You are on page 1of 2

ANALYSIS RESULT - FORCES AND MOMENTS ON COLUMNS

COLUMN DIMENSIONS(MM)
230 380
SELF WEIGHT OF COLUMN 2.185 KN/M

AXIAL LOAD (KN) MOMENT (KN-M)


S.NO COLUMN TOTAL
X-DIR Y-DIR X-DIR Y-DIR
1 A1 40.89 17.88 58.77 28.41 8.16
2 A2 31.31 41.01 72.32 23.61 3.24
3 A3 20.29 7.55 27.84 15.99 1.56
4 B1 84.12 25.66 109.78 9.89 11.41
5 B2 65.16 58.22 123.38 8.65 4.65
6 B3 46.25 9.06 55.31 5.36 1.80
7 C1 25.98 17.64 43.62 11.84 7.98
8 C2 17.28 39.64 56.92 8.74 3.13
9 C3 14.14 7.63 21.77 6.95 1.59
ANALYSIS RESULT - FORCES AND MOMENTS ON COLUMNS

COLUMN DIMENSIONS(MM) BLOCK II


230 380
SELF WEIGHT OF COLUMN 2.185 KN/M

AXIAL LOAD (KN) LOAD TOTAL MOMENT (KN-M)


S.NO COLUMN
X-DIR Y-DIR /STOREY LOAD X-DIR Y-DIR
1 A1 42.20 35.34 77.54 399.68 16.87 9.89
2 A2 46.32 17.33 63.65 357.67 19.32 3.88
3 A3 24.28 18.69 42.97 230.47 10.11 2.74
4 B1 80.86 38.78 119.64 619.09 6.29 11.17
5 B2 89.48 81.00 170.48 836.05 7.29 4.61
6 B3 46.87 17.28 64.15 342.66 3.63 2.52
7 C1 27.94 35.09 63.03 326.49 7.81 9.76
8 C2 28.75 72.97 101.72 494.55 8.45 3.79
9 C3 16.10 18.75 34.85 191.92 4.85 2.76