300 305
spring return
B 5/3-way valve, mid-position pressurised 300 (195)3) 270 300 (195)3) 270
G 5/3-way valve, mid-position closed 320 320 320 320
E 5/3-way valve, mid-position exhausted 240 240 (180)3) 240 240 (180)3)
X 1x 3/2-way valve 255 295 255 295
W 1x 3/2-way valve 255 295 255 295
D 2x 2/2-way valve 230 230 230 230
DS 2x 2/2-way valve, mechanical spring return 230 – 230 –
I 2x 2/2-way valve 260 260 230 260
MPA2
M 5/2-way valve, single solenoid 700 700 660 670
J 5/2-way valve, double solenoid 700 700 660 670
N 2x 3/2-way valve, normally open 560 490 550 480
K 2x 3/2-way valve, normally closed 500 560 500 540
H 2x 3/2-way valve, 1x normally open, 1x normally closed 500 490 500 480
B 5/3-way valve, mid-position pressurised 520 650 (350)3) 510 600 (350)3)
G 5/3-way valve, mid-position closed 630 630 600 610
E 5/3-way valve, mid-position exhausted 610 440 (350)3) 590 420 (350)3)
X 1x 3/2-way valve 500 590 470 560
W 1x 3/2-way valve 500 590 470 560
D 2x 2/2-way valve 680 – 650 –
I 2x 2/2-way valve 680 500 650 500

1) Values also apply to individual sub-bases


2) Flow rates measured on manifold block with fitting QS-M7-6-l for MPA1 and QS-Gx-8-l for MPA2
3) Value for mid-position

54 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data

Valve switching times [ms]


Valve function order code M J N K H B G E X W D I NS KS HS DS
MPA1
Switchingg times on 10 10 10 10 10 10 10 10 10 10 10 10 14 14 14 14
off 20 – 20 20 20 35 35 35 20 20 20 20 16 16 16 16
changeo – 15 – – – – – – – – – – – – – –
ver
MPA2
Switchingg times on 15 9 8 8 8 11 10 11 13 13 7 7 – – – –
off 28 – 28 28 28 46 40 47 22 22 25 25 – – – –
changeo – 22 – – – 23 21 23 – – – – – – – –
ver

Electrical data
MPA with electronics module VMPA…-FB… (CPX terminal, CPI interface)
Voltage supply for electronics (VEL/SEN)
Nominal voltage [V DC] 24
Operating voltage range [V DC] 18 … 30
Intrinsic current consumption per electronics module [mA] Typically 8 (internal electronics, all outputs 0 signal)
at 24 V
Load voltage supply for valves (Vval)
Nominal voltage [V DC] 24
Operating voltage range [V DC] 18 … 30
Intrinsic current consumption at 24 V (internal
electronics without valves) per electronics module
VMPA1-FB-EMG-8, VMPA2-FB-EMG-4 [mA] Typically 23 mA
VMPA1-FB-EMS-8, VMPA2-FB-EMS-4 [mA] Typically 3 mA
Diagnostic message on undervoltage VOFF Load voltage [V] 17.5 … 16
outside function range
Protection class to EN 60529 IP65 (for all types of signal transmission in assembled state)
Maximum current consumption per solenoid coil at nominal MPA1 MPA2
voltage
Nominal pick-up current [mA] 58 99
Nominal current following current reduction [mA] 9 18
Time until current reduction [ms] 24 24
Calculation example
Current consumption with two solenoid coils MPA2 [mA] I
El/SEN = 20
switched in parallel and one electronics module
without electrical isolation
Nominal pick-up current [mA] I
VAL = 8 (intrinsic current consumption of electronics module) + 2 x 99 (MPA2) = 206
Nominal current with current reduction [mA] I
VAL = 8 (intrinsic current consumption of electronics module) + 2 x 18 (MPA2) = 44

MPA with electronics module VMPA…-MPM (AS-interface, multi-pin plug)


Power supply
Nominal voltage [V DC] 24
Operating voltage range [V DC] 18 … 30
Residual ripple [Vss] 4
Current consumption at Sub-D multi-pin plug connection per MPA1 MPA2
solenoid coil at nominal voltage
Nominal pick-up current [mA] 80 100
Nominal current with current reduction [mA] 25 20
Time until current reduction [ms] 25 50

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 55


Valve Terminals Type 32 MPA
Technical data

Data on vibration and shock in accordance with DIN/EC68


MPA1 MPA2
Vibration1) Tested to DIN/IEC68 / EN 60068 Parts 2 … 6
With horizontal H-rail mounting: Severity level 1
With wall mounting: 2)
Shock1) Tested to DIN/IEC68 / EN 60068 Parts 2 … 27
With horizontal H-rail mounting: Severity level 1
With wall mounting: Severity level 1 … 22)
Continuous shock Tested to DIN/IEC68 / EN 60068 Parts 2 … 29
With wall and H-rail mounting: Severity level 1

1) See the CPX System manual for information on vibrations and shock for the CPX terminal.
2) Valve terminal MPA with MPM connection and more than 5 manifold blocks: Severity level 1
Valve terminal MPA with CPX terminal or MPM connection and
up to 5 manifold blocks without additional attachments: Severity level 2
6 or more manifold blocks without additional mounting (wall bracket) after 2 to max. 4 manifold blocks: Severity level 2

Test conditions
Severity level Vibration Shock Continuous shock
1 0.15 mm travel at 10 … 58 Hz, ±15 g at 11 ms duration, ±15 g at 6 ms duration,
2 g acceleration at 58 … 150 Hz 5 shocks per direction 1000 shocks per direction
2 0.35 mm travel at 10 … 60 Hz, ±30 g at 11 ms duration, –
5 g acceleration at 60 … 150 Hz 5 shocks per direction
Continuous shock resistance To DIN/IEC 68/EN 60068, Parts 2-29: +/–15 g at 6 ms, 1000 cycles

56 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data

Materials
Manifold block Die-cast aluminium
Valve Die-cast aluminium
Seals NBR, elastomer
Supply plate Die-cast aluminium
Right-hand end plate Die-cast aluminium
Left-hand pneumatic interface Die-cast aluminium, polyamide
Exhaust plate Polyamide
Flat plate silencer Polyethylene
Electrical supply plate Housing: die-cast aluminium
Cover: reinforced polyamide
Electronics module Polycarbonate
Electrical manifold module Bronze/polybutylene terephthalate
Regulator plate Control section, housing: polyamide; seals: nitrile rubber

Product weight
Approx. weight [g] MPA1 MPA2
Manifold block basic weight1) 400 (4 valve positions) 400 (2 valve positions)
Manifold block1) 185
Individual sub-base 45
Per valve M, X, W 49 100
Per valve J, N, K, H, B, G, E, D 56 100
Per valve KS, NS, HS, DS 56 –
Per vacant position L 24 44
Right-hand end plate 55
Left-hand pneumatic interface1)
• With flat plate silencer 315
• With ducted exhaust air 324
Supply plate1)
• With flat plate silencer 111
• With ducted exhaust air 120
Electrical supply plate 200
Regulator plate (MPA2) 180
QSM-M5-3-I 3
QSM-M5-4-I 4
QSM-M5-6-I 5
QSM-M7-4-I 6
QSM-M7-6-I 5
QS-Gx-6-l 22
QS-Gx-8-l 13
QS-G¼-8-I 22
QS-G¼-10-I 23

1) With sheet metal seal, inscription label holder, screws

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 57


Valve Terminals Type 32 MPA
Technical data

Dimensions Download CAD Data  www.festo.com/us/cad


MPA1 valve on individual sub-base

1 Solenoid valve
2 Individual sub-base
3 4x mounting holes for screw M3
4 Earthing screw

MPA2 valve on individual sub-base

58 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


1 Solenoid valve
2 Individual sub-base
3 2x mounting holes for screw M3
4 Earthing screw
5 2x mounting holes for screw M5

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 59


Valve Terminals Type 32 MPA
Technical data

Dimensions Download CAD Data  www.festo.com/us/cad


Valve terminal with multi-pin plug connection

1 Solenoid valve MPA1 5 Working lines 9 Multi-pin plug connection n Number of manifold blocks in a
2 Solenoid valve MPA2 6 H-rail aJ Earthing screw grid of 4 MPA1 or 2 MPA2 valves
3 Manual override 7 H-rail mounting aA Electrical supply plate
4 Supply/exhaust ports 8 Mounting holes

60 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data

Dimensions Download CAD Data  www.festo.com/us/cad


Valve terminal with AS-interface connection

1 Solenoid valve MPA1 5 Working lines 9 Manifold block n Number of manifold blocks in a
2 Solenoid valve MPA2 6 H-rail aJ Earthing screw grid of 4 MPA1 or 2 MPA2 valves
3 Manual override 7 H-rail mounting aA Plug M12
4 Supply/exhaust ports 8 Mounting holes

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 61


Valve Terminals Type 32 MPA
Technical data

Dimensions Download CAD Data  www.festo.com/us/cad


Valve terminal with CPI connection

1 Solenoid valve MPA1 7 H-rail mounting aB Connecting cable with angled n Number of manifold blocks in a
2 Solenoid valve MPA2 8 Mounting holes plug grid of 4 MPA1 or 2 MPA2 valves
3 Manual override 9 Manifold block aC Connecting cable with straight
4 Supply/exhaust ports aJ Earthing screw plug
5 Working lines aA Electrical supply plate aD Pressure sensor
6 H-rail

62 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data

Dimensions Download CAD Data  www.festo.com/us/cad


Valve terminal with fieldbus connection

1 Solenoid valve MPA1 6 H-rail aA Earthing screw n Number of manifold blocks in a


2 Solenoid valve MPA2 7 H-rail mounting aB Electrical supply plate grid of 4 MPA1 or 2 MPA2 valves
3 Manual override 8 Mounting holes aC Pressure sensor m Number of CPX modules
4 Supply/exhaust ports 9 Pneumatic interface MPA aD Proportional pressure regulator
5 Working lines aJ CPX module

Vertical stacking components, MPA2

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 63


Valve Terminals Type 32 MPA
Technical data – Proportional pressure regulator VPPM

Function: Flow rate


380 … 1,400 l/min

Pressure regulation range


0.02 … 10 bar

Voltage
21.6 … 26.4 V DC

General technical data


Constructional design Pilot actuated diaphragm regulator
Sealing principle Soft
Actuation type Electrical
Type of control Pilot actuated
Mounting position Any
Reset method Mechanical spring
Pneumatic connection 1, 2, 3 Manifold block
Nominal diameter Pressurisation [mm] 6
Exhaust [mm] 4.5
Standard nominal flow rate 2 bar type [l/min] 380
6 bar type [l/min] 900
10 bar type [l/min] 1,400
Product weight [g] 400
Material Housing Wrought aluminium alloy, anodised

Electrical data
Electrical connection Via manifold block
Operating voltage range [V DC] 21.6 … 26.4
Residual ripple 10%
Max. electrical power consumption [W] 7
Protection against short circuit For all electrical connections
Protection against polarity reversal For all electrical connections
Protection class to EN 60529 IP65

64 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data – Proportional pressure regulator VPPM

Flow rate qn from 1} 2 as a function of output pressure p2


VPPM-6TA-…-0L2H-… (2 bar) VPPM-6TA-…-0L6H-… (6 bar)

VPPM-6TA-…-0L10H-… (10 bar)

Flow rate qn from 2 } 3 as a function of output pressure p2


VPPM-6TA-…-0L2H-… (2 bar) VPPM-6TA-…-0L6H-… (6 bar)

VPPM-6TA-…-0L10H-… (10 bar)

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 65


Valve Terminals Type 32 MPA
Technical data – Proportional pressure regulator VPPM

Operating and environmental conditions


VPPM-6TA-…-0L2H-… VPPM-6TA-…-0L6H-… VPPM-6TA-…-0L10H-…
Pressure regulation range [bar] 0.02 … 2 0.06 … 6 0.1 … 10
Operating medium Compressed air, filtered, unlubricated, grade of filtration 40μm, neutral gases
Supply pressure 1 [bar] 0 … 42) 0 … 82) 0 … 112)
Max. pressure hysteresis [bar] 0.01 0.03 0.05
Linearityy error FS (full
( scale)) Standard [%] 2
Type S1 [%] 1
Repetition accuracy FS (full scale) [%] 0.5
Temperature coefficient [%/K] 0.04
Ambient temperature [°C] 0 … 60
Temperature of medium [°C] 10 … 50
Corrosion resistance class CRC1) 2
CE mark (see declaration of conformity) To EU EMC Directive

1) Corrosion resistance class 2 as per Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants or lubricating
agents.
2) The supply pressure 1 should always be 1 bar greater than the maximum regulated output pressure.

Dimensions Download CAD Data  www.festo.com/us/cad

1 Socket head screw M4x55

Ordering data
Supply pressure 1 Pressure regulation Full-scale linearity error Code Part No. Type
range
0 … 4 bar 0.02 … 2 bar 2% QA 542220 VPPM-6TA-L-1-F-0L2H
1% QD 542217 VPPM-6TA-L-1-F-0L2H-S1
0 … 8 bar 0.06 … 6 bar 2% QB 542221 VPPM-6TA-L-1-F-0L6H
1% QE 542218 VPPM-6TA-L-1-F-0L6H-S1
0 … 11 bar 0.1 … 10 bar 2% QC 542222 VPPM-6TA-L-1-F-0L10H
1% QF 542219 VPPM-6TA-L-1-F-0L10H-S1

66 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Technical data – Proportional pressure regulator VPPM

Ordering data – Accessories


Designation Part No. Type
Mounting 558844 VMPA-BG

Manifold block without electrical manifold module and without electrical module 542223 VMPA-FB-AP-P1

Electrical manifold module for manifold block of the proportional pressure regulator 537998 VMPA1-FB-EV-AB

Electrical module 542224 VMPA-FB-EMG-P1

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 67


Valve Terminals Type 32 MPA
Ordering data – Individual valve

Ordering data – Valves on individual sub-base


Code Valve function Part No. Type
Internal pilot air
M 5/2-wayy valve,,
5/ 533376 VMPA1-M1H-M-M7-PI
single solenoid 537963 VMPA2-M1H-M-Gx-PI
J 5/2-wayy valve,,
5/ 533377 VMPA1-M1H-J-M7-PI
double solenoid 537964 VMPA2-M1H-J-Gx-PI
N 2x 3/
3/2-wayy valve,, 533382 VMPA1-M1H-N-M7-PI
normally open 537969 VMPA2-M1H-N-Gx-PI
K 2x 3/
3/2-wayy valve,, 533381 VMPA1-M1H-K-M7-PI
normally closed 537968 VMPA2-M1H-K-Gx-PI
H 2x 3/2-way valve, 533383 VMPA1-M1H-H-M7-PI
1x normally open
open,
537970 VMPA2-M1H-H-Gx-PI
1x normally closed
B 5/3-wayy valve,,
5/3 533378 VMPA1-M1H-B-M7-PI
mid-position pressurised 537965 VMPA2-M1H-B-Gx-PI
G 5/3-wayy valve,,
5/3 533379 VMPA1-M1H-G-M7-PI
mid-position closed 537966 VMPA2-M1H-G-Gx-PI
E 5/3-wayy valve,,
5/3 533380 VMPA1-M1H-E-M7-PI
mid-position exhausted 537967 VMPA2-M1H-E-Gx-PI
D 2x 2/2-way
/ y valve,, 533384 VMPA1-M1H-D-M7-PI
normally closed 537971 VMPA2-M1H-D-Gx-PI
I 2x 2/2-way valve, 545230 VMPA1-M1H-I-M7-PI
1x normally closed
closed,
545232 VMPA2-M1H-I-Gx-PI
1 x normally closed, reversible
External pilot air
MS 5/2-wayy valve,,
5/ 533385 VMPA1-M1H-M-S-M7-PI
single solenoid 537972 VMPA2-M1H-M-S-Gx-PI
JJS 5/2-wayy valve,,
5/ 533386 VMPA1-M1H-J-S-M7-PI
double solenoid 537973 VMPA2-M1H-J-S-Gx-PI
NS 2x 3/
3/2-wayy valve,, 533391 VMPA1-M1H-N-S-M7-PI
normally open 537978 VMPA2-M1H-N-S-Gx-PI
KS 2x 3/
3/2-wayy valve,, 533390 VMPA1-M1H-K-S-M7-PI
normally closed 537977 VMPA2-M1H-K-S-Gx-PI
HS 2x 3/2-way valve, 533392 VMPA1-M1H-H-S-M7-PI
1x normally open
open,
537979 VMPA2-M1H-H-S-Gx-PI
1x normally closed
BS 5/3-wayy valve,,
5/3 533387 VMPA1-M1H-B-S-M7-PI
mid-position pressurised 537974 VMPA2-M1H-B-S-Gx-PI
GS 5/3-wayy valve,,
5/3 533388 VMPA1-M1H-G-S-M7-PI
mid-position closed 537975 VMPA2-M1H-G-S-Gx-PI
ES 5/3-wayy valve,,
5/3 533389 VMPA1-M1H-E-S-M7-PI
mid-position exhausted 537976 VMPA2-M1H-E-S-Gx-PI
DS 2x 2/2-way
/ y valve,, 533393 VMPA1-M1H-D-S-M7-PI
normally closed 537980 VMPA2-M1H-D-S-Gx-PI
IS 2x 2/2-way valve, 545231 VMPA1-M1H-I-S-M7-PI
1x normally closed
closed,
545233 VMPA2-M1H-I-S-Gx-PI
1 x normally closed, reversible

68 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Accessories

Ordering data – Individual sub-base valve


Code Valve function Electrical plug-in connection
Part No. Type
M 5/
5/2-way y valve,, 533342 VMPA1-M1H-M-PI
single solenoid 537952 VMPA2-M1H-M-PI
J 5/2-wayy valve,,
5/ 533343 VMPA1-M1H-J-PI
double solenoid 537953 VMPA2-M1H-J-PI
N 2x 3/
3/2-wayy valve,, 533348 VMPA1-M1H-N-PI
normally open 537958 VMPA2-M1H-N-PI
NS 2x 3/2-way valve, 556839 VMPA1-M1H-NS-PI
normally open, mechanical spring return
W 1x 3/
3/2-wayy valve,, 540050 VMPA1-M1H-W-PI
normally open, external compressed air supply 540051 VMPA2-M1H-W-PI
K 2x 3/
3/2-wayy valve,, 533347 VMPA1-M1H-K-PI
normally closed 537957 VMPA2-M1H-K-PI
KS 2x 3/2-way valve, 556838 VMPA1-M1H-KS-PI
normally closed, mechanical spring return
H 2x 3/2-way valve, 533349 VMPA1-M1H-H-PI
1x normally open
open,
537959 VMPA2-M1H-H-PI
1x normally closed
HS 2x 3/2-way valve, 556840 VMPA1-M1H-HS-PI
1x normally open,
1x normally closed, mechanical spring return
B 5/3-wayy valve,,
5/3 533344 VMPA1-M1H-B-PI
mid-position pressurised 537954 VMPA2-M1H-B-PI
G 5/3-wayy valve,,
5/3 533345 VMPA1-M1H-G-PI
mid-position closed 537955 VMPA2-M1H-G-PI
E 5/3-wayy valve,,
5/3 533346 VMPA1-M1H-E-PI
mid-position exhausted 537956 VMPA2-M1H-E-PI
X 1x 3/
3/2-wayy valve,, 534415 VMPA1-M1H-X-PI
normally closed, external compressed air supply 537961 VMPA2-M1H-X-PI
D 2x 2/2-way
/ y valve,, 533350 VMPA1-M1H-D-PI
normally closed 537960 VMPA2-M1H-D-PI
DS 2x 2/2-way valve, 556841 VMPA1-M1H-DS-PI
normally closed, mechanical spring return
I 2x 2/2-way valve, 543605 VMPA1-M1H-I-PI
1x normally closed
closed,
543703 VMPA2-M1H-I-PI
1 x normally closed, reversible

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 69


Valve Terminals Type 32 MPA
Accessories

Ordering data
Regulator plate
Supply pressure 1 Description Code Part No. Type
[bar]
0.5
5 … 10 MPA2, connection 1 PA 543342 VMPA2-B8-R1C2-C-10
MPA2, connection 2 PC 543343 VMPA2-B8-R2C2-C-10
MPA2, connection 4 PB 543344 VMPA2-B8-R3C2-C-10
MPA2, connection 2, reversible PL 543347 VMPA2-B8-R6C2-C-10
MPA2, connection 4, reversible PK 543348 VMPA2-B8-R7C2-C-10
0.5
5…6 MPA2, connection 1 PF 549055 VMPA2-B8-R1C2-C-06
MPA2, connection 2 PH 549056 VMPA2-B8-R2C2-C-06
MPA2, connection 4 PG 549057 VMPA2-B8-R3C2-C-06
MPA2, connection 2, reversible PN 549113 VMPA2-B8-R6C2-C-06
MPA2, connection 4, reversible PM 549114 VMPA2-B8-R7C2-C-06
Pressure gauge for regulator plate
With cartridge connection for regulator, 10 bar – 543487 PAGN-26-16-P10
for regulator plate code PA, PB, PC, PL, PK
With cartridge connection for regulator, 6 bar – 543488 PAGN-26-10-P10
for regulator plate code PF, PG, PH, PN, PM

Ordering data – Proportional pressure regulator


Supply pressure 1 Pressure regulation Full-scale linearity error Code Part No. Type
range
0 … 4 bar 0.02 … 2 bar 2% QA 542220 VPPM-6TA-L-1-F-0L2H
1% QD 542217 VPPM-6TA-L-1-F-0L2H-S1
0 … 8 bar 0.06 … 6 bar 2% QB 542221 VPPM-6TA-L-1-F-0L6H
1% QE 542218 VPPM-6TA-L-1-F-0L6H-S1
0 … 11 bar 0.1 … 10 bar 2% QC 542222 VPPM-6TA-L-1-F-0L10H
1% QF 542219 VPPM-6TA-L-1-F-0L10H-S1

70 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Accessories

Ordering data
Designation Part No. Type
Mounting
For H-rail MPA with fieldbus 526032 CPX-CPA-BG-NRH
MPA with multi-pin plug connection 173498 CPA-BG-NRH
Mounting (for supply plate) 534416 VMPA-BG-RW

Mounting (for proportional pressure regulator manifold block) 558844 VMPA-BG

Manifold blocks – without electrical manifold module


For multi-pin
p plug/fieldbus
p g/ Four valve positions MPA1 533352 VMPA1-FB-AP-4-1
Two valve positions MPA2 538000 VMPA2-FB-AP-2-1
For multi-pin
p pplug/fieldbus,
g/ , duct 1 closed Four valve positions MPA1 538657 VMPA1-FB-AP-4-1-T1
Two valve positions MPA2 538677 VMPA2-FB-AP-2-1-T0
For multi-pin
p pplug/fieldbus,
g/ , duct 1 closed and duct Four valve positions MPA1 555901 VMPA1-FB-AP-4-1-S1
3/5 closed Two valve positions MPA2 555902 VMPA2-FB-AP-2-1-S0
Manifold blocks – incl. electrical manifold module and electronics module
For fieldbus Four valve positions MPA1 546802 VMPA1-AP-4-1-EMS-8
Two valve positions MPA2 546803 VMPA2-AP-2-1-EMS-4
For multi-pin
p plug
p g Four solenoid coils MPA1 546806 VMPA1-AP-4-1-EMM-4
Two solenoid coils MPA2 546807 VMPA2-AP-2-1-EMM-2
Eight solenoid coils MPA1 546804 VMPA1-AP-4-1-EMM-8
Four solenoid coils MPA2 546805 VMPA2-AP-2-1-EMM-4
Manifold blocks – for individual connection
Without ATEX specification
p Internal ppilot air MPA1 533394 VMPA1-IC-AP-1
MPA2 537981 VMPA2-IC-AP-1
External pilot
p air MPA1 533395 VMPA1-IC-AP-S-1
MPA2 537982 VMPA2-IC-AP-S-1
With ATEX specification:
p Internal ppilot air MPA1 545447 VMPA1-IC-AP-1-EX1
II 3 GD EEx nA II T95°C X IP54 MPA2 545449 VMPA2-IC-AP-1-EX1
External pilot
p air MPA1 545448 VMPA1-IC-AP-S-1-EX1
MPA2 545450 VMPA2-IC-AP-S-1-EX1
Manifold block – for proportional pressure regulator
Without electrical manifold module and without – – 542223 VMPA-FB-AP-P1
electrical module

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 71


Valve Terminals Type 32 MPA
Accessories

Ordering data
Designation Part No. Type
End plates and fieldbus pneumatic interface
Right-hand end plate 533373 VMPA-EPR
Pneumatic interface, ducted exhaust air, internal pilot air 533370 VMPA-FB-EPL-G
Pneumatic interface, ducted exhaust air, internal pilot air, for metal linking CPX 552286 VMPA-FB-EPLM-G
Pneumatic interface, ducted exhaust air, external pilot air 533369 VMPA-FB-EPL-E
Pneumatic interface, ducted exhaust air, external pilot air, for metal linking CPX 552285 VMPA-FB-EPLM-E
Pneumatic interface, flat plate silencer, internal pilot air 533372 VMPA-FB-EPL-GU
Pneumatic interface, flat plate silencer, internal pilot air, for metal linking CPX 552288 VMPA-FB-EPLM-GU
Pneumatic interface, flat plate silencer, external pilot air 533371 VMPA-FB-EPL-EU
Pneumatic interface, flat plate silencer, external pilot air, for metal linking CPX 552287 VMPA-FB-EPLM-EU
Electrical interface for AS-interface
4 inputs/4
p / outputs p Internal ppilot air Ducted exhaust air 546989 VMPA-ASI-EPL-G-4E4A-Z
Silencer 546991 VMPA-ASI-EPL-GU-4E4A-Z
External pilot
p air Ducted exhaust air 546988 VMPA-ASI-EPL-E-4E4A-Z
Silencer 546990 VMPA-ASI-EPL-EU-4E4A-Z
8 inputs/8
p / outputs p Internal ppilot air Ducted exhaust air 546993 VMPA-ASI-EPL-G-8E8A-Z
Silencer 546995 VMPA-ASI-EPL-GU-8E8A-Z
External pilot
p air Ducted exhaust air 546992 VMPA-ASI-EPL-E-8E8A-Z
Silencer 546994 VMPA-ASI-EPL-EU-8E8A-Z
Manifold block for AS-interface
Socket M12, 5-pin 546996 CPX-AB-4-M12x2-5P-M3
Socket M8, 3-pin 546998 CPX-AB-8-M8-3P-M3
Spring-loaded terminals, 32-pin 546999 CPX-AB-8-KL-4P-M3
Socket Sub-D, 25-pin 547000 CPX-AB-1-SUB-BU-25P-M3
Socket, quick connection, 4-pin 547001 CPX-AB-4-HAR-4P-M3
Electrical interface for CPI
External pilot air, ducted exhaust air 546983 VMPA-CPI-EPL-E
Internal pilot air, ducted exhaust air 546984 VMPA-CPI-EPL-G
External pilot air, silencer 546985 VMPA-CPI-EPL-EU
Internal pilot air, silencer 546986 VMPA-CPI-EPL-GU

Electrical interface for multi-pin plug connection


External pilot air, ducted exhaust air 540893 VMPA1-MPM-EPL-E
Internal pilot air, ducted exhaust air 540894 VMPA1-MPM-EPL-G
External pilot air, silencer 540895 VMPA1-MPM-EPL-EU
Internal pilot air, silencer 540896 VMPA1-MPM-EPL-GU

72 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Accessories

Ordering data
Designation Part No. Type
Electronics modules
For fieldbus connection, not electrically isolated 4 coils MPA2 537983 VMPA2-FB-EMS-4
For fieldbus connection, not electrically isolated, 4 coils MPA2 543332 VMPA2-FB-EMS-D2-4
with extended diagnostic function
For fieldbus connection, not electrically isolated, 8 coils MPA1 533360 VMPA1-FB-EMS-8
For fieldbus connection, not electrically isolated, 8 coils MPA1 543331 VMPA1-FB-EMS-D2-8
with extended diagnostic function
For fieldbus connection, electrically isolated 4 coils MPA2 537984 VMPA2-FB-EMG-4
For fieldbus connection, electrically isolated, 4 coils MPA2 543334 VMPA2-FB-EMG-D2-4
with extended diagnostic function
For fieldbus connection, electrically isolated 8 coils MPA1 533361 VMPA-FB-EMG-8
For fieldbus connection, electrically isolated, 8 coils MPA1 543333 VMPA-FB-EMG-D2-8
with extended diagnostic function
For modular multi-pin
p plug
p g connection (MPM)
( ) 2 coils MPA2 537985 VMPA2-MPM-EMM-2
4 coils MPA2 537986 VMPA2-MPM-EMM-4
4 coils MPA1 537987 VMPA1-MPM-EMM-4
8 coils MPA1 537988 VMPA1-MPM-EMM-8
Electrical module
For proportional pressure regulator 542224 VMPA-FB-EMG-P1

Electrical supply plate


Plug connection M18, 3-pin 541082 VMPA-FB-SP-V

Plug connection 7/8”, 5-pin 541083 VMPA-FB-SP-7/8-V-5POL

Plug connection 7/8”, 4-pin 541084 VMPA-FB-SP-7/8-V-4POL

Electrical manifold module for multi-pin plug connection and AS-interface


For a manifold block 2 coils MPA2 537989 VMPA2-MPM-EV-AB-2
4 coils MPA1, MPA2 537993 VMPA1-MPM-EV-AB-4
8 coils MPA1 537994 VMPA1-MPM-EV-AB-8
For a manifold block with pneumatic
p supply
pp y plate
p 2 coils MPA2 537991 VMPA2-MPM-EV-ABV-2
4 coils MPA1, MPA2 537995 VMPA1-MPM-EV-ABV-4
8 coils MPA1 537996 VMPA1-MPM-EV-ABV-8
Electrical manifold module for fieldbus connection and CPI
For a manifold block MPA1 and MPA2, for manifold block of the proportional pressure regulator 537998 VMPA1-FB-EV-AB

For a pneumatic supply plate 537999 VMPA1-FB-EV-V

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 73


Valve Terminals Type 32 MPA
Accessories

Ordering data
Designation Part No. Type
Pressure sensor
For monitoring the operating pressure in duct 1 541085 VMPA-FB-PS-1

For monitoring the pressure in exhaust ducts 3 and 5 541086 VMPA-FB-PS-3/5

For monitoring an external process pressure 541087 VMPA-FB-PS-P1

Cover
Blanking plate for vacant valve position1) 533351 VMPA1-RP

537962 VMPA2-RP

Cover for manual override, non-detenting (10 pieces) 533366 VMPA1-HBT

Cover for manual override, covered (10 pieces) 535257 VMPA1-HBV

Cover for manual override, non-detenting (10 pieces) 540897 VMPA-HBT-B

Cover for manual override, covered (10 pieces) 540898 VMPA-HBV-B

Seals for manifold block


MPA with ducted exhaust air No duct separation 533359 VMPA1-DP
Duct 1 separate 533363 VMPA1-DP-P
Duct 3/5 separate 533364 VMPA1-DP-RS
Duct 1 and 3/5 separate 533365 VMPA1-DP-PRS
MPA with flat pplate silencer No duct separation 533355 VMPA1-DPU
Duct 1 separate 533356 VMPA1-DPU-P
Duct 3/5 separate 533357 VMPA1-DPU-RS
Duct 1 and 3/5 separate 533358 VMPA1-DPU-PRS
Exhaust plate
For ducted exhaust air, with 10 mm push-in connector 533375 VMPA-AP

For ducted exhaust air, with connection QS-y 541629 VMPA-AP-y

For flat plate silencer 533374 VMPA-APU

Supply plates (without exhaust plate)


For ducted exhaust air 533354 VMPA1-FB-SP

For flat plate silencer 533353 VMPA1-FB-SPU

1) A self-adhesive label is supplied.

74 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Valve Terminals Type 32 MPA
Accessories

Ordering data
Designation Part No. Type
Multi-pin plug connection, electrical
Cover without connecting cable for self-assembly 533198 VMPA-KMS-H
PVC connectingg cable for 8 solenoid coils 2.5 m 533195 VMPA-KMS1-8-2,5
5m 533196 VMPA-KMS1-8-5
10 m 533197 VMPA-KMS1-8-10
PVC connectingg cable for 24 solenoid coils 2.5 m 533192 VMPA-KMS1-24-2,5
5m 533193 VMPA-KMS1-24-5
10 m 533194 VMPA-KMS1-24-10
PUR connectingg cable for 8 solenoid coils,, 2.5 m 533504 VMPA-KMS2-8-2,5-PUR
suitable for energy
gy chains 5m 533505 VMPA-KMS2-8-5-PUR
10 m 533506 VMPA-KMS2-8-10-PUR
PUR connectingg cable for 24 solenoid coils,, 2.5 m 533501 VMPA-KMS2-24-2,5-PUR
suitable for energy
gy chains 5m 533502 VMPA-KMS2-24-5-PUR
10 m 533503 VMPA-KMS2-24-10-PUR
Connecting cable, individual connection
Plug socket with cable, straight socket 2.5 m 158960 SIM-M8-4GD-2,5-PU

5m 158961 SIM-M8-4GD-5-PU

Plug socket with cable, angled socket 2.5 m 158962 SIM-M8-4WD-2,5-PU

5m 158963 SIM-M8-4WD-5-PU

Connecting cable, straight socket 2.5 m 541342 NEBU-M8G4-K-2.5-LE4

5m 541343 NEBU-M8G4-K-5-LE4

Connecting cable, angled socket 2.5 m 541344 NEBU-M8W4-K-2.5-LE4

5m 541345 NEBU-M8W4-K-5-LE4

Connecting cable, AS-interface connection


Connecting cable, straight plug-straight socket M12, 4-pin/5-pin, 0.2 m 542129 NEBU-M12G5-F-0.2-M12G4

Modular system for connecting cables –  Internet: nebu

Connecting cable, CPI connection


Connectingg cable WS-WD,, angled
g plug-angled
p g g socket 0.25 m 540327 KVI-CP-3-WS-WD-0,25
0.5 m 540328 KVI-CP-3-WS-WD-0,5
2m 540329 KVI-CP-3-WS-WD-2
5m 540330 KVI-CP-3-WS-WD-5
8m 540331 KVI-CP-3-WS-WD-8
Connectingg cable GS-GD,, straight
g plug-straight
p g g socket 2m 540332 KVI-CP-3-GS-GD-2
5m 540333 KVI-CP-3-GS-GD-5
8m 540334 KVI-CP-3-GS-GD-8

2008/09 – Subject to change – Valve Manifolds Type 32 MPA 75


Valve Terminals Type 32 MPA
Accessories

Ordering data
Designation Part No. Type
Push-in fitting for manifold block, pneumatic interface, supply plate
Connectingg thread M55 for tubingg O.D. 3 mm (10 pieces) 153313 QSM-M5-3-I
4 mm (10 pieces) 153315 QSM-M5-4-I
6 mm (10 pieces) 153317 QSM-M5-6-I
Connectingg thread M77 for tubingg O.D. 4 mm (10 pieces) 153319 QSM-M7-4-I
6 mm (10 pieces) 153321 QSM-M7-6-I
x for tubingg O.D.
Connectingg thread Gx 6 mm (10 pieces) 186107 QS-Gx-6-I
8 mm (10 pieces) 186109 QS-Gx-8-I
¼ for tubingg O.D.
Connectingg thread G¼ 8 mm (10 pieces) 186110 QS-G¼-8-I
10 mm (10 pieces) 186112 QS-G¼-10-I
Silencer
Connectingg thread M5 165003 UC-M5
M7 161418 UC-M7
G¼ 165004 UC-¼
Gx 161419 UC-x
Push-in sleeve connection 3 mm 165005 UC-QS-3H
4 mm 165006 UC-QS-4H
6 mm 165007 UC-QS-6H
8 mm 175611 UC-QS-8H
10 mm 526475 UC-QS-10H
Blanking plug
Thread M5 3843 B-M5
Thread M7 174309 B-M7
Thread Gx 3568 B-x
Thread G¼ 3569 B-¼
Plug
Blankingg pplugg for tubingg O.D. 4 mm 153267 QSC-4H
6 mm 153268 QSC-6H
8 mm 153269 QSC-8H
10 mm 153270 QSC-10H
Inscription labels
Inscription label holder for manifold block, transparent, for paper foil label 533362 VMPA1-ST-1-4

Inscription label holder for manifold block, 4-fold, for IBS-6x10 544384 VMPA1-ST-2-4

Inscription labels 6 x 10 in frame, 64 pieces 18576 IBS-6x10

Ordering data – Manuals


Designation Part No. Type
MPA Pneumatic English 534241 P.BE-MPA-EN
French 534243 P.BE-MPA-FR
Spanish 534242 P.BE-MPA-ES
MPA electronic description
p English 562113 P.BE-MPA-Elektronik-EN
((Pneumatic modules,, pressure
p sensor,, proportional
p p pressure
p French 562115 P.BE-MPA-Elektronik-FR
regulators, etc.) Spanish 562114 P.BE-MPA-Elektronik-ES

76 Valve Manifolds Type 32 MPA – Subject to change – 2008/09


Product Range and Company Overview

A Complete Suite of Automation Services


Our experienced engineers provide complete support at every stage of your development process, including: conceptualization,
analysis, engineering, design, assembly, documentation, validation, and production.

Custom Automation Components Custom Control Cabinets Complete Systems


Complete custom engineered solutions Comprehensive engineering support Shipment, stocking and storage services
and on-site services

The Broadest Range of Automation Components


With a comprehensive line of more than 30,000 automation components, Festo is capable of solving the most complex
automation requirements.

Electromechanical Pneumatics PLCs and I/O Devices


Electromechanical actuators, motors, Pneumatic linear and rotary actuators, PLC's, operator interfaces, sensors
controllers & drives valves, and air supply and I/O devices

Supporting Advanced Automation… As No One Else Can!


Festo is a leading global manufacturer of pneumatic and electromechanical systems, components and controls for industrial automation,
with more than 12,000 employees in 56 national headquarters serving more than 180 countries. For more than 80 years, Festo has
continuously elevated the state of manufacturing with innovations and optimized motion control solutions that deliver higher performing,
more profitable automated manufacturing and processing equipment. Our dedication to the advancement of automation extends beyond
technology to the education and development of current and future automation and robotics designers with simulation tools, teaching
programs, and on-site services.

Quality Assurance, ISO 9001 and ISO 14001 Certifications


Festo Corporation is committed to supply all Festo products and services that will meet or exceed
our customers’ requirements in product quality, delivery, customer service and satisfaction.

To meet this commitment, we strive to ensure a consistent, integrated, and systematic approach
to management that will meet or exceed the requirements of the ISO 9001 standard for Quality
Management and the ISO 14001 standard for Environmental Management.

© Copyright 2008, Festo Corporation. While every effort is made to ensure that all dimensions and specifications are correct, Festo cannot guarantee that
publications are completely free of any error, in particular typing or printing errors. Accordingly, Festo cannot be held responsible for the same. For Liability and
Warranty conditions, refer to our “Terms and Conditions of Sale”, available from your local Festo office. All rights reserved. No part of this publication may be
reproduced, distributed, or transmitted in any form or by any means, electronic, mechanical, photocopying or otherwise, without the prior written permission of
Festo. All technical data subject to change according to technical update.

Printed on recycled paper at New Horizon Graphic, Inc., FSC certified as an environmentally friendly printing plant.
Festo North America

United States
Customer Resource Center Design and Manufacturing Operations
502 Earth City Expy., Suite 125
Earth City, MO 63045
For ordering assistance, or to find
your nearest Festo Distributor,
Call: 1.800.99.FESTO
Fax: 1.800.96.FESTO
Email: customer.service@us.festo.com
For technical support,
Call: 1.866.GO.FESTO
Fax: 1.800.96.FESTO
Email: product.support@us.festo.com
Headquarters
Festo Corporation East: 395 Moreland Road, Hauppauge, NY 11788
395 Moreland Road
P.O. Box 18023
Hauppauge, NY 11788
www.festo.com/us

Sales Offices
Appleton
N. 922 Tower View Drive, Suite N
Greenville, WI 54942
Boston
120 Presidential Way, Suite 330
Woburn, MA 01801
Chicago
1441 East Business Center Drive Central: 1441 East Business Center Drive, Mt. Prospect, IL 60056
Mt. Prospect, IL 60056
Dallas
1825 Lakeway Drive, Suite 600
Lewisville, TX 75057
Detroit - Automotive Engineering Center
2601 Cambridge Court, Suite 320
Auburn Hills, MI 48326
New York
395 Moreland Road
Hauppauge, NY 11788
Silicon Valley
4935 Southfront Road, Suite F
Livermore, CA 94550 West: 4935 Southfront Road, Suite F, Livermore, CA 94550

Mexico Canada
Headquarters Headquarters
Festo Pneumatic, S.A. Festo Inc.
Av. Ceylán 3, Col. Tequesquinahuac 5300 Explorer Drive
54020 Tlalnepantla, Edo. de México Mississauga, Ontario L4W 5G4
Call: 011 52 [55] 53 21 66 00 Call: 1.905.624.9000
Fax: 011 52 [55] 53 21 66 65 Fax: 1.905.624.9001
Email: festo.mexico@mx.festo.com Email: info.ca@ca.festo.com
www.festo.com/mx www.festo.com/ca

Festo Worldwide
Argentina Australia Austria Belarus Belgium Brazil Bulgaria Canada Chile China Colombia Croatia Czech Republic Denmark
Estonia Finland France Germany Great Britain Greece Hong Kong Hungary India Indonesia Iran Ireland Israel Italy Japan
Latvia Lithuania Malaysia Mexico Netherlands New Zealand Norway Peru Philippines Poland Romania Russia Serbia Singapore
Slovakia Slovenia South Africa South Korea Spain Sweden Switzerland Taiwan Thailand Turkey Ukraine United States Venezuela

www.festo.com

You might also like